Resolution No. 82961 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 RESOLUTION NO. 8296 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF VERNON APPROVING AND AUTHORIZING NOTICE INVITING SEALED PROPOSALS OR BIDS FOR THE PURCHASE OF A SF6 GAS VAULT SWITCH FOR THE LIGHT & POWER DEPARTMENT WHEREAS, the Light & Power Department is in need of a Sulfur Hexafluoride (SF6) gas vault switch (the "SF6 Switch") to be used as a spare at the Farmer John facility; and WHEREAS, on October 14, 2003, the Finance Committee considered the recommendation of Bruce V. Malkenhorst, Director of Finance, dated October 2, 2003, that authority be granted for the Purchasing Agent, or his designee, to seek formal bids for the purchase of the SF6 Switch; and WHEREAS, Specification No. GSI-2003 (the "Specification") has been prepared for the purchase of the SF6 Switch; and WHEREAS, the City Council of the City of Vernon has determined that it is in the best interests of the City of Vernon that bids or proposals be solicited in accordance with applicable State law and the Vernon City Code. NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF VERNON AS FOLLOWS: SECTION l: The City Council of the City of Vernon hereby finds and determines that the recitals contained hereinabove are true and correct. SECTION 2: The Specification, a copy of which is attached hereto as Exhibit "A" and made a part hereof, is hereby approved by the City Council of the City of Vernon. SECTION 3: The City Clerk of the City of Vernon, or his 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 designee, is hereby directed to give notice, in writing, inviting sealed proposals or bids for the purchase of the SF6 Switch in accordance with the Specification, and in accordance with this resolution. SECTION 4: There being no newspaper of general circulation printed, published or circulated in the City of Vernon, the City Clerk is hereby directed to post said notice, or cause the same to be posted, in three of the most public places in the City of Vernon, to wit: the northwest corner of 38th Street and Santa Fe Avenue, the northeast corner of Leonis Boulevard and Pacific Boulevard, and on the bulletin board in the lobby of the City Hall of the City of Vernon, located at 4305 Santa Fe Avenue, in said City. SECTION 5: The City Clerk of the City of Vernon is hereby directed to post said notice forthwith and the first posting of said notice shall be at least ten (10) days before the opening of the bids for the proposed contract. Said notice shall provide that sealed proposals or bids will be received by the City of Vernon at the office of the City Clerk, or his designee, at the City Hall, 4305 Santa Fe Avenue, Vernon, CA 90058-0805. - 2 - 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 SECTION 6: The City Clerk of the City of Vernon shall certify to the passage of this resolution, and thereupon and thereafter the same shall be in full force and effect. APPROVED AND ADOPTED this 15th day of October, 2003. ATTEST: BRUCE V. MALKENHORST, City Clerk C EONIS C. MALB RG, Ma or t - 3 - 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 STATE OF CALIFORNIA ) ) ss COUNTY OF LOS ANGELES ) I, BRUCE V. MALKENHORST, City Clerk of the City of Vernon, do hereby certify that the foregoing Resolution, being Resolution No. 8296, was duly adopted by the City Council of the City of Vernon at a regular meeting of the City Council duly held on Wednesday, October 15, 2003, and thereafter was duly signed by the Mayor of the City of Vernon. (SEAL) Zf===v BRUCE V. MALKENHORST, City Clerk - 4 - EXHIBIT 0 CITY OF VERNON LIGHT AND POWER Specification No. GS1-2003 1.0 SCOPE This specification outlines the requirements for a three phase, group operated, 60 Hz Resettable Fault Interrupter (RFI) switch utilizing Sulfur Hexafluoride (SF6) switches for load interruption and SF6 vacuum breaker switches for fault interruption tested to ANSI C37.71 or ANSI C37.60 featuring deadfront, compact, sealed, corrosion resistant construction for vault/subsurface installations. In comparing proposals or bids, consideration will not be confined to price only. The successful bidder will be one whose product is judged to best serve the interests of the City of Vernon when price, product, safety, quality and delivery are considered. The City of Vernon reserves the right to reject any or all proposals or bids or any part thereof, and to waive any minor technicalities from the specifications. A contract will be awarded to the bidder submitting the lowest responsible bid meeting the requirements of this specification. A. General The RFI shall have two (2) switch positions and three (3) protective (fault interrupter) positions as shown in Attachment A, Five Position S176 Gas Switch Configuration. The RFI shall include welded flange 200Amp deepwell on the fault interrupter ways and 600 Amp apparatus bushings on the switched positions per ANSI/IEEE 386. (Bolted and gasketed bushings are not acceptable). Attachment A shows the one -line diagram indicating the circuit configuration, number of switched ways, and type of bushings required. The switched position shall be located on either end and the resettable protective positions shall be in the middle. The switch shall be sized to fit through a 4' x 5' foot vault opening. The RFI shall be furnished factory filled with an electrical grade of non -toxic, non- flammable SF6 gas, conforming to ASTM D-2472. A pressure gauge, that provides visual status of the insulating dielectric, shall be included. The completed unit shall be capable of withstanding internal failure without explosion or fire and shall be capable of being mounted in any position for best cable training and operation. B. Switch Construction The RFI shall use deadfront, compact, sealed construction. A corrosion -resistant stainless steel tank shall enclose the contact system, interconnecting bus, operating mechanisms, and bushings. The switch must be maintenance free, all welded construction, eliminating the use of gasketed seals. T.I.G. inert gas welding with stainless steel filler rod shall be used to eliminate pinhole leaks and corrosion. 3of10 CITY OF VERNON LIGHT AND POWER Specification No. GS1-2003 The operating shafts must be sealed by a flexible stainless steel bellows (O-ring seals are not acceptable). Unless otherwise specified, cable connections, and operating accessories shall be located so only single side access is required for operation and installation. Operating handles shall be capable of being removed and stored or permanently attached. Movement of the operating handles will actuate an internal spring mechanism causing the switch/interrupter contacts to open or close and latch into position in quick make quick break operation. The spring operator will use compression springs for long life and will provide positive position indication. The switch contacts and interconnecting bus shall be plated copper with Belleville washers and locking fasteners to provide consistent pressure at bolted connections. The contacts shall be self -aligning, wiping type, incorporating tungsten copper arcing tips to prevent wear. The load interrupters use a puffer contact system for fast arc extinction. A special internal absorbent shall be used for improved performance and to prevent arc by-products. The RFI shall incorporate vacuum technology and be capable of interrupting fault currents up to the rated maximum. The interrupter shall use a flux shifter for tripping and be manually resettable with no consumable parts. (i.e. fuses). As a safety precaution, the interrupter will incorporate a trip -free mechanism to prevent the possibility of holding the interrupter closed under a faulted condition, with no reaction through the switch handle. The RFI mechanism shall be a true three-phase group operated device with no mechanical link between phases. An overcurrent condition on any phase will initiate the interrupter to trip open all three phases. The RFI interrupter shall also act as a three-phase, group operated loadbreak switch. A viewing window with indication of the interrupter contact position shall be provided. C. Trip Controls Overcurrent sensing shall be accomplished with an electronic trip control. The controls shall use current transformers external to the tank to sense the load currents. The current transformers will provide power to the electronic trip control. No external power shall be required. Per ANSI/IEEE C57.13, the current transformers shall be relay accurate class C200 with ratios of 600:0.5A for 600 Amp positions and 200:0.5A for 200 Amp protective positions. In order to provide immunity to system voltage disturbances (i.e. transients) the control will not be sensitive to system voltage conditions. The control shall be fully operable and meet the specified time -current curves when energized. Trip controls shall be either a vacuum fluorescent type display (VFD) selection or rotary dial. 4of10 CITY OF VERNON LIGHT AND POWER Specification No. GS1-2003 If providing a rotary selector switch, the selector switch control shall be used for 200 amp maximum loads. There shall be 10 fuse selections ranging from 30 to 200 amps. LED indication will be provided to show cause of the last trip simulating a S&C SM-20 "E" type fuse curve. An intermittently blinking LED shall be furnished to indicate ready status. The vacuum fluorescent display (VFD) shall be legible at —40°C without the need for a heater (Operating range —40°C to +65°C). The external current transformers on the switch will energize the display, when load current is flowing. In the event the switch is de -energized, a 9V-lithium battery shall be included to allow operation of the display and keypad for data gathering and parameter setting. The keypad shall be used to select the following parameters: TCC fuse curves, TCC fuse ratings, instantaneous trip, ground fault pick-up, ground fault delay and'protection mode. The VFD shall display the above data as well as the cause of trip. The electronic control shall have the ability to store up to 64 different TCC curves. Trip selection to be available in 12 positions from 10 to 450 amps. Instantaneous trip values shall be in multiples of 1.5 -12 times the current transformer's primary ratings in increments of 50% of the current transformer primary rating with values from 300A to 7200A. Ground fault trip settings shall range from 10-30% of the current transformer primary rating in increments of 5% of the current Transformer primary rating. Ground fault time delay shall be selectable in 10 settings from .05 to 1.0 seconds. A RS232 port shall be provided for communication with external devices. Status contacts for remote SCADA indication shall be provided. A manual trip push- button for electrically tripping the interrupter shall be provided, with provision for remote trip. A RS232 communication port shall be provided to read real time current and fault current. Status contacts for remote SCADA indication shall be provided. A manual trip push- button for electrically tripping the interrupter shall be provided, with provision for remote trip. 5of10 CITY OF VERNON LIGHT AND POWER Specification No. GS1-2003 D. Electrical Ratings And Standards: The switches and/or interrupter shall be designed, tested and built per applicable sections of ANSI C37.72, ANSI C37.71 and ANSI C37.60 Standards. The assembled switch assembly shall be rated as shown in Table 1, below. Table 1. RFI Ratings SWITCH RFI Maximum Design Voltage, KV 15.5 15.5 BIL Impulse Withstand, KV 95 95 Open Gap BIL Flashover Withstand, KV 200 95 One Minute AC Withstand, KV 35 35 Fifteen Minute DC Withstand, KV 66 53 Load Interrupting, Amps 600 600 Asymmetrical Momentary & Three Operation Fault Close, KA. _(Optional Ratings) 22.5 (32.40) 19.2 Symmetrical One Second Rating, KA. (Optional Ratings) 15 (20,25) 12 Continuous Current, A. 600 600 Overload Interrupting Capability, A 3,000 12,000 E. Standard Components The switch shall have the following standard components: 1 Removable operating handles with padlock provision in the open and closed position, capable of operation by hotstick or rope with direction of movement clearly indicated. 2. Stainless steel nameplates providing information including ratings, contact position indication, circuit configuration and phase identification. 3. Color coded pressure gauge for visual indication of normal operating range, enclosed in a protective housing to prevent damage. 4. Viewing window that provides fault interrupter position status. 5. Brass fill valve for field addition of SF6 protected and sealed with a removable cap. 6. Clamp type ground lugs, one for each set of bushings. 7. Stainless steel switch tank for maximum corrosion resistance. 8. 200 Amp deepwell on Protective Positions and 600 Amp apparatus welded bushings on switched positions with protective shipping caps. 9. Lifting and mounting provisions. 6of10 CITY OF VERNON LIGHT AND POWER Specification No. GSI-2003 F. Optional Features to be provided: The switch shall have the following optional features: 1. Visible break with contacts visible through viewing windows. 2. Visible break by external neon voltage indicator lights. 3. Operating handle orientation adapters. 4. Fault interrupter remote status. 5. Low pressure sensing device. 6. Operation counter. 7. Manual switching with remote cable operator. 8. Six wall mounted parking stands. G. Factory Production Tests 100% production testing shall include a mass spectrometer leak test, contact resistance, mechanical operation, AC one minute withstand and corona extinction tests as well as bulk SF6 moisture content. H. Cable Entrances Switches will include 200Amp deepwell and 600A apparatus welded bushings as required per ANSFIEEE 386. 2.0 DATA TO BE FURNISHED WITH BID A. Price, F.O.B. Soto Yard, 2800 Soto Street, Vernon California, 90058. B. Two sets of dimension, and outline drawings. C. Instruction manual for care and handling during storage. D. Delivery schedule E. Warranty conditions. 7of10 CITY OF VERNON LIGHT AND POWER Specification No. GS1-2003 3.0 CONTRACT The vendor shall be required to execute a purchase contract with City of Vernon, and shall be required to furnish proof of insurance pursuant to Attachment B, Insurance Schedule. The vendor shall provide a letter from.its insurance company that certifies the amounts of the insurance policy. The letter from the insurance company will be in substantially the same form as the SAMPLE INSURANCE FORM LETTER, which is also included in Attachment B. 4.0 SHIPMENT A. Supplier shall notify City 48 hours prior to delivery. All delivery shall be Monday - Friday, 7:30 AM to 3:00 PM. B. 30 days prior to shipment, supplier shall furnish certified Test reports of the switch. C. 30 days prior to shipment, supplier shall furnish three (3) sets of Operations/Instruction Manuals. 5.0 WARRANTY Supplier shall provide warranty for a minimum of twenty-four (24) months after delivery. 8of10 CITY OF VERNON LIGHT AN6POWER ' Specification No. GS1-2003 ATTACHMENT B INSURANCE SCHEDULE (Vendor) The Contractor shall provide proof of insurance, including a standard certificate of insurance, in at least the following amounts and coverage (combined single limit permitted): I. Coverage and Limits Hazards Automobile Liability Owned Automobiles Hired Automobiles Non -Owned Automobiles Workers' Compensation Employers' Liability II. General Liabilit Bodily Injury Each Person Each Accident $500,000 $1,000,000 $500,000 $1,000,000 $500,000 $1,000,000 $ Statutory $1,000,000 per employer Property Damage Each Accident $500,000 $500,000 $500,000 Premises Operations $1,000,000 $2,000,000 $1,000,000 Elevators (if applicable) $1,000,000 $2,000,000 $1,000,000 Independent Contractors $1,000,000 $2,000,000 $1,000,000 Products —Completed $1,000,000 $2,000,000 $1,000,000 Operations Contractual Liability $1,000,000 $2,000,000 $1,000,000 Umbrella Liability $2,000,000 $2,000,000 $2,000,000 1. The general liability policy shall contain the following special endorsements which shall be noted on or attached to the standard certificate of insurance: a) An endorsement naming the City of Vernon, its officers, and employees as additional insureds under the policy. b) An endorsement providing the City of Vernon thirty (30) days notice of cancellation or material reduction of coverage. c) An endorsement providing coverage for all operations under this Contract. d) Such other endorsement as may be required by addendum hereto. 2. In addition to the standard certificate of insurance, proof of general and umbrella liability coverage shall be furnished in the form checked below. Only certification of the following proofs will be accepted: X For each policy, a notarized letter from the underwriter or carrier certifying that the coverage and statements in the standard certificate of insurance (attached thereto) are true and correct and that the signator is an officer authorized to so certify. A copy of each policy certified by an officer of the underwriter or carrier and notarized. 9 of 10 CITY OF VERNON LIGHT AND POWER Specification No. GS1-2003 SAMPLE INSURANCE FORM LETTER (To be issued on insurance carrier letterhead. This letter must be notarized). Date: City of Vernon ("City") 4305 Santa Fe Avenue Vernon, CA 90058 Attn: Risk Management Department Re: Insurance for City of Vernon (description ofpermit or contract) Policy Number(s) Named Insured: City Clerk: I hereby certify that the certificate of insurance attached hereto and made a part hereof by reference truly and accurately represents the above -cited insurance policies and the insurance coverage of each for the named insured issued by (insurance carrier). The City of Vernon, its officers, and employees are included in said policies as additional insureds and the City of Vernon will be provided with thirty (30) days written notice of cancellation or material reduction of coverage. I certify that I am an officer of the insurance carrier named herein and that I am authorized to sign this certificate on behalf of said insurance carrier. Signature Title 03/03 10 of 10 • ` s 5 4 3 2 1 LINE 1 1 1 LINE 2 P❑SITI❑N BUSHING RATING (AMPS) 1 600 2 200 3 200 4 200 5 600 N❑TES: 1, SWITCHED P❑SITI❑NS SHALL BE ❑N EITHER SIDE ❑F THE PROTECTIVE P❑SITI❑NS, 2. PR❑TECTIVED P❑SITI❑NS ARE AS SH❑WN, VERN❑N LIGHT AND P❑WER SPECIFICATI❑N GS1-2003 FIVE P❑SITI❑N SF6 GAS SWITCH 1 9/29/03 JL C❑NFIGURATI❑N N❑ REVISI❑N DATE APPV'D CHK BY ATTACHMENT A SUPPORTING DOCUMENTS 8z°' Q AFFIDAVIT OF POSTING STATE OF CALIFORNIA ) COUNTY OF LOS ANGELES) ss CITY OF VERNON ) I, �--- , of the City of Vernon do hereby certify that I did, on the 4th of November 2003, post three (3) copies of: Notice Inviting Sealed Proposals (Bids) for Bid 41431 (1) Sulfur Hexaflouride (SF6) Gas Vault Switch for the Light and Power Department One in each of the following places, to wit: on the bulletin board in the lobby of the City Hall of the City of Vernon located at 4305 Santa Fe Avenue; at the northwest corner of 38th Street and Santa Fe Avenue; the northeast corner of Leonis Blvd. and Pacific Blvd., all in said City, there being no newspaper of general circulation printed and published in the City of Vernon. Date: r\,I 6�o-,3 State of California ) )ss County of Los Angeles) On ,before Personally appeared S'/1(� 01/N �p�nulSav� Personally known to me to be the person(o)'whose name(' is/are subscribed to the within instrument and acknowledged to me that die/she/t-4e-y executed the same in his/her/t-he-i-r authorized capacity, and that by -ems/her/-t-he4-r signature ('W� on the instrument the person(, or the entity upon behalf of which the person( acted, executed the instrument. WITNESS my hand and official seal ti to t. tos A ci..5 County IVhl Cc +n n. C�as"23, 2M4 AFFIDAVIT OF POSTING STATE OF CALIFORNIA ) COUNTY OF LOS ANGELES) ss CITY OF VERNON ) I , -<* tee- '-,,;,,.. -L-- c'h Ste" _ , of the City of Vernon do hereby certify that I did, on the 16th of October 2003, post three (3) copies of: Notice Inviting Sealed Proposals (Bids) for Bid 41430 (2) TVI 3-Line Hazardous Materials Decontamination Shelter Systems for the Fire Department One in each of the following places, to wit: on the bulletin board in the lobby of the City Hall of the City of Vernon located at 4305 Santa Fe Avenue; at the northwest corner of 38th Street and Santa Fe Avenue; the northeast corner of Leonis Blvd. and Pacific Blvd., all in said City, there being no newspaper of general circulation printed and published in the City of Vernon. Date: State of California ) ) ss County of Los Angeles) Onm3before me, Ct1&*1,1 L) Personally appeared Personally known to me to be the person X whose name( is/ -awe subscribed to the within instrument and acknowledged to me that -he/she/t iey executed the same in hzi-s/her/the-i-r authorized capacity, and that by es/her/-their signature,K on the instrument the person X, or the entity upon behalf of which the person �K) acted, executed the instrument. WITNESS my hand and official seal M I VALE L+Ef_A Ccmmu 7cn i 1261903 Z < < Notary Pubic - CaMomia > i 3, Los An,e`vs County My Comm. %ice May 23, 2004 AFFIDAVIT OF POSTING STATE OF CALIFORNIA ) COUNTY OF LOS ANGELES) ss CITY OF VERNON ) I , L , :Tch � ,ram. , of the City of Vernon do hereby certify that I did, on the 15th of October 2003, post three (3) copies of: Notice Inviting Sealed Proposals (Bids) for Bid #1429 (19) Padmount Transformers for the Light & Power Department One in each of the following places, to wit: on the bulletin board in the lobby of the City Hall of the City of Vernon located at 4305 Santa Fe Avenue; at the northwest corner of 38th Street and Santa Fe Avenue; the northeast corner of Leonis Blvd. and Pacific Blvd., all in said City, there being no newspaper of general circulation printed and published in the City of Vernon. �a Date: kl� k.1(13 State of California ) ) ss County of Los Angeles) On -, \I-e v►11� �`� :%Zbo3 before me, YYjp 4} Na� 6. Personally appeared Personally known to me to be the person N whose nameCoi is/-a-� subscribed to the within instrument and acknowledged to me that 4ie/she/t4ey executed the same in -h4-s/her/t-h1e-i7r authorized capacity, and that by 4i-s/her/their signature XJ on the instrument the person X), or the entity upon behalf of which the person X acted, executed the instrument. WITNESS my hand and official seal S VALENZUELA r omrn�ss+cn 1261OG3 L NotGry ub� ;c - Ca + ifomin > "7 Los Angeles County Cc-nm.Fxf-kesMay 23,2004 BID RESULTS BID: OPENING DATE: DESCRIPTION: VENDORS 1. CANADIAN POWER (c/o Banes Associates) 2. G & W VAULT SF6 SWITCHES (c/o Banes Associates) 3. ERMCO TRANSFORMERS (c/o McAvoy & Markham) 4. ALSTOM T & D, Inc., (c/o McAvoy & Markham) 5. COOPER POWER SYSTEMS (c/o Utility Products) *Sales tax not included (� L) 0 #1431 V/ NOVEMBER 18, 2003 (1) SULFUR HEXAFLOURIDE (SF6) GAS VAULT SWITCH BID TOTAL* $30,990.00 $31,887.00 No bid No bid No bid