Ordinance No. 1237ORDINANCE NO. 1237
AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF
VERNON AMENDING VARIOUS SECTIONS OF CHAPTERS 7,
FIRE REGULATIONS AND 24, BUILDING AND CONSTRUCTION,
OF THE VERNON MUNICIPAL CODE, ALONG WITH
AMENDMENTS, ADDITIONS AND DELETIONS AND ADOPTING BY
REFERENCE THE FOLLOWING CODES: (1) THE 2016
CALIFORNIA FIRE CODE, 24 CCR PART 9; (2) THE 2016
CALIFORNIA BUILDING CODE, 24 CCR PART 2; (3) THE
2016 CALIFORNIA ELECTRICAL CODE, 24 CCR PART 3; (4)
THE 2006 EDITION OF THE INTERNATIONAL CODE COUNCIL
ELECTRICAL CODE ADMINISTRATIVE PROVISIONS; (5) THE
2016 CALIFORNIA MECHANICAL CODE, 24 CCR PART 4; (6)
THE 2016 CALIFORNIA PLUMBING CODE, 24 CCR PART 5;
(7) THE 2016 CALIFORNIA EXISTING BUILDING CODE, 24
CCR PART 10; (8) THE 2015 INTERNATIONAL EXISTING
BUILDING CODE; (9) THE 2016 CALIFORNIA RESIDENTIAL
CODE, 24 CCR PART 2.5; (10) THE 2016 CALIFORNIA
GREEN BUILDING STANDARDS CODE ALSO CALLED THE
CALGREEN CODE, 24 CCR PART 11, AND; (11) THE 2016
CALIFORNIA ENERGY CODE, 24 CCR PART 6; REPEALING
ALL PRIOR ORDINANCES AND PARTS OF ORDINANCES IN
CONFLICT THEREWITH
WHEREAS, the City of Vernon by Ordinance No. 1217 adopted the
following codes with certain modifications and changes: the 2013
California Fire Code, the 2013 California Building Code, the 2013
California Electrical Code, the 2006 Edition of the International Code
Council Electrical Code Administrative Provisions, the 2013 California
Mechanical Code, the 2013 California Plumbing Code, the 2013 California
Existing Building Code, the 2012 International Existing Building Code,
the 2013 California Residential Code, the 2013 California Green
Building Standards Code, also called the CALGreen Code, and the 2013
California Energy Code; and
WHEREAS, the City codified said Ordinance in Chapters 7 and
24 of the Vernon Municipal Code; and
WHEREAS, every three years, the California Building Standards
Commission ("Commission") adopts the California Building Standards Code
("CBSC") Title 24 of the California Code of Regulations, which
establish uniform standards for all occupancies in the state for the
construction and maintenance of buildings, plumbing systems, mechanical
systems, electrical systems and fire and life safety systems; and
WHEREAS, since the passage of Ordinance No. 1217, the
Commission adopted a new edition of the CBSC which shall apply to all
occupancies and become effective on January 1, 2017; and
WHEREAS, California Health and Safety Code Sections 17958,
17958.5 and 17958.7, allow certain amendments to the CBSC to be made by
a local government provided express findings are made to show that such
modifications or changes are reasonably necessary because of local
climatic, geological or topographical conditions; and
WHEREAS, the amendments, deletions and additions to the CBSC
set forth in this Ordinance are based upon the express findings set
forth under a separate resolution; and
WHEREAS, pursuant to Sections 50022.2 et seq. of the
California Government Code, which authorizes the City to adopt the CBSC
and other uniform and model codes, the City intends to adopt with
amendments: (a) the 2006 Edition of the International Code Council
Electrical Code Administrative Provisions, (b) Chapters A2 and A5 and
repair criteria of the 2015 International Existing Building Code,
published by the International Code Council, as the minimum seismic
retrofit requirements for buildings of tilt -up and concrete frame
construction types for those property owners who voluntarily propose to
retrofit their buildings, and (c) the Uniform Code for Abatement of
Dangerous Buildings, 1997 Edition, published by the International
Conference of Building Officials which code was previously adopted in
- 2 -
Ordinance No. 1073, remains unchanged, and shall be the standard for
the repair of structures damaged during a disaster event; and
WHEREAS, the administrative amendments to the CBSC provide
for a Board of Appeals and authorize the City Council to determine the
membership of said Board of Appeals; and
WHEREAS, pursuant to the California Government Code Section
50022.3, the City Council on November 15, 2016, gave a first reading to
this Ordinance and the titles of said codes to be adopted and
standards, and a duly noticed public hearing was held on December 6,
2016, for the purpose of considering the adoption of said Codes.
THE CITY COUNCIL OF THE CITY OF VERNON HEREBY ORDAINS:
SECTION 1: The City Council of the City of Vernon hereby
finds and determines that all of the foregoing recitals are true and
correct.
SECTION 2: 2016 California Fire Code Adopted. The City of
Vernon hereby adopts by reference the 2016 California Fire Code as
published by the California Building Standards Commission, California
Code of Regulations, Title 24, Part 9, including appendices A, B, BB,
D, and H and all standards contained therein, including all applicable
tables, indices, addenda and footnotes. Except as otherwise provided
herein, or as later amended, said California Fire Code is hereby
referred to and by such reference is incorporated herein as if fully
set forth.
SECTION 3: 2016 California Building Code Adopted. The City
of Vernon hereby adopts by reference the 2016 California Building Code,
as published by the California Building Standards Commission,
California Code of Regulations, Title 24, Part 2, Volumes 1 and 2,
Appendices H and J, and all standards contained therein, including all
- 3 -
applicable tables, indices, addenda and footnotes. Except as otherwise
provided herein, or as later amended, said California Building Code is
hereby referred to and by such reference is incorporated herein as if
fully set forth.
SECTION 4: 2016 California Residential Code Adopted. The
City of Vernon hereby adopts by reference the 2016 California
Residential Code and Appendix V thereof, as published by the California
Building Standards Commission, California Code of Regulations, Title
24, Part 2.5, including all of its tables, indices, appendices and
footnotes. Except as otherwise provided herein, or as later amended,
said California Residential Code is hereby referred to and by such
reference is incorporated herein as if fully set forth.
SECTION 5: 2016 California Electrical Code Adopted. The
City of Vernon hereby adopts by reference the 2016 California
Electrical Code, as published by the California Building Standards
Commission, California Code of Regulations, Title 24, Part 3, including
all of its tables, indices, appendices, addenda and footnotes. Except
as otherwise provided herein, or as later amended, said California
Electrical Code is hereby referred to and by such reference is
incorporated herein as if fully set forth.
SECTION 6: 2006 International Code Council Electrical Code
Administrative Provisions Adopted. The City of Vernon hereby adopts by
reference the 2006 International Code Council Electrical Code
Administrative Provisions, as published by the International Code
Council Inc., including all of its tables, indices, appendices, addenda
and footnotes. Except as otherwise provided herein or later amended,
said International Code Council Electrical Code Administrative
Provisions is hereby referred to and by such reference is incorporated
- 4 -
herein as if fully set forth.
SECTION 7: 2016 California Plumbing Code Adopted. The City
of Vernon hereby adopts by reference the 2016 California Plumbing Code,
as published by the California Building Standards Commission,
California Code of Regulations, Title 24, Part 5, including all of its
tables, indices, appendices, addenda and footnotes. Except as otherwise
provided herein, or as later amended, said California Plumbing Code is
hereby referred to and by such reference is incorporated herein as if
fully set forth.
SECTION 8: 2016 California Mechanical Code Adopted. The
City of Vernon hereby adopts by reference the 2016 California
Mechanical Code, as published by the California Building Standards
Commission, California Code of Regulations, Title 24, Part 4, including
all of its tables, indices, appendices, addenda and footnotes. Except
as otherwise provided herein, or as later amended, said California
Mechanical Code is hereby referred to and by such reference is
incorporated herein as if fully set forth.
SECTION 9: 2016 California Existing Building Code Adopted.
The City of Vernon hereby adopts by reference Appendix Chapter Al of
the 2016 California Existing Building Code, as published by the
California Building Standards Commission, California Code of
Regulations, Title 24, Part 10, including all tables, indices,
appendices, addenda and footnotes contained therein. Except as
otherwise provided herein, or as later amended, said California
Existing Building Code is hereby referred to and by such reference is
incorporated herein as if fully set forth.
SECTION 10: 2015 International Existing Building Code
Adopted. The City of Vernon hereby adopts by reference the 2015
- 5 -
International Existing Building Code, as published by the International
Code Council, Inc., including all of its tables, indices, appendices,
addenda and footnotes. Except as otherwise provided herein, or as later
amended, said 2015 International Existing Building Code, is hereby
referred to and by such reference is incorporated herein as if fully
set forth.
SECTION 11: 2016 California Green Building Standards Code
Adopted. The City of Vernon hereby adopts by reference the 2016
California Green Building Standards Code, also known as CALGreen Code,
as published by the California Building Standards Commission,
California Code of Regulations, Title 24, Part 11, including applicable
tables, indices, appendices, addenda and footnotes. Except as otherwise
provided herein, or as later amended, said California Green Building
Standards Code is hereby referred to and by such reference is
incorporated herein as if fully set forth. The voluntary provisions in
Appendix Chapter A-4 and Chapter A-5 are not adopted as mandatory
compliance features at this time.
SECTION 12: 2016 California Energy Code Adopted. The City of
Vernon hereby adopts by reference the 2016 California Energy Code, as
published by the California Building Standards Commission, California
Code of Regulations, Title 24, Part 6, including all of its tables,
indices, appendices, addenda and footnotes. Except as otherwise
provided herein, or as later amended, said California Energy Code is
hereby referred to and by such reference is incorporated herein as if
fully set forth.
SECTION 13: Section 7.10 of Chapter 7 of the Vernon
Municipal Code is hereby amended to read as follows:
Sec. 7.10. 2016 California Fire Code, adopted.
- 6 -
The City of Vernon hereby adopts by reference the 2016 California
Fire Code as published by the California Building Standards
Commission, California Code of Regulations, Title 24, Part 9,
including appendices A, B, BB, D, and H and all standards
contained therein, including all applicable tables, indices,
addenda and footnotes. Except as otherwise provided herein, or as
later amended, said California Fire Code is hereby referred to and
by such reference is incorporated herein as if fully set forth and
are hereby adopted by reference as the Fire Code of the City of
Vernon.
SECTION 14: Section 7.12 of Chapter 7 of the Vernon
Municipal Code is hereby amended to read as follows:
Sec. 7.12. Amendments, additions, and deletions.
The 2016 California Fire Code is hereby amended as follows:
(a) Section 104.7.2, technical assistance, of the 2016
Edition of the California Fire Code is hereby amended to add the
following sentence to the end of the paragraph to read as follows:
When there is a fire, explosion, hazardous materials
incident, or other potential life or serious property threatening
situation, the fire code official can request the owner, occupant, or
operator to hire a private fire protection or hazardous materials
investigator, acceptable to the fire code official and at the expense
of the owner or operator, to provide a full report of the incident,
including, without limitation, such matters as origin, cause,
circumstances or proposed solutions to the problem.
(b) Section 104.12 is hereby added to Chapter 1 of the 2016
Edition of the California Fire Code to read as follows:
104.12 False alarms. The fire code official is authorized to
- 7 -
assess a service charge, as set forth by resolution, against the person
owning or responsible for an alarm system when a fire department
response occurs as a result of the third false alarm at the same
address or location within any twelve month period, and for each
subsequent false alarm thereafter, or against any person who
intentionally, or in violation of the law reports, or causes to be
reported, a false alarm to any department of the City of Vernon that an
emergency exists requiring immediate or emergency response by the City
of Vernon Fire Department.
(c) Section 104.13 is hereby added to Chapter 1 of the 2016
Edition of the California Fire Code to read as follows:
104.13 Vehicle/trailer creating hazard. Whenever it is
determined by a fire code official or his representative that an
unattended or attended vehicle/trailer parked or stopped upon any
public street, road, alley, right-of-way, or upon private property,
creates an immediate danger or fire hazard to itself, other vehicles,
persons, or surrounding property, the fire code official shall request
the local law enforcement agency to cause the removal of the
vehicle/trailer to a safe location, and the local law enforcement
agency shall cause the removal at the expense of the registered owner
of the vehicle/trailer, and a notice of the removal shall be given to
the registered owner as soon as feasible.
(d) Section 104.14 is hereby added to Chapter 1 of the 2016
Edition of the California Fire Code to read as follows:
104.14 Outside obstructions. No person shall park or place
any material or vehicle in any established exit way, driveway, gateway,
or alleyway between buildings that would hamper the ingress of fire
equipment in case of a fire, explosion, hazardous materials incident,
- 8 -
or other potential life or serious property threatening situation. When
in the opinion of the fire code official or his representative, any
driveway, gateway, or alleyway between buildings is so obstructed by
objects, materials, or vehicles as to impede the ingress or egress of
said way, it shall be removed immediately upon order of the fire code
official or his representative. When such obstruction is a vehicle, it
may be removed or impounded at the owner's expense and as prescribed by
law.
(e) Section 104.15 is hereby added to Chapter 1 of the 2016
Edition of the California Fire Code to read as follows:
104.15 Fire safety officer. When in the opinion of the fire
code official, it is necessary for the preservation of life and
property, due to the hazardous nature of an event, production,
operation, or function, the fire code official shall require the owner,
agent, production company, or lessee to employ or cause the employment
of one or more fire department safety officers to be on duty at such
place during such activity.
(f) Section 105.1.7 is hereby added to Chapter 1 of the 2016
Edition of the California Fire Code to read as follows:
105.1.7 Investigation fees; work without a permit. Whenever
any work, operation or action for which a permit is required by this
code has been commenced without first obtaining said permit, an
investigation shall be made before a permit may be issued for such
work. An investigation fee, in addition to the permit fee, shall be
collected whether or not a permit is then subsequently issued. The
investigation fee shall be double the amount of the permit fee set
forth in the fee schedule. The payment of such investigation fee shall
not exempt any person from compliance with all other provisions of this
- 9 -
code, nor from any penalty prescribed by law.
(g) Section 105.1.1 is hereby added to Chapter 1 of the 2016
Edition of the California Fire Code to read as follows:
105.1.1 Permits required. Permits required by this code shall
be obtained from the fire code official. Issued permits shall be
conspicuously displayed on the premises designated therein at all times
and shall be readily available for inspection by code officials.
Permit fees shall be as set forth in a fee schedule adopted by
resolution by the City Council.
(h) Section 105.6.26 of the 2016 Edition of the California
Fire Code is hereby amended to read as follows:
105.6.26 Lumber yards, woodworking plants, and pallet
storage. A permit is required for storage or processing of lumber
exceeding 100,000 board feet (8,333ft3) (236m3), or outside pallet
storage in excess of 240 units and inside storage in excess of 64
units.
(i) Section 105.6.50 is hereby added to Chapter 1 of the
2016 Edition of the California Fire Code to read as follows:
105.6.50 General use permit. In addition to the permits
required by Section 105.6, a general use permit shall be obtained from
the fire code official for any activity or operation not specifically
addressed in this article, which in the judgment of the fire code
official, is possible or likely to produce conditions hazardous to life
or property.
(j) Chapter 1, Section 105.7.19 is hereby added to Chapter 1
of the 2016 Edition of the California Fire Code to read as follows:
105.7.19 High -piled storage. A construction permit is
required for installation or modification of high -piled combustible
- 10 -
storage in racks. When using any building or portion thereof exceeding
twenty-five hundred (2,500) square feet for high -piled combustible
storage in racks, a floor plan showing the dimensions and location of
the rack system shall be submitted with the application for such
permits.
(k) Section 105.8 is hereby added to Chapter 1 of the 2016
Edition of the California Fire Code to read as follows:
105.8 Responsibility of permittee. Fire permits shall be
presumed to incorporate the provision that the applicant, the
applicant's agent, employees or contractors shall carry out the
proposed work in accordance with the approved plans and with all
requirements of this code and any other laws or regulations applicable
thereto, whether specified or not. No approval shall relieve or
exonerate any person from the responsibility of complying with the
provisions and intent of this code.
(1) Section 113.6 is hereby added to Chapter 1 of the 2016
Edition of the California Fire Code to read as follows:
113.6 Fees for services, establishment; review. The fire code
official is authorized to collect fees for services established or
modified by resolution of the City Council. The fire code official
shall review fees charged for such services at least annually and
shall, with approval of the City Administrator, recommend changes to
the council when costs for such services make it appropriate.
(m) Section 113.7 is hereby added to Chapter 1 of the 2016
Edition of the California Fire Code to read as follows:
113.7 Operational permit fees. The fee set forth and
established for the particular activity by a resolution of the City
Council shall accompany all operational permits required pursuant to
the provisions of this code.
(n) Section 113.8 is hereby added to Chapter 1 of the 2016
Edition of the California Fire Code to read as follows:
113.8 Construction permit fees. Construction permit fees
shall be paid at the time of the permit issuance. In addition to the
permit fee, the applicant shall pay a plan check fee. The fee set forth
and established for the particular activity by a resolution of the City
Council shall accompany all construction permits required pursuant to
the provisions of this code.
(o) Section 113.9 is hereby added to Chapter 1 of the 2016
Edition of the California Fire Code to read as follows:
113.9 Re -inspection fee. Whenever an inspection is scheduled
under Section 105.2.2 and the permittee is not ready for inspection and
does not inform the fire code official or his delegate at least 2 hours
prior to the scheduled inspection, a re -inspection fee may be assessed.
(p) Section 114 is hereby added to Chapter 1 of the 2016
Edition of the California Fire Code to read as follows:
SECTION 114 - RESPONSIBILITY
114.1 Responsibility for costs. Persons who personally or
through another, willingly, negligently, or in violation of law set a
fire, allow a fire to be set, allow a fire kindled or attended by them
to escape from their control, allow any hazardous material to escape
from their control, neglect to properly comply with any written notice
of the fire chief, or willfully or negligently allow the continuation
of a violation of this code and amendments thereto, are liable for the
direct and indirect expenses of fighting the fire, any investigation,
or for direct and indirect expenses incurred during a hazardous
materials incident. Such expenses shall be a charge against that
- 12 -
person. Such charge shall constitute a debt of such person, and is
collectible by the City in the same manner as in the case of an
obligation under a contract, expressed or implied and a lien may be
attached to the involved property.
(q) The definitions of "awning," "false alarm," "fire
chief," "fire code official," "fire safety officer," and "safety
container" are hereby added or amended to Section 202 of Chapter 2 of
the 2016 Edition of the California Fire Code in alphabetical order to
read as follows:
AWNING. An architectural projection that provides weather
protection, identity, or decoration and is wholly supported by the
building to which it is attached. An awning is comprised of a
lightweight frame structure over which a covering is attached.
FALSE ALARM. The willful and knowing initiation or transmission of
a signal, message or other notification of an event of fire when no
such danger exists, or the activation of any fire alarm system due to
malfunction, mechanical or electrical defect, improper operation or
procedure by any person, or a false oral or written report to any
department of the City of Vernon that an emergency exists requiring
immediate or emergency response by the Vernon Fire Department.
FIRE CHIEF. The chief officer of the fire department serving the
jurisdiction or his/her designee.
FIRE CODE OFFICIAL. The fire chief or other member of the fire
service appointed by the fire chief charged with the administration and
enforcement of this code.
FIRE SAFETY OFFICER. A sworn member of the fire department serving
the jurisdiction assigned to preserve life and property at a location,
due to the hazardous nature of the activity of an event, production,
- 13 -
operation, or function.
SAFETY CONTAINER. An approved container of not over 5 gallons
capacity, having a self -closing lid and spout cover.
(r) Section 304.1.1.1 of the 2016 Edition of the California
Fire Code is hereby added to read as follows:
304.1.1.1 Waste material near photovoltaic array system.
Accumulation of waste material shall not be permitted underneath nor
within 10 feet from a mounted photovoltaic array system.
(s) Section 311.2.2 Exceptions 1 and 2, of the 2016 Edition
of the California Fire Code are hereby deleted.
(t) Section 312.2 of the 2016 Edition of the California Fire
Code is hereby amended to read as follows:
312.2 Guard posts. Guard posts shall comply with all of the
following requirements:
1. Constructed of steel not less than 8 inches (204mm) in
diameter and concrete filled.
2. Spaced no more than 4 feet (1219mm) between posts on
center.
3. Set not less than 4 feet (1219mm) deep in a concrete
footing of not less than 18 inches (457.2 mm) in
diameter.
4. Set with the top of the posts not less than 4 feet
(1219mm) above ground.
5. Located not less than 3 feet (914 mm) from the protected
object.
6. Posts shall be painted safety yellow.
(u) Section 315.4.3 is hereby added to Chapter 3 of the 2016
Edition of the California Fire Code to read as follows:
- 14 -
315.4.3 Pallet storage height and total accumulation for
storage. Pallet storage in the open shall not exceed 15 feet (4,572 mm)
in height and a total aggregate content not exceeding 6,750 cubic feet.
Aisle separation of 15 feet (4,572 mm) is required before the next pile
or stack is created. Storage of pallets in excess of 240 pallets
requires a permit per Sec. 105.6.25.
(v) Section 315.4.4 is hereby added to Chapter 3 of the 2016
Edition of the California Fire Code to read as follows:
315.4.4 Pallets. All pallets must be stacked so that there is
visibility through the stacks to the adjacent aisles, or so organized
to assure that no temporary living facilities or places of refuge are
hidden from view. Pallets shall be stacked or piled with due regard to
the stability of piles, and in no case higher than 15 feet (4,572 mm).
(w) Section 315.4.4.1 is hereby added to Chapter 3 of the
2016 Edition of the California Fire Code to read as follows:
315.4.4.1 Clearance around pallets. Aisles between and around
open pallet stacks shall be at least 15 feet (4,572 mm) in width and
maintained free from accumulated rubbish, equipment, or other articles
or materials.
(x) Chapter 3, Section 315.4.4.2 is hereby added to Chapter
3 of the 2016 Edition of the California Fire Code to read as follows:
315.4.4.2 Pallet storage next to structure/awning. When
pallets are stored near a structure/awning, the height of the storage
shall be restricted to no higher than the structure/awning and cannot
exceed the height of the structure/awning, or 15 feet (4,572 mm),
whichever is less.
(y) Section 503.2.1 of the 2016 Edition of the California
Fire Code is hereby amended to read as follows:
- 15 -
503.2.1. Dimensions. Fire apparatus access roads shall have
an unobstructed width of not less than 27 feet (8,229 mm) and an
unobstructed vertical clearance of not less than 15 feet (4,472 mm).
(z) Section 505.1 of the 2016 Edition of the California Fire
Code is hereby amended to read as follows:
505.1 Address identification. New and existing buildings
shall have approved address numbers, building numbers or approved
building identification placed in a position that is plainly legible
and visible from the street or road fronting the property. These
numbers shall contrast with their background. Where required by the
fire code official, address numbers shall be provided in additional
approved locations to facilitate emergency response. Address numbers
shall be a minimum of 12 inches high with a minimum width of 2 inches.
Where access is by means of a private road and the building cannot be
viewed from the public way, a monument, pole or other sign or means
shall be used to identify the structure. Address numbers shall be
maintained.
(aa) Section 507.5 of the 2016 Edition of the California Fire
Code is hereby amended to read as follows:
507.5. Fire hydrant systems. When any portion of the facility
or building protected is in excess of 150 feet from a water supply on a
public street, as measured by an approved route around the exterior of
the facility or building, on -site fire hydrants and mains capable of
supplying the required fire flow shall be provided when required by the
fire code official.
(bb) Section 507.5.5 of the 2016 Edition of the California
Fire Code is hereby amended to read as follows:
507.5.5. Clear space around hydrants. Clear space of 31 feet
- 16 -
(9448.8 mm) in front of, 4 feet (914 mm) in rear of and 10 feet (3048
mm) on both sides shall be maintained around each onsite hydrant.
(cc) Section 901.4.7 is hereby added to Chapter 9 of the 2016
Edition of the California Fire Code read as follows:
901.4.7 Protection of fire protection systems and equipment.
Fire protection systems and equipment subject to possible vehicular
damage shall be adequately protected with guard posts in accordance
with Section 312 Vehicle Impact Protection, and modifications adopted
under this code.
(dd) Section 2404.2 of the 2016 Edition of the California
Fire Code is hereby amended to read as follows:
2404.2. Location of spray -finishing operations. All inside or
outside spray -finishing operations shall be conducted in an approved
spray booth constructed in accordance with Section 2404.
(ee) Section 5601.1 of the 2016 Edition of the California
Fire Code is hereby amended to read as follows:
5601.1. Prohibited and limited acts. Explosive materials
shall not be manufactured, tested or stored within the limits of the
City of Vernon.
(ff) Section 5704.2.9.6.1 of the 2016 Edition of the
California Fire Code is hereby amended to read as follows:
5704.2.9.6.1. Locations where above -ground tanks are
prohibited. Storage of Class I and Class II liquids in above ground
tanks outside of buildings within the City of Vernon and in areas 1,000
feet (304,800 mm) or more from the outside boundary of a kindergarten
through 12th grade public school shall be in approved containers not
exceeding 10,000 gallons in size. In areas of a lot or parcel within
1,000 feet (304,800 mm) of the outside boundary of said school, the
- 17 -
only Class I or Class II liquids approved for storage in above ground
tanks is diesel fuel which shall be in approved containers and shall be
limited to either two (2) 1,000 gallon tanks or one (1) 2,000 gallon
tank.
(gg) Section 6101.4 is hereby added to Chapter 61 of the 2016
Edition of the California Fire Code to read as follows:
6101.4 Inside storage or use. No LP -gases of any type or
mixture shall be permitted in any occupancy either for sale, use or
storage without approval of the fire code official.
(hh) Section 6103.2.2.1 is hereby added to Chapter 61 of the
2016 Edition of the California Fire Code to read as follows:
6103.2.2.1 Portable containers on motorized equipment. The
use of portable containers of LP -gas as motorized equipment fuel in
occupancies is limited as follows: LP -gas fuel tanks on motorized
equipment are limited to two per vehicle with a combined capacity not
to exceed 50 pounds. Refilling of tanks shall not be permitted within
the occupancy and shall be permitted only in approved locations
determined by the fire code official.
(ii) Section 6104.1 of the 2016 Edition of the California
Fire Code is hereby amended to read as follows:
6104.1. Storage of liquefied petroleum gases. Storage and
transportation of LP -gas and the installation and maintenance of
pertinent equipment shall be in accordance with NFPA 58 and shall be
subject to the approval of the fire code official. Storage is permitted
within the limits of the City of Vernon except within 1,000 feet
(304,800 mm) of a kindergarten through 12th grade public school.
Exception: Storage of LP -gas not exceeding 2,000 gallons per
parcel in approved containers is permitted in all areas within the
- 18 -
limits of the City of Vernon.
(jj) Section 6104.3.3 is hereby added to Chapter 61 of the
2016 Edition of the California Fire Code to read as follows:
6104.3.3 Tank orientation. Unless special protection is
provided and approved by the fire code official, containers of LP -gas
shall be oriented so that their longitudinal axes do not point toward
other LP -gas containers, vital process equipment, control rooms,
loading stations, flammable liquid storage tanks or required fire
access roads.
(kk) Table B105.2 of Appendix B of the 2016 Edition of the
California Fire Code is hereby amended to read as follows:
TABLE B105.2
REQUIRED FIRE -FLOW FOR BUILDINGS OTHER THAN ONE- AND TWO-FAMILY DWELLINGS,
GROUP R-3 AND R-4 BUILDINGS AND TOWNHOUSES
Automatic Sprinkler System
Minimum Fire -Flow
Flow Duration
(Design Standard)
(gallons per minute)
(hours)
No automatic sprinkler system
Value in Table B105.1(2)
Duration in Table B105.1(2)
Section 903.3.1.1 of the
50% of the value in Table
Duration in Table B105.1(2)
California Fire Code
13105.1(2)-
at the reduced flow rate
Section 903.3.1.2 of the
50% of the value in Table
Duration in Table B105.1(2)
California Fire Code
B105.1(2)a
at the reduced flow rate
For SI: 1 gallon per minute = 3.785 Urn.
a. The reduced fire -flow shall be not less than 1,500 gallons per minute.
(11) Appendix C, of the 2016 Edition of the California Fire
Code is hereby deleted.
(mm) Section D103.1 of Appendix D of the 2016 Edition of the
California Fire Code is hereby amended to read as follows:
D103.1. Access road. The dimension of the fire access road
turnarounds shall be in accordance with City of Vernon standards.
SECTION 15: Section 7.11 of Chapter 7 of the Vernon
Municipal Code is hereby amended to read as follows:
- 19 -
(a) Whenever the word "jurisdiction" is used in the
California Fire Code, it shall be held to mean the City.
(b) Whenever the term "corporation counsel" is used in the
California Fire Code, it shall be held to mean the attorney for the
City.
SECTION 16: Section 7.12-1 of Chapter 7 of the Vernon
Municipal Code is hereby amended to read as follows:
Sec. 7.12-1. Enactment of penalty sections. All offenses set
forth in this Article II shall be enforced pursuant to this Ordinance
and section 1.8-1 of the Vernon Municipal Code.
SECTION 17: Section 7.13 of Chapter 7 of the Vernon
Municipal Code is hereby amended to read as follows:
Sec. 7.13. Application for permit and issuance. All
applications for permits to construct as required under the provisions
of the California Fire Code shall be accompanied by plan check and
permit fees established in a fee schedule adopted by the city council.
(a) To obtain a permit, the applicant shall first file an
application therefor in writing on a form furnished by the director of
public works for that purpose.
(b) Plans, engineering calculations, diagrams and other
data shall be submitted in a minimum of four sets with each application
for a permit. The director of public works may require plans and
calculations to be prepared and designed by an engineer licensed by the
State to practice as such.
(c) Permit issuance shall be in accordance with the
provisions of the California Building Code as adopted and may be
amended by the City Council of the City of Vernon.
SECTION 18: Section 24.10 of Article II of Chapter 24,
- 20 -
Building and Construction, of the Code of the City of Vernon is hereby
amended to read as follows:
Sec. 24.10. 2016 California Building Code, adopted. The City
of Vernon hereby adopts by reference the 2016 California Building Code
as published by the California Building Standards Commission,
California Code of Regulations, Title 24, Part 2. Volumes 1 and 2, and
Appendices H and J, and all standards contained therein, including all
applicable tables, indices, addenda and footnotes. Except as otherwise
provided herein, or as later amended, said California Building Code is
hereby referred to and by such reference is incorporated herein as if
fully set forth and is hereby adopted by as the Building Code of the
City of Vernon.
SECTION 19: Section 24.11 of Article II of Chapter 24 the
Vernon Municipal Code is hereby amended to read as follows:
Sec. 24.11. Building Code amendments, additions, and
deletions. The 2016 California Building Code is hereby amended as
follows:
(a) Section 105.8 is hereby added to Chapter 1 of the 2016
Edition of the California Building Code to read as follows:
105.8 Responsibility of permittee. Building permits shall be
presumed to incorporate the provision, that the applicant, the
applicant's agent, employees or contractors shall carry out the
proposed work in accordance with the approved plans and with all the
requirements of the code and any other law or regulations applicable
thereto, whether specified or not. No approval shall exonerate any
person from the responsibility of complying with the provisions or
intent of the code.
(b) Section 110.7 is hereby added to Chapter 1 of the 2016
- 21 -
Edition of the California Building Code to read as follows:
110.7 Reinspection. A reinspection fee may be assessed for
each inspection or reinspection when such portion of the work for which
an inspection is called is not complete or when corrections called for
are not made.
Reinspection fees may be assessed when the inspection record
card is not posted or otherwise available at the work site, the
approved plans are not readily available to the inspector, for failure
to provide access on the date and time for which the inspection is
requested, or for deviating from the plans requiring the approval of
the building official.
In instances where reinspection fees have been assessed, the
city may deny additional inspection of the work until the required fees
are paid.
(c) Section 111.1 of the 2016 Edition of the California
Building Code is hereby amended to read as follows:
111.1 Use and occupancy. No building or structure shall be
used or occupied, and no change in the existing use or occupancy
classification of a building or structure or portion thereof shall be
made until the building official has issued a certificate of occupancy
therefore as provided herein. `Change in Use' shall include, but not be
limited to, any change in occupancy classification or any change of
tenancy of a building for which a new business license or certificate
of occupancy is required under the Code of the City of Vernon. When
determined by the building official that a special inspection is
required to determine compliance with the Code of the City of Vernon or
with this code for a certificate of occupancy, an inspection fee shall
be paid as set forth by resolution of the City Council. Issuance of a
- 22 -
certificate of occupancy shall not be construed as an approval of a
violation of the provisions of the Code of the City of Vernon, of this
code, or of any other ordinances of this jurisdiction. A certificate of
occupancy which presumes to give authority to violate or cancel the
provisions of the Code of the City of Vernon, of this code, or of any
other ordinance shall not be valid.
Exception: Certificates of occupancy are not required for
work exempt from permits under Section 105.2. A certificate of
occupancy shall not be required for a change in Tenancy of a Group R
Occupancy.
(d) Section 1505.1 of the 2016 Edition of the California
Building Code is hereby amended to read as follows:
1505.1 Roof assembly requirements. The roof assembly on any
structure regulated by this code shall be as specified in Table 1505.1
except that only fire retardant roof coverings meeting class A or B
roofing assemblies are permitted in the City of Vernon. Roof coverings
required to be listed by this section shall be tested in accordance
with ASTM E 108 or UL 790. The roofing assembly includes the roof deck,
underlayment, interlayment, insulation and covering, which is assigned
a roof classification.
Exception: Skylights and sloped glazing that comply with
Chapter 24 or Section 2610.
(e) Section 1507.3.1 of the 2016 Edition of the California
Building Code is hereby amended to read as follows:
1507.3.1 Deck requirements. Concrete and clay tile shall be
installed only over solid structural sheathing boards.
(f) Section 1613.5.2 is added to Chapter 16 of the 2016
Edition of the California Building Code to read as follows:
- 23 -
1613.5.2 Structural Separation. Modify ASCE 7 Section
12.12.3SSEquation 12.12-1 to read as follows:
S= CdVmax
M -f-
e
(12.12-1)
(g) Section 1613.5.3 is added to Chapter 16 of the 2016
Edition of the California Building Code to read as follows:
1613.5.3 Values for Vertical Combinations. Modify ASCE 7
Section 12.2.3.1 Exception 3 as follows:
3. Detached one- and two-family dwellings up to two stories
in height of light frame construction.
(h) Section 1613.5.4 is hereby added to Chapter 16 of the
2016 Edition of the California Building Code to read as follows:
1613.5.4 Wood Diaphragms. Modify ASCE 7 Section 12.11.2.2.3
as follows:
12.11.2.2.3 Wood Diaphragms. In wood diaphragms, the
continuous ties shall be in addition to the diaphragm sheathing.
Anchorage shall not be accomplished by use of toe nails or nails
subject to withdrawal nor shall wood ledgers or framing be used in
cross -grain bending or cross -grain tension. The diaphragm sheathing
shall not be considered effective as providing ties or struts required
by this section.
For structures assigned to Seismic Design Category D, E or F,
wood diaphragms supporting concrete or masonry walls shall comply with
the following:
1. The spacing of continuous ties shall not exceed 40 feet.
Added chords of diaphragms may be used to form subdiaphragms to
transmit the anchorage forces to the main continuous crossties.
2. The maximum diaphragm shear used to determine the depth
- 24 -
of the subdiaphragm shall not exceed 75% of the maximum diaphragm
shear.
(i) Section 1613.5.5 is hereby added to Chapter 16 of the
2016 Edition of the California Building Code to read as follows:
1613.5.5 Maximum SDs Value in Determination of C. and E".
Modify ASCE 7 Section 12.8.1.3 as follows:
12.8.1.3 Maximum SDs Value in Determination of CS and Ev. The
value of CS and EV are permitted to be calculated using a value of SDs
equal to 1.0 but not less than 70% of SDs as defined in Section 11.4.4,
provided that all of the following criteria are met:
1. The structure does not have irregularities, as defined
in Section 12.3.2;
2. The structure does not exceed five stories above the
lower of the base or grade plane as defined in Section 11.2, and, where
present, each mezzanine level shall be considered a story for the
purpose of this limit;
3. The structure has a fundamental period, T, that does not
exceed 0.5 seconds, as determined using Section 12.8.2;
4. The structure meets the requirements necessary for the
redundancy factor, p, to be permitted to be taken as 1.0, in accordance
with Section 12.3.4.2;
5. The site soil properties are not classified as Site
Classes E or F, as defined in Section 11.4.2; and
6. The structure is classified as Risk Category I or II, as
defined in Section 1.5.1.
(j) Section 1613.8 is hereby added to Chapter 16 of the 2016
Edition of the California Building Code to read as follows:
1613.8 Suspended Ceilings. Minimum design and installation
- 25 -
standards for suspended ceilings shall be determined in accordance with
the requirements of Section 2506.2.1 of this Code and this section.
1613.8.1 Scope. This part contains special requirements for
suspended ceilings and lighting systems. Provisions of Section 13.5.6
of ASCE 7 shall apply except as modified herein.
1613.8.2 General. The suspended ceilings and lighting systems
shall be limited to 6 feet (1828 mm) below the structural deck unless
the lateral bracing is designed by a licensed engineer or architect.
1613.8.3 Sprinkler Heads. All sprinkler heads (drops) except
fire -resistance -rated floor/ceiling or roof/ceiling assemblies, shall
be designed to allow for free movement of the sprinkler pipes with
oversize rings, sleeves or adaptors through the ceiling tile. Sprinkler
heads and other penetrations shall have a 2 inch (50mm) oversize ring,
sleeve, or adapter through the ceiling tile to allow for free movement
of at least 1 inch (25mm) in all horizontal directions. Alternatively,
a swing joint that can accommodate 1 inch (25 mm) of ceiling movement
in all horizontal directions is permitted to be provided at the top of
the sprinkler head extension. Sprinkler heads penetrating fire -
resistance -rated floor/ceiling or roof/ceiling assemblies shall comply
with Section 714 of this Code.
1613.8.4 Special Requirements for Means of Egress. Suspended
ceiling assemblies located along means of egress serving an occupant
load of 30 or more shall comply with the following provisions.
1613.8.4.1 General. Ceiling suspension systems shall be
connected and braced with vertical hangers attached directly to the
structural deck along the means of egress serving an occupant load of
30 or more and at lobbies accessory to Group A Occupancies. Spacing of
vertical hangers shall not exceed 2 feet (610 mm) on center along the
- 26 -
entire length of the suspended ceiling assembly located along the means
of egress or at the lobby.
1613.8.4.2 Assembly Device. All lay -in panels shall be
secured to the suspension ceiling assembly with two hold-down clips
minimum for each tile within a 4-foot (1219 mm) radius of the exit
lights and exit signs.
1613.8.4.3 Emergency Systems. Independent supports and braces
shall be provided for light fixtures required for exit illumination.
Power supply for exit illumination shall comply with the requirements
of Section 1008.3 of this Code.
1613.8.4.4 Supports for Appendage. Separate support from the
structural deck shall be provided for all appendages such as light
fixtures, air diffusers, exit signs, and similar elements.
(k) Section 1704.6 of the 2016 Edition of the California
Building Code is amended to read as follows:
1704.6 Structural Observations. Where required by the
provisions of Section 1704.6.1 or 1704.6.2, the owner shall employ a
structural observer to perform structural observations as defined in
Section 1702. The structural observer shall be one of the following
individuals:
1. The registered design professional responsible for the
structural design, or
2. A registered design professional designated by the
registered design professional responsible for the structural design.
Prior to the commencement of observations, the structural
observer shall submit to the building official a written statement
identifying the frequency and extent of structural observations.
The owner and owner's representative shall submit a written
- 27 -
report to the building official certified by the structural observer,
contractors, subcontractors and special inspectors under penalty of
perjury that said persons have identified the specific major structural
elements and connections that affect the vertical and lateral load
resisting systems of the structure and that said persons have reviewed
the scheduling of the required observations. Said specific major
structural elements and connections and scheduling shall be submitted
to the building official as an attachment to said written report.
Any person observing such deficiencies shall promptly report
same in writing to the owner or owner's representative, special
inspector, contractor and the building official. Upon the form
prescribed by the building official, the structural observer shall
submit to the building official a written statement at each significant
construction stage stating that the site visits have been made and
identifying any reported deficiencies which, to the best of the
structural observer's knowledge, have not been resolved. A final report
by the structural observer which states that all observed deficiencies
have been resolved shall be required before acceptance of the work by
the building official.
(1) Section 1704.6.1 of the 2016 Edition of the California
Building Code is amended to read as follows:
1704.6.1 Structural observations for seismic resistance. A
report of the structural observations shall be provided to the building
official by the structural observer for those structures assigned to
Seismic Design Category D, E or F, where one or more of the following
conditions exist:
1. The structure is classified as Risk Category III or IV
in accordance with Table 1604.5.
- 28 -
2. The height of the structure is greater than 75 feet
(22860 mm) above the base.
3. The structure is classified as Risk Category I or II in
accordance with Table 1604.5, and a lateral design is required for the
structure or portion thereof.
Exception: One-story wood framed Group R-3 and Group U
Occupancies less than 2,000 square feet in area, provided the adjacent
grade is not steeper than 1 unit vertical in 10 units horizontal (10%
sloped), assigned to Seismic Design Category D.
4. When so designated by the registered design professional
responsible for the structural design.
5. When such observation is specifically required by the
building official.
(m) Section 1705.3 of the 2016 Edition of the California
Building Code is amended to read as follows:
1705.3 Concrete Construction. The special inspections and
verifications for concrete construction shall be as required by this
section and Table 1705.3.
Exceptions: Special inspection shall not be required for:
1. Isolated spread concrete footings of buildings three
stories or less above grade plane that are fully supported on earth or
rock, where the structural design of the footing is based on a
specified compressive strength, f'c, no greater than 2,500 pounds per
square inch (psi) (17.2 Mpa) regardless of the compressive strength
specified in the construction documents or used in the footing
construction.
2. Continuous concrete footings supporting walls of
buildings three stories or less in height that are fully supported on
- 29 -
earth or rock where:
2.1. The footings support walls of light -frame construction;
2.2. The footings are designed in accordance with Table
1805.4.2; or
2.3. The structural design of the footing is based on a
specified compressive strength, f'c, no greater than
2,500 pounds per square inch (psi) (17.2 Mpa),
regardless of the compressive strength specified in the
construction documents or used in the footing
construction.
3. Nonstructural concrete slabs supported directly on the
ground, including prestressed slabs on grade, where the
effective prestress in the concrete is less than 150 psi
(1.03 Mpa).
4. Concrete patios, driveways and sidewalks, on grade.
(n) Section 1705.12 of the 2016 Edition of the California
Building Code is hereby amended to read as follows:
1705.12 Special inspections for seismic resistance. Special
inspections for seismic resistance shall be required as specified in
Sections 1705.12.1 through 1705.12.9, unless exempted by the exceptions
of Section 1704.2.
Exception: The special inspections specified in Sections
1705.12.1 through 1705.12.9 are not required for structures designed
and constructed in accordance with one of the following:
1. The structure consists of light -frame construction; the
design spectral response acceleration at short periods, SDS, as
determined in Section 1613.3.4, does not exceed 0.5; and the building
height of the structure does not exceed 35 feet (10 668 mm)
- 30 -
2. The seismic force -resisting system of the structure
consists of reinforced masonry or reinforced concrete; the design
spectral response acceleration at short periods, SDS, as determined in
Section 1613.3.4, does not exceed 0.5; and the building height of the
structure does not exceed 25 feet (7620 mm)
3. The structure is a detached one- or two-family dwelling
not exceeding two stories above grade plane, is not assigned to Seismic
Design Category D, E or F and does not have any of the following
horizontal or vertical irregularities in accordance with Section 12.3
of ASCE 7:
3.1 Torsional or extreme torsional irregularity.
3.2 Nonparallel systems irregularity.
3.3 Stiffness -soft story or stiffness -extreme soft story
irregularity.
3.4 Discontinuity in lateral strength -weak story
irregularity.
(o) Section 1807.1.4 of the 2016 Edition of the California
Building Code is hereby amended to read as follows:
1807.1.4 Permanent wood foundation systems. Permanent wood
foundation systems shall be designed and installed in accordance with
AWC PWF. Lumber and plywood shall be treated in accordance with AWPA Ul
(Commodity Specification A, Use Category 4B and Section 5.2) and shall
be identified in accordance with Section 2303.1.9.1. Permanent wood
foundation systems shall not be used for structures assigned to Seismic
Design Category D, E or F.
(p) Section 1807.1.6 of the 2016 Edition of the California
Building Code is hereby amended to read as follows:
1807.1.6 Prescriptive design of concrete and masonry
- 31 -
foundation walls. Concrete and masonry foundation walls that are
laterally supported at the top and bottom shall be permitted to be
designed and constructed in accordance with this section. Prescriptive
design of foundation walls shall not be used for structures assigned to
Seismic Design Category D, E or F.
(q) Section 1809.3 of the 2016 Edition of the California
Building Code is hereby amended to read as follows:
1809.3 Stepped footings. The top surface of footings shall be
level. The bottom surface of footings shall be permitted to have a
slope not exceeding one unit vertical in 10 units horizontal (10-
percent slope). Footings shall be stepped where it is necessary to
change the elevation of the top surface of the footing or where the
surface of the ground slopes more than one unit vertical in 10 units
horizontal (10-percent slope).
For structures assigned to Seismic Design Category D, E or F,
the stepping requirement shall also apply to the top surface of grade
beams supporting walls. Footings shall be reinforced with four No. 4
bars. Two bars shall be place at the top and bottom of the footings as
shown in Figure 1809.3.
- 32 -
RECONMND; a > b
a
b S 3'0'
b _
- Nt(f+. 244 REBAR (TOP & BU7"iOM)
BOTTOM PLATE MT.)
l �E
IlEln
A,1NI _..
kE 1111
TEPPED FOLNI)ATIONS
FIGURE 1809.3
STEPPED FOOTING
(r) Section 1809.7 and Table 1809.7 of the 2016 Edition of
the California Building Code is hereby amended to read as follows:
1809.7 Prescriptive footings for light -frame construction.
Where a specific design is not provided, concrete or masonry -unit
footings supporting walls of light -frame construction shall be
permitted to be designed in accordance with Table 1809.7. Prescriptive
footings in Table 1809.7 shall not exceed one story above grade plane
for structures assigned to Seismic Design Category D, E or F.
TABLE 1809.7
PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF
LIGHT -FRAME CONSTRUCTION a, b, c, d, e
NUMBER OF FLOORS
SUPPORTED BY THE
FOOTING'
WIDTH OF
FOOTING
inches
THICKNESS OF
FOOTING inches
1
12
6
2
15
6
3
18
8
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm
a. Depth of footings shall be in accordance with Section
1809.4.
b. The ground under the floor shall be permitted to be
excavated to the elevation of the top of the footing.
- 33 -
C.
Not Adopted.
d.
See Section 1908 for additional requirements for
concrete footings of structures assigned to Seismic
Design Category C, D, E or F.
e.
For thickness of foundation walls, see Section 1807.1.6.
f.
Footings shall be permitted to support a roof addition
to the stipulated number of floors. Footings supporting
roof only shall be as required for supporting one floor.
g.
Not Adopted.
(s)
Section 1809.12 of the 2016 Edition of the California
Building Code
is hereby amended to read as follows:
1809.12 Timber footings. Timber footings shall be permitted
for buildings of Type V construction and as otherwise approved by the
building official. Such footings shall be treated in accordance with
AWPA U1 (Commodity Specification A, Use Category 4B). Treated timbers
are not required where placed entirely below permanent water level, or
where used as capping for wood piles that project above the water level
over submerged or marsh lands. The compressive stresses perpendicular
to grain in untreated timber footing supported upon treated piles shall
not exceed 70 percent of the allowable stresses for the species and
grade of timber as specified in the American National Standards
Institute/American Wood Council National Design Specifications
(ANSI/AWC NDS). Timber footings shall not be used in structures
assigned to Seismic Design Category D, E or F.
(t) Section 1810.3.2.4 of the 2016 Edition of the California
Building Code is hereby amended to read as follows:
1810.3.2.4 Timber. Timber deep foundation elements shall be
designed as piles or poles in accordance with ANSI/AWC NDS. Round
- 34 -
timber elements shall conform to ASTM D 25. Sawn timber elements shall
conform to DOC PS-20. Timber shall not be used in structures assigned
to Seismic Design Category D, E or F.
(u) Section 1905.1.7 of the 2016 Edition of the California
Building Code is hereby amended to read as follows:
1905.1.7 ACI 318, Section 14.1.4. Delete ACI 318, Section
14.1.4, and replace with the following:
14.1.4 - Plain concrete in structures assigned to Seismic
Design Category C, D, E or F.
14.1.4.1 - Structures assigned to Seismic Design Category C,
D, E or F shall not have elements of structural plain concrete, except
as follows:
(a) Concrete used for fill with a minimum cement content of
two (2) sacks of Portland cement or cementious material
per cubic yard.
(b) Isolated footings of plain concrete supporting pedestals
or columns are permitted, provided the projection of the
footing beyond the face of the supported member does not
exceed the footing thickness.
(c) Plain concrete footings supporting walls are permitted
provided the footings have at least two continuous
longitudinal reinforcing bars. Bars shall not be smaller
than No. 4 and shall have a total area of not less than
0.002 times the gross cross -sectional area of the
footing. A minimum of one bar shall be provided at the
top and bottom of the footing. Continuity of
reinforcement shall be provided at corners and
intersections. In detached one- and two-family dwellings
- 35 -
three stories or less in height and constructed with
stud -bearing walls, are permitted to have plain concrete
footings with at least two continuous longitudinal
reinforcing bars not smaller than No. 4 are permitted to
have a total area of less than 0.002 times the gross
cross -sectional area of the footing.
(v) Section 1905.1 is amended and Sections 1905.1.9 thru
1905.1.11 are added to Chapter 19 of the 2016 Edition of the California
Building Code to read as follows:
1905.1 General. The text of ACI 318 shall be modified as
indicated in Sections 1905.1.9 through 1905.1.11.
1905.1.9 ACI 318, Section 18.7.5. Modify ACI 318, Section
18.7.5, by adding Section 18.7.5.7 and 18.7.5.8 as follows:
18.7.5.7 Where the calculated point of contraflexure is not
within the middle half of the member clear height, provide transverse
reinforcement as specified in ACI 318 Sections 18.7.5.1, Items (a)
through (c), over the full height of the member.
18.7.5.8 At any section where the design strength, (PPn, of
the column is less than the sum of the shears Ve computed in accordance
with ACI 318 Sections 18.7.6.1. and 18.6.5.1 for all the beams framing
into the column above the level under consideration, transverse
reinforcement as specified in ACI 318 Sections 18.7.5.1 through
18.7.5.3 shall be provided. For beams framing into opposite sides of
the column, the moment components are permitted to be assumed to be of
opposite sign. For the determination of the design strength, (PPn, of
the column, these moments are permitted to be assumed to result from
the deformation of the frame in any one principal axis.
1905.1.10 ACI 318, Section 18.10.4. Modify ACI 318, Section
- 36 -
18.10.4, by adding Section 18.10.4.6 as follows:
18.10.4.6 - Walls and portions of walls with Pu > 0.35Po shall
not be considered to contribute to the calculated shear strength of the
structure for resisting earthquake -induced forces. Such walls shall
conform to the requirements of ACI 318 Section 18.14.
1905.1.11 ACI 318, Section 18.12.6. Modify ACI 318, by adding
Section 18.12.6.2 as follows:
18.12.6.2 Collector and boundary elements in topping slabs
placed over precast floor and roof elements shall not be less than 3
inches (76 mm) or 6 db in thickness, where db is the diameter of the
largest reinforcement in the topping slab.
(w) Section 2304.10.1 of the 2016 Edition of the California
Building Code is hereby amended to read as follows:
2304.10.1 Fastener requirements. Connections for wood members
shall be designed in accordance with the appropriate methodology in
Section 2301.2. The number and size of fasteners connecting wood
members shall not be less than that set forth in Table 2304.10.1.
Staple fasteners in Table 2304.10.1 shall not be used to resist or
transfer seismic forces in structures assigned to Seismic Design
Category D, E or F.
Exception: Staples may be used to resist or transfer seismic
forces when the allowable shear values are substantiated by cyclic
testing and approved by the building official.
(x) Section 2304.12.5 of the 2016 Edition of the California
Building Code is hereby amended to read as follows:
2304.12.5 Wood used in retaining walls and crib walls. Wood
installed in retaining or crib walls shall be preservative treated in
accordance with AWPA U1 for soil and fresh water use. Wood shall not be
- 37 -
used in retaining or crib walls for structures assigned to Seismic
Design Category D, E or F.
(y) Section 2305.4 is added to Chapter 23 of the 2016
Edition of the California Building Code to read as follows:
2305.4 Quality of Nails. In Seismic Design Category D, E or
F, mechanically driven nails used in wood structural panel shear walls
shall meet the same dimensions as that required for hand -driven nails,
including diameter, minimum length and minimum head diameter. Clipped
head or box nails are not permitted in new construction. The allowable
design value for clipped head nails in existing construction may be
taken at no more than the nail -head -area ratio of that of the same size
hand -driven nails.
(z) Section 2305.5 is hereby added to Chapter 23 of the 2016
Edition of the California Building Code to read as follows:
2305.5 Hold-down connectors. In Seismic Design Category D, E
or F, hold-down connectors shall be designed to resist shear wall
overturning moments using approved cyclic load values or 75 percent of
the allowable seismic load values that do not consider cyclic loading
of the product. Connector bolts into wood framing shall require steel
plate washers on the post on the opposite side of the anchorage device.
Plate size shall be a minimum of 0.229 inch by 3 inches by 3 inches
(5.82 mm by 76 mm by 76 mm) in size. Hold-down connectors shall be
tightened to finger tight plus one half (1/2) wrench turn just prior to
covering the wall framing.
(aa) Section 2306.2 of the 2016 Edition of the California
Building Code is hereby amended to read as follows:
2306.2 Wood -frame diaphragms. Wood -frame diaphragms shall be
designed and constructed in accordance with AWC SDPWS. Where panels are
fastened to framing members with staples, requirements and limitations
of AWC SDPWS shall be met and the allowable shear values set forth in
Table 2306.2(1) or 2306.2(2) shall only be permitted for structures
assigned to Seismic Design Category A, B, or C.
Exception: Allowable shear values where panels are fastened
to framing members with staples may be used if such values are
substantiated by cyclic testing and approved by the building official.
The allowable shear values in Tables 2306.2(1) and 2306.2(2)
are permitted to be increased 40 percent for wind design.
Wood structural panel diaphragms used to resist seismic
forces in structures assigned to Seismic Design Category D, E or F
shall be applied directly to the framing members.
Exception: Wood structural panel diaphragms are permitted to
be fastened over solid lumber planking or laminated decking, provided
the panel joints and lumber planking or laminated decking joints do not
coincide.
(bb) Section 2306.3 is amended in Chapter 23 of the 2016
Edition of the California Building Code to read as follows:
2306.3 Wood -frame shear walls. Wood -frame shear walls shall
be designed and constructed in accordance with AWC SDPWS. For
structures assigned to Seismic Design Category D, E, or F, application
of Tables 4.3A and 4.3B of AWC SDPWS shall include the following:
1. Wood structural panel thickness for shear walls shall
not be less than 3/8 inch thick and studs shall not be spaced at more
than 16 inches on center.
2. The maximum nominal unit shear capacities for 3/8 inch
wood structural panels resisting seismic forces in structures assigned
to Seismic Design Category D, E or F is 400 pounds per linear foot
- 39 -
(plf) .
Exception: Other nominal unit shear capacities may be
permitted if such values are substantiated by cyclic testing and
approved by the building official.
3. Nails shall be placed not less than 1/2 inch in from the
panel edges and not less than 3/8 inch from the edge of the connecting
members for shear greater than 350 plf using ASD or 500 plf using LRFD.
Nails shall be placed not less than 3/8 inch from panel edges and not
less than 1/4 inch from the edge of the connecting members for shears
of 350 plf or less using ASD or 500 plf or less using LRFD.
4. Table 4.3B application is not allowed for structures
assigned to Seismic Design Category D, E, or F.
For structures assigned to Seismic Design Category D,
application of Table 4.3C of AWC SDPWS shall not be used below the top
level in a multi -level building.
Where panels are fastened to framing members with staples,
requirements and limitations of AWC SDPWS shall be met and the
allowable shear values set forth in Table 2306.3(1), 2306.3(2) or
2306.3(3) shall only be permitted for structures assigned to Seismic
Design Category A, B, or C.
Exception: Allowable shear values where panels are fastened
to framing members with staples may be used if such values are
substantiated by cyclic testing and approved by the building official.
The allowable shear values in Tables 2306.3(1) and 2306.3(2)
are permitted to be increased 40 percent for wind design. Panels
complying with ANSI/APA PRP-210 shall be permitted to use design values
for Plywood Siding in the AWC SDPWS.
(cc) Section 2307.2 is added to Chapter 23 of the 2016
- 40 -
Edition of the California Building Code to read as follows:
2307.2 Wood -frame shear walls. Wood -frame shear walls shall
be designed and constructed in accordance with Section 2306.3 as
applicable.
(dd) Table 2308.6.1 of the 2016 Edition of the California
Building Code is hereby amended to read as follows:
- 41 -
TABLE 2308.6.1 a
WALL BRACING REQUIREMENTS
MAXIMUM
BRACED PANEL LOCATION,
MAXIMUM DISTANCE
SEISUIC
STORY
SPACING OF
SPACING (O.C_) AND MINIMUNI PERCENTAGE (X)
OF BRACED WALL
DESIGN
CONDITION (SEE
BRACED
PANELS FROM EACH
CATEGORY
SECTION 23t18 2)
WALL LINES
END OF BRACED
WALL LINE
Bradng rrwlhad`'
LIB DWS. WSP SFB, PBS, PCP, HPS. GO'°
35*- ?Y'
Fach end and
cto ` Each end and : 25'- 4" o.c. Each end and S 25'- V u.c.
12*- C�'
A .glad B
-
�
3.4' dY*
Each end and
< 25'- U' o.c Each end and < 25'- 0" ticEach end anti < 25' (Y o.c
12* F„
351- fY'
NP Faeh mitt anti _ 25'- T o.c. Each end and 25'- W o.c
�—
.551- 0,
IN Each and and 25'- T 0.c Each and ands 25'-
C
Each end and 25'- 0" o.e. Each end 25'- (Y o,c.
35'- 0"
NP (minimum 1-Vv of a alI (minimum 2517c of wall
length?` lent th i
S- . < 0-iO} Each etxi and —< S_ _ < 0.50! F,ach etul and
t' o c. tminimum 21'i, '24'- 0" o,c. s minimum 4 i
of wall length i` of wall length!`
0 4 <.5 ,, <() 75: Each end 0.5 <_5,,, < 0 75 F;aih end
and e 25'- T o.c. rtium- at tit <25'- T o.c, iminintumi
mum 32"'�, of wall length?` 5,41�, of wall tengih)'
U and F
25'- f)
NP
0 75 <.S- < 100 EiL:b end 0 75 1.00— Fish end
and < 25'- (f i, C. (ndai- and < 24'- (Y" of e, i minitllniTt
mum 37 of "all length)' 75,1, of �%Al length!
5_ . �> 1.00, Each end and < S- . -, 1.00: Each end and f
25'- T o c. (minimum 48", 25'- (Y' o.c_. tminimum
of wall length'! tdCl'v «f wall length)"
— 42 —
Fair St, I inch - 2$_4 inn. 1 foot = 3104 8 nun
NP = tint Pernntted.
a. TNs table xpecifies nunimnm tegnitement3 for braced wall panels along interior or exterior braced wall fines.
b. See Section far fall dcw dption of bracing methods.
c. For Method OB, gypsum wallboard applied to frarnino supports that am xpaccd at 16 inches on center
d. The required lengths ,hall be doubled forgypsum board applied to only one face of a braced wall panel
e.. Percentage slnrwu represents the ttunimmu atnoant of bracing requned along tht building lcugth gar wall length if the ianjOurc has an irtegul:ra shape).
DWB W13 PEAS, and HPS wall braces are not permitted in Seismic Nseji Carereones D tx F
U, 'Minimum iength of navel bracing of one face of the wall for WSP Breathing Mall be at least T-O" lone or both face, of the wall for QP or PCP sheathing Mall
he at least S'-ll" lone: h,,w ratio shall not exceed 2:1 Wall framine to which sheathine used frx bracing is applied Mall be nominal 2 inch wide ractual 1 1 2 inch
(38 mm i or larger members and paced a maximum of 16 inches on center. Braced wall panel construction omcs shall not be mixed within a braced wall line.
jy WSP 4ta thing; shall be a minimum of 15 ` 2" thick nailed wwth Sd comnim placed t S inches from panel edge~ and 3aced not inore than r inches m sow antl
t'_ inches on ccntcr along intermediate framing mcxnbcrs.
(ee) Section 2308.6.5 and Figure 2308.6.5.1 of the 2016
Edition of the California Building Code are hereby amended to read as
follows:
2308.6.5 Alternative bracing. An alternate braced wall (ABW)
or a portal frame with hold-downs (PFH) described in this section is
permitted to substitute for a 48-inch (1219 mm) braced wall panel of
Method DWB, WSP, SFB, PBS, PCP or HPS. For Method GB, each 96-inch
(2438 mm) section (applied to one face) or 48-inch (1219 mm) section
(applied to both faces) or portion thereof required by Table 2308.6.1
is permitted to be replaced by one panel constructed in accordance with
Method ABW or PFH.
2308.6.5.1 Alternate braced wall (ABW). An ABW shall be
constructed in accordance with this section and Figure 2308.6.5.1. In
one-story buildings, each panel shall have a length of not less than 2
feet 8 inches (813 mm) and a height of not more than 10 feet (3048 mm).
Each panel shall be sheathed on one face with 3/8-inch (3.2 mm)
minimum -thickness wood structural panel sheathing nailed with 8d common
or galvanized box nails in accordance with Table 2304.10.1 and blocked
at wood structural panel edges. For structures assigned to Seismic
Design Category D or E, each panel shall be sheathed on one face with
15/32-inch-minimum-thickness (11.9 mm) wood structural panel sheathing
nailed with 8d common nails spaced 3 inches on panel edges, 3 inches at
- 43 -
intermediate supports. Two anchor bolts installed in accordance with
Section 2308.3.1 shall be provided in each panel. Anchor bolts shall be
placed at each panel outside quarter points. Each panel end stud shall
have a hold-down device fastened to the foundation, capable of
providing an approved uplift capacity of not less than 1,800 pounds
(8006 N). The hold-down device shall be installed in accordance with
the manufacturer's recommendations. The ABW shall be supported directly
on a foundation or on floor framing supported directly on a foundation
that is continuous across the entire length of the braced wall line.
This foundation shall be reinforced with not less than one No. 4 bar
top and bottom. Where the continuous foundation is required to have a
depth greater than 12 inches (305 mm), a minimum 12-inch by 12-inch
(305 mm by 305 mm) continuous footing or turned -down slab edge is
permitted at door openings in the braced wall line. This continuous
footing or turned -down slab edge shall be reinforced with not less than
one No. 4 bar top and bottom. This reinforcement shall be lapped 15 24
inches (381 610 mm) with the reinforcement required in the continuous
foundation located directly under the braced wall line.
Where the ABW is installed at the first story of two-story
buildings, the wood structural panel sheathing shall be provided on
both faces, three anchor bolts shall be placed at one -quarter points
and tie -down device uplift capacity shall be not less than 3,000 pounds
(13 344 N).
- 44 -
2'-8" [0 N PANEL . FOR PANEL SPL CE (F NEEDED) ADJO'NING PANEL
LEND-H �r EDGES SHALL IdEE OVER ANU SE FAS fENED '0
COMMON FRAM NG
r`
a
E
MIN. '19`' `H'CK IN00D II II I .
STRUC I URAL PANEL � 11 I A' ` 3d COMiON ran rep ti;aw�06n ar,v NAILS AT c O C.
SHEATHING ON ONE FACE T' ::it 11 IAt PANEL EDGES F OR SINGLE S FORY AND A" 4' O C.
II II I�, Al PANEL EDGES FOR -HE F IRS F OF 2 STOR F-S
MIN 2x4 FRAMING. MIN DOt1E3L 11 II I
STUDS REQUIRED ____ _ ;II
i .II i1 I�--ANCHOR BOLOS PER SEC - ON 2308 8.5.1
STUDS SUNDER HEADER AS -
REQUIRED 11 fI
HOLD-DOWN PER SECTION I II —PAIN rU9�JPv1 REINFORCING OF FOUNDATION ONE #4
BAR 'OP AND 50--' OK1 OF FOOT€NG. REINFORCING
2308 SHALL BE LAPPED -14 24 INCHES MIN.
• 1I r --
For SI: 1 inch = 25.4 mm, 1 foot = 3.4.8 mm.
a. For structures assigned to Seismic Design Category D or E, sheathed on one face with 15/32-inch-minimum-
thickness (11.9 mm) wood structural panel sheathing.
FIGURE 2308.6.5.1
ALTERNATE BRACED WALL PANEL (ABW)
(ff) Section 2308.6.5.2 and Figure 2308.6.5.2 of the 2016
Edition of the California Building Code are hereby amended to read as
follows:
2308.6.5.2 Portal frame with hold-downs (PFH). A PFH shall be
constructed in accordance with this section and Figure 2308.6.5.2. The
adjacent door or window opening shall have a full-length header. In
one-story buildings, each panel shall have a length of not less than 16
inches (406 mm) and a height of not more than 10 feet (3048 mm). Each
panel shall be sheathed on one face with a single layer of 3/8-inch
(9.5 mm) minimum -thickness wood structural panel sheathing nailed with
8d common or galvanized box nails in accordance with Figure 2308.6.5.2.
For structures assigned to Seismic Design Category D or E, each panel
shall be sheathed on one face with 15/32-inchminimum-thickness (11.9
- 45 -
mm) wood structural panel sheathing nailed with 8d common nails spaced
3 inches on panel edges, 3 inches at intermediate supports and in
accordance with Figure 2308.6.5.2. The wood structural panel sheathing
shall extend up over the solid sawn or glued -laminated header and shall
be nailed in accordance with Figure 2308.6.5.2. A built-up header
consisting of at least two 2-inch by 12-inch (51 mm by 305 mm) boards,
fastened in accordance with Item 24 of Table 2304.10.1 shall be
permitted to be used. A spacer, if used, shall be placed on the side of
the built-up beam opposite the wood structural panel sheathing. The
header shall extend between the inside faces of the first full-length
outer studs of each panel. The clear span of the header between the
inner studs of each panel shall be not less than 6 feet (1829 mm) and
not more than 18 feet (5486 mm) in length. A strap with an uplift
capacity of not less than 1,000 pounds (4,400 N) shall fasten the
header to the inner studs opposite the sheathing. One anchor bolt not
less than 5/8 inch (15.9 mm) diameter and installed in accordance with
Section 2308.3.1 shall be provided in the center of each sill plate.
The studs at each end of the panel shall have a hold-down device
fastened to the foundation with an uplift capacity of not less than
3,500 pounds (15 570 N).
Where a panel is located on one side of the opening, the
header shall extend between the inside face of the first full-length
stud of the panel and the bearing studs at the other end of the
opening. A strap with an uplift capacity of not less than 1,000 pounds
(4400 N) shall fasten the header to the bearing studs. The bearing
studs shall also have a hold-down device fastened to the foundation
with an uplift capacity of not less than 1,000 pounds (4400 N). The
hold-down devices shall be an embedded strap type, installed in
- 46 -
accordance with the manufacturer's recommendations. The PFH panels
shall be supported directly on a foundation that is continuous across
the entire length of the braced wall line. This foundation shall be
reinforced with not less than one No. 4 bar top and bottom. Where the
continuous foundation is required to have a depth greater than 12
inches (305 mm), a minimum 12-inch by 12-inch (305 mm by 305 mm)
continuous footing or turned -down slab edge is permitted at door
openings in the braced wall line. This continuous footing or turned -
down slab edge shall be reinforced with not less than one No. 4 bar top
and bottom. This reinforcement shall be lapped not less than 15 24
inches (381 610 mm) with the reinforcement required in the continuous
foundation located directly under the braced wall line.
Where a PFH is installed at the first story of two-story
buildings, each panel shall have a length of not less than 24 inches
(610 mm) .
- 47 -
I X7TNT Uf "tAaR
UOUPtL FORT,4 FRAME {T'i 0 FWCFC '�ViL I- PANELS.
Lit ILN1 t)T HFATVR
« SINGLL FORTAL FRAML (C HL, FW CLC WALL P.ANELI
PAIN I } L' LE 1 L CCWN
♦ �- / rFd CV
tiN 3`x'I:" "TETHEALER
� r
3 IQ '9 T'� P C.".L P ORT�AL F RF M4Ly
C (Ai ST RISC 10"'I
7+J lb STWP— GPPCS TL SHLATH NC
} i FASTEN TCP PLATE TO 11FACE R YJIT11 _RVC
FOR FATJEL `Ftlt € <,F
PO'NS CF " kc ST4KFP.. NA I SAT 3" C C t"P.
NFF(iFG} PpMEI EC[ ES
ty
f
SH4 L BE BLOCKED ANC
FA,STFN SHFu,Ti+INC T(� I#AUFP. 4Y TFt { t�nMwC,M
C (,CUR GY' TN N to U Ut F:.
CR GALVAN ZFD BGX t44 fS t4 3' CR'C PATTT_Rt4 A
c N OF FCRTAI. [IF GH7
f SIT M- UN AND 3 O (, IN ALL FRAtfINO (STUC)S
CNLRMY OF T-°1F,CAL
RLCCKItIG ANC S',LLS- TYP J
STTEAININU 1 (1 FRAMIN(I
�i
tf --ABfv MUTH 7 '6 FUR ONE STOW STRUCTURES
NA;LNC 1SRECLAIRE1,
11,;ICTT4,=i4"FCRUSE NFRSTCFTN0STCR",
A.TFACHFAM1, FF)CF
�$
S TR L1C:'I URF f-
F 2)t4 D CUEL£ ELOCK14 G
5 USL.0 THL?x45 MUST
+T
t0 -NJIN 2XAFW.-kTt4C
Bf NAII F_ f: T(3t .F I HFR 4
t°!TH t'i+wNk:FRS
'60' KK 1-14=CKNLS5 WOOL a
STRIIGT(1RAi PANE'.
NI N f)f,IIfu T %xz f'(;SI
�f- h41N i tb i l_!i 1 E CC YRI GE VICE iEIAP_LTXX C•' HTO
t:..ON(.RC It ;N[; NAa[U NTO FgAbING 'N
-M N I LB T L CO'hT4
Gt;t3R[ AF+t.T '4V TH $0ANt1FACTURER`S
L'FV CF
RfC;(,MPIENI)H1 CNdSI
For SI_ I luck) = 25.4 111111, 1 tout = 3ikT-8 rant. I pound = 4.448 N-
u. For strurcures u8eed to Setstnlc Deslat CatejMN Dar E sheXhed as one Face wth 1.532-Inch-minknunt-thl i sets (I L9 mm) wand uruetural panel ttteauthtC
FIGURE 2308.6.52
PORTAL FRAME WITH HOLD-DOWNS (PFH)
(gg) Section 2308.6.8.1 of Chapter 23 of the 2016 Edition of
the California Building Code is hereby amended to read as follows:
2308.6.8.1 Foundation requirements. Braced wall lines shall
be supported by continuous foundations.
Exception: For structures with a maximum plan dimension not
more than 50 feet (15240 mm), continuous foundations are required at
exterior walls only for structures assigned to Seismic Design Category
A, B, or C.
For structures in Seismic Design Categories D and E, exterior
braced wall panels shall be in the same plane vertically with the
foundation or the portion of the structure containing the offset shall
be designed in accordance with accepted engineering practice and
Section 2308.1.1.
- 48 -
(hh) Section 2308.6.9 of the 2016 Edition of the California
Building Code is hereby amended to read as follows:
2308.6.9 Attachment of sheathing. Fastening of braced wall
panel sheathing shall not be less than that prescribed in Table
2308.6.1 or 2304.10.1. Wall sheathing shall not be attached to framing
members by adhesives. Staple fasteners in Table 2304.9.1 shall not be
used to resist or transfer seismic forces in structures assigned to
Seismic Design Category D, E or F.
Exception: Staples may be used to resist or transfer seismic
forces when the allowable shear values are substantiated by cyclic
testing and approved by the building official.
All braced wall panels shall extend to the roof sheathing and
shall be attached to parallel roof rafters or blocking above with
framing clips (18 gauge minimum) spaced at maximum 24 inches (6096 mm)
on center with four 8d nails per leg (total eight 8d nails per clip).
Braced wall panels shall be laterally braced at each top corner and at
maximum 24 inches (6096 mm) intervals along the top plate of
discontinuous vertical framing.
(ii) Section 2609 of the 2016 Edition of the California
Building Code is hereby deleted.
(jj) Section 2610.9 is hereby added to Chapter 26 of the 2016
Edition of the California Building Code to read as follows:
2610.9 Approved materials. Notwithstanding the provisions in
Chapter 26, no skylight shall be installed unless the materials, the
construction standards, and the location have been approved by the
building official, all in accordance with the provisions of this code.
1. Skylights which are flat or corrugated at the roof level
shall be provided with an approved supporting barrier
- 49 -
immediately above or below the skylight.
2. Each skylight shall not exceed a maximum area of 32
square feet.
3. The aggregate area of all skylights shall not exceed 25
percent of the floor area of the room or space sheltered
by the roof in which they are installed.
4. All existing skylights which are not in conformance with
this code are deemed to be hazardous and shall be
removed or protected in accordance with this section.
(kk) Section J101 of the 2016 Edition of the California
Building Code is hereby amended to read as follows:
SECTION J101
GENERAL
J101.1 Scope. The provisions of this Appendix J apply to
grading, excavation and earthwork construction, including fills and
embankments and the control of grading site runoff, including erosion
sediments and construction -related pollutants. Where conflicts occur
between the technical requirements of this Appendix J and the
geotechnical report, the more restrictive requirement shall govern. In
addition to the provisions contained in this Appendix J, the grading
shall also comply with all provisions contained in Chapter 21 of the
City code.
J101.2 Flood hazard areas. The provisions of this Appendix J
shall not apply to grading, excavation and earthwork construction,
including fills and embankments, in floodways within flood hazard areas
established in Section 1612.3 or in flood hazard areas where design
flood elevations are specified but floodways have not been designated,
unless it has been demonstrated through hydrologic and hydraulic
- 50 -
analyses performed in accordance with standard engineering practice
that the proposed work will not result in any increase in the level of
the base flood.
J101.3 Hazards. Whenever the building official determines
that any land or any existing excavation or fill has, from any cause,
become a menace to life or limb, or endangers public or private
property, or adversely affects the safety, use or stability of public
or private property, the owner or other person in legal control of the
property concerned shall, upon receipt of a written notice thereof from
the building official, correct such condition in accordance with the
provisions of this Appendix J and the requirements and conditions set
forth in the notice so as to eliminate such condition. The owner or
other person in legal control of the property shall immediately comply
with the provisions set forth in the notice and shall complete the work
within 180 days from the date of the notice unless a shorter period of
time for completion has been specified in the notice in which case the
owner shall comply with the shorter period of time. Upon written
application and good cause shown, the building official may approve the
request for an extension of time to complete the work required by the
notice.
J101.4 Safety precautions.
1. If at any stage of work on an excavation or fill, the
building official determines that the work has become or is likely to
become dangerous to any person, or is likely to endanger any property,
public or private, the building official is hereby authorized to
require safety precautions to be immediately taken by the property
owner as a condition to continuing such permitted work or to require
cessation thereof forthwith unless and until it is made safe and to
- 51 -
amend the plans for such work.
2. Safety precautions may include, but shall not be limited
to, specifying a flatter exposed slope or construction of additional
drainage facilities, berms, terracing, compaction, cribbing, retaining
walls or buttress fills, slough walls, desilting basins, check dams,
benching, wire mesh and guniting, rock fences, revetments or diversion
walls.
3. Upon the determination of the building official that
such safety precautions during grading are necessary, the building
official shall provide a notice and order to the permittee to implement
same. After receiving such notice in writing it is unlawful for the
permittee or any person to proceed with such work contrary to such
order.
J101.5 Protection of utilities. The owner and permittee of
any property on which grading has been performed and that requires a
grading permit under Section J103 shall be jointly and severally
responsible for the prevention of damage to any public utilities or
services.
J101.6 Protection of adjacent property. The owner and
permittee of any property on which grading has been performed and that
requires a grading permit under Section J103 shall be jointly
responsible for the prevention of damage to adjacent property and no
person shall excavate on land sufficiently close to the property line
to endanger any adjoining public street, sidewalk, alley, or other
public or private property without supporting and protecting such
property from settling, cracking or other damage that might result.
Special precautions approved by the building official shall be made to
prevent imported or exported materials from being deposited on the
- 52 -
adjacent public way and/or drainage courses.
J101.7 Storm water control measures. The owner and permittee
of any property on which grading has been performed and that requires a
grading permit under Section J103 shall put into effect and maintain
all precautionary measures necessary to protect adjacent water courses
and public or private property from damage by erosion, flooding, and
deposition of mud, debris and construction -related pollutants
originating from the site during, and after, grading and related
construction activities. Furthermore, the owner and permittee shall be
jointly and severally responsible for putting into effect and
maintaining appropriate measures as deemed by the building official to
be necessary to prevent any change in cross -lot surface drainage that
may adversely affect any adjoining property as a result of grading,
construction -related activities or both. Such measures to prevent any
adverse cross -lot surface drainage effects on adjoining property shall
be required whether shown on approved grading plans or not.
J101.8 Conditions of approval. In granting any permit under
this code, the building official may include such conditions as he/she
deems to be reasonably necessary to prevent the creation of a nuisance
or hazard to public or private property. Such conditions may include,
but shall not be limited to:
1. Improvement of any existing grading to comply with the
standards of this code.
2. Requirements for fencing of excavations or fills which
would otherwise be hazardous.
3. Establishment of haul routes.
4. Establishment of water quality best management
practices.
- 53 -
J101.9 Rules and regulations.
J101.9.1 Rules. The permissive provisions of this chapter
shall not be presumed to waive any regulations imposed by other
statutes or other ordinances of the State of California or the City.
J101.9.2 Regulations. If two or more pertinent regulations
are not identical, those regulations shall prevail which are more
restrictive or which afford greater safety to life, limb, health,
property or welfare. For the purposes of these regulations, grading
permits shall be considered as building permits and shall be subject to
the administrative provisions of this code, unless otherwise
specifically provided for in this Appendix J or the Vernon Municipal
Code, or both.
J101.10 National Pollutant Discharge Elimination System
General. All grading plans and permits shall comply with the provisions
of Chapter 21 of the City Code. Sites which have been graded and which
require a grading permit under Appendix J Section J103 are subject to
penalties and fines. Payment of penalty fines shall not relieve any
persons from fully complying with the requirements of this code in the
execution of the work. All best management practices shall be installed
before grading begins or as instructed in writing by the building
official. As grading progresses, all best management practices shall be
updated as necessary to prevent erosion and control construction
related pollutants from discharging from the site. All best management
practices shall be maintained in good working order to the satisfaction
of the building official unless final grading approval has been granted
by the building official and all permanent drainage and erosion control
systems, if required, are in place.
SECTION 20: Section 24.15 of Article III of Chapter 24,
- 54 -
Building and Construction, of the Code of the City of Vernon, is hereby
amended to read as follows:
Sec. 24.15. 2016 California Electrical Code, adopted.
(a) The City of Vernon hereby adopts by reference the 2016
California Electrical Code as published by the California Building
Standards Commission, California Code of Regulations, Title 24, Part 3
including all of its tables, indices, appendices, addenda and
footnotes. Except as otherwise provided herein, or as later amended,
said California Electrical Code is hereby referred to and by such
reference is incorporated herein as if fully set forth and is hereby
adopted as the Electrical Code of the City of Vernon.
(b) The City of Vernon hereby adopts by reference the 2006
International Code Council Electrical Code Administrative Provisions,
as published by the International Code Council Inc., including all of
its tables, indices, appendices, addenda and footnotes. Except as
otherwise provided herein or later amended, said International Code
Council Electrical Code Administrative Provisions is hereby referred to
and by such reference is incorporated herein as if fully set forth and
is adopted by reference as part of the Electrical Code of the City of
Vernon.
SECTION 21: Section 24.16 of Article III of Chapter 24,
Building and Construction, of the Code of the City of Vernon, is hereby
amended as follows:
Sec. 24.16. Electrical Code amendments, additions, and
deletions. The 2016 Edition of the California Electrical Code is hereby
amended as follows:
(a) Article 110.14(A) of the 2016 Edition of the California
Electrical Code is hereby amended to add the following sentence to the
- 55 -
end of the first paragraph:
All stranded aluminum conductors shall be terminated with an
approved compression terminal.
(b) Article 200.6 of the 2016 Edition of the California
Electrical Code is hereby amended to add the following sentences after
the title line:
Color Coding. Grounded conductors of different voltage shall
be identified by white and gray; grounded conductors of the 277/480
volt system shall be gray; grounded conductors of the lower voltage
systems shall be white.
(c) Article 230.22 of the 2016 Edition of the California
Electrical Code is hereby amended to read as follows:
230.22 Insulation or Covering. Individual conductors shall be
insulated or covered. Service entrance conductors from overhead service
drops shall be installed in rigid metal raceways.
Exception: The grounded conductor of a multiconductor cable
shall be permitted to be bare.
(d) Articles 334.10(3), (4) and (5) of the 2016 Edition of
the California Electrical Code are hereby deleted.
SECTION 22: The 2006 Edition of the International Code
Council Electrical Code Administrative Provisions is hereby amended as
follows:
(a) Section 303.1 of the 2006 Edition of the International
Code Council Electrical Code Administrative provisions is hereby
amended to read as follows:
Sec 303.1 Use and Occupancy. No building or structure shall
be used or occupied until a certificate of occupancy has been provided
in accordance with the California Building Codes as amended by the City
- 56 -
of Vernon.
(b) Section 402.6 is hereby added to the 2006 Edition of the
International Code Council Electrical Code Administrative Provisions to
read as follows:
Sec. 402.6 Responsibility of permittee. Building permits
shall be presumed to incorporate the provision, that the applicant, the
applicant's agent, employees or contractors shall carry out the
proposed work in accordance with the approved plans and with all the
requirements of this code and any other law or regulations applicable
thereto, whether specified or not. No approval shall exonerate any such
person from the responsibility of complying with the provisions or
intent of this code.
(c) Section 402.7 of the 2006 Edition of the International
Code Council Electrical Code Administrative provisions is hereby added
to read as follows:
Sec 402.7 Utility Notification. An applicant for an
electrical installation that will require an increase in the amount of
power supply to the electrical service by more than 50 amps shall
notify the Vernon Gas & Electric Department of the additional new load.
(d) Section 402.8 of the 2006 Edition of the International
Code Council Electrical Code Administrative provisions is hereby added
to read as follows:
Sec 402.8 Energizing Electrical Equipment. No person shall
energize or use any electrical equipment until it has been inspected
and approved by the City.
(e) Section 404.2 of the 2006 Edition of the International
Code Council Electrical Code Administrative provisions is hereby
amended to read as follows:
- 57 -
Sec. 404.2 Electrical permit fees. Electrical permit fees
shall be set forth in a fee schedule adopted by resolution of the City
Council. A reinspection fee may be assessed for each inspection or
reinspection when such portion of the work for which an inspection is
called is not complete or when corrections called for are not made.
Reinspection fees may be assessed when the inspection record card is
not posted or otherwise available at the work site, the approved plans
are not readily available to the inspector, for failure to provide
access on the date and time for which the inspection is requested, or
for deviating from the plans requiring the approval of the building
official. In instances where reinspection fees have been assessed, the
city may deny additional inspection of the work until the required fees
are paid.
(f) Section 1102 of the 2006 Edition of the International
Code Council Electrical Code Administrative provisions is hereby
deleted.
(g) Section 1201.3 of the 2006 Edition of the International
Code Council Electrical Code Administrative provisions is hereby
amended to read as follows:
Sec 1201.3 Appliance and fixture listing. All electrical
equipment installed or used shall be listed and labeled by a City
approved recognized testing agency. All equipment shall be installed in
conformance with all instructions included as part of the listing.
SECTION 23: Section 24.20 of Article IV of Chapter 24,
Building and Construction, of the Code of the City of Vernon is hereby
amended to read as follows:
Sec. 24.20. 2016 California Mechanical Code adopted. The City
of Vernon hereby adopts by reference the 2016 California Mechanical
- 58 -
Code, as published by the California Building Standards Commission,
California Code of Regulations, Title 24, Part 4, including all of its
tables, indices, appendices, addenda and footnotes. Except as otherwise
provided herein, or as later amended, said California Mechanical Code
is hereby referred to and by such reference is incorporated herein as
if fully set forth.
SECTION 24
Section 24.21 of Article IV of Chapter 24,
Building and Construction, of the Code of the City of Vernon is hereby
amended to read as follows:
deletions.
Sec. 24.21. Mechanical Code amendments, additions, and
(a) Section 104.6 is hereby added to Chapter 1 of the 2016
Edition of the California Mechanical Code to read as follows:
104.6 Responsibility of permittee. Building permits shall be
presumed to incorporate the provision, that the applicant, the
applicant's agent, employees or contractors shall carry out the
proposed work in accordance with the approved plans and with all the
requirements of the code and any other law or regulations applicable
thereto, whether specified or not. No approval shall exonerate any
person from the responsibility of complying with the provisions or
intent of the code.
(b) Table 114.1 of the 2016 Edition of the California
Mechanical Code is hereby amended to read as follows:
Table 114.1
MECHANICAL PERMIT FEES:
Mechanical permit fees shall be set forth in a fee schedule
adopted by resolution of the City Council.
SECTION 25: Section 24.25 of Article V of Chapter 24,
- 59 -
Building and Construction, of the Code of the City of Vernon is hereby
amended to read as follows:
Sec. 24.25. 2016 California Plumbing Code adopted. The City
of Vernon hereby adopts by reference the 2016 California Plumbing Code,
as published by the California Building Standards Commission,
California Code of Regulations, Title 24, Part 5, including all of its
tables, indices, appendices, addenda and footnotes. Except as otherwise
provided herein, or as later amended, said California Plumbing Code is
hereby referred to and by such reference is incorporated herein as if
fully set forth.
SECTION 26: Section 24.26 of Article V of Chapter 24,
Building and Construction, of the Code of the City of Vernon is hereby
amended to read as follows:
Sec. 24.26. Plumbing Code amendments, additions, and
deletions. The 2016 California Plumbing Code is amended as follows:
(a) Section 104.6 is hereby added to Chapter 1 of the 2016
Edition of the California Plumbing Code to read as follows:
104.6 Responsibility of Permittee. Building permits shall be
presumed to incorporate the provision, that the applicant, the
applicant's agent, employees or contractors shall carry out the
proposed work in accordance with the approved plans and with all the
requirements of the code and any other law or regulations applicable
thereto, whether specified or not. No approval shall exonerate any
person from the responsibility of complying with the provisions or
intent of the code.
(b) Table 104.5 of the 2016 Edition of the California
Plumbing Code is hereby amended to read as follows:
Table 104.5.
PLUMBING PERMIT FEES:
Plumbing permit fees shall be set forth in a fee schedule
adopted by resolution of the City Council.
(c) Table 422.1 of the 2016 Edition of the California
Plumbing Code is hereby amended to add the following sentence after the
third paragraph:
If the actual number of expected occupants at the facility
exceed the number of occupants provided in Table A, the number of
plumbing facilities shall be determined based on the actual occupant
load. Except that the number of lavatories for a garment manufacturing
facility shall be one lavatory for every 15 employees of each sex.
(d) Section 1101.2 of the 2016 Edition of the California
Plumbing Code is hereby amended to read as follows:
1101.2 Where Required. Yard drainage piping and onsite storm
drain systems that connects to a public storm drainage systems shall be
installed in accordance with this chapter, approved public works
standards and the provisions of Chapter 21 of the City Code. Prior to
construction of any storm drain system, complete plans and hydraulic
calculations shall be approved by the agency whose storm drainage
system is to be impacted by the proposed system. Storm water shall flow
away from buildings and adjoining properties.
SECTION 27: Section 24.60 of Article IX of Chapter 24,
Building and Construction, of the Code of the City of Vernon, is hereby
amended as follows:
Sec. 24.60. 2016 California Existing Building Code adopted.
The City of Vernon hereby adopts by reference Appendix Chapter Al of
the 2016 California Existing Building Code, as published by the
- 61 -
California Building Standards Commission, California Code of
Regulations, Title 24, Part 10, including the tables, indices,
appendices, addenda and footnotes contained therein as the seismic
strengthening provisions for unreinforced masonry bearing wall
buildings for the City of Vernon. Except as otherwise provided herein,
or as later amended, said California Existing Building Code is hereby
referred to and by such reference is incorporated herein as if fully
set forth.
SECTION 28: Section 24.64 of Article IX of Chapter 24,
Building and Construction, of the Code of the City of Vernon, is hereby
amended as follows:
Sec. 24.64. Chapter A2 and A5 of the 2015 International
Existing Building Code adopted. Chapter A2 of the 2015 International
Existing Building Code, published by the International Code Council,
Inc., is hereby adopted as the minimum standard for seismic
strengthening of tilt -up concrete wall buildings, and Chapter A5 of the
2015 International Existing Building Code, published by the
International Code Council, is hereby adopted as the minimum standard
for seismic strengthening of concrete buildings. These standards are
established as a minimum guideline for those property owners
voluntarily selecting to retrofit their structures and shall not be
construed as the City of Vernon mandated program. Except as otherwise
provided herein, or as later amended, said 2015 International Existing
Building Code' is hereby referred to and by such reference is
incorporated herein as if fully set forth.
SECTION 29: Section 24.76 of Article XI of Chapter 24,
Building and Construction, of the Code of the City of Vernon is hereby
amended as follows:
- 62 -
Sec. 24.76. The 2015 Edition of the International Existing
Building Code adopted, repair criteria. The 2015 Edition of the
International Existing Building Code, published by the International
Code Council, Inc., subject however, to the amendments, additions and
deletions set forth in this article, is hereby adopted by reference as
the Repair Criteria of the City of Vernon relating to disaster repair
and reconstruction.
SECTION 30: Section 24.77 of Article XI of Chapter 24,
Building and Construction, of the Code of the City of Vernon is hereby
amended to read as follows:
Sec. 24.77. International Existing Building Code amendments,
additions and deletions.
follows:
The 2015 International Existing Building Code is amended as
(a) International Existing Building Code Section 202 is
hereby amended to add the following definitions in alphabetical order:
International Building Code - shall mean the California
Building Code as amended by the City of Vernon.
Uncontrollable Event - shall mean an act of god including a
seismic event, flood, fire, tsunami or other natural disaster beyond
the control of the property owner.
(b) International Existing Building Code Appendix A Chapter
Al is hereby amended to read as follows:
Appendix A Chapter Al
Seismic Strengthening Provisions for Unreinforced Masonry
Bearing Wall Buildings.
Section A 101 General - All damaged unreinforced masonry
buildings and structures shall be repaired and strengthened in
- 63 -
accordance with the California Existing Building Code adopted in
Section 24.60.
SECTION 31: Section 24.104 of Article XIII of Chapter 24,
Building and Construction, of the Code of the City of Vernon is amended
to read as follows:
Sec. 24.104. 2016 California Residential Code adopted. The
City of Vernon hereby adopts by reference the 2016 California
Residential Code and Appendix V thereof, as published by the California
Building Standards Commission, California Code of Regulations, Title
24, Part 2.5, including all tables, indices, addenda and footnotes.
Except as otherwise provided herein, or as later amended, said
California Residential Code is hereby referred to and by such reference
is incorporated herein as if fully set forth.
SECTION 32: Section 24.105 of Article XIII of Chapter 24,
Building and Construction, of the Code of the City of Vernon is amended
to read as follows:
Sec. 24.105. Residential Code amendments, additions, and
deletions. The 2016 Residential Code is amended as follows:
(a) Section R105.8 of the 2016 Edition of the California
Residential Code is hereby amended to read as follows:
R105.8 Responsibility of permittee. Building permits shall be
presumed to incorporate the provision, that the applicant, the
applicant's agent, employees or contractors shall carry out the
proposed work in accordance with the approved plans and with all the
requirements of the code and any other law or regulations applicable
thereto, whether specified or not. No approval shall exonerate any
person from the responsibility of complying with the provisions or
intent of the code.
- 64 -
(b) Section R108.7 is hereby added to Chapter 1 of the 2016
Edition of the California Residential Code to read as follows:
R108.7 Reinspection. A reinspection fee may be assessed for
each inspection or reinspection when such portion of the work for which
an inspection is called is not complete or when corrections called for
are not made.
Reinspection fees may be assessed when the inspection record
card is not posted or otherwise available at the work site, the
approved plans are not readily available to the inspector, for failure
to provide access on the date and time for which the inspection is
requested, or for deviating from the plans requiring the approval of
the building official.
In instances where reinspection fees have been assessed, the
city may deny additional inspection of the work until the required fees
are paid.
(c) Section R301.1.3.2 of the 2016 Edition of the California
Residential Code is hereby amended to read as follows:
R301.1.3.2 Woodframe structures. The building official shall
require construction documents to be approved and stamped by a
California licensed architect or engineer for all dwellings of
woodframe construction more than two stories and basement in height
located in Seismic Design Category A, B or C. Notwithstanding other
sections of law; the law establishing these provisions is found in
Business and Professions Code Section 5537 and 6737.1.
The building official shall require construction documents to
be approved and stamped by a California licensed architect or engineer
for all dwellings of woodframe construction more than one story in
height or with a basement located in Seismic Design Category Do, D1, D2
- 65 -
or E.
(d) Section R301.1.4 is hereby added to Chapter 3 of the
2016 Edition of the California Residential Code to read as follows:
R301.1.4 Seismic design provisions for buildings constructed
on or into slopes steeper than one unit vertical in three units
horizontal (33.3 percent slope). The design and construction of new
buildings and additions to existing buildings when constructed on or
into slopes steeper than one unit vertical in three units horizontal
(33.3 percent slope) shall comply with Section 1613.9 of the Building
Code.
(e) Items 1, 3 and 5 of Section R301.2.2.2.5 of the 2016
Edition of the California Residential Code are amended to read as
follows:
1. When exterior shear wall lines or braced wall panels are
not in one plane vertically from the foundation to the
uppermost story in which they are required.
3. When the end of a braced wall panel occurs over an
opening in the wall below.
5. When portions of a floor level are vertically offset.
(f) Section R301.2.2.3.8 is added to Chapter 3 of the 2016
Edition of the California Residential Code to read as follows:
R301.2.2.3.8 Anchorage of Mechanical, Electrical, or Plumbing
Components and Equipment. Mechanical, electrical, or plumbing
components and equipment shall be anchored to the structure. Anchorage
of the components and equipment shall be designed to resist loads in
accordance with the International Building Code and ASCE 7, except
where the component is positively attached to the structure and
flexible connections are provided between the component and associated
ductwork, piping, and conduit; and either
1. The component weighs 400 lb (1,780 N) or less and has a
center of mass located 4 ft (1.22 m) or less above the
supporting structure; or
2. The component weighs 20 lb (89N) or less or, in the case
of a distributed system, 5 lb/ft (73 N/m) or less.
(g) Section R401.1 of the 2016 Edition of the California
Residential Code is hereby amended to read as follows:
R401.1 Application. The provisions of this chapter shall
control the design and construction of the foundation and foundation
spaces for all buildings. In addition to the provisions of this
chapter, the design and construction of foundations in areas prone to
flooding as established by Table R301.2(1) shall meet the provisions of
Section R322. Wood foundations shall be designed and installed in
accordance with AWC PWF.
Exception: The provisions of this chapter shall be permitted
to be used for wood foundations only in the following situations:
1. In buildings that have no more than two floors and a
roof .
2. When interior basement and foundation walls are
constructed at intervals not exceeding 50 feet (15 240
mm) .
Wood foundations in Seismic Design Category Do, D1 or D2 shall
not be permitted.
Exception: In non -occupied, single -story, detached storage
sheds and similar uses other than carport or garage, provided the gross
floor area does not exceed 200 square feet, the plate height does not
exceed 12 feet in height above the grade plane at any point, and the
- 67 -
maximum roof projection does not exceed 24 inches.
(h) Section R403.1.2 of the 2016 Edition of the California
Residential Code is hereby amended to read as follows:
R403.1.2 Continuous footing in Seismic Design Categories Do,
Di and D2. Exterior walls of buildings located in Seismic Design
Categories Do, D1 and D2 shall be supported by continuous solid or fully
grouted masonry or concrete footings. All required interior braced wall
panels in buildings located in Seismic Design Categories Do, Dl and D2
shall be supported on continuous foundations.
(i) Section R403.1.3.6 of the 2016 Edition of the California
Residential Code is hereby amended to read as follows:
R403.1.3.6 Isolated concrete footings. In detached one- and
two-family dwellings located in Seismic Design Category A, B, or C that
are three stories or less in height and constructed with stud bearing
walls, isolated plain concrete footings supporting columns or pedestals
are permitted.
(j) Section R403.1.5 of the 2016 Edition of the California
Residential Code is hereby amended to read as follows:
R403.1.5 Slope. The top surface of footings shall be level.
The bottom surface of footings shall not have a slope exceeding one
unit vertical in 10 units horizontal (10-percent slope). Footings shall
be stepped where it is necessary to change the elevation of the top
surface of the footings or where the slope of the bottom surface of the
footings will exceed one unit vertical in 10 units horizontal (10-
percent slope).
For structures located in Seismic Design Categories Do, D1 and
D2, stepped footings shall be reinforced with four No. 4 rebar. Two
bars shall be place at the top and bottom of the footings as shown in
a W-1 M M
Figure R403.1.5.
RECONSffND; a b
bSYO'
a
—= MIN. 2-04 REBAR (TOP k BOTTOM)
J. b �4�
,-BOTTOM PLATE (TiT4
'IIN E 1111 M lill IMS fill,--` ...........
STEPPED FOUNDATIONS
FIGURE R403.1.5
STEPPED FOOTING
W Section R404.2 of the 2016 Edition of the California
Residential Code is amended to read as follows:
R404.2 Wood foundation walls. Wood foundation walls shall be
constructed in accordance with the provisions of Sections R404.2.1
through R404.2.6 and with the details shown in Figures R403.1(2) and
R403.1(3). Wood foundation walls shall not be used for structures
located in Seismic Design Category Do, D1 or D2.
(1) Section R501.1 of the 2016 Edition of the California
Residential Code is hereby amended to read as follows:
R501.1 Application. The provisions of this chapter shall
control the design and construction of the floors for all buildings
including the floors of attic spaces used to house mechanical or
plumbing fixtures and equipment. Mechanical or plumbing fixtures and
equipment shall be attached (or anchored) to the structure in
accordance with Section R301.2.2.3.8.
(m) Section R503.2.4 is added to Chapter 5 of the 2016
^��
Edition of the California Residential Code to read as follows:
R503.2.4 Openings in horizontal diaphragms. Openings in
horizontal diaphragms with a dimension perpendicular to the joist that
is greater than 4 feet (1.2 m) shall be constructed in accordance with
Figure R503.2.4.
PLYWOOD SHEATHING
' DIAPHRAGM OPENING
"*ter
METAL TIE 16GA. x 1 17 x 4'-0' MIN., (4 TOTAL)
W1 16-16d COMMON NAILS AS SHOWN
-OR-
METAL TIE /6GA. x 11/2" x (OPENING WIDTH - 4'-0') MIN.,
(2 TOTAL) W/ 24-16d COMMON NAILS
Eoi SI: i inch = 254 mm. I fan - RA 8 mm
a. Blockings shall be provided beyond headers.
b. Metal ties not less than 0.058 inch [1.47 mm (16
galvanized gage)] by 1.5 inches (38 mm) wide with eight
16d common nails on each side of the header -joist
intersection. The metal ties shall have a minimum yield
of 33,000 psi (227 MPa).
C. Openings in diaphragms shall be further limited in
accordance with Section R301.2.2.2.5.
FIGURE R503.2.4
OPENINGS IN HORIZONTAL DIAPHRAGMS
- 70 -
(n) Lines 35 and 36 of Table R602.3(1) of the 2016 Edition
of the California Residential Code are hereby amended to read as
follows:
- 71 -
TABLE 602.3(1)
FASTENING SCHEDULE —continued
ITEM DESCRIPTION OF BUILDING ELEMENTS AND TYPE OF FASTENERS c SPACING AND LOCATION
Floot
24
2 "subflexrr it -,joist or irder
3-16dbos(31''," 0,135):or
2 16d common (31: " - 0-162 `)
E3lind and face nail
i
25
2 "planks (plank & beam —floor & roof)
3-16d box (Ti., " 10.135 ): or
`1
teach ktearin � nail
2 16d commmn (3 ?z' < 0 If'52
,face
3- I Fd common 13 T,' - 0 162 `)
26
wild or tint julst d_ti joist
4 10 box (3 , 0 128 1; of
"nails
End nail
4 3 , • 0,131 - or
4-3 " 14 ga. stables. ?t18 "cr�nayt
21jd common 14 , 0.19Z 1: or
Nail f-ac h lavoir .as follraws: 32 "o.c.
at top and bottom and staggered.
1)d box 1'3 " 0.1 28 ): or
24 "o c. face nail at top and bottom
Z7
BUt1t-op i{i1X1F1S a1Kl lreanls. Z-Inctl lundwr
3 0, 131 ' tlaft,
StAkgened till t-rpjyvilte til(k's
iA4'E�rC
,end;
2 20d corm oti (4 - , 0 142 '1: or
pace naII at epids and at VAL I SPIILe
3 l Od trot (3" �.), 1281: car'
3-3 " 0.131 "nails
4-I6d bus (3 ;, 0 13
3-16d common (31 , 0,1621 or
28
Ledger strip suppcning joists or rafters
10d
4 h[it (3" J 1281; of
AtPat h'1 u 5t or ratter, f3Tcr nail
4 3 `• 0,131 "nails
29
Bridging to joist
2 10d (3 " = 0.128 `1
Each end, tcx• rvtil
SPACMG OF FASTENERS
ITEM
DESCRIPTION
OF BUILDING ELEMENTS
NUMBER AHD r
TYPE OF FASTENER'-
lrAMTH 3%
s1h s Ksc °
anct*pndvosl
Wood structural pants, subfloor, roof and lrftdor wall stealtMng to framing and partk JeWard wall sheathing to framing
(see Tabie R607-30) for wood structural panel exterlorwall sheathing to wall framing)
6dcoinnion ?2' - 0.113 ) nail (subftuor. wall)'
i
6 12,
8d common r21; , " - 0.131 `1 nail (roof)
8d common nail (21"? "= 0.131 1
G 12
I ski cotnrnon (3 - 0,10 1 nail. or
"
t; 1
8d (21); 0 131 ') deformed nail
Other wall sheathing)
z "structural cellulosic- fiberbuald
I ;, "galvanized roufftx nail, 'head
sheathing
diameter. or I `crown staple 16 ga.. 11lt "long
6
3-:3,
4
"structural cellulosic
1 r4 "galvanized roofing nail. ,' ,s "head diame-
�,'q
ffl)ertxrard Sheathing
ter, or I cr>iwn staple 16 ga I "howl
3 -
1,
. > g,tntl sheathins
I -, "galvanized rwfing nail: slaplegals�anizm
-
'srlww`~,
7 ?
t ,- I
1 . , ' long 1 ? i T% fx' 4V nr S
it; `
start sheathing
1 .',t "galvanized rrxrfitig nail; stable s�atvanized.
g b p
] �8 "long: l' .is screws, Type W or S
Wood suuctural panels, combination sttrfloor underlaytment to framing
?;
and less "
hd deformed (2 0 IN ) nail: or
G l2
a
8d common f20.13l `1 nail
38
1
8d common t2 I,. 0.131 `t nail: or
G 1
8d deformed (21iz `", 0-120 1 nail
39
1,.-` - ! 1'
11)d common 1:3 0.148 "j nail: or
6 l'
3 4
ii I C1Fi61-nled (21+ j1) IN 1 rod
k �71 11 I olm-h = y # nrm, l toot = J04 8 non. I mile per tm: m 0 441 nu's 1 k i MP1 i
— 72 —
FABLE R60Z.3(1)—continued
FASTENING SCHEDULE
a. Nails are simoth common, bcx or detormed shanks except inhere otherwise stated ;Malls used :or traming and sheathing connections shall have minimurn
a•.e,ag,e LendiiW. •.ield a,.hUwn. 60 kA for >lunk diauertet of (1192 ilrlh,i'1M t.�an wii luili. W kst lut Auttk diauletets IA(F;el 111,1110 141 ia,_h Lut
not lalg�l thm 0 171 in, h. and lix, ksi for shank Iianle(el> r,f [},142 iwh or 1eti,
b- Staples are 16 gjgv sire and have a minimum .l ;-Inch on diame?er crownw idlh.
c Nails shall be spaced at n&t more than 6 inches on center at all supports where spans are 48 inches or greater.
d Fourfr»I b" 9 t.oa of I frllsr Lv t) I'mAs shall Ie applied �trtti, all"
r Sp-ing of ta-tcnrr• not Indudrd In this mbls shall t,r. ha—d inn Tlhlr R60? :O?
f 1+herr Itte ullinrate dwsign vind :fre l is 1111 tatph i,l Iea • Itails fill atla. hirg wn,Hl wlvcRnal panel roof a,ralhtng to gable earl v.,Ill trannrlg shall he spat l fi
inehrs inn ,'tiller 11 hete'he ultinttte demgll Mild 4 is gfealn Man Lill nigh nails h,l attar hing pall loll 41eMililigg tr_I inirntfr+iiatr wIlP(gtN Jill be
spared 6 Inches on center tar minimum 48-inch distance trorn ridges. Paves and gahte end xalk and 4 inches on center no Fa Lie end will tramigv,
g Gvpsum shealhiig shall i Aitonn r> AST%f C I % zro1 sw]] t� install[d ill atiol*latx r a�ith f.A 2�,3 Fihwtr)anl nrathing;hah ionfc,ntl to 1ST1R C 2i78
h_ Spa, inp, of fist—', on fixer �hr ,thing panel sdges appli to pat*l kges mpp;rtel b• framing, members aim] requirctit bhxkinF and at Vfoi perimeles5 otik.
slwling of ttsteners on n,e,f ahealhirtg. pawl kge, apple, Li panel rflgr, supt xt'l I,: ftarnirgg nwmb�s JIM IYquirerl bLxking $(ackirwe, of nK,f or Root
%hr'llhirig I7:illrl rrlges pCtpCllth,'lllar to the h-alltillg lnelld er r Ti—li IN?t 1" I—vi 'i rX,'p/ a, "Jull"I I... 1)rlwr l l—ki011;s "t hi- " ii . H( p flu ftrr 4,111 1,
supproned Lv traming members or solid blocking.
i• 1t her' a ratlel is tash�(W4 lc, all adjsCPla palaliei ire aetofdaoee will, this plotiide nvt. toe nails ,It one side (,f the nat(er alai IC' alails Wnli
the ceiling Icisr to tap plate In accordance with this schedule The toe nail on the apposite ,ide at the raWr stuff not be required.
Use of siykl : in Ixaced well panels gall he prohibitu4 ill Seixnic Design (lAtew_ry L),ti U,. or D .
(o) Footnote "b" of Table R602.3(2) of the 2016 Edition of
the California Residential Code is amended to read as follows:
b. Staples shall have a minimum crown width of 7/16-inch on
diameter except as noted. Use of staples in roof, floor, subfloor, and
braced wall panels shall be prohibited in Seismic Design Category Do,
D1, or D2 .
(p) Table R602.10.3(3) of the 2016 Edition of the California
Residential Code are hereby amended to read as follows:
- 73 -
TABLE R602.10.3(3)
BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
SAIL CLASS D
• WALL HEIGHT ■ 10 FEET
• 1A PSF FLOOR DEAD LOAD
NNI M M TOTAL LENGTH (FEET) Of BRACED WALL PANELS
• 15 PSF RAAftCEILtNG DEAD LOAD
REQUIRED ALONG EACH BRACED WALL LINE"
• BRACED WALL LINE SPACING _ 25 FEET
Seismic Design
Stoty Location
Braced Wall Lino
Lergh
Mhod uw
et
kwhod GB f
Metivods
DWB, SFB, PBS,
iAetltiod
Mks
CS-WSP.
Category
(floor.
PCP, HPS, CS-
WSP
CS-G
SFBrf
20
30
40
50
7.5
10,0
5.0
1
li).iJ
5,0
7.5
100
3.2
4.8
6A
2.7
4.1
5,4
12 5
8,0
6.8
10
tiP
4, 5
4 5
3.t1
2.6
20
NP
9.i1
90
6.0
5.1
t-�
itownhnns"un1\l
;1
Np
13
1 ,3
9.07,7
40
NP
ISO
18.0
12,O
10.2
50
NP
LZ J
22
15.0
1 Z.8
1t?
tip
6.i?
6.0
4.5
3,8
20
NP
120
12.0
9.0
7.7
30
NP
180
18.0
13.5
11.:
d0
NP
24 0
24 0
18.0
I S.3
5i?
NP
)10 0
30 0
22.5
II
10
Np
4-4
s9 5.6
1.8
1.6
20
NP
&-; I I.a
3.6
3.1
tip
1e
t14 166
:A
4,6
40
Np
44-4 2_.��
4-1-4 2>.a
7.2
6.1
5-i i
NP
+R4 -, 6
4 34 ;�
9.0
7.7
l0
Np
A" a
NP
tip
44-; NP
4)-; NP
7.7�
6.4
Do
tti
Np
444 a
a
11.3
9,6
40
NP
4" NP
e%" Ny
15.0
1Z.8
50
N p
INP
,p
18.8
16.0
10
?o
N p
NP
4-z,
4-" aNT
f
444
5.3
10.5
4,5
9.0
;0
Np
4i-""
1..h
13.4
-10
\p
4444 NP
tiIP
21.0
17,9
so
:tiP
4" a 1
-3" 2
26.3
22.3
(continued)
- 74 -
TABLE R602.10.3(3)-continued
BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
+ SOIL CLASS D
WALL HEIGHT = 10 FEET
10 PSF FLOOR DEAD LOAD
MINIMUM TOTAL LENGTH (FEET) OF BRACED WALL PANELS
15 PSF ROOF iCEILING DEAD LOAD
REQUIRED ALONG EACH BRACED WALL LINE"
BRACED WALL LINE SPACING _ 25 FEET
Seismic Design
Story Location
Story
Braced Wall Lkw
LengthWgti
Method L1Bd
Methods
DWS, SF8.
Method GB t PBS, PCP
Method
Methods
S-WSP,
Category
,
WSW
WSP
CS-G
srej
10
NP
4-4 6,0 4-4 6,1a
2.0
1.7
2I)
NP
" 12.0 " 12.0
4.0
3 A
30
40
NP
N P
4-14 18.0 9+4 Ll J(
+-� '.LQ k-4 ;11
9.0
80
} 1
68
al)
NP
T- LIP 4 4 it l
10.0
8.5
10
NP
fr9
4.5
3.8
�h l
N P
a 2 El -t 2 4# N-p
9 let
7 7
Di
30
NP
NE 4" U
13.5
11.5
40
N F'
a a
18.0
15 .'1
50
N P
�"p a � ti
22.5
19.1
l+)
NF'
9
to 0
5 1
20
N P
4q-►_+ NE +SIP
12.0
t 0 2
N F'
NP 3?
18.11
15 3
4f_)
N P
74-0 NP 344 NP
24.0
204
y0
NP
4.2-9 NP 424 ^7E
30.0
255
1!
'v P
8ls 4-0- : (
2.5
2 1
2(1
N P
r- 16 8-1+ 16 D
5.0
4.3
.V
NP
1-?t?- ?-10 1-�a.a,
715
6.4
10
NP
wi-w- 320 14;-�3^rt
10.0
8.5
.il:i
N P
�##- Lo Ct -444- L±
12.5
106
10
NP
_74 a NP
5.5
4.7
2! s
N P
4-;,4 12 4-", a
I If)
SI 4
30
NP
22�-& a, 42.4 M
16.5
14 0
40
N P
39-c_i a 4" NP
22.0
18 7
4" NF' 4-4 U
27.5
23 4
?
10
NP
NP NP
NP
NP
?6
NP
NP NP
NF'
NP
30
NP
NP NP
NP
NP
40
NP
NP NP
NP
NP
N P
NP NP
NP
NP
10
N P
NP NP
75
64
20
NP
NP NP
15.0
12.8
CI ipple wall iwlo-v
3l)
N F
NP NP
�.
2' .
191
one or trva-StnIV dwelling
40
NV
NP NP
30.0
25 5
tiV
NP NP
37.5
31 Si
- 75 -
a Fine:irint+gir)IA-m shall Iw perntittrl
tt tb'all btae-ing length, rle bpi <vi -it) a soil site rims -1) - [ttt�tlio3►atwo of to;t. itg:eogth I-t•M"o the S, c�ab-les asxwiaflerl with the seismic desigi) cateoilie
shall to pemtitted -..hen a site-specitl-_ S value Is determined in acroaiance with Section if 13.3 tit the IntemarioaaF &Bdirr Code.
c ;inhere the hrac:d -..all line length is greater than 41 teet bnc:ed wall lines shall b- permitted to ire divided Into shouter sEgnaents having lengths of 50 teet or
IFss.;i[ the anxa)ni e4 lnvcitgwithin warh nwni sh,ill be ill Aith this laW
d. Method LIB shall ha.•e ggsum board taste rwA to not less than tine 7idu with nails or screws in acrwilance with Table k6112.3f I for?xterlor sheathinp or
Table PAP, 3 6 foi ;tit mor0,•p-:(m lr>sid�,fo,Aog -A fa>t».iw-, at yan«I shall -1 Fs.-s d R ire hes.
r Methiul 0-SIFB itOes txn appk iA Seismi, D41"Agn Car briii�. C3 ,. D; and 1)
I. %lohcoi5 CtB and P(-P braced ivaII panel h•vi ratio hall not ctcced 1 I in SD(- U,, D, tx 1)Mcihodc MV13. SFB, PBS. and HPS arc not perrnitt" in SDK'
U� U" "IL).
,e—,.� -�
(q) Table R602.10.4 of the 2016 Edition of the California
Residential Code is amended to read as follows:
TABLE R602.10.4
BRACING METHODS-1
CONNECTION CRITERIA'
METHODS, MATEMAL
MINIMUM THICKNESS
RGURE
Fat[torwra
Spoeing
1 x _ U o(id ar
1�`cKxl. ' wJ c inane n nails
Wtiu[J: pet stud ;sacj
LEB
appro.cd trxtal Straps
it35 t i W ar,oh•.'rx
it
3-8d ='+'_ ' lciu, t 0-I `3" Ilia.[ ndib
ti.p and I•ilitom plate%
Let -it acuw
maximum 16"
{{,�
Metal.
Stuffs Spacing
Metal strap: per munutntttsrer
per nanufieturer
D«B
L[iae tP.1
"rl ncminaiftr t-
max irriti m 24
jj
r'
'Kd 'i "'bn 11Jia'iamIs
or
Pet stud
ueti�:xi hoardsstud
---_ __ - --
stein,
--- --- -_---
l
- — ---
_' I lone staples
- - -- -=-- ` es
WSP
Udcomnon;21:1"xt.19")-jails Exttitof
h"edee, 1--Feld
- �1`cxxi
't3s"edge-�istaneetaceneie.�ge
i-�-��+-
1rue:tural Panel
� ! ! �r,t t ____
8d wrcu?axi ,2112'k0A3-) tails
Sec Sxti m ROW
17�1
-- -
3�" a e dist�n:-es4x�nel edoe _ _ _.. _
6'r cd:c, I GL Ili
Bi M'sp
- --y - -- --
V4 o(A Structural
4" at pane! cdees
Panels A,tf. Stow
Sec' Fi wt R(02.10.6.:
iu cet>ttul,.1n t' 1,"` x. 0.131 t ❑sil,
I? " at intermediate
f !a
clasonr, V-,rcor
supp.)Rs l" at braced
- I See. `i a v
waJl panel end pats
= 1160=. It) c, c t
i
I! _ k,nL r t 12-dia.ifor 1" thick
SFB
Siiuc�.urd
mixin,um 1
^�.
I I I I
sh, lthmgI I,,ng x t I _'' dta
(for, �hiekshtathin.,1
�'Cd=Csti`iicIC,
fiberkx? ud >:h yth-
:mu Spac�rn*
j•
=:ilt.antrccl nKdta� nazis,tr loot ctimmnn
`
!
Inn« � (1.131 "dia.) nails
_
Nails ;n s; il'N s tt[ Tatito R602 31 1) Cof
Fitt all tfc cd Mall
rirrnx I,K;)ti ne
1xlnel lia annm
(.7
Gvp,uill Drard
ulgtti includm ;op
NatlSen tiicw5 po Table R701.1 sex
,and bett)m slats) 7'
nkriir I�x'atir=n:
field
PEsr'i
"f.ir
Fill , ix1 ctiurn[u[t
13at'ticletx.ard
rna,*;mwm In
1
Ic•n_ t 3 113"dia.t psis
�,
F1 t Ise rvmntatt
s edges h' tielt
ahcactut�
ISreS�r, tl6nkNi
;tudspacnL
-. _=
IS'"lone x0IZl'dia)naik
PCP
Pk ILlalid
See SL t[ rn R701 h :,of
tua"Ju[lu!ti I5
= '
l
I'l on-. I z c 1i, dii. head n uli
tit
h i _ lafr all [raining
Cement plaster
;tlju spactn_
__
i," 1,,nL. I _•fie staples
tnemberi
EPS
Har7he>drd
+ `her marrnun Ifi' ;
).lMtI ,JiaO ra5'dia head nails titth
.,.
erieth to acc• )mmMaiL I +,
! edges b ueli
panel sidinr�
tail spac n
pe vttatwn into studs
AB-
A.Itenlatr
Sce Scuioii R(02-10).1
S`` ,
Section RH)-.1(J.1
braced u ll
(continued)
- 76 -
TABLE R602.10.4-continued
BRACING METHODSf
Y----- i---
CONNECTIONGRITEF;IA' ----
METHODS, MATERIAL
MINIMUM THICKNESS
FIGURE
Fssisnrs I 5panng
PFH
Peful frtnie with
See See Iihn R601 ifi f See Se,-tntn Rt: O 10 1)
J
lrul�i-dotins
't �'�'
J
J
PFG
t
&T 4Ytiun R6021.10-F-1 Sce Sectim R602-10.0.?
'J
y
Portal Iratncat �aragc
tad cortrrron r 1.r2'xG.13t 1' ails
f'S•SZ Sp
301 edcle distarce to vanel ed o edov, 1 _' .. fio Id
Ct}ntinuously shcaihci'
_
uccxl sWc'tural pure!
8dcotmlon
15C32"
21Q xG.1 i1 nails
•" " ...__ a,, i �, r.
3A8"
'-dile. distarce to pariel ed i-:mic i �.
b ' edge,
J
f5�...
=
Continuously shealhed
wood mctural panel
=� =
Ste Method CS -'A' SP Set Mahod C S-WSP
_U
et1'-ai ent li� l':1f1�e
15F�2"
,
i
�7�nines
'+
CS-PF
i
Continaouslysheathec
''
See �cCim k6)_.1 -6.-Y `ici tit ticfl kt?ittv.ltl.(.t
p.trial frame
-
I lr " Ions, x 0. 12"dia
=
i
(for", tni;k sheaihinei
cs-SFW
i .. If 25,1 sat
-
x(i.l?' die.
Cuntimik,usk -slicathcu
3113.ximuill 16'
�
f )C "��� " lifick Sheathtlt.! I"od-cs 6 fic114
;trtti�turfl fihcrhimril
shill ;gNlcinc
TI,t1_lti1ng
oalvmi/od rm ing mails or
Pd commc,n
12 [on c,x0.131'diainail��
r-,.r Si 1 inch = _- 4 mm. i f t = zos mm- I decree = ,)ill's ail_ I lx,und pit ,yuarc fo it = 4' ,� N.n I mile per hour = 0 44- 11Ii4_
a. Adhesive attachment of -.+'all sheathing. including Method I,& stroll toot be permitted in Seismic Design Categories C. D,, D, and D2,
b. Applies to panels next to garage door opening where s ipportinggable end wall or r+aof load only. Shall only be used on one wall of the garage. In Seismic
Design Categories Drt, D; aria D- roof covering dead load shall not exceed 3 PSL
c. Garage. openings adjacent to a Method CS , panel shall be provided with a header in accordance with Table R602.51, I)- re. lull -height clear opening shall not
be Polunittrvl adjac0111 h_, a Method CS (. panel
d. Method CS SFB does not apply in Seismic Design Categories Di- D, and D. -
e. Method applies to detached one- and two-family dwellings in Seismic Design Categories D1 through D, only.
f. Methods GB and PCP braced wall panel h Nv ratio shall not exceed 1 :1 in SDC Da, D_ or D Methods LIB. DWB, SFB, PBS, HPS, and PFG are not
permitted in SDC Dg, D_. of D
g. L se of staples in braced wall panels shall be prohibited in SDC D D,. or DY
— 77 —
(r) Figure R602.10.6.1 of the 2016 Edition of the California
Residential Code is hereby amended to read as follows:
1522"
MIN 4*3 AOOD
STR)CTtJRAL P-NEL —
SPEA.THING OF! ONE 74CE
Pal?i L M17,1 —
GOUBLE STUDS REOUIRED
d HOLD-C61NN OR .21 STRAP -TYPE —
AFIC:HORS PER TABLE R602 13 6 1 rDN
OF EACH SHC\NNFCR CLARI'Y;
STRAP -TYPE ANCHORS SHALL BE
PERMITTED TJ 8E ATT94CHE0OvER
THE WOOD STRUCTURAL PANEL
PANEL MUST BE A' 1 ACHEC
TO ,ONCRETE F }CTIN-s OR
CONCRETE F JlIND4TION --
.114LL CONTINUOUS OVER
BRACfC '.'i�Lt. LINE
42i V2" DIAMETER ANCHOR
BOLTS LOCATED BET1tiEEN
�' ANO 12- CDF EACH Et0 7
THE SEGMENT
VA 4ELLENGTH PER
-FIE R, 02 10 TOP PLATE SHALL BE CONTINUOUS
OVER BRACED WALL PANEL
FOR PANEL SPLICE (IF WEEDED)-
ADJOIWIG PANE LEDP ES3HALLMFET
O'ERAND BE FASTENEDWCIJLIt'tA
FRAMING
K, COMMON 9R G : -Beni tJAiLS {M 7
0 C AT PAtIEL EDGES FOR, SINGLE
STORY A.NC @ t` if C PatJEL EDGES
FORTHE FIRST OF 2STDRIES
STUDS UNCER iEhCER AS REOt_IIRED
90 CO MIACtJ 994 e-,6' 49 N: iLS @ 12
,D C LT INTER -R SUPPORTS
IAIrx REINFORCIPIv OF F,,DJNDATION,
ONE 94 SAR ")P kNC BJTTCIJ LAP
84R -+--, Ith11AUM
24"
MINIMUM FOOT-iNG SIZE UNDER
OPENING IS 12- x 12'
$REWVW.;�
FIGURE R602.10.6.1
METHOD ABW—ALTERNATE BRACED WALL PANEL
(s) Figure R602.10.6.2 of the 2016 Edition of the California
Residential Code is hereby amended to read as follows:
- 78 -
FxrF A r OF FF;rt+f, :;I H I I-, R-l. 11, PoR'k FkA IES , [4"O PkA,-,HI 211AL I PX4F
vx1-upl:_4;* I=lF Im K F-120ft, 4 N,W
FINtSVED YdD-H Cf OP17-111N.0
�I`Ok SIN,;4f- OR W-Ilt -A F PC* 7k, -- - "'
VIN ?x NET FEAW R !�'EULFIFAL't R PROHIBI 7 Ful
IF PI i% CA- 'IAL-,K S ID(-.+ HEAVE R
`—FASIFNIFEFik HINC, [01-IFAPFF,`. l FW
1 D,0-11 SIDES OF ^PENINC
VIrl. DC{ aLr -N1 F �^,')%T PF 1) WF-1- WIN
",,)Of, ",_RL. (JRA. W%1JFI_ SPFATEIV�
Nl H 6'14) 4,49. NAL S A-
C_.C. IN A�L I`Ki;rv1 INC iSTL115.
SIL, ' ' FYP
VINI F N (13 Tk t7f Ff R - "%9,1 f R.;if. - I' !i
'Mr, )� .35�'.') 1 �' 'RAF - 'Ft 1 1) 4"',"`VVI
'I viil 4 1
k! IN,. REINFtiRCII,;: OF FUND.A-I*_%N, ONE #4 -34R
OF AND -5('T-rkYl 1F FCXTlNn 'P
VIN. I:L
[EVZ110% s I F41w PER
C.PP---SrrE SIDE C 17-
SEE.', -FIN k-:':
If Nt f PI` 1) F.04 ,
N Alt E I I 10 CA' ' ,0-J1I%CV11IF1% TEE
','lt)D_ F 14' .'21` -f-f-
POR-M EG EFK7HT
JNL Of 21, au .
NAlt IN ' IS kF041-WHI
IN EACH- PANE
I YFII.-,At- V',-jHIAL
FRS AF "O%R 8L.,-I'0N
VIN F'�OANC N/lF ONVER CIFF NINO IS 12'X''
VIN
T:
FRONT ELEVATION SECTION
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.
FIGURE R602.10.6.2
METHOD PFH—PORTAL FRAME WITH HOLD-DOWNS
AT DETACHED GARAGE DOOR OPENINGS
F,%',-YN STUD
TO FEACERWITV 6
—F;ks F% k_-W
P _a-E T C
FEADER"NI-V
, �.Vcl
RCAqS OF 15D
TR NN, 5;%T
31 C__ 3. _P_
I�22!
10V A4 Nq000
'R Rt-C LkAt,
PA%E_
St,E,i;7-I,vAC
- 79 -
(t) Table R602.10.5 of the 2016 Edition of the California
Residential Code is hereby amended to read as follows:
TABLE R602.10.5
MINIMUM LENGTH OF BRACED WALL PANELS
WNWJPA LENGTH"
Onchas)
MET140D
CONTREWING, LENGTH
cable R602.10.4)
Wall FlekjM limhes)
8 ftet 9 fwt 10 feet 11 feet 12 feet
DAB. ""SP. SF'B, PBS- PCP. HPS. BV WSP
48
48
�18
5
58 Actuali"
F'.
4 R
48
48
Double sided Actua I
Skied= 0, 5 Acwn I
LIB
Sj
62
0
NP
Np ictuat
SIX A- B and C. ultimate
design
L8
32
34
38
42
ABW
%Aind speed -. 140 mph
D-,- ultlill-Av D(- Do. D1 �)rxl -
48
design
32
32
4
N P
N P
sl*p(l -- 140 T11l)h
PFH
suppurting 1-o(I util%
46
4-6 2 11
44, 21
4+l4 L-L
%1441- � 48
[poting onp story And rT -of
24
Z4
24
27'
)91 48
PFC,
'A
27
C!
nl
15 Actual
CS-C,
24
27
Cs -pp
- and
S A, b
16
is
2�
24 I "i Artuall'
SLC Dj. D , and D;,
44
4-9
21P 21
mRru Z-_I:
2T' Artuall,
Adjacent clear opening,, hEight
(inches)
---64
24
27
'0
3s
3f;
36
26
27
16
72
27
21
10
32
r)
10
29
4
37
JZ
30
--,'0
36
3G
84
35
32
112
88
W
43
37
"1
36 i
49
41
("SAVSr. Cs SIFT,
38
100
--
44
40
J8
39 Actualt
104
49
4.1
4G
41
I OR
54
46
47
41
451
112
11 G
--
,0
5 -5
4`
48
'18
120
lit
52
51
124
V
54
IZA
61
58
U:
62
140
72
- 80 -
1�or `+1 I iii» h = '-A 1111 [1 1 304 8 ntirt, I itnle p?t Will < ti 4 4", ni ;
NP - Not Permitted.
a Lear interpolauan shall h-e permitted
[Ji e tlir joutil lenglh r�°heie it i5 giValer than )I "tual U) fire Ii)6iiinuni leIgfl ,
Maximum header heipjil for PFI� is li) teet in an_rrdance with I iV17e RfAl2_10.6.2. hutwall height shall h� peracnCted to he irt-reased to 12 feet A-ith Ponw wall_
I ).,Iarimuni ol:w ling lieighr 1o3i PF, is 10 ter+ in a xewbm-e Air fiigurr R611L, If, 6 3 1 1 rwiglit s WII to pi-Intirre. I K, I)- ir12 t"r IvithPmr"'•`:'nll
!.Larimunut�f�rid�rg li igtu tau C"S PF i, Ifl ('re IFig"m R14)% It, G 4, teII w;i111ieigliI'hall br t» 1111W,I I- Ic IIN_IT t>Mi.I I'j I? f"I With Imnry nvalI
(u) Section R602.10.2.3 of the 2016 Edition of the
California Residential Code is hereby amended to read as follows:
R602.10.2.3 Minimum number of braced wall panels. Braced wall
lines with a length of 16 feet (4877 mm) or less shall have a minimum
of two braced wall panels of any length or one braced wall panel equal
to 48 inches (1219 mm) or more. Braced wall lines greater than 16 feet
(4877 mm) shall have a minimum of two braced wall panels. No braced
wall panel shall be less than 48 inches in length in Seismic Design
Category Do, Di, or D2.
(v) Figure R602.10.6.4 of the 2016 Edition of the California
Residential Code is hereby amended to read as follows:
- 81 -
E,. fE'.'..'%-'v.0 E✓ ,\ -S+'1 f>lE =P 1,�_=Rh',,E
-CP. EI•GLE QR D'JU 6LE PC='°L
'cft?ICt1 3'RAP f F
n tiT FACE
{ ♦ +`y
LHEADER
STEEL °R KSYTED
_. .,t �.r•L. r
J,� eL.:y
CSTE� 3•EAi yl' E?D eR 11w r
ki=
-_ J•.. l }. �.L.. ILEC 8rw. • L5 4 . _=C
P--TEP.\,55n
.5
I IEEDGC' a -EL
{
wE? E TC PEP R-
< ({{
5 _
R!A 1C t19CT`+ 10 Si 'PE�Nf
iT =IE^�J
PP .SItES E� MEa..+fi3
FS :<
1.f1. HLE ..a }L1- O.E :ITH It�i
F r' t��•�_
r r
15I32^ cF nc_c c N 2A-
L'
5-1.iH -.0 di Ii43C _Or t,G.+CP L -I , D
W.EL =OGE
81tll� t'S C- 4SL:-RM !� 4P C5
_
ens n w+c =_ue r�P
t1'• _E`:a --::c FCNEL =EFT-ELt-S-'..
S
"D Al,.ETERAtl NCP9 L _
- ti UBiE C'
$TABLED D-ER R.J
-ER 3•'x3 z0 �29"
B£ `
:.N:-'A i,LTS PEG
OVER CONCRETE OR UASONRY BLOCK FOUNUA TION EE-.Tl,, P.a e
.3 I twE J= Z
aT-rlueA. - u-EAr..',, •dE4.u'F'F." _ savao=a,te.CG*
OVER RAISED WOOD FLOOR FRAIMNC ANCHOR OPTION
IIG C,:U—I LA=DER ii-= U= R6.1 _FISTi
D A 4C TL R.'1
_ 0••1 EL �YeATMN. cP'..AFSE-.Iv.1.
�T
8A .'. .+..ST NI
' — '�P..'i: K! Tom•.,
I
T
.Y --, 1 R1 .Pt':EL I-E=.rw-1G1 EA, :Wa.'.`..t d-v C:i=Rn.
O RA SEU WOOD FLOOR OVERLAPOPTION
^�-<.'-AT+14_tAPS
FRtXJT cL::,'AT �)N SE'� IOfJ
For SL J inch T mm. I Idol = ',(M 8 mm.
FIGURE R602.10.6.4
METHOD CS-PF-CONTINUOUSLY SHEATHED PORTAL FRAME PANEL CONSTRUCTION
"A,7,-N T PFt_ATE T^
-FACER -ND
I.'s's J 6 SNFZ.
15l32"
ET?_: A.M.=AtiEL
SKEF"H r.G
.A l SLLE
E. PE. - 'e
F8
Rro;z'
�E-lnuGsr
`.L SOLE
FLA'E TC JO*-
FE? -AS-E
(w) Section R606.4.4 of the 2016 Edition of the California
Residential Code is hereby amended to read as follows:
R606.4.4 Parapet walls. Unreinforced solid masonry parapet
walls shall not be less than 8 inches (203 mm) thick and their height
shall not exceed four times their thickness. Unreinforced hollow unit
masonry parapet walls shall be not less than 8 inches (203 mm) thick,
and their height shall not exceed three times their thickness. Masonry
- 82 -
parapet walls in areas subject to wind loads of 30 pounds per square
foot (1.44 kPa) or located in Seismic Design Category Do, D1 or D2, or
on townhouses in Seismic Design Category C shall be reinforced in
accordance with Section R606.12.
(x) Section R606.12.2.2.3 of the 2016 Edition of the
California Residential Code is hereby amended to read as follows:
R606.12.2.2.3 Reinforcement requirements for masonry
elements. Masonry elements listed in Section R606.12.2.2.2 shall be
reinforced in either the horizontal or vertical direction as shown in
Figure R606.11(3) and in accordance with the following:
1. Horizontal reinforcement. Horizontal joint reinforcement
shall consist of at least one No. 4 bar spaced not more than 48 inches
(1219 mm). Horizontal reinforcement shall be provided within 16 inches
(406 mm) of the top and bottom of these masonry elements.
2. Vertical reinforcement. Vertical reinforcement shall
consist of at least one No. 4 bar spaced not more than 48 inches (1219
mm). Vertical reinforcement shall be within 8 inches (406mm) of the
ends of masonry walls.
(y) Exception to Section R602.3.2 of the 2016 Edition of the
California Residential Code is hereby amended to read as follows:
Exception: In other than Seismic Design Category Do, D1 or
D2, a single top plate used as an alternative to a double top plate
shall comply with the following:
1. The single top plate shall be tied at corners, intersecting
walls, and at in -line splices in straight wall lines in
accordance with Table R602.3.2.
2. The rafters or joists shall be centered over the studs with a
tolerance of not more than 1 inch (25 mm).
3. Omission of the top plate is permitted over headers where the
headers are adequately tied to adjacent wall sections in
accordance with Table R602.3.2.
(z) Table R602.3.2 of the 2016 Edition of the California
Residential Code is hereby amended to read as follows:
TAMk QW2.32
SINGLE TUp 91LA 1 L SPUCE CONNEC 1*4 UE TAILS
catawle"
mv-m air snlcr iocAwn"
LOPM&S NW ifewls aawo Nab
"Iums SSl so Awt ALWf
�'a`'/ v l,r.
Mto"M roft
aa[r'+ d4a d ►drn
SI'a,. pri ten.
n#.5
a>re n .�aa ut j ail�t
�t.�.y=�.1ax i.e� v.+cthL+r:..ad-•wr1..�i+a:
•
.�l_ti lutri:1 .�:� I;il.i.
Yl'i ncl I)>>,
i�iY 1I'•il:fil.
and ilt�+re1 ,u ri I�i�.
� I
t i � •fir; +x�*.
.1•Y 1 '.1':Itl+
W40-
hraero w9of WW� *%.W" woo
il.�/
MM'011(M. d w "-# MNIr
7 JL a+•L-♦• �t+e4�+
Piew�?L';
X
(aa) Section R803.2.4 of the 2016 Edition of the California
Residential Code is hereby added to read as follows:
R803.2.4 Openings in horizontal diaphragms. Openings in
horizontal diaphragms shall conform with Section R503.2.4.
(bb) Section R1001.3.1 of the 2016 Edition of the California
Residential Code is hereby amended to read as follows:
R1001.3.1 Vertical reinforcing. For chimneys up to 40 inches
(1016 mm) wide, four No. 4 continuous vertical bars adequately anchored
into the concrete foundation shall be placed between wythes of solid
masonry or within the cells of hollow unit masonry and grouted in
accordance with Section R609. Grout shall be prevented from bonding
with the flue liner so that the flue liner is free to move with thermal
expansion. For chimneys more than 40 inches (1016 mm) wide, two
additional No. 4 vertical bars adequately anchored into the concrete
foundation shall be provided for each additional flue incorporated into
the chimney or for each additional 40 inches (1016 mm) in width or
fraction thereof.
- 84 -
SECTION 33
Section 24.106 of Article XIV, Chapter 24,
Building and Construction, of the Code of the City of Vernon is amended
to read as follows:
Sec. 24.106. 2016 California Green Building Standards Code
adopted. The City of Vernon hereby adopts by reference the 2016
California Green Building Standards Code, also known as CALGreen Code,
as published by the California Building Standards Commission,
California Code of Regulations, Title 24, Part 11, including applicable
tables, indices, appendices, addenda and footnotes. The voluntary
provisions in Appendix Chapter A-4 and Chapter A-5 are not adopted as
mandatory compliance features at this time. Except as otherwise
provided herein, or as later amended, said California Green Building
Standards Code is hereby referred to and by such reference is
incorporated herein as if fully set forth and is hereby adopted by
reference as the Green Building Standards Code of the City of Vernon.
SECTION 34: Section 24.107 of Article XIV, Chapter 24,
Building and Construction, of the Code of the City of Vernon is amended
to read as follows:
Sec. 24.107. Green Building Standards Code amendments,
additions, and deletions.
The 2016 Edition of the California Green Building Standards
Code is hereby amended as follows:
(a) Section 101.12 is hereby added to the 2016 California
Green Building Standards Code to read as follows:
101.12 Green building standards permit fee. Green Building
Standards permit fees shall be set forth in a fee schedule adopted by
resolution of the City Council.
A reinspection fee may be assessed for each inspection or
- 85 -
reinspection when such portion of the work for which an inspection is
called is not complete or when corrections called for are not made.
Reinspection fees may be assessed when the inspection record
card is not posted or otherwise available at the work site, the
approved plans are not readily available to the inspector, for failure
to provide access on the date and time for which the inspection is
requested, or for deviating from the plans requiring the approval of
the building official.
In instances where reinspection fees have been assessed, the
city may deny additional inspection of the work until the required fees
are paid.
(b) The definition of "sustainability" is hereby added to
Section 202 of the 2016 Edition of the California Green Building
Standards Code in alphabetical order to read as follows:
SUSTAINABILITY. Consideration of present development and
construction impacts on the community, the economy, and the environment
without compromising the needs of the future.
(c) Section 301.1 of the 2016 Edition of the California
Green Building Standards Code is hereby amended to read as follows:
301.1 Scope. Buildings shall be designed to include the green
building measures specified as mandatory in this code. Voluntary green
building measures are also included in this code and the application
checklists and may be included in the design and construction of
structures covered by this code, but are not required unless they are
adopted by a city or county as specified in Section 101.7.
(d) Section 301.1.1 of the 2016 Edition of the California
Green Building Standards Code is hereby amended to read as follows:
301.1.1 Additions and alterations. [HCD] The mandatory
provisions of Chapter 4 shall be applied to additions or alterations of
existing residential buildings. Code sections relevant to additions and
alterations shall only apply to the portions of the building being
added or altered within the scope of the permitted work.
Note: On and after January 1, 2014, residential buildings
undergoing permitted alterations, additions or improvements shall
replace noncompliant plumbing fixtures with water -conserving plumbing
fixtures. Plumbing fixture replacement is required prior to issuance of
a certificate of final completion, certificate of occupancy or final
permit approval by the local building department. See Civil Code
Section 1101.1, et seq., for the definition of a noncompliant plumbing
fixture, types of residential buildings affected and other important
enactment dates.
(e) Section 5.408.3 of the 2016 Edition of the California
Green Building Standards Code is hereby amended to read as follows:
5.408.3 Excavated soil and land clearing debris [BSC] 100
percent of trees, stumps, rocks and associated vegetation and soils
resulting primarily from land clearing shall be reused or recycled. For
a phased project, such material may be stockpiled on site until the
storage site is developed.
Exception: Reuse, either on -or off -site, of vegetation or
soil contaminated by disease or pest infestation.
Notes:
1. If contamination by disease or pest infestation is
suspected, contact the County Agricultural Commissioner
and follow its direction for recycling or disposal of
the material. (www.cdfa.ca.gov/exec/
county/county contacts.html)
- 87 -
2. For a map of known pest and/or disease quarantine zones,
consult with the California Department of Food and
Agriculture. (www.cdfa.ca.gov)
3. Contaminated soil shall not be reused and shall be
disposed of or remediated in accordance with relevant
regulations.
(f) Section A4.105.2 of the 2016 Edition of the California
Green Building Standards Code is hereby amended to read as follows:
A4.105.2 Reuse of materials. Use salvaged, refurbished or
reused materials for a minimum of 2.5 percent of the total value, based
on estimated cost of materials on the project. Materials which can be
easily reused include but are not limited to the following:
1. Light fixtures
2. Plumbing fixtures
3. Doors and trim
4. Masonry (reused masonry may only be used for flatwork)
5. Electrical devices
6. Appliances
7. Foundations or portions of foundations
Note: Reused material must be in compliance with the
appropriate Title 24 requirements.
(g) Section A4.106.5, Table A4.106.5.1(1), Table
A4.106.5.1(2), Table A4.106.5.1(3) and Table A4.106.5.1(4) of the 2016
Edition of the California Green Building Standards Code are hereby
amended to read as follows:
A4.106.5 Cool roof for reduction of heat island effect.
Roofing materials for Tier 1 and Tier 2 buildings shall comply with
this section.
TABLE A4.106.5.1(1)
TIER 1 - LOW-RISE RESIDENTIAL
MINIMUM 3-YEAR
SOLAR
ROOF
CLIMATE
AGED SOLAR
THERMAL
REFLECTANCE
SLOPE
z4WE
REFLECTANCE
EMITTANCE
INDEX
£ 2:12
5
0.63
0.75
75
> 2:12
4Q-15
0.20
0.75
16
TABLE A4.106.5.1(2)
TIER 2 - LOW-RISE RESIDENTIAL
MINIMUM 3-YEAR
SOLAR
ROOF
CLIMATE
AGED SOLAR
THERMAL
REFLECTANCE
SLOPE
ZONE-
REFLECTANCE
EMITTANCE
INDEX
2 2:12
2-, 4 0-4-5
0.68
85
82
> 2:12
2-,4�--4,5
0.28
85
27
TABLE A4.106.5.1(3)
TIER 1 - HIGH-RISE RESIDENTIAL
BUILDINGS. HOTELS. AND MOTELS
MINIMUM 3-YEAR
SOLAR
ROOF
CLIMATE
AGED SOLAR
THERMAL
REFLECTANCE
SLOPE
ZON€
REFLECTANCE
EMITTANCE
INDEX
£ 2:12
10&41;
44-15
0.63
0.75
75
> 2:12
2 -- -5
0.20
0.75
16
TABLE A4.106.5.1(4)
TIER 2 - HIGH-RISE RESIDENTIAL
RU1LDINGS_ HOTELS_ AND MOTELS
MINIMUM 3-
YEAR AGED
SOLAR
ROOF
CLIMATE
SOLAR
THERMAL
REFLECTANCE
SLOPE
ZONE
REFLECTANCE
EMITTANCE
INDEX
2 2:12
2 -45
0.68
0.85
82
> 2:12
2--1-5
0.28
0.85
27
(h) Section A4.303.4 of the 2016 Edition of the California
Green Building Standards Code is hereby amended to read as follows:
A4.303.4 Nonwater supplied urinals and composting toilets.
Nonwater supplied urinals or composting toilets are installed
throughout the scope of the permit or comply with Sections 1101.1 thru
1101.8 of the California Civil Code, whichever is the most restrictive.
Where approved, hybrid urinals, as defined in Chapter 2,
shall be considered waterless urinals.
�>�
(i) Section A4.404.3 of the 2016 Edition of the California
Green Building Standards Code is hereby amended to read as follows:
A4.404.3 Building systems. Use premanufactured building
systems to eliminate solid sawn lumber whenever possible. One or more
of the following premanufactured building systems is used throughout:
1. Composite floor joist or premanufactured floor framing
system
2. Composite roof rafters or premanufactured roof framing
system
3. Panelized (SIPS, ICF or similar) wall framing system
4. Other methods approved by the enforcing agency
(j) Section A4.405.1 of the 2016 Edition of the California
Green Building Standards Code is hereby amended to read as follows:
A4.405.1 Prefinished building materials. Utilize prefinished
building materials which do not require additional painting or
staining. One or more of the following building materials that do not
require additional resources for finishing are used:
1. Exterior trim not requiring paint or stain
2. Windows not requiring paint or stain
3. Siding or exterior wall coverings which do not require
paint or stain
(k) Section A4.405.4 of the 2016 Edition of the California
Green Building Standards Code is hereby amended to read as follows:
A4.405.4 Use of building materials from rapidly renewable
sources. One or more of the following materials manufactured from
rapidly renewable sources or agricultural by-products is used for a
minimum of 2.5 percent of the total value, based on estimated cost of
materials on the project:
".�M
1. Insulation
2. Bamboo or cork
3. Engineered products
4. Agricultural based products
5. Other products acceptable to the enforcing agency
Note: The intent of this section is to utilize building
materials and products which are typically harvested within a 10-year
or shorter cycle.
(1) Section A4.407.1 of the 2016 Edition of the California
Green Building Standards Code is hereby amended to read as follows:
A4.407.1 Drainage around foundations. Install foundation and
landscape drains which discharge to a dry well, sump, bioswale or other
approved on -site location except when not required by state code or
locally approved ordinance.
(m) Section A5.106.4.1 of the 2016 Edition of the California
Green Building Standards Code is hereby amended to read as follows:
A5.106.4.1 Short-term bicycle parking. If the project is
anticipated to generate visitor traffic, provide permanently anchored
bicycle racks within 200 feet of the visitors' entrance, readily
visible to passers-by, for 15 percent of visitor motorized vehicle
parking capacity, with a minimum of one two -bike capacity rack.
(n) Table A5.106.4.3 of the 2016 Edition of the California
Green Building Standards Code is hereby amended to read as follows:
A5.106.4.3 Changing rooms. For buildings with over 10 tenant -
occupants, provide changing/shower facilities for tenant -occupants only
in accordance with Table A5.106.4.3 or document arrangements with
nearby changing/shower facilities.
- 91 -
TABLE A5.106.4.3
NUMBER
OF
SHOWER/CHANGING
TENANT-
FACILITIES REQUIRED
OCCUPANT
0-10
1 unisex shower
11-50
1 unisex shower
51-100
1 unisex shower
101-200
1 shower stall per gender
1 shower stall per gender for
Over 200
each 200 additional tenant -
occupants
2-TIER (12" X 15" X
72") PERSONAL
EFFECTS LOCKERS
REQUIRED
1
2
3
4
One 2-tier locker for
each 50 additional
tenant -occupants
Note: Additional information on recommended bicycle
accommodations may be obtained from Sacramento Area Bicycle Advocates
(o) Section A5.106.6.1 of the 2016 Edition of the California
Green Building Standards Code is hereby amended to read as follows:
A5.106.6.1 Reduce parking capacity. With the approval of the
enforcement authority, employ strategies to reduce on -site parking area
by 20% by:
TMAs.
1. Use of on street parking or compact spaces, illustrated
on the site plan; or
2. Implementation and documentation of programs that
encourage occupants to carpool, ride share or use
alternate transportation.
Note: Strategies for programs may be obtained from local
(p) Section A5.406.1 of the 2016 Edition of the California
Green Building Standards Code is hereby amended to read as follows:
A5.406.1 Choice of materials. Compared to other products in a
given product category, choose materials proven to be characterized by
one or more of the following for a minimum of 5 percent of the total
value, based on estimated cost of materials on the project.
- 92 -
SECTION 35: Section 24.108 of Article XV, Chapter 24,
Building and Construction, of the Code of the City of Vernon is amended
to read as follows:
Sec. 24.108. 2016 California Energy Code adopted. The City of
Vernon hereby adopts by reference the 2016 California Energy Code, as
published by the California Building Standards Commission, California
Code of Regulations, Title 24, Part 6, including all of its tables,
indices, appendices, addenda and footnotes subject, however, to the
amendments, additions and deletions set forth in this article. Except
as otherwise provided herein, or as later amended, said California
Energy Code is hereby referred to and by such reference is incorporated
herein as if fully set forth as the Energy Code of the City of Vernon.
SECTION 36: Section 24.109 of Article XV, Chapter 24,
Building and Construction, of the Code of the City of Vernon is amended
to read as follows:
Sec. 24.109. Energy Code amendments, additions, and
deletions. The 2016 California Energy Code is amended as follows:
(a) Paragraph (i) is hereby added to Section 100 of the 2010
California Energy Code to read as follows:
(i) Energy permit fee. Energy permit fees shall be set forth
in a fee schedule adopted by resolution of the City Council.
A reinspection fee may be assessed for each inspection or
reinspection when such portion of the work for which an inspection is
called is not complete or when corrections called for are not made.
Reinspection fees may be assessed when the inspection record
card is not posted or otherwise available at the work site, the
approved plans are not readily available to the inspector, for failure
to provide access on the date and time for which the inspection is
- 93 -
requested, or for deviating from the plans requiring the approval of
the building official.
In instances where reinspection fees have been assessed, the
city may deny additional inspection of the work until the required fees
are paid.
SECTION 37: Findings and Justifications. Findings of fact
and justifications of the City Council of the aforementioned amendment
that justify local amendments to the California Building Standards
Code, Title 24 CCR, on the basis of specific local climatic,
topographic or geologic conditions and submitted to the City Council
under separate cover for approval.
SECTION 38: Ordinances Repealed. Any ordinance, part of an
ordinance, or code section in conflict with this Ordinance is hereby
repealed.
SECTION 39: Severability. If any chapter, article, section,
subsection, subdivision, paragraph, sentence, clause, or phrase or word
of this Ordinance or any part thereof is for any reason held to be
unconstitutional or invalid or ineffective by any court of competent
jurisdiction, such decision shall not affect the validity or
effectiveness of the remaining portions of this Ordinance or any part
thereof. The City Council hereby declares that it would have adopted
this Ordinance and each chapter, article, section, subsection,
subdivision, sentence, clause or phrase thereof, irrespective of the
fact that any one or more chapters, articles, sections, subsections,
subdivisions, clauses, paragraphs, sentences, clauses, phrases or words
be declared unconstitutional, or invalid, or ineffective.
SECTION 40: Effect of Code on Past Actions and Obligations.
The adoption of this Ordinance does not affect any civil lawsuit
- 94 -
instituted or filed or prosecutions for ordinance violations committed
on or prior to the effective date of this Ordinance, does not waive any
fee or penalty due and unpaid prior to the effective date of this
Ordinance and does not affect the validity of any bond or cash deposit
posted, filed or deposited pursuant to the requirements of any
ordinance.
SECTION 41: References to Prior Code. Unless superseded and
expressly repealed, references in City forms, documents and regulations
to the chapters and sections of the former Ordinance No. 1217, shall be
construed to apply to the corresponding provisions contained within
this Ordinance. Ordinance No. 1217 of the City of Vernon, and all other
ordinances or parts of ordinances, in conflict herewith are hereby
superseded and expressly repealed.
SECTION 42: Penalty. Unless otherwise provided in the Vernon
Municipal Code, any person violating any provision of this Ordinance
shall be guilty of a misdemeanor and upon conviction thereof, shall be
punished by a fine not exceeding one thousand dollars, or by
imprisonment in jail for a term not exceeding six months, or both such
fine and imprisonment.
SECTION 43: Copies on File with City Clerk. Pursuant to
Government Code Section 50022.6, one certified copy of each of the
following: 2016 Fire Code, 2016 California Building Code, 2016
California Electrical Code and 2006 Edition of the ICC Electrical Code
Administrative Provisions, 2016 California Mechanical Code, 2016
California Plumbing Code, 2016 California Existing Building Code, 2015
International Existing Building Code, 2016 California Residential Code,
2016 California Green Building Standards Code, and 2016 California
Energy Code shall be made available for public inspection in the Office
- 95 -
of the City Clerk.
SECTION 44: Book of Ordinances. The City Clerk, or Deputy
City Clerk, shall attest and certify to the adoption of this Ordinance
and shall cause this Ordinance and the City Clerk's, or Deputy City
Clerk's, certification to be entered in the Book of Ordinances of the
Council of this City. The City Clerk, or Deputy City Clerk, shall cause
this ordinance to be published or posted as required by law.
SECTION 45: Effective Date. This ordinance becomes effective
and shall be in full force on the thirty-first day after the passage
thereof; provided, however that where complete plans for buildings have
been filed and are pending for building permits prior to the effective
date of this Ordinance, permits may be issued, and the applicant may
proceed with the construction in strict compliance with Ordinance No.
1237, provided however that physical construction is started within one
hundred eighty (180) days from the date of issuance of the permit and
continued to completion according to said Ordinance No. 1237.
APPROVED AND ADOPTED this 6th day of December, 2016.
Name: William J. Davis
Title: Mayor / Mayam
-7 T:
.�.�G
M ria E . A ala
City Clerk
APPROVED AS TO FORM:
Brian Byun, De �fy City Attorney
STATE OF CALIFORNIA )
) ss
COUNTY OF LOS ANGELES )
I, Maria E. Ayala , City Clerk / Deputy City Gleic'' of the
City of Vernon, do hereby certify that the foregoing Ordinance, being
Ordinance No. 1237 was duly and regularly introduced at a regular
meeting of the City Council of the City of Vernon, held in the City of
Vernon on Tuesday, November 15, 2016, and thereafter adopted at a
meeting of said City Council held on Tuesday, December 6, 2016, by the
following vote:
AYES: Councilmembers: Mayor Davis, Mayor
Pro-Tem Woodruff -Perez,
Lopez, Martinez, Ybarra
NOES: Councilmembers: None
ABSENT: Councilmembers: None
And thereafter was duly signed by the Mayor or Mayor Pro-Tem of
the City of Vernon.
Executed this_7�_ day of
California.
(SEAL)
December , 2016, at Vernon,
- 97 -
Ma is E. Aya
City Clerk / 9epidty Git y G errk
TRANSMITTAL COMMUNICATION
CITY CLERK'S OFFICE
INTEROFFICE MEMORANDUM
DATE: December 8, 2016
TO: Derek Wieske, Director of Public Works, Water & Development Services A .
FROM: Deborah Juarez, Records Management Assistant
RE: Ordinance No. 1237 — An Ordinance of the City Council of the City of Vernon Amending
Various Sections of Chapters 7, Fire Regulations and 24, Building and Construction, of the
Vernon Municipal Code, Along with Amendments, Additions and Deletions and Adopting
by Reference the Following Codes: (1) the 2016 California Fire Code, 24 CCR Part 9; (2)
the 2016 California Building Code, 24 CCR Part 2; (3) the 2016 California Electrical
Code, 24 CCR Part 3 (4) the 2006 Edition of the International Code Council Electrical
Code Administrative Provisions; (5) the 2016 California Mechanical Code, 24 CCR Part 4;
(6) the 2016 California Plumbing Code, 24 CCR Part 5; (7) the 2016 California Existing
Building Code, 24 CCR Part 10; (8) the 2015 International Existing Building Code, (9) the
2016 California Residential Code, 24 CCR Part 2.5; (10 the 2016 California Green
Building Standards Code Also Called the CalGreen Code, 24 CCR Part 11; (11) the 2016
California Energy Code, 24 CCR Part 6; Repealing All Prior Ordinances and Parts of
Ordinances in Conflict Therewith
Transmitted herewith for your transmittal to the State is a certified copy of Ordinance No. 1237
referenced above, which was approved by City Council on December 6, 2016.
Please see that a copy of the transmittal letter is sent to the City Clerk's office for the file.
Thank you.
Claudia Arellano
Andrew Guth
Ordinance No. 1237
CERTIFICATE
STATE OF CALIFORNIA )
) ss
COUNTY OF LOS ANGELES)
I, Maria E. Ayala, City Clerk of the City of Vernon, County of Los Angeles, State of
California, hereby certify that the attached is a full and complete copy of:
Ordinance No. 1237 — An Ordinance of the City Council of the City of Vernon
Amending Various Sections of Chapters 7, Fire Regulations and 24, Building and
Construction, of the Vernon Municipal Code, Along with Amendments, Additions
and Deletions and Adopting by Reference the Following Codes: (1) the 2016
California Fire Code, 24 CCR Part 9; (2) the 2016 California Building Code, 24
CCR Part 2; (3) the 2016 California Electrical Code, 24 CCR Part 3 (4) the 2006
Edition of the International Code Council Electrical Code Administrative
Provisions; (5) the 2016 California Mechanical Code, 24 CCR Part 4; (6) the 2016
California Plumbing Code, 24 CCR Part 5; (7) the 2016 California Existing
Building Code, 24 CCR Part 10; (8) the 2015 International Existing Building
Code, (9) the 2016 California Residential Code, 24 CCR Part 2.5; (10 the 2016
California Green Building Standards Code Also Called the CalGreen Code, 24
CCR Part 11; (11) the 2016 California Energy Code, 24 CCR Part 6; Repealing
All Prior Ordinances and Parts of Ordinances in Conflict Therewith
IN WITNESS WHEREOF, I have hereunto set my hand and affixed the official Seal of
the City of Vernon, County of Los Angeles, State of California, on this 71� day of December
2016.
SEAL:
- Maria E. Ayala
City Clerk