Loading...
Resolution No. 7598r 4 ♦ A r R 1 RESOLUTION NO. 7598 2 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF 3 VERNON APPROVING AND AUTHORIZING NOTICE INVITING SEALED PROPOSALS OR BIDS FOR THE PURCHASE OF 36 4 OVERHEAD DISTRIBUTION TRANSFORMERS AND 28 PADMOUNT TRANSFORMERS TO REPLENISH STOCK FOR ELECTRICAL 5 SERVICE CONSTRUCTION 6 7 WHEREAS, the Utilities Department is in need of 36 Overhead 8 Distribution Transformers and 28 Padmount Transformers to replenish 9 the stock for electrical service construction; and 10 WHEREAS, on August 7, 2000, the Finance Committee recommended 11 to the City Council that authority be granted for the Purchasing 12 Agent, or his designee, to seek formal bids for the purchase of 36 13 Overhead Distribution Transformers and 28 Padmount Transformers; and 14 WHEREAS, there has been presented to the Finance Committee of 15 the City of Vernon a Bid Proposal for the purchase of the 36 Overhead 16 Distribution Transformers and 28 Padmount Transformers; and 17 WHEREAS, the City Council of the City of Vernon has 18 determined that it is in the best interests of the City of Vernon that 19 bids be solicited in accordance with applicable State law and the 20 Vernon City Code. 21 NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE 22 CITY OF VERNON AS FOLLOWS: 23 SECTION 1: The City Council of the City of Vernon hereby 24 finds and determines that the recitals contained hereinabove are true 25 and correct. 26 SECTION 2: The Bid Proposal, which is attached hereto and 27 made a part hereof as Exhibit "A," is hereby approved by the City 28 / / / I Council of the City of Vernon. 2 SECTION 3: The City Clerk of the City of Vernon is hereby 3 directed to give notice, in writing, inviting sealed proposals or bids 4 for the purchase of 36 Overhead Distribution Transformers and 28 5 Padmount Transformers, in accordance with the Bid Proposal, and in 6 accordance with this resolution. 7 SECTION 4: There being no newspaper of general circulation 8 printed, published or circulated in the City of Vernon, the City Clerk 9 is hereby directed to post said notice, or cause the same to be 10 posted, in three of the most public places in the City of Vernon, to 11 wit: the northwest corner of 38th Street and Santa Fe Avenue, the 12 northeast corner of Leonis Boulevard and Pacific Boulevard, and on the 13 bulletin board in the lobby of the City Hall of the City of Vernon, 14 located at 4305 Santa Fe Avenue, in said City. 15 SECTION 5: The City Clerk of the City of Vernon is hereby 16 directed to post said notice forthwith and the first posting of said 17 notice shall be at least ten (10) days before the opening of the bids 18 for the proposed contract. Said notice shall provide that sealed 19 proposals or bids will be received by the City of Vernon at the office 20 of the City Clerk, or his designee, at the City Hall, 4305 Santa Fe 21 Avenue, Vernon, CA 90058-0805. 22 23 24 25 26 27 28 - 2 - A ♦ � 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 SECTION 7: The City Clerk of the City of Vernon shall certify to the passage of this resolution, and thereupon and thereafter the same shall be in full force and effect. APPROVED AND ADOPTED this 8"' day of August, 2000. ATTES BRUCE V. MALKENHORST, City Clerk LEONIS C. MALEtURG, M yor - 3 - I STATE OF CALIFORNIA ) ss 2 COUNTY OF LOS ANGELES ) 3 4 I, BRUCE V. MALKENHORST, City Clerk of the City of Vernon, do 5 hereby certify that the foregoing Resolution, being Resolution No. 6 7598, was duly adopted by the City Council of the City of Vernon at an 7 adjourned regular meeting of the City Council duly held on Tuesday, 8 August 8, 2000, and thereafter was duly signed by the Mayor of the 9 City of Vernon. r/ 10 BRUCE V. MALKENHORST, City Clerk 11 12 (SEAL) 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 - 4 - E"MHIBIT A CIT r OFVERN'ON, CALIFORNIA DEPARTMENT: UTILITIES REQUESTOR NAME: R. ABUEG/AH 1 SUGGESTED VENDOR: l VENDOR ADDRESS: SEE ATTACHED LIST PURCHASE REQUISITION 04813 DATE: 7/31/00 PHONE NO.: ( ) FAX #: CONTACT PERSON: REQUIRED DELIVERY OR SERVICE DATE: DELIVERY OR SERVICE LOCATION: \ACCOUNT NO.: 055-1.00-8300-8500 ITEMS BUDGETED YES_ NO 4 EA OVERHEAD DISTRIBUTION TRANSFORMER 25KVA, 7KV, 120/240V MATERIAL CODE: 001-0251 4 EA OVERHEAD DISTRIBUTION TRANSFORMER 50KVA, 7KV, 120/240V MATERIAL CODE: 001-0501 3 EA OVERHEAD DISTRIBUTION TRANSFORMER 167KVA, 7KV, 120/240V MATERIAL CODE: 001-1672 3 EA OVERHEAD DISTRIBUTION TRANSFORMER 25KVA, 7KV, 277/480V MATERIAL CODE: 001-0252 6 EA OVERHEAD DISTRIBUTION TRANSFORMER 50KVA, 7KV, 277/480V MATERIAL CODE: 001-0502 9 EA OVERHEAD DISTRIBUTION TRANSFORMER 75KVA, 7KV, 277/480V MATERIAL CODE: 001-0752 7 EA OVERHEAD DISTRIBUTION TRANSFORMER 333KVA, 7KV, 277/480V MATERIAL CODE: 001-3332 PAGE 1 OF 2 SCHEDULED DELIVERY DATE: * IF ITEMS ARE NOT BUDGETED, EXPLAIN NATURE OF REQUEST BELOW, OR SUBMIT MEMORANDUM. RE -STOCK DISTRIBUTION TRANSFORMERS FOR ELECTRICAL SERVICE CONSTRUCTION. I hereby certify that the above items are necessary for the operation of this RECEIVED BY 8%1(11; 1�/1711 or Authorized Person PURCHASE ORDER NUMBER PURCHASING nFPART'.AC T r i r APPROVED TRANSFORMER SUPPLIERS CITY OF VERNON SPEC. TR1-1995 Greg Tagliaferri ABB Power c/o Wesco 10020 Freeman Avenue Santa Fe Springs, CA 90670 (562) 903-1380 FAX (562) 941-0634 Morie Hively Central Moloney c/o Southcoast Utility Sales 8762 Luss Drive Huntington Beach, CA 92646 (714)962-0841 FAX (714) 963-2487 Ron Kirker Cummins Utility Supply 44-909 Golf Center Pkwy., #12 Indio, CA 92201 (760)775-7533 FAX (760) 775-7433 Mr. Mark Christensen General Electric c/o Southwest Power P.O. Box 2337 Santa Fe Springs, CA 90670 (562) 801-4577 FAX (562) 801-4582 Emma A. LeMonde Kuhlman Electric Corp. 101 Kuhlman Road Versailles, KY 40383 (606) 879-2999 FAX (606) 873-2236 1 , � �,. 7 .� t1 • t 3y, t SPECIFICATION NO. TR1-1995 OVERHEAD DISTRIBUTION TRANSFORMERS CITY OF VERNON UTILITIES DEPARTMENT November 16, 1999 Specification No. TR1-1M O.H. Dist. Transformers City of Vemon SPECIFICATION NO. TR1-1995 Approved Manufacturers ABB Power Central Moloney Cooper Power Systems General Electric Company Howard Industries Kuhlman Corporation Approved' ✓(Assistant Director of Engineering & Operations Specification No. TR1-1995 O.H. Dist. Transformers City of Vernon 1.0 SCOPE This specification covers the requirements of the City of Vernon for single-phase, 60 Hz, mineral oil filled, overhead type distribution transformers rated 500 kVA and below. 2.0 APPLICABLE STANDARDS The transformers shall conform to the applicable parts of the latest revisions of the referenced documents listed below. In case of conflicts between this Specification and a referenced document, this Specification shall take precedence over the referenced document. American National Standards Institute (ANSI) ANSI C57.12.00 General Requirements for Liquid -Immersed Distribution, Power and Regulating Transformers. ANSI C57.12.10 Requirements for Transformers 230,000 Volts and Below, 833/958 through 8,333/10,417 kVA Single -Phase, and 7501862 through 60,000/80, 000/100, 000 kVA Three -Phase. ANSI C57.12.20 Requirements for Overhead -Type Distribution Transformers, 67,000 Volts and Below, 500 kVA and smaller. 3.0 TEMPERATURE RISE The temperature rise of the windings at rated voltage and kVA shall not exceed 65 °C above an ambient of 400C when measured by the resistance method. The hot spot temperature rise shall not exceed 80°C. The temperature rise of the oil shall not exceed 650C when measured near the top of the tank. 4.0 CORE DESIGN Transformer cores shall be silicon steel, amorphous iron cores are not acceptable. 5.0 HIGH VOLTAGE TAPS All high -voltage taps shall be full -capacity taps. Unless otherwise specified by the City of Vernon in writing, transformers shall be supplied with high -voltage taps as listed in Table I. 6.0 WEIGHTS AND DIMENSIONS A. The maximum weight for transformers 100 kVA and below shall be 1,400 lbs. Specification No. TR1-1995 1 O.H. Dist. Transformers City of Vernon B. All 250, 333, and 500 kVA single-phase transformers shall be "lightweight" transformers. The weights and dimensions of the "lightweight" transformers shall not exceed the weights and dimensions specified below. Rating Weight lbs. Height Inches Width Inches Depth Inches _MA 250 2,500 72 41 38 333 2,800 72 41 38 500 3,300 1 72 50 42 7.0 TRANSFORMER ACCESSORIES A. The arrangement of accessories on all single-phase transformers rated 167 kVA and below, with standard voltages -and kVA ratings, shall be as specified in ANSI C57.12.20, except that transformers with 277 volt secondary windings shall have a tank grounding provision. B. The mechanical arrangement of accessories on single-phase "lightweight" transformers rated above 167 kVA shall be as follows: 1. Support brackets are not required on any of the single-phase "lightweight" transformers. 2. The arrangement of accessories on all single-phase, "lightweight" transformers rated above 167 kVA, with standard voltage and kVA ratings, shall be the same as normally furnished on single-phase transformers rated 167 kVA. 3. The arrangement of accessories on all single-phase, "lightweight" transformers rated above 167 kVA, with nonstandard kVA ratings or nonstandard voltage ratings, or both, shall be either as specified in ANSI C57.12.20 for 12,000 or 16,340 volt transformers, or as specified above in section 7.0.13.2. 8.0 TANKS AND COVERS Welded tank covers are not acceptable on single-phase transformers. 9.0 HIGH -VOLTAGE BUSHINGS A. Transformers rated 15 kVA through 167 kVA shall be furnished with two cover -mounted bushings. High voltage bushing terminals shall be in accordance with ANSI Standard C57.12.20-1988, Paragraph 6.1.2.2. Specification No. TR1-1995 O.H. Dist. Transformers City of Vernon 2 B. The cover -mounted bushings shall be of the 15 kV insulation lass. The creepage distance of the bushings shall be not less than 15 inches. C. When the distance between live parts of cover -mounted bushings is less than 12 inches, the bushings shall be equipped with approved bird guards. Bird guards that are approved for use on overhead transformers are: Manufacturer Model_ Number Coltec Industries 703803-53 Porcelain Products 65001 through 65019 RTE 0704119BOl Kuhlman Electric 6210209902 assembly 6210208804 assembly 10.0 INTERNAL HIGH -VOLTAGE CONNECTIONS A. Each internal high -voltage lead shall be equipped with eight a ring -tongue or a hook -type connector. Each connector shall be terminated on a fixed threaded stud, a fixed threaded bolt, or a non -removable threaded bolt, each having two nuts for holding and locking purposes. 1. Ring -tongue type: The ring -tongue terminals shall have mechanical and electrical properties so as to contain the high -voltage leads, without breaking, even under short-circuit conditions.. Burndy type YAV are typical of the type desired. 2. Hook type: Hook terminals shall meet the same physical requirements as specified above for ring -tongue terminals. In addition to the above, both changing and locking nuts shall be held captive to prevent their complete removal. AMP, Inc. Style No. 3, "Hook" terminals are typical of the type desired. 11.0 TAP CHANGERS A. Tap changers shall be in accordance with ANSI C57.12.10 except provision for padlocking is not required. B. Transformer specified with taps shall be equipped with externally operable tap changer handle. C. External operated tap changers shall be clearly and permanently labeled "De -energized Operation Only". Specification No. TR1-1995 O.H. Dist. Transformers City of Vernon 3 12.0 PRESSURE RELIEF DEVICES A. All transformers shall be equipped with an automatic pressure relief device. The valve shall be of the indicating type with weatherproof cover, and equipped with a pull ring for hook -stick operation. It shall have %-inch NPT threads and be located on the tank wall above the oil level in either segment 2 or 4 as designed in ANSI C57.12.20, Table S2. The valve shall meet the following minimum operating characteristics: Cracking Pressure: 10 PSIG Re -seal: 5 PSIG Flow Rates: 50 SCFM at 15 PSIG 100 SCFM at 50 PSIG B. The valve body and various parts of the device shall be corrosion resistant. Only the following pressure relief devices are acceptable. 1. Circle Seal Model No. P60-383 2. Qualitrol Model No. 202-032-01 or 202-33-01 3. Beta Model Nos. 1712K-1, -5, -6, or Model No. 1750K-5. C. Required electrical clearance between pressure relief valve and live parts shall be maintained. 13.0 TANK AND BUSHING FINISHES A. The paint on all transformer tanks shall be grayish in color and conform to Munsell Notation 5BG 7.0/0.4 with the following tolerances: 1. Hue: ±12 (3G to 7B) 2. Value: t0.2 3. Chroms: t0.2 14.0 OIL AND OIL PRESERVATION A. A sealed tank shall be provided on all transformers. B. All oil furnished by supplier shall not contain any detectable trace of polychlorinated biphenyls and shall meet the requirements of ASM Standard D 3487 for mineral insulating oil 15.0 NAMEPLATES A. Each transformer shall have a noncorrosive stainless -steel or anodized aluminum nameplate permanently attached. Adhesive type nameplates Specification No. TR1-1995 O.H. Dist. Transformers City of Vernon 4 are not acceptable. The nameplate shall be secured using non -corrosive metallic fasteners. B. In addition to the nameplate information called for in ANS C57.12.00, the nameplate shall identify each winding as to whether it is made of copper or aluminim. 16.0 LOSS EVALUATION Purchase of transformers shall be evaluated by lowest total ownership cost. The formula used to evaluate annual ownership cost is: TOC = C + (4.47 $/W)PNL + (2.90 $/W)PLL Where TOC is the total ownership cost in dollars, C is the -initial cost in dollars, PNL is the guaranteed maximum no load loss in Watts, and PLL is the guaranteed maximum load loss in Watts. 17.0 RATINGS The standard transformer ratings used by the City of Vernon and covered by this specification are listed in Table I. This list does not preclude the possibility of ordering voltage and kVA ratings not listed under this specification. 18.0 DOCUMENTATION Certified test reports showing quoted losses, individual unit losses, and average losses shall be sent within one month of shipment to: City of Vernon Utilities Department 4305 Santa Fe Avenue Vernon, CA 90058 Attention: Assistant Director of Engineering & Operations Bidders shall provide: a. Guaranteed maximum no-load (excitation) loss at rated voltage in Watts. b. Guaranteed maximum load loss in Watts at rated voltage and kVA. C. Guaranteed maximum total loss in Watts at rated voltage and kVA. d. Percent impedance on rated voltage tap. e. Two sets of outline drawings showing location and description of accessories. Specification No. TR1-1995 O.H. Dist. Transformers City of Vernon 5 � e-e-roor Tp-c NN O V-Ncn 1- 0 .r-N �? 09 444.� 44 M08080000�r-rm- .-V- O O �QtoUALQOtn0~ ��NOtnO��MO Ye- NMU) IT- D .rN��r"r-a-NC7tn >> O }O (O CN c O > d0, IT O COO co 110 O N N U cn cn O a' O s ca C C � LO cn m c cm _ �_ - a� m rn= _ 0 c H co O ti �v > > v cis E a 0 o N a h ti — O UJ J O CD Q N C e-Nm Wrr0 0 r- co a) go cuV- - N01 r T- V- ov-O-M'0U 0 NN C' 09999-- 9O MONNNN8NNNN8NNNNNN"N 00000000 N8 088000 a)Z 8 0 oco r- 0 V- O'qo N r- ro Lo U- 0 r-- 8 1,- (0, C:l 0 Lo [004 m Ct) M 0 0 Ln N 0 m U) -b. 0 OD CCNti 8 CN c. . . . . 0 . CD Lo O O V- q) V- 0) , U) U) Lc) (a V) V- -C >0 "a 4) O U) D CN 0 04 0) V- fl- ICI)l c -i . . . . Lo 2 . . cR E c m —30 'a 0 > qr c w 2! co Co CO E CN 0- 6 W IM CM a. c CITY OF VERNON, CALIFORNIA . ' PURCHASE REQUISITION 0:4810 DEPARTMENT: UTILITIES REQUESTOR NAME: R. ABUEG/AH DATE: 7/31/00 SUGGESTED VENDOR: SEE ATTACHED PHONE NO.: ( ) VENDOR ADDRESS: FAX #: CONTACT PERSON: REQUIRED DELIVERY OR SERVICE DATE: DELIVERY OR SERVICE LOCATION: ACCOUNT NO.: 055-100-8300-8500 ITEMS BUDGETED YES X_ NO 4 EA PADMOUNT TRANSFORMER 225KVA, 7KV, 277/480V 4 EA PADMOUNT TRANSFORMER 500KVA, 7KV, 277/480V 4 EA PADMOUNT TRANSFORMER 1500KVA, 7KV, 277/480V 1 EA PADMOUNT TRANSFORMER 2000KVA, 7KV, 277/480V 3 EA PADMOUNT TRANSFORMER 225KVA, 16KV, 277/480V 1 EA PADMOUNT TRANSFORMER 500KVA, 16KV, 277/480V 2 EA PADMOUNT TRANSFORMER 750KVA, 16KV, 277/480V 2 EA PADMOUNT TRANSFORMER 1000KVA, 16KV, 277/480V 7 EA PADMOUNT TRANSFORMER 2500KVA, 16KV, 277/480V PAGE'ONE OF TWO' SCHEDULED DELIVERY DATE: �k IF ITEMS ARE NOT BUDGETED, EXPLAIN NATURE OF REQUEST BELOW, OR SUBMIT MEMORANDUM. I hereby certify that the above items are necessary for the operation of this Head or 8 z oa Person ISSUED BY DATE RECEIVED BY DATE PURCHASING DEPARTMENT PURCHASE ORDER NUMBER CITY OF'VERN`ON, CALIFORNIA `" PURCHASE REOUISITION 0 B 1.1 DEPARTMENT: UTILITIES SUGGESTED VENDOR REQUESTOR NAME: R. ABUEG/AH DATE: 7/31/00 CCC ATTArurn i T cT PHONE NO.: ( ) VENDOR ADDRESS: FAX #: CONTACT PERSON: REQUIRED DELIVERY OR SERVICE DATE: DELIVERY OR SERVICE LOCATION: ACCOUNT NO.: 055-100-8300-8500 ITEMS BUDGETED YES �_ * NO SEE ATTACHED SPECIFICATION NO. TR2-1992 FOR DETAILS. REFER TO ATTACHED LETTER FOR LIST OF APPROVED VENDORS AND METHOD OF TRANSFORMER QUOTATION SELECTION. DELIVER ON FLATBED TRUCK FOR SIDE UNLOADING BY FORKLIFT AT GROUND LEVEL. PLEASE NOTIFY RMI-US AT 323-589-9498 48 HOURS PRIOR TO DELIVERY. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT TIMOTHY F. BASS AT 323-583-8811, EXTENSION 251. PAGE TWO OF TWO SCHEDULED DELIVERY DATE: * IF ITEMS ARE NOT BUDGETED, EXPLAIN NATURE OF REQUEST BELOW, OR SUBMIT MEMORANDUM. PLEASE SEE ATTACHED MEMO FOR JUSTIFICATION. I hereby certify that the above items are necessary for the operation of this Department ead or Authorized Person ISSUED BY DATE RECEIVED BY �'U RCHASWC3 DFPARTW1 FNT DATE PURCHASE ORDER NUMBER August 1, 2000 TO: Kenneth J. DeDario, Director of Utilities FROM: Ramon Z. Abueg, Assistant Director of Engineering & Operation SUBJECT: Padmount Transformers Below is justification for purchase requisition number 04810 for the padmount transformers: QTY KVA PRIMARY SECONDARY INTENDED USE VOLTAGE VOLTAGE 4 7KV 277/480V 2 — for stock 1225KVA 2 — to replace existing underloaded padmounts 4 7KV 2771480V 2 — for spare 150.0KVA 1 —for Sanberg Furniture 1 — U. S. Growers 4 7KV 277/480V 2 — for CKM 11500KVA 1 — New BW building on 4e 1 — fors are 1 2000KVA 7KV 277/480V 1 —fors are 3 225KVA 16KV 277/480V 1 —for spare 2 — for stock 1 500KVA 16KV 277/480V 1 — fors are 2 750KVA 16KV 277/480V 2 - replacements from Douglas Steel & Ameri ride 2 1000KVA 16KV 277/480V 1 —for spare 1 — Interfresh 2 2500KVA 16KV 277/480V 1 —for Hannibal 1 — for Kai Kan 2 — for Dynamic Builders on 55tn 1 —for Gavina 1 — United Food Groups 1 — fors are Please call me if you have any questions. RZA: ah NOTIFICATION OF CHANGE NO. 1 TO SPECIFICATION NO. TR2-1992 March 31, 1994 To: All Known Holders of Specification TR2-1992 Dead -Front Padmounted Distribution Transformers The following change has been approved and is made part of Specification TR-1992. Please revise your copy as follows: Add the name of Pauwels Transformers, Inc. as a conditionally approved manufacturer. Sincerely, Edward F. LeBlanc, P.E. Electrical Engineering Manager • • • ` !' �,• i : � it • SPECIFICATION NO. TR2-1992 DEAD -FRONT PADMOUNTED DISTRIBUTION TRANSFORMERS CITY OF VERNON LIGHT & POWER DEPARTMENT December 91 1992 � RR SPECIFICATION NO. TR2-1992 Approved Manufacturers Cooper Power ABB General Electric Company Howard Industries . Prepared B / Ali R. Nour Associate Electrical Engineer Approved By: Edward F. LeBlanc, P.E. Electrical Engineering Manager TECHNICAL REOIIIREMENTS 1.0 SCOPE providing three-phase, dead - Supplier shall furnish all work for p Class OA, pad -mounted front, one circuit and two circuit, Class ass 's underground transformers for use on the City brequired are distribution systems. Transformers which may listed in Table 2. 2.0 APPLICABLE STANDARDS A. The transformer shall conform to the application sections. of the following standards to the to the refere ce in this Specification, and as amen are included as part Specification which, by reference, of this Specification: Standard General 1. ANSI/IEEE C57.12.00 Requirements for Liquid - Immersed Distribution, Power, and Regulating Transformers. 2. ANSI C57.12.26 Requirements for Pad -mounted Compartmental -Type, Self Cooled, Three -Phase Distribution Transformers for use with Separable insulated High Voltage Connectors. Pad -mounted Equipment -- 3. ANSI C57.12.28 Enclosure Integrity. ANSI C57.106 IEEE Guide for AcceInsulating Oil 4 Maintenance of in Equipment. p g. ANSI/IEEE 386 separable Insulated Connector Systems for Power Distribution Systems above 60OV. B. In the event of conflict between the codes and standards and this Specification, Supplier shall notify Y of Vernon Light & Power Department and secure a written clarification before proceeding with the work. SPECIFICATION NO, TR2-1992 Padmounted Dist. Txawfommen City of Vemon 3.0 SERVICE CONDITIONS 3.1 Environment A. The transformers shall perform in accordance with all provisions of the Specification while subject to the service conditions specified in, ANSI/IEEE C57.12.00. B. The transformers shall be suitable for 30 years of use on the City of Vernon's electric system when installed in accordance with the service conditions set forth in ANSI/IEEE C57.12.00-1987, section 4.0, in its entirety. 3.2 Seismic and Impact Loadin A. Before and during installation, the transformers shall withstand, without damage, rough handling such as bouncing on a truck when f illed. with insulating medium and impacting against or upon rigid structures at speeds up to five feet per second, and being lifted by two bosses or lifting bolts at any angle. Following these conditions, the transformers shall be capable of - being energized without a pre -operational test. B. After installation and during the 30-year life of transformer, transformer will be subject to occasional earthquake motions (0.2g horizontal and 0.13g vertical) along with significant vibrations from traffic and from adjacent equipment. 3.3 Pre installation Inspection The City of Vernon will, at its discretion, provide a pre -installation inspection of each transformer. 3.4 Operating Duty For its 30-year life, each transformer shall be suitable for operation under short circuit conditions as stated in ANSI/IEEE C57.12.00-1987, Section 7.1. 4.0 RATINGS A. Transformers shall be 60 Hz, class OA with voltage and kVA ratings as shown in Table 2. The high voltage SPECIFICATION NO. M-1992 Padmounted Dist. Transformers 2 City of Vernon 5.0 15 lation class shall be kV with a BIL rating of 95 insu shall be 1.2 kV kV. The low voltage insulation class sha with a BIL rating of 30 kV. l wing: B. Transformer impedance shall not exceed the fol o Maxi um Transforme m edance KVA 75 - 300 3.04.0 500 g.0 750 - 2500 CONSTRUCTION FEATURES 5.1 Taps and Changers O e ation Iden'f'cation and A. tchangers s shall have tap All high Transformers with taps shall operation. full high suitable for de-energ be capable of kVA voltage taps shall operated from capacity. Tap changers shall be and -terminal compartment, and inside the switching- le handle. Tap shall be gang -operated with a sing permanently er operating mechanisms shall be ion Only." Chang De-energ' identified to show " ized operation Decals and stencils are not acceptable. B. P sition ndicatin Name late nameplate The tap changer position indicating t quality. Decals and shall have numerals or nlette�rs that are clearly legible and of a permeable. stencils are not accep 5.2 Oil and Oil Gauge A. li irements specified in The padmounted transformers shall be furnished with oil which meets the r oil, ASTM Standard D 3487 for mineral weight) )gshall except that the DBPC content ( bY, not be less than 0.15. The insulating oil in the equipment shall conform with AN C57.106. BPHCMcAT10N NO. T112-11 3 Padmouated Dist Transformers city of Vernon B. Oil Gauge All transformers shall have a dial -type, magnetic, oil level gauge to provide a positive means of determining the required oil height. The preferred location of the gauge is above the switch handles, to ensure the switch remains under oil. 5.3 Drain and Replacement Provisions Insulating medium drain and replacement provisions shall be furnished as specified in ANSI C57.12.26. 5.4 Transformer Tanks A. The transformer tanks, and all external appurtenances, shall be in accordance with ANSI C57.12.26. B. Transformer tanks shall be within the overall dimensions shown on Exhibits shall C a nd locations of various appurtenancesbe in accordance with these exhibits. C. Transformers shall have bolted handholes and either bolted or welded tank covers. Handholes shall have large enough dimensions to permit inspection and to permit easy replacement of fuseholders, bushings and other accessories. Bolted handholes shall be gasketed. Gasket material shall be Nitrile rubber. Where required, gasket splicing shall be accomplished by using scarfed joints. Butt joints are not acceptable. 5.5 Terminations Transformer bushings shall accommodate cable terminations in accordance with ANSI/IEEE 366. 5.6 Nameplates A stainless steel nameplate shall be attached with noncorrosive hardware to the inside of the low voltage compartment. Viewing the nameplate shall o be obstructed by the low voltage bushings, cables c. Diagrams and numbers shall be of the size and quality such that they can be read from outside the SPECIFICATION NO. TR24M Padmounted Dist. Transformers 4 City of Vemoa compartment. In addition to the nameplate requirements shown in ANSI/IEE C57.12.00-1987, Section 5.12, the total weight, including oil, shall be indicated. 6.0 COATING 6.1 Painting Each transformer and terminal enclosure combination shall be painted a forest green color such as Dulux Bell Telephone Green No. 183-Y-546 (munsell 7.5GY2.95/2.1) or City of Vernon -approved equivalent. The.primary and finishing coats shall have a combined minimum dry -film thickness of three mils. Manufacturer shall furnish 1/4 pint of touch up paint for each transformer. 6.2 Underside Protection The underside of each transformer shall be coated with an asphaltic material or with City of Vernon -approved paint system. 7.0 HIGH VOLTAGE SWITCHES 7.1 Loadbreak Switches Each transformer shall have a three-phase, self- contained, oil immersed, high voltage, loadbreak gang - operated sectionalizing switch. The switches shall be inside the transformer tank and be so located that current interruption occurs under oil. The loadbreak switches shall provide circuit connections as shown on Exhibits A, B, C and D. Operation of the switch shall be clockwise to close. 7.2 Handles The operating handle shall be located in the high voltage compartment and be suitable for hot stick operation. The position of the switch, whether open or closed, shall be clearly indicated. The handle shall be located in such a manner as to be identifiable with the associated circuit -transformer or line B loop. Stencils or decals to indicate switch positions are not acceptable. SPECIFICATION NO. TR2-1992 Padmounted Dist. Transformers 5 City of Vemon 7.3 interlocks A. The switch shall have an interlock. which will prevent removal of fuses when the switch is in the closed position and also prevent the insertion of fuses when the switch is in the closed position. Line B or looping switch does not require any interlocking devices. B. Line B Switch - Provisions for mounting keyed interlock similar to that shown on Exhibit E shall be provided on all looped transformers. 7.4 Ratings The switches shall have the following ratings when completely assembled and installed in the transformers. A. Voltage Rating: 17,000 volts. B. Loadbreak Capability: 200 rms amperes at 17,000 volts and 0.6 power factor. C. Short -time Current Rating: 10,000 rms symmetrical amperes for 15 cycles. D. Closing and Holding Current Rating: 10,000 rms symmetrical amperes for 15 cycles- E. There shall be no arcing time after the switch blades have traveled from the closed position to the fully opened position. 8.0 OVERCURRENT PROTECTION 8.1 High Voltage Protection A. Transformers shall be protected against overcurrent by means of City of Vernon -approved externally replaceable fuses in the primary circuit. The fuses shall be suitable for hot stick operation and shall have a minimum of 20,000 rms symmetrical ampere interrupting rating. The fuses shall have City of Vernon -approved safety devices which prevent insertion directly into a fault. SPECIFICATION NO. TR2-1"2 Padmounted Dist. Transformers 6 City of Vernon B. The following table lists the appropriate fuse sizes: TABLE I Transformer Ratings Volts kVA High Voltage Voltage Ratings kV Fuses"' current Ratinas AMR 16,340 75 15.5 12 150 15.5 18 225 15.5 25 300 15.5 25 500 15.5 40 750 15.5 3014 1000 15.5 40c) 7,200 75 15.5 18 150 15.5 25 225 15.5 30 300 15.5 40 500 15.5 40") 11) Cooper (Type ELX) 0 Two parallel fuses per phase. 8.2 Low Voltage Protection Low voltage overcurrent protection is not required. 9.0 BUSHINGS, BUSHING WELLS AND PARKING STANDS 9.1 Low Voltage Bushings A. Transformers shall have bushings which conform to ANSI Standard C57.12.26. on "Wye" connected transformers, the neutral shall be connected to,a fully insulated bushing. An additional tank ground pad with removable neutral bushing ground strap shall be provided and suitably sized for the short circuit current rating of the transformer. SPECIFICATION NO. TR2-1992 Padmounted Dist. Transformen 7 City of Vemon B. External spade terminals shall have a heavy tin coating process. If the terminal extension is not an integral part of the bushing, it shall be securely pinned to the stud. Bolted -on extensions are not acceptable. C. External spade terminals with six holes d more shall be furnished with additional supportstraps, designed by the manufacturers, at the end farthest from the tank wall without interfering with the use of any of the holes. Refer to the table below for the number of terminal holes. TABLE 2 kVA Ratings LOW -Voltage Ratings (Volts) Number of 9/16 Holes 75-500 750-1500 2000 48OY/277 48OY/277 48OY/277 4 6 8 2500 48OY/277 10 75-225 2O8Y/12O 4 300-500 2O8Y/12O 6 750 2O8Y/12O 8 1000 2O8Y/120 10 9.2 High Voltage Bushing Wells A. Two circuit transformers shall be provided with six City of Vernon -approved, 15 kV high voltage bushing wells rated 95 kV BIL, and marked and located as shown on Exhibit A. B. One circuit transformers shall be provided with three City of Vernon -approved, 15 kV high voltage bushing wells rated 95 kV BIL, and marked and located as shown on Exhibit B. SPECIFICATION NO. TR2-I992 Padmounted Dist. Transformers 8 City of Vomon 9.3 Parking Stands A. Transformers shall be equipped with non -load break parking stands, ESNA No.. 151-PS or City of Vernon approved equivalent. They shall be located as shown Exhibits A, B and C in accordance with ANSI Standard C57.12.26. Parking stands shall be unpainted. 10.0 IDENTIFICATION A. All bushings shall be identified by yellow paint stencils, a minimum of one inch high, on the tank wall adjacent to the bushings. Line A and B of two circuit transformers shall also be identified. See Exhibits A, B and C. B. A removable identification tag or sticker which shall be legible at time of receipt shall be attached to the exterior of the terminal compartment. The tag or sticker shall indicate the name of the manufacturer, serial number, kVA and voltage ratings. C. In addition to the nameplate information called for in ANSI C57.12.00, the nameplate shall identify each winding as to whether it is made of copper or aluminum. 11.0 PRESSURE RELIEF DEVICES The following pressure relief devices are approved: A. Circle Seal Model No. P60-383 B. Qualitrol Model No. 202-32-01 C. Tomco Model No. 1712K-1, -5, or -6, or Model No. 175OK-5 12.0 ADDITIONAL REQUIREMENTS 12.1 Barriers A barrier shall separate the high voltage section from the low voltage section in the terminal compartment. See Exhibits A, B and C. Barrier shall be of sufficient strength to prevent deformation which my reduce the required clearances to various components. SPECIFICATION NO. TR2-IM Padmounted Dist. Transformen 9 City of Vernon 12.2 Conduit Entrance A 2-1/2 inch conduit entrance hole, with a cover which is removable only from the inside, shall be provided in the center of the low voltage sill, in accordance with Exhibits A, B and C. 12.3 Terminal Arrangements Terminal arrangements shall be in accordance with Exhibits A, B and C. 12.4 Access to Terminal and Switching Compartments A. Transformers shall be provided with -hinged doors for access to the terminal and switching compartments. Access to the high voltage portion of the terminal and switching compartment shall be possible only after access has been gained to the low voltage section. B. The low voltage compartment door shall be further secured by means of a captive and recessed 1/2 inch pentahead bolt. A blind bolt hole shall be provided. Bolts shall be corrosion resistant and the design shall minimize the possibility of a misalignment and cross -threading. Design of the bolting, padlocking and three-point latching provisions shall be coordinated such that, only after the padlock and bolt have been removed, shall it be possible to open the low voltage compartment door. 13.0 TESTS 13.1 General Transformer tests shall be performed as specified in ANSI Standard C57.12.00. 14. DESIGN LIFE The Apparatus shall be designed to have a minimum life expectancy of 30 years. 15. OPERATING PERFORMANCE The Apparatus shall perform in accordance with the conditions set forth in this Specification. SPECIFICATION NO. TR2-1992 PAdmounlcd DISC. TTansformors City of Vemon 10 y n • r f i4 O► O 0 O O w O O O O O M ► > M M M 0 M O O O In 0 LO ►O ►O N ► In Ln -ri to O In O 4J N ri N r1 ► N w N N O N O N 0 a a s ►O ► ►O O O O O to O to N 0 0 in rq x Ln r to r Ln W r-i ri O a ► ►O ►0 0 0 ►0 0 .0 O► O 1n o 1n o Ln 1n o 1n Ln O Ln o W r 1n r Ln r•1 r 1n r r Ln r N O ^ HH M M M M N1 M M v x N r N r N N ri N ra r N r N ON w o� ri � � \ \ as >4 >4 >4 o q w '� p o 00o coo 0 000 0 W > 0 W EH N W a�4N Ea E-+ E-1 Wco CO 0 O 0 o COE� r- 10' rl Nv 0 O co d' 0 co Tr O co -cr to D •ri ► ► w In ► ► w to %D 1n co °d° M co M co M tG M co z \\. \\ \\ r�o r�o r%o r% O p, 00 00 00 \\ \\ 00 \`� 00 \\ 00 H 4J Rf 0 .-i N01 O r1 N01 O °-1 N01 00 t0N SON WN %DN H a 1n o 1n O 1n o 1n o • z w a r♦ ,-e r Ln 1-4 r in ra r-I r Ln rl .-1 r r r r r r r r W z N tp w 0 x A � Iq O O O O tw •ri d0' M %;r M M N N N ► N ► HO toto ► �o r r r r 44 a ra r� ra EH N H s~ U �4 a> Ln L L Ln L, L 01 'n M E-+ HCA ,� 01 0► 0\ ON (A N V 0)4J W W O H a) x 4.0 W O W O z >4 z to r-I P > z >4 O [T4 > U H M -r. 4J O a •tP P O > P 4-) W W ° ® H 'z a*i N M d' In �O r W E-e O z 70' MAX. RADIATORS MAY EXTEND BEYOND THE IDIMENSIONS SHOWN TRANSFORMER HV I LV AREA I AREP PLAN SEE NOTE 2- /NAMEPLATE -� r Q 1 r L _ J LTRANS. SW. O O LINE B SW. XX x 1 3 O O N OU OU XO X2 Z Z HA HI Ou OU H2 H2 A B OU OU H3H3 A B 38' MIN. 22' MIN. I ELEVATION SCHEMATIC DIAGRAM I - Hi H A H A H B HB HI 0 1 XX2 X A 3 2-1/2' CONDUIT '- HOLE (SEE NOTE 3) NOTES, 1. ALL DIMENSIONS AND CLEARANCES SHALL CONFORM WITH ANSI C57.12,26. 2. CURRENT LIMITING FUSES INTERLOCKED WITH TRANSFORMER SWITCH. 3. 2-1/2' CONDUIT HOLE SHALL BE LOCATED IN THE CENTER (BOTH HORIZONTALLY AND VERTICALLY) OF THE LOW VOLTAGE CABINET SILL. 0 NO i REVISION WATM SPECIr IL;A i ILIN i KC WO -CIRCUIT PADMOUNTI TRANSFORMERS /07/92 cic 75 THROUGH 500 KVA DATE APPV'D CHK BY I EXHIBIT 'A' 1 70' MAX. RADIATORS MAY ^� EXTEND BEYOND THE DIMENSIONS SHOWN TRANSFORMER HV I LV AREA I AREA PLAN SEE NOTE 2 EXTERNALLY REPLACEABLE CL FUSES FI O O O I �- -.►' L — — .1 uo uo uo TRANS. SW H1 H2 H3 0 0 X1 X3 a' 0 0 n XO X2 a. 1 40-1/2' MIN. 22' MIN. ELEVATION SCHEMATIC DIAGRAM NAMEPLATE H1 142 H3 X0 X1 X2 X3 2-1/2' CONDUIT HOLE (SEE NOTE 3) NOTES, 1. ALL DIMENSIONS AND CLEARANCES SHALL CONFORM WITH ANSI C57.12,26. 2. CURRENT LIMITING FUSES INTERLOCKED WITH TRANSFORMER SWITCH. 3. 2-1/2' CONDUIT HOLE SHALL BE LOCATED IN THE CENTER (BOTH HORIZONTALLY AND VERTICALLY) OF THE LOW VOLTAGE CABINET SILL. 0 -- 12/07/92 L. /f,(Al I 1-,n NO REVISION DATE APPV'D CHK BY LOCATIDM SPEC) - 1L.A { lUN I KC DNE-CIRCUIT PADM®UNTEI TRANSFORMERS 75 THROUGH 500 KVA EXHIBIT 'B' ONE —CIRCUIT PADMOUNTEh TRANSFORMER 750 THROUGH 2500 KVA B RADIATORS MAY EXTEND BEYOND THE DIMENSIONS SHOWN TRANSFORMER C HV LV -- AREA AREA D PLAN EXTERNALLY REPLACEABLE CL FUSES r0 O O� r L _ —"J TRANS. SW UO UO UO H1 H2 H3 O ON Xi X3 A O O XX O 2 E o. ELEVATION NAMEPLATE DIM. 750, 1500 1000 & KVA 2000 2500 AND KVA A 90' MAX. 102' MAX. B 80' MAX. 85' MAX. C 68' MAX. 90' MAX. D 26' MIN. 26' MIN. E 42' MIN. 42' MIN. SECONDARY BUSHING LOCATIONS TO CONFORM WITH ANSI STANDARD C57.12.22 - FIG. 3 2-1/2' CONDUIT .f— HOLE (SEE NOTE 3) 6' . �6' Ze-iff WOM SIDE NOTES, 1. ALL DIMENSIONS AND CLEARANCES SHALL CONFORM WITH ANSI C57.12,26. 2, CURRENT LIMITING FUSES INTERLOCKED WITH TRANSFORMER SWITCH. 3. 2-1/2' CONDUIT HOLE SHALL BE LOCATED IN THE CENTER (BOTH HORIZONTALLY AND VERTICALLY) OF THE LOW VOLTAGE CABINET SILL. V LKNUV L. Wi i a e- u w Ln wl-. LWATMOO SPECIFICATION TR2 ONE -CIRCUIT PADMOUNTED TRANSFORMERS 0 12/07/92 �, �,� cjc 750 THROUGH 2500 KVA NO REVISION DATE APPV'D CHK I BY EXHIBIT "Cl 71 I ONE CIRCUIT (RADIAL) LINE A TWO CIRCUIT (LOOPED) LINE A--o�---- LINE B VERNON HT POWER PT LwA m * SPECTFICATInN ADDITIONAL CIRCUIT CONNECTIONS 0 12/07/92 ( CJC NO REVISION DATE APPV'D CHK BY EXHIBIT 'D* c nioum re 142 Pao# WA •� SCALEi 1' = 3/4' DC\/TCTnm L-3/lr TmVm 12/07/92 �(PE APPV'D CHK_ SPEGIF U f: r luiv I — TYPICAL. KEYED INTERLOCK FOR LOOPED TRANSFORMER LINE 'B' SWITCHES EXHIBIT 'E' SUPPORTING DOCUMENTS r CITY COUNCIL LEONIS C. MALBURG Mayor THOMAS A. YBARRA Mayor Pro -Tern WM. 'BILL" DAVIS Councilman H. "LARRY" GONZALES Councilman W. MICHAEL MCCORMICK Councilman BRUCE V. MALKENHORST City Administrator / City Clerk FAX (323) 581-7924 Finance Committee City of Vernon EDUARDO OLIVO City Attorney FAX: (562) 927-8722 KEVIN WILSON Director of Community Services & Water FAX: (323) 588-2761 KENNETH J. DeDARIO Director of Municipal Utilities FAX: (323) 583-1983 DAVE TELFORD Fire Chief FAX: (323) 581-1385 CITY HALL BRUCE W. OLSON 4305 SANTA FE AVENUE, VERNON, CALIFORNIA 90058 Pofice Chief TELEPHONE (323) 583-8811 FAX: (323) 5 5236 August 3, 2000 U" mob\ Honorable Members: 3 The Utilities Department is requesting to purchase Overhead Distribution Transformers and` Padmount Transformers to replenish their stock for electrical sery ce construction. z The Utilities Department was unable to provide an approximate cost for the requested transformers at this time. Funds to purchase these items were included in the budget, and it is hereby recommended that authorization be given to the Purchasing Section to seek formal bids for the purchase of Overhead Distribution Transformers and >-f55 Padmount TransformersX.O Very truly yours, Bruce V. Malkenhorst Director of Finance BVM:rcm 1 181:382IR lu TO: BRUCE V. MALKENHORST, CITY ADMINISTRATOR FROM: DEBBY NICKENS, PURCHASING DATE: AUGUST 2, 2000 Attached for your approval are requisition no(s) 04810 & 04813. The Utilities Department is requesting to purchase a total of (28) Overhead Transformers and (36) Padmount Transformers. The Department was unable to provide an approximate cost for the requested transformers. The Purchasing Department is requesting authorization to seek formal bids for the requested transformers.