Resolution No. 83191 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 RESOLUTION NO. 8319 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF VERNON ACCEPTING THE BIDS OF ABB, INC. AND PAUWELS TRANSFORMERS, INC. C/O PACIFIC UTILITIES SUPPLY COMPANY ON BID NO. 1429 FOR THE PURCHASE OF PADMOUNTED DISTRIBUTION TRANSFORMERS FOR THE LIGHT AND POWER DEPARTMENT AND APPROVING AND AUTHORIZING THE EXECUTION OF EQUIPMENT PURCHASE CONTRACTS AND THE ISSUANCE OF PURCHASE ORDERS RESPECTING SAID BIDS WHEREAS, the Light & Power Department is in need of 19 IPadmounted Transformers for use on the City of Vernon's underground (distribution systems; and WHEREAS, pursuant to Resolution No. 8287 adopted by the City lCouncil of the City of Vernon on October 1, 2003, the City Clerk was directed to give notice inviting sealed proposals or bids for the purchase of the 19 Padmounted Transformers in accordance with a bid specification provided by the Light & Power Department; and WHEREAS, based upon the bid specification, the Purchasing Department prepared Bid No. 1429 dated October 14, 2003, and sealed bids were opened on November 4, 2003; and WHEREAS, the Light & Power Department reviewed the bids received and approved the bids based upon their analysis of the total ownership cost of each bid with a 5% window evaluation in accordance with the bid specification; and WHEREAS, by letter dated November 13, 2003, Bruce V. IMalkenhorst, City Administrator/City Clerk, recommended that Bid No. 1429 be awarded to ABB, Inc. and Pauwels Transformers, Inc. c/o Pacific Utilities Supply Company, based on a total ownership cost analysis. NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 CITY OF VERNON AS FOLLOWS: SECTION 1: The City Council of the City of Vernon hereby finds and determines that the recitals contained hereinabove are true and correct. SECTION 2: The City Council of the City of Vernon hereby awards Bid No. 1429 to ABB, Inc. and Pauwels Transformers, Inc. c/o Pacific Utilities Supply Company and accepts and approves the Equipment Purchase Contracts, copies of which are attached hereto as Exhibits "A"' and "B," respectively, and made a part hereof. SECTION 3: The City Council of the City of Vernon hereby authorizes the Mayor and the City Clerk to execute the Equipment Purchase Contracts on behalf of the City and authorizes the issuance of a purchase order for the purchase of the Padmounted Transformers pursuant to Bid No. 1429. SECTION 4: The City Council of the City of Vernon hereby directs the City Clerk, or his designee, to send one fully executed Contract with ABB. Inc. to: ABB, Inc. Attn: Jeff Vivian 2945 Harding Street, Suite 207 Carlsbad, CA 92008 SECTION 5: The City Council of the City of Vernon hereby directs the City Clerk, or his designee, to send one fully executed Contract with Pauwels Transformers, Inc. to: Pauwels Transformers, Inc. Attn: Diana Kallmbah, Account Specialist One Pauwels Drive Washington, MO 63090 SECTION 6: All other bids in connection with Bid No. 1429 are rejected, subject to execution of the aforesaid contract documents - 2 - K 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 from ABB, Inc. and Pauwels Transformers, Inc., accompanied by all required certificates. SECTION 7: The City Clerk of the City of Vernon shall certify to the passage of this resolution, and thereupon and thereafter the same shall be in full force and effect. APPROVED AND ADOPTED this 19th day of November, 2003. ATTEST: BRUCE V. MALKENHORST, City Clerk EONIS C. MALB G, Mafor - 3 - 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 STATE OF CALIFORNIA ) ) ss COUNTY OF LOS ANGELES ) I, BRUCE V. MALKENHORST, City Clerk of the City of Vernon, do hereby certify that the foregoing Resolution, being Resolution No. 8319, was duly adopted by the City Council of the City of Vernon at a regular meeting of the City Council duly held on Wednesday, November 19, 2003, and thereafter was duly signed by the Mayor of the City of Vernon. (SEAL) BRUCE V. MALKENHORST, City Clerk - 4 - EXHIBIT 1 EQUIPMENT PURCHASE CONTRACT 2 3 THIS AGREEMENT is made, entered into and executed in 4 duplicate originals, either copy of which may be considered and used as 5 the original hereof for all purposes, as of this day of November, 6 2003, in the City of Vernon, County of Los Angeles, California 7 BY AND BETWEEN THE CITY OF VERNON (hereinafter referred to as 8 the "City") 4305 Santa Fe Avenue 9 Vernon, CA 90058 10 AND ABB, INC. (hereinafter referred to as 11 "ABB") 2945 Harding St., Suite 207 12 Carlsbad, CA 92008 13 RECITALS 14 WHEREAS, on October 14, 2003, the City requested proposals 15 or bids for nine (9) bid items totaling nineteen (19) Padmounted 16 Distribution Transformers (Bid No. 1429) needed by the City's Light & 17 Power Department; and 18 WHEREAS, the City is permitted to accept or reject any or 19 all quotations received on the bid items; and 20 WHEREAS, on or about November 4, 2003, the City received 21 various proposals for the sale of Padmounted Distribution Transformers 22 identified in Bid No. 1429, with each of the nine bid items quoted 23 separately; and 24 WHEREAS, on November 3, 2003, ABB submitted a bid; and 25 WHEREAS, on November 4, 2003, the City opened the bid 26 submitted by ABB, as well as other bids for the items identified in 27 Bid No. 1429; and 28 WHEREAS, the City desires to purchase the following bid 1 items from ABB: three (3) 500 KVA 7.2 277/480 Padmounted Transformers; 2 one (1) 150 KVA 16.34 120/208 Padmounted Transformer; three (3) 300 3 KVA 16.34 277/480 Padmounted Transformers; three (3) 1000 KVA 16.34 4 277/480 Padmounted Transformers; and, two (2) 2500 KVA 16.34 277/480 5 Padmounted Transformers per City of Vernon Specification No. TR2-2003, 6 for a total of twelve (12) Padmounted Transformers. 7 NOW, THEREFORE, THE PARTIES HERETO DO MUTUALLY AGREE AS SET 8 FORTH HEREIN: 9 1. Purchase. ABB agrees to sell and deliver to the City a 10 total of twelve (12) Padmounted Transformers referenced above pursuant 11 to City of Vernon Specification No. TR2-2003, as identified in ABB's 12 November 3, 2003 bid and which meet the specifications contained in 13 City of Vernon Bid No. 1429, dated October 14, 2003 (collectively 14 referred to as the "Bid Documents"). A copy of the Bid Documents are 15 attached hereto as Exhibit "A" and incorporated herein by reference. 16 2. Time of Performance. ABB's performance shall commence 17 upon the full execution of this Contract and shall be completed by ABB 18 within 10 weeks after receipt of order. 19 3. Price. The City agrees to purchase twelve (12) 20 Padmounted Transformers from ABB for the total sum of Ninety -Seven 21 Thousand Ninety -Nine Dollars and No Cents ($97,099.00). This price 22 includes freight and excludes sales tax. 23 4. Delivery. Consistent with the Bid Documents, ABB agrees 24 to deliver the twelve (12) Padmounted Transformers on a flatbed truck 25 for side unloading by forklift at ground level to the Soto Yard at 26 2800 Soto Avenue, Vernon, California. ABB shall notify the City 48- 27 hours prior to delivery to make arrangements for gates to be opened. 28 Delivery shall be scheduled for Monday through Thursday between the -2- 1 hours of 7 a.m. and 3 p.m. 2 5. Warranties. ABB warrants title to the Padmounted 3 Transformers purchased hereunder and any part thereof to be free of 4 any claim or any security interest, lien or encumbrance. ABB also 5 warrants that the Padmounted Transformers will be delivered new and 6 shall be free from defects. ABB shall provide, at a minimum, a one 7 (1) year labor and material warranty to begin upon acceptance of the 8 Padmounted Transformers by the City. All manufacturers' warranties, 9 any warranties typically provided by ABB and any other warranties made 10 applicable by law shall apply to the City's purchase of the Padmounted 11 Transformers. 12 6. Governing Law. The validity, interpretation and 13 performance of this Contract shall be controlled and construed under 14 the laws of the State of California. 15 7. Forum Selection. Any action brought relating to this 16 Contract shall be brought and held exclusively in a State Court in the 17 County of Los Angeles, California. 18 8. Notices. Notices to the parties, unless otherwise 19 requested in writing, shall be sent to: 20 City: THE CITY OF VERNON 21 ATTN: DOLORES FONSECA PURCHASING ASSISTANT 22 4305 SANTA FE AVENUE VERNON, CA 90058-0805 23 ABB: ABB, INC. 24 ATTN: JEFF VIVIAN 2945 HARDING STREET, SUITE 207 25 CARLSBAD, CA 92008 26 9. Risk of Loss. 27 Title and risk of loss or damage shall pass to the City and 28 delivery shall be deemed to be complete upon delivery FOB jobsite or -3- SENT BY: ABB INC.; 760 720 2861; NOV-18-03 11:26AM; PAGE 919 1 upon moving into storage at the City's request, whichever occurs 2 f irst . 10. Attorneys' Fees. In the event that it becomes necessary for either party to - this Agreement to enforce any of the provisions of this Agreement, the parties agree that a court of competent jurisdiction may determine and fix reasonable attorney's fees to be paid to the successful litigant. WITNESS WHEREOF, the parties have caused this Agreement to be executed by and through their authorized officers on the date, month and year first written above. ATTEST: BRUCE V. MALKENHORST, City Clerk APPROVED AS TO FORM: ERIC T. FRESCH, City Attorney By: CITY OF VERNON LEONIS C. MALBURG, Mayor ABB, INC. By: Title:. Y tkz W, i By : —. Title: -4 SENT BY: ABB INC.; 760 720 2861; NOV-17-03 3:20PM; PAGE 212 ABB INC. SECRETARY'S CERTIFICATE I, E. Barry Lyon, Assistant Secretary of AB13 Inc. (the "Company") hereby certifies that the following resolutions were duly adopted on November 14, 2003 by Unanimous Written Consent of the Directors of the Company, and have not been modified or rescinded to date; WHEREAS, the Company entered into negotiations to sell and deliver certain products and services to the City of Vernon, California, and WHEREAS, the Company and the City have determined to enter into written agreements to provide certain goods and services to the City. NOW THEREFORE, it is hereby RESOLVED, that the Company be and it is hereby authorized to enter into certain contracts and agreements from time to time for the sale of goods and services to the City of Vernon, California, and FURTHER RESOLVED, that the following employees be, and each is hereby, authorized to execute and deliver to the City of Vernon, California, such contracts and agreements for the sale, delivery and installation, as the case may be, of products and the provision of services in each case upon such terms and conditions as each such authorized employee shall agree, such agreement to be evidenced by the execution and delivery of each such contract and agreement: John Sullivan President, Power Technology Division USA Trent Spear Chief Financial Officer, Power Technology Division USA Jack Dwyer Vice President Sales and Marketing, Power Technology Division USA Azar Chowdry Vice President Western Region, Power Technology Division USA David Onuscheck Assistant General Counsel and Asst. Secretary, Power Technology Division USA IN WITNESS WHEREOF, the undersigned has signed this Certificate as of this 17th day of November, 2003. ABB Inc. Name: E. Ba yo Title: Assistant Secretary EXHIBIT AV REQUEST FOR QUOTATIONS NOT A PURCHASE ORDER DIRECT ALL INQUIRIES TO: CITY PURCHASING AGENT TELEPHONE (323) 583-8811 CITY OF VERNON, CALIFORNIA PURCHASING DEPARTMENT CITY HALL 4305 Santa Fe Ave, - Vernon, California 90058 TO: ABB, Inc., attn: Jeff Vivian 9945 Na Ste-_207 Carlsbad, CA 92008 M Please quote hereon the lowest net price you can furnish the articles or services specified below. Quote on each item separately. Bidder may qualify quotations as "all or none" by stating so on body of form. City reserves the right to accept or reject quotations received on any or all items. In order to maintain their name on City's Bidder File, Vendor should return this form whether a price is Quoted or not. QUANTITY DESCRIPTION NET UNIT PRICE TOTAL Padmount Transformers as per attached specifications No. TR2-2003, dated September 15, 2003 KVA PRIMARY VOLTAGE KV SECONDARY VOLTAGE 3 500 7.2 277/480 5g93 1-7P19 2 750 _ 7.2 277/480 pllo I1PIO 2- 1 150 16.34 120/208 41 ` -7 4, 1, 4 3 300 16.34 277/480 4-77 14,1-7 _ 1 500 16.34 277/480 5,9,ag 3 750 16.34 277/480 -7gg0 Z3G1-1 D 3 1000 16.34 277/480 6353LO z$,6013 2 2500 16.34 277/480 1lt1(Xt5 32,1'q r 1 3750 16.34 277/480 3,-7 2-0 Deliver on flatbed truck for side unloading by forklift at ground level, Please notify RMI-US at (323) 589-9498 (48) hours prior to delivery. If you have any questions, Mjj,� please contact Jose Lugo at (323) 583-8811, ext. 276.GI C� Sre-nu-- I✓;+� Df VemU-n Spec. Nt© 7PZ-2003 ------------PLEASE NOTE---------- Bid number must be indicated on the outside of the envelope; otherwise, bid will not be accepted. IF INSUFFICIENT SPACE PROVIDED ABOVE FOR PROPOSAL, ATTACH RIDER OR SUPPLEMENT. CASH DISCOUNTS QUOTED FOR PERIODS OF LESS THAN 30 DAYS WILL NOT BE CONSIDERED WHEN ORDER IS AWARDED. BIDS RECEIVED IN RESPONSE TO THIS REQUEST FOR QUOTATION WILL BE OPENED IN CITY PURCHASING AGENTS OFFICE ON THE 4th DAYOF NovPmhar 2o03._AT NOTE: Quote prices exclusive of Sales Tax and xcise T es. cc��77 ll A. Indicate Sales Tax in this space $..1.5.4.1.��. ,..... .(IF-6.. 9)..............B. Indicate Excise Tax in this space $ .................................. ........ ........... B. Above quotations subject to Cash Discount of ........... 0............... %, F.0.B.................. . C. To be delivered to CITY OF VERNON at.....,� .(�'l�....�� �Ve C14Ler:..).rrion................ q..�..'.?.!?.................................................. We (1) agree to furnish above in ...U..-.1.�..LN�G.K ......days from receipt oo/f��purchase (forder at prices specified. FOR...........1 `.. pT.. fi)�.............................. .................. ..................... / Firm Name DATE......l.../'. ....................... a ..... SIGN HERE....... ...... ...�- .......�1.,�1 �:.�!!/.�....................... MAIL TO PURC SIN DE T. 12M PM 0 W N O O W X m (O00�10)Ul� W N� M o ao oD oD Oo ao ao ao 0o r-. m m m m m m m m m 0 mmmmmmmmm -5mminrn ernrTn,rn m mmmmmmmmm .nmmmmm-nmm mmmmmmmmm xxxxxxxxxo _j -i -1 - --1 -1 --1 --1 -1 R 000000000m D D D D D D D D D Z D D D D D D D D O mmmmmmmmm zzzzzzzzz -1-1-1-i-1-1-A-1--1 g vmmmmmmmm z 00000000 ;Urrrrrrrrr 0 O-P-PA-N.A-A -N -N W O O O O O O O O O W W W W W W W W 0�00000000 z 0 r 0 Ncorn p NNO)(nNWNOOODD O cc)-� 0 O CO) r O D 0 41 -4 0) (71 OD OD r OD 01 (A) oh W w00 N O O D (Oil w (m)1 w w w m m (oil r O t, 0 0) o co 1")0 O O N O Ol -I Ul OD O ch (D O v O Ul W N =i EU"U0> m Q 0- W O6p n , C �Nww-�w�Nw Zzl< Z 0 4Ol0-IOI W •-4 n Tj zz (noov'oo(ncno 000000000D G nm Op C > m W D .fl < 0 rn9)9)9)9)9)9)-4v< w w w w wP w A N N O IG) D 'Oo O m D r U) m 0 0 z N N N N N N K) N N D 4-4-4-4 v-1J-4NJ -1 �v v O -I -! � N N N � r D O m C c�tflcflv9�� E�»F» w rn CO -4rn P n OD ( z -1 0 (n (O co -4 0 (0 0)0 OD (n -! 0)W O U1 /� \I m � y� P W N N 64) 61) 9 69 Z W N 00 W Ol -4. O) -4 4 0)10o m ,po(0 NOOOOD0ODol4NCCO C Z1 n m m 0 m z olrnOno P Arnrn -i W W AwpJ-4K) 01(On 'O ---------------------------------------------------------------------- QUESTION: 6.2: Why interlock a loadbreak fuse to an on/off switch? Bay-o-net fuses are not normally interlocked to a switch. ---------------------------------------------------------------------- Comments: 11.H: Gauge of steel in tank walls, cover, and bottom is 7ga. Gauge of steel in cooling fins is 16ga. Attachment D: Dimensions D and E equal or exceed minimums specified. ---------------------------------------------------------------------- Pls Quote: 3 Phase, 60 Hertz, 65 Deg C AWR, 30 Deg C Avg Ambient, Radial, MTR (Padmounted), Green 7GY/3.29/1.5Munsell Primary : 7200 Connection HV1 Position is Delta HV kV BIL 095 HV1 Taps 2AN2BN (+2,-2 @ 2.5%) Secondary 480Y/277 Engr. Spec: TR2-2003 Revision: X Rev Date: 091503 Accessories: 200 amp HV bushing wells Special high voltage bushing pattern LV bushings with 4-hole NEMA spade terminals 1W U Fused bayonet no isolation link Oil -immersed partial range current limiting fuse ANSI specific staggered low voltage pattern 2-position 200 amp LBOR transformer switch Fuse/switch interlock mechanism Spare expulsion fuses (set of 6) Dial type thermometer Liquid level gauge Drain valve and sampler Touch up paint (12 oz spray can) Mineral oil with inhibitor Provision for one (1) conduit entrance Special label(s) and/or decal(s) Additional nameplate Integral LV Spades ITEM QUANTITY KVA NET EACH SHIPMENT CUSTOMER CODE 1 9 500 5993 8-10 ---------------------------------------------------------------------- Pls Quote: 3 Phase, 60 Hertz, 65 Deg C AWR, 30 Deg C Avg Ambient, Radial, Small Power (Padmounted) , Green 7GY/3.29/1.5Munsell Primary : 7200 Connection HV1 Position is Delta HV kV BIL 095 HV1 Taps 2AN2BN (+2,-2 @ 2.5%) Secondary : 480Y/277 Engr. Spec: TR2-2003 Revision: X Rev Date: 091503 Accessories: 200 amp HV bushing wells Special high voltage bushing pattern LV bushings with 12-hole NEMA spade terminals with supports Fused bayonet no isolation link Oil -immersed partial range current limiting fuse ANSI specific staggered low voltage pattern 2-position 200 amp LBOR transformer switch Fuse/switch interlock mechanism Spare expulsion fuses (set of 6) Dial type thermometer Liquid level gauge Drain valve and sampler Touch up paint (12 oz spray can) Mineral oil with inhibitor 2411 deep cabinet Provision for one (1) conduit entrance Special label(s) and/or decal(s) Additional nameplate Integral LV Spade ITEM QUANTITY KVA NET EACH SHIPMENT CUSTOMER CODE 2 6 750 8016 8-10 ------------�---------------------------------------------------------- Pls Quote: 3:.Phase, 60 Hertz, 65 Deg C AWR, 30 Deg C Avg Ambient, Radial, MTR (Padmounted), Green 7GY/3.29/1.5Munsell Primary 16340 Connection HV1 Position is Delta HV kV BIL 095 HV1 Taps 2AN2BN (+2,-2 @ 2.5%) Secondary : 208Y/120 Engr. Spec: TR2-2003 Revision: X Rev Date: 091503 Accessories: 200 amp HV bushing wells Special high voltage bushing pattern LV bushings with 4-hole NEMA spade terminals Fused bayonet no isolation link Oil -immersed partial range current limiting fuse ANSI specific staggered low voltage pattern 2-position 200 amp LBOR transformer switch Fuse/switch interlock mechanism Spare expulsion fuses (set of 6) Dial type thermometer Liquid level gauge Drain valve and sampler Touch up paint (12 oz spray can) Mineral oil with inhibitor Provision for one (1) conduit entrance Special label(s) and/or decal(s) Additional nameplate Integral LV Spades ITEM QUANTITY KVA NET EACH SHIPMENT CUSTOMER CODE 3 3 150 4147 8-10 ---------------------------------------------------------------------- Pls Quote: 3 Phase, 60 Hertz, 65 Deg C AWR, 30 Deg C Avg Ambient, Radial, MTR (Padmounted), Green 7GY/3.29/1.5Munsell Primary : 16340 Connection HV1 Position is Delta HV kV BIL 095 HV1 Taps 2AN2BN (+2,-2 @ 2.5%) Secondary 480Y/277 Engr. Spec: TR2-2003 Revision: X Rev Date: 091503 Accessories: 200 amp HV bushing wells Special high voltage bushing pattern IV bushings with 4-hole NEMA spade terminals Fused bayonet no isolation link Oil -immersed partial range current limiting fuse ANSI specific staggered low voltage pattern 2-position 200 amp LBOR transformer switch Fuse/switch interlock mechanism Spare expulsion fuses (set of 6) Dial type thermometer Liquid level gauge Drain valve and sampler Touch up paint (12 oz spray can) Mineral oil with inhibitor Provision•, for one (1) conduit entrance Special label(s) and/or decal(s) Additional nameplate Integral LV Spades ITEM QUANTITY KVA NET EACH SHIPMENT CUSTOMER CODE 4 9 300 4725 8-10 ---------------------------------------------------------------------- Pls Quote: 3 Phase, 60 Hertz, 65 Deg C AWR, 30 Deg C Avg Ambient, Radial, MTR (Padmounted), Green 7GY/3.29/1.5Munsell Primary : 16340 Connection HV1 Position is Delta HV kV BIL 095 HV1 Taps 2AN2BN (+2,-2 @ 2.5%) Secondary 480Y/277 Engr. Spec: TR2-2003 Revision: X Rev Date: 091503 Accessories: 200 amp HV bushing wells Special high voltage bushing pattern IV bushings with 8-hole NEMA spade terminals IV spade supports Fused bayonet no isolation link Oil -immersed partial range current limiting fuse ANSI specific staggered low voltage pattern 2-position 200 amp LBOR transformer switch Fuse/switch interlock mechanism Spare expulsion fuses (set of 6) Dial type thermometer Liquid level gauge Drain valve and sampler Touch up paint (12 oz spray can) Mineral oil with inhibitor Provision for one (1) conduit entrance Special label(s) and/or decal(s) Additional nameplate Integral IV Spades ITEM QUANTITY KVA NET EACH SHIPMENT CUSTOMER CODE 5 3 500 5988 8-10 Pls Quote: 3 Phase, 60 Hertz, 65 Deg C AWR, 30 Deg C Avg Ambient, Radial, Small Power (Padmounted) , Green 7GY/3.29/1.5Munsell Primary : 16340 Connection HV1 Position is Delta HV kV BIL 095 HV1 Taps.: 2AN2BN (+2,-2 @ 2.5%) Secondary 480Y/277 Engr. Spec: TR2-2003 Revision: X Rev Date: 091503 Accessories: 200 amp HV bushing wells Special high voltage bushing pattern IV bushings with 12-hole NEMA spade terminals with supports Fused bayonet no isolation link Oil -immersed partial range current limiting fuse ANSI specific staggered low voltage pattern 2-position 200 amp LBOR transformer switch Fuse/switch interlock mechanism Spare expulsion fuses (set of 6) Dial,type thermometer Liquid level gauge Drain valve and sampler Touch up paint (12 oz spray can) Mineral oil with inhibitor 24" deep cabinet Provision for one (1) conduit entrance Special label(s) and/or decal(s) Additional nameplate Integral LV Spade ITEM QUANTITY KVA NET EACH SHIPMENT CUSTOMER CODE 6 9 750 7990 8-10 7 9 1000 9536 8-10 ---------------------------------------------------------------------- Pls Quote: 3 Phase, 60 Hertz, 65 Deg C AWR, 30 Deg C Avg Ambient, Radial, Small Power (Padmounted) , Green 7GY/3.29/1.5Munsell Primary : 16340 Connection HV1 Position is Delta HV kV BIL 0-95 HV1 Taps 2AN2BN (+2,-2 @ 2.5%) Secondary 480Y/277 Engr. Spec: TR2-2003 Revision: X Rev Date: 091503 Accessories: 200 amp HV bushing wells Special high voltage bushing pattern LV bushings with 16-hole NEMA spade terminals with supports Fused bayonet no isolation link t f Oil -immersed partial range current limiting fuse ANSI specific staggered low voltage pattern 2-position 200 amp LBOR transformer switch Fuse/switch interlock mechanism Spare expulsion fuses (set of 6) Dial type thermometer Liquid level gauge Drain valve and sampler Touch up paint (12 oz spray can) Mineral oil with inhibitor 24" deep cabinet Provision for one (1) conduit entrance Special label(s) and/or decal(s) Additional nameplate Integral LV Spade ITEM QUANTITY KVA NET EACH SHIPMENT CUSTOMER CODE 8 6 2500 16095 8-10 ---------------------------------------------------------------------- Prices are firm for shipments through 12/31/04 for all items awarded ABB within 45 days of bid opening. Losses quoted are guaranteed average, ANSI tolerances apply. Nameplate will state "Filled with non -PCB mineral oil that contained less than 1 PPM at time of manufacture". Negotiation and item numbers must be referenced upon order entry. Shipment subject to available production space at time of order receipt.at division. All door fastening bolts are made of AISI 300 series stainless steel or silicon bronze for corrosion resistance in full compliance with ANSI C57.12.28-1988. View the status of your orders by visiting web site at <www.abbdtd.com> View requested construction drawings electronically at the same site: Order status, upper right hand corner, click on nameplate icon or drawing icon. Generally not available less than two weeks after order entry, unless a duplicate style is ordered. Prices are F.O.B. point of shipment. ABB INC. General Terms and Conditions of Sale, ABBGTC073101 and supplemental terms and conditions, July 2002, apply. Orders for renewal parts and transformers cannot be combined on the same order - they must be entered on separate orders. f3?? January, 2002 The ABB MTR is an oil -filled, three-phase, commercial padmounted distribution transformer specifically designed for servicing such underground distribution loads as shopping centers, schools, institutions and industrial plants. It is available In both live front and dead front construction, for radial or loop feed applications, with or without taps. ABB MTR meets the following Industry standards: ANSI C57.12.00 ANSI C57.12.22 ANSI C57.12.26 ANSI C57.12.28 ANSI C57.12.29 ANSI C57.12.70 ANSI C57.12.80 ANSI C57.12.90 ANSI C57.91 NEMA TR1 WUG 2.13 Rev. 4 Ratings • 45 through 1500 kVA • 65• C average winding rise • 60 hertz standard, 50 hertz optional • High voltages: 4160 Grd Y/2400 through 34,500 Grd Y/19,920 for Grounded Wye systems; 2400 through 34,500 for Delta systems; various dual high voltages • Taps: All voltages are available with or without taps • Insulation classes: 35 kV, 150 kV BIL and below ABB Inc. Distribution liansformers Athens, GA Jefferson City, MO I1SO 9001 Cer Med • Low voltages: 208Y/120, 216Y/125, 460Y/265, 480Y/277, 480A, 240A and 240A with 120 volt mid -tap in one phase; (4160Y/2400, 4160A, 2400A, 2400/4160Y/2400 for 500 kVA and larger) Standard Features: 1. Four lifting lugs. 2. Bolted -on terminal compartment (18" deep) with removable front sill. 3. Hinged, lift-off cabinet doors. 4. Interlocked penta-head bolt/padlock handle operates a cam assembly which is part of the 3-point door latching mechanism. (A hex -head bolt is available.) 5. For live front construction, externally clamped high voltage porcelain bushings with a single eyebolt, clamp -type connector (accommo- dates #6 AWG solid to 250 MCM stranded conductors). 6. For dead front construction, exter- nally clamped high voltage bushing wells for loadbreak or non-loadbreak inserts. 7. Lightning arrester mounting pads (live front only). 8. Tank ground pads (1 in HV, 1 in LV) 9. Steel high/low voltage compartment barrier. 10. Two 1/2" penta-head bolts must be removed from the flange formed on the steel high/low barrier before the HV door can be opened (1/2" hex - head bolts available as an option). PDL 46-301 Page 1 MTR Three Phase Padmounted Transformer 45-1500M 11. Externally clamped low voltage bushings with threaded copper stud for full load current below 2100 amps. Externally clamped integral low voltage bushings for current above 2100 amps. NEMA spades provided per ANSI hole requirements. 12. Nameplate. 13. Fill plug and self -actuating pressure relief device. 14. Drain plug. 15. Removable neutral ground strap. 16. Five -legged core/coil assembly. 17. Handhole cover bolted onto tank top (protected by weathercover). 18. Panel -type coolers. 19. NEMA safety labels. 20. The paint finish process applies a durable, corrosion resistant finish to the product. The finish meets or exceeds all the performance require- ments of ANSI C57.12.28. The multi- step process Includes an epoxy primer uniformly applied by cationic electro- deposition and a urethane top coat. Optional Features Primary Termination • Externally -clamped bushing wells with loadbreak or non-loadbreak inserts. • Integral loadbreak bushings. Secondary Termination • Externally -clamped bushings with NEMA 6-hole, 8-hole, 10-hole, or 12-hole spades. • Spade supports are available. They are provided for 8-hole spades and larger when the current is 1400 amps or greater. Primary Switching • LBOR oil switch: one for radial, two for loop feed. • Externally -operated tap changer. • Externally operated dual voltage switch. • Externally operated delta-wye switch. Overcurrent Protection • Internal primary protective links. • Bayonet -type expulsion fuses. • Drawout, loadbreak current limiting fuses, with or without interlocking transformer switch. • Secondary oil circuit breaker. • Internal, partial -range current limiting fuses. Overvoitage Protection • Distribution class, metal oxide arresters, 3-36 kV. • Distribution class, valve -type lightning arresters, 3-27 kV. Construction Options • 24" and 30" deep terminal cabinet. • Drain valve and sampling device. • Mounting plate for CT's or PT's. • Interphase barriers. • Molded case external secondary breaker. • Substation Accessories - Oil gauge, thermometer, drain valve and sampler, pressure -vacuum gauge provision. • Weathercover. • Transformers may feature an optional weathercover over the cabinet which Is hinged to allow clearance for replacement of the bayonet -type fuses. • The weathercover can be lifted easily into place and secured with a single supporting arm. . • The weathercover requires no additional holddown hardware. Live Front, Radial Feed ANSI Fig. 1, 2, and 3 (C57.12.22) Gal. of KVA A B C D E Wt. Oil 75 54.5 56 44.8 44.8 56 2280 115 112 54.5 56 44.8 44.8 56 2400 115 150 54.5 56 44.8 44.8 56 2700 125 225 54.5 56 49.8 46.8 56 3350 150 300 54.5 60 50.8 46.8 56 3650 165 500 58.5 66 58.8 48.8 56 5200 200 750 66.5 81 60.8 50.8 66 7100 270 1000 66.5 84 62.8 52.8 66 7900 320 1500 66.5 86 66.8 54.8 66 9700 390 Dead Front, Radial Feed ANSI Fig. 1, 3, and 4 (C57.12.26) Gal, of KVA A B C D E Wt. Oil 75 46.5 62 44.8 44.8 62 2350 115 112 46.5 62 44.8 44.8 62 2450 115 150 46.5 62 44.8 44.8 62 2700 125 225 46.5 62 49.8 46.8 62 3400 150 300 46.5 62 50.8 46.8 62 3700 165 500 54.5 66 58.8 48.8 62 5400 200 750 58.5 81 60.8 50.8 66 7100 270 1000 66.5 84 62.8 52.8 66 7900 320 1500 66.5 86 66.8 54.8 66 9700 390 Dead Front, Loop Feed ANSI Fig. 2, 3, and 4 (C57.12.26) Gal. of KVA A B C D E Wt. Oil 75 54.5 66 44.8 44.8 66 2400 120 112 54.5 66 44.8 44.8 66 2500 120 150 54.5 66 44.8 44.8 66 2800 130 225 54.5 66 49.8 46.8 66 3500 160 300 54.5 66 50.8 46.8 66 3800 170 500 54.5 68 58.8 48.8 66 5600 200 750 66.5 82 60.8 50.8 70 7400 270 1000 66.5 86 62.8 52.8 70 8200 320 1500 66.5 88 66.8 54.8 70 10300 390 Design Dimensions Approximate weights and dimensions: Dimensions are in inches, weights are in pounds. Dimensions may change to meet the customer spec. Top View (____7 MAXIMUM PAD DIMENSIONS L I MINIMUM CABLE OPENING Sid. VI_ Front View 3" MIN. _I ABB Inc. Distribution Transformers Athens, GA Jefferson City, MO January, 2002 ISO 9001 Certmed January, 2002 The ABB MTR is an oil -filled, three-phase, commercial padmounted distribution transformer specifically designed for servicing such underground distribution loads as shopping centers, schools, institutions and industrial plants. It Is available in both live front and dead front construction, for radial or loop feed applications, with or without taps. ABB MTR meets the following industry standards: ANSI C57.12.00 ANSI C57.12.22 ANSI C57.12.26 ANSI C57.12.28 ANSI C57.12.29 ANSI C57.12.70 ANSI C57.12.80 ANSI C57.12.90 ANSI C57.91 NEMA TR1 WUG 2.13 Rev. 4 Ratings • 45 through 1500 WA • 65° C average winding rise • 60 hertz standard, 50 hertz optional • High voltages: 4160 Grd Y/2400 through 34,500 Grd Y/19,920 for Grounded Wye systems; 2400 through 34,500 for Delta systems; various dual high voltages • Taps: All voltages are available with or without taps • Insulation classes: 35 kV, 150 kV BIL and below ABB Inc. Distribution Transformers Athens. GA Jefferson City, Mo ISO 9001 certMed • Low voltages: 208Y/120, 216Y/125, 460Y/265, 480Y/277, 480A, 240A and 240A with 120 volt mid -tap in one phase; (4160Y/2400, 4160A, 2400A, 2400/4160Y/2400 for 500 WA and larger) Standard Features: 1. Four lifting lugs. 2. Bolted -on terminal compartment (18" deep) with removable front sill. 3. Hinged, lift-off cabinet doors. 4. Interlocked penta-head bolt/padlock handle operates a cam assembly which Is part of the 3-point door latching mechanism. (A hex -head bolt is available.) 5. For live front construction, externally clamped high voltage porcelain bushings with a single eyebolt, clamp -type connector (accommo- dates #6 AWG solid to 250 MCM stranded conductors). 6. For dead front construction, exter- nally clamped high voltage bushing wells for loadbreak or non-loadbreak Inserts. 7. Lightning arrester mounting pads (live front only). 8. Tank ground pads (1 In HV, 1 In LV) 9. Steel high/low voltage compartment barrier. 10. Two 1/2" penta-head bolts must be removed from the flange formed on the steel high/low barrier before the HV door can be opened (1/2" hex - head bolts available as an option). PDL 46-301 Page 1 MTR Three Phase Padmounted Transformer 45-1500kVA 11. Externally clamped low voltage bushings with threaded copper stud for full load current below 2100 amps. Externally clamped Integral low voltage bushings for current above 2100 amps. NEMA spades provided per ANSI hole requirements. 12. Nameplate. 13. Fill plug and self -actuating pressure relief device. 14. Drain plug. 15. Removable neutral ground strap. 16. Five -legged core/coil assembly. 17. Handhole cover bolted onto tank top (protected by weathercover). 18. Panel -type coolers. 19. NEMA safety labels. 20. The paint finish process applies a durable, corrosion resistant finish to the product. The finish meets or exceeds all the performance require- ments of ANSI C57.12.28. The multi- step process Includes an epoxy primer uniformly applied by cationic electro- deposition and a urethane top coat. Optional Features Primary Termination • Externally -clamped bushing wells with loadbreak or non-loadbreak inserts. • Integral loadbreak bushings. Secondary Termination • Externally -clamped bushings with NEMA 6-hole, 8-hole, 10-hole, or 12-hole spades. • Spade supports are available. They are provided for 8-hole spades and larger when the current is 1400 amps or greater. Primary Switching • LBOR oil switch: one for radial, two for loop feed. • Externally -operated tap changer. • Externally operated dual voltage switch. • Externally operated delta-wye switch. Overcurrent Protection • Internal primary protective links. • Bayonet -type expulsion fuses. • Drawout, loadbreak current limiting fuses, with or without interlocking transformer switch: • Secondary oil circuit breaker. • Internal, partial -range current limiting fuses. Overvoltage Protection • Distribution class, metal oxide arresters, 3-36 kV. • Distribution class, valve -type lightning arresters, 3-27 kV. Construction Options • 24" and 30" deep terminal cabinet. • Drain valve and sampling device. • Mounting plate for CT's or PT's. • Interphase barriers. • Molded case external secondary breaker. • Substation Accessories - Oil gauge, thermometer, drain valve and sampler, pressure -vacuum gauge provision. • Weathercover. • Transformers may feature an optional weathercover over the cabinet which is hinged to allow clearance for replacement of the bayonet -type fuses. • The weathercover can be lifted easily Into place and secured with a single supporting arm. • The weathercover requires no additional holddown hardware. Live Front, Radial Feed ANSI Fig. 1, 2, and 3 (C57.12.22) Gal. of KVA A B C D E Wt. Oil 75 54.5 56 44.8 44.8 56 2280 115 112 54.5 56 44.8 44.8 56 2400 115 150 54.5 56 44.8 44.8 56 2700 125 225 54.5 56 49.8 46.8 56 3350 150 300 54.5 60 50.8 46.8 56 3650 165 500 58.5 66 58.8 48.8 56 5200 200 750 66.5 81 60.8 50.8 66 7100 270 1000 66.5 84 62.8 52.8 66 7900 320 1500 66.5 86 66.8 54.8 66 9700 390 Dead Front, Radial Feed ANSI Fig. 1, 3, and 4 (C57.12.26) Gal, of KVA A B C D E Wt. Oil 75 46.5 62 44.8 44.8 62 2350 115 112 46.5 62 44.8 44.8 62 2450 115 150 46.5 62 44.8 44.8 62 2700 125 225 46.5 62 49.8 46.8 62 3400 150 300 46.5 62 50.8 46.8 62 3700 165 500 54.5 66 58.8 48.8 62 5400 200 750 58.5 81 60.8 50.8 66 7100 270 1000 66.5 84 62.8 52.8 66 7900 320 1500 66.5 86 66.8 54.8 66 9700 390 Dead Front, Loop Feed ANSI Fig, 2, 3, and 4 (C57.12.26) Gal. of KVA A B C D E Wt. Oil 75 54.5 66 44.8 44.8 66 2400 120 112 54.5 66 44.8 44.8 66 2500 120 150 54.5 66 44.8 44.8 66 2800 130 225 54.5 66 49.8 46.8 66 3500 160 300 54.5 66 50.8 46.8 66 3800 170 500 54.5 68 58.8 48.8 66 5600 200 750 66.5 82 60.8 50.8 70 7400 270 1000 66.5 86 62.8 52.8 70 8200 320 1500 66.5 88 66.8 54.8 70 10300 390 Design Dimensions Approximate weights and dimensions: Dimensions are in inches, weights are In pounds. Dimensions may change to meet the customer spec. Top View 76"--�3"MIN F - - MAXIMUM PAD DIMENSIONS L MINIMUM CABLE OPENING Front View ABB Inc. Distribution Transformers Athens, GA Jefferson City, MO 180 9001 Certified January, 2002 jklill January, 2002 The ABB MTR Is an oil -filled, three-phase, commercial padmounted distribution transformer specifically designed for servicing such underground distribution loads as shopping centers, schools, Institutions and industrial plants. It is available in both live front and dead front construction, for radial or loop feed applications, with or without taps. ABB MTR meets the following Industry standards: ANSI C57.12.00 ANSI C57.12.22 ANSI C57.12.26 ANSI C57.12.28 ANSI C57.12.29 ANSI C57.12.70 ANSI C57.12.80 ANSI C57.12.90 ANSI C57.91 NEMA TR1 WUG 2.13 Rev. 4 Ratings • 2000 through 2500 WA • 65° C average winding rise. • 60 hertz standard, 50 hertz optional • High voltages: 7200 Grd Y/4160 through 34,500 Grd Y/19,920 for Grounded Wye systems; 4160 through 34,500 for Delta systems; various dual high voltages ABB Inc. Distribution Transformers Athens, GA Jefferson City, MO ISO 9001 certiffed • Taps: All voltages are available with or without taps • Insulation classes: 35 W, 150 kV BIL and below • Low voltages: 460Y/265, 480Y/277, 480A,4160Y/2400, 2400A,2400/ 4160Y/2400 Standard Features: 1. Four lifting lugs. 2. Bolted -on terminal compartment (24" deep) with removable front sill. 3. Hinged, lift-off cabinet doors. 4.Interlocked penta-head bolt/padlock handle operates a cam assembly which Is part of the 3-point door latching mechanism. (A hex -head bolt Is available.) 5. For live front construction, externally clamped high voltage porcelain bushings with a single eyebolt, clamp - type connector (accommodates #6 AWG solid to 250 MCM stranded conductors). 6. For dead front construction, externally clamped high voltage bushing wells for loadbreak or non-loadbreak inserts. 7. Lightning arrester mounting pads (live front only). 8. Tank ground pads (1 in HV, 1 in LV). 9. Steel highAow voltage compartment barrier. PDL 46-302 Page 1 MTR Three Phase Padmounted Transformer 2000-2500 WA 10. Two 1/2" penta-head bolts must be removed from the flange formed on the steel high/low barrier before the HV door can be opened (1/2" hex -head bolts available as an option). 11. Externally clamped low voltage bushings with NEMA 10-hole spades. 12. Nameplate. 13. Fill plug and self -actuating pressure relief device. 14. Drain plug. 15. Removable neutral ground strap. 16. Five -legged core/coil assembly. 17. Handhole cover bolted onto tank top (protected by weathercover). 18. Panel -type coolers. 19. NEMA safety labels. 20. The paint finish process applies a durable, corrosion resistant finish to the product. The finish meets or exceeds all the performance require- ments of ANSI C57.12.28. The multi- step process includes an epoxy primer uniformly applied by cationic elec- trodeposition and a urethane top coat. Optional Features Primary Termination • Externally -clamped bushing wells with loadbreak or non-loadbreak Inserts. • Integral loadbreak bushings. Secondary Termination • Externally -clamped bushings with NEMA 6-hole, 8-hole, 10-hole, or 12- hole spades, • Spade supports are available. They are provided for 8-hole spades and larger when the current Is 1400 amps or greater. Primary Switching • LBOR oil switch: one for radial, two for loop feed. • Externally -operated tap changer. • Externally operated dual voltage switch • Externally -operated delta-wye switch. Overcurrent Protection • Internal primary protective links. • Bayonet -type expulsion fuses. • Internal, partial -range current limiting fuses. Overvoltage Protection • Distribution class, metal oxide arresters, 3-36 kV. • Distribution class, valve -type lightning arresters, 3-27 kV. Construction Options • 18" and 30" deep terminal cabinet. • Drain valve and sampling device. • Mounting plate for CT's or PT's. • interphase barriers. Design Dimensions Approximate weights and dimensions: Dimensions are in Inches, weights are in pounds. Dimensions may change to meet the customer spec. Live Front, Radial Feed Dead Front, Radial Feed ANSI Fig. 1, 2, and 3 ANSI Fig. 1, 3, and 4 (C57.12.22) (C57.12.26) Gal. of KVA A B C D E Wt. Oil 2000 70.5 92 68.8 58.8 70 12800 430 2500 70.5 98 70.8 58.8 70 14100 500 Top View Front View (Dimensions are In Inches.) Molded case external secondary breaker. Substation Accessories - Oil gauge, thermometer, drain valve and sampler, pressure -vacuum gauge provision. Weathercover. • Transformers may feature an optional weathercover over the cabinet which Is hinged to allow clearance for replacement of the bayonet -type fuses. • The weathercover can be lifted easily into place and secured with a single supporting arm. • The weathercover requires no additional holddown hardware. Dead Front, Loop Feed ANSI Fig. 2, 3, and 4 (C57.12.26) 3iMIN. MAXIMUM PAD DIMENSIONS 70" L____ 42" 15.5" MINIMUM CABLE OPENING 5" ABB Inc. Distribution Transformers Athens, GA Jefferson City, MO January, 2002 ISO 9001 Cert fled January, 2002 The ABB MTR is ari oil -filled, three-phase, commercial padmounted distribution transformer specifically designed for servicing such underground distribution loads as shopping centers, schools, institutions and industrial plants. It is available in both live front and dead front construction, for radial or loop feed applications, with or without taps. ABB MTR meets the following industry standards: ANSI C57.12.00 ANSI C57.12.22 ANSI C57.12.26 ANSI C57.12.28 ANSI C57.12.29 ANSI C57.12.70 ANSI C57.12.80 ANSI C57.12.90 ANSI C57.91 NEMA TR1 WUG 2.13 Rev. 4 Ratings • 2000 through 2500 kVA • 65• C average winding rise • 60 hertz standard, 50 hertz optional • High voltages: 7200 Grd Y/4160 through 34,500 Grd Y/19,920 for Grounded Wye systems; 4160 through 34,500 for Delta systems; various dual high voltages ABB Inc. Distribution Transformers Athens, GA Jefferson City, MO ISO 9001 CertMed Taps: All voltages are available with i without taps Insulation classes: 35 kV, 150 kV BIL and below Low voltages: 460Y/265, 480Y/277, 480A, 4160Y/2400, 2400A, 2400/ 4160Y/2400 Standard Features: 1. Four lifting lugs. 2. Bolted -on terminal compartment (24" deep) with removable front sill. 3. Hinged, lift-off cabinet doors. 4. Interlocked penta-head bolt/padlock handle operates a cam assembly which is part of the 3-point door latching mechanism. (A hex -head bolt is available.) 5. For live front construction, externally clamped high voltage porcelain bushings with a single eyebolt, clamp - type connector (accommodates #6 AWG solid to 250 MCM stranded conductors). 6. For dead front construction, externally clamped high voltage bushing wells for loadbreak or non-loadbreak Inserts. 7. Lightning arrester mounting pads (live front only). 8. Tank ground pads (i in HV, 1 in LV). 9. Steel high/low voltage compartment barrier. PDL 46-302 Page 1 MTR Three Phase Padmounted Transformer 2000-2500 kVA 10. Two 1/2" penta-head bolts must be removed from the flange formed on the steel high/low barrier before the HV door can be opened (1/2" hex -head bolts available as an option). 11. Externally clamped low voltage bushings with NEMA 10-hole spades. 12. Nameplate. 13. Fill plug and self -actuating pressure relief device. 14. Drain plug. 15. Removable neutral ground strap. 16. Five -legged core/coil assembly. 17. Handhole cover bolted onto tank top (protected by weathercover). 18. Panel -type coolers. 19. NEMA safety labels. 20. The paint finish process applies a durable, corrosion resistant finish to the product. The finish meets or exceeds all the performance require- ments of ANSI C57.12.28. The multi- step process includes an epoxy primer uniformly applied by cationic elec- trodeposition and a urethane top coat. Optional Features Primary Termination • Externally -clamped bushing wells with loadbreak or non-loadbreak Inserts. • integral loadbreak bushings. Secondary Termination • Externally -clamped bushings with NEMA 6-hole, 8-hole, 10-hole, or 12- hole spades. • Spade supports are available. They are provided for 8-hole spades and larger when the current Is 1400 amps or greater. Primary Switching • LBOR oil switch: one for radial, two for loop feed. • Externally -operated tap changer. • Externally operated dual voltage switch • Externally -operated delta-wye switch. Overcurrent Protection • Internal primary protective links. • Bayonet -type expulsion fuses. • Internal, partial -range current limiting fuses. Overvoltage Protection • Distribution class, metal oxide arresters, 3-36 kV. • Distribution class, valve -type lightning arresters, 3-27 kV. Construction Options • 18" and 30" deep terminal cabinet. • Drain valve and sampling device. • Mounting plate for CT's or PT's. • Interphase barriers. Design Dimensions Approximate weights and dimensions: Dimensions are in Inches, weights are in pounds. Dimensions may change to meet the customer spec. Live Front, Radial Feed Dead Front, Radial Feed ANSI Fig. 1, 2, and 3 ANSI Fig. 1, 3, and 4 (C57.12.22) (C57.12.26) Gal. of KVA A B C D E Wt. OII 2000 70.5 92 68.8 58.8 70 12800 430 2500 70.5 98 70.8 58.8 70 14100 500 Top View I'-- B r -76" • Molded case external secondary breaker. • Substation Accessories - Oil gauge, thermometer, drain valve and sampler, pressure -vacuum gauge provision. • Weathercover. • Transformers may feature an optional weathercover over the cabinet which Is hinged to allow clearance for replacement of the bayonet -type fuses. • The weathercover can be lifted easily Into place and secured with a single supporting arm. • The weathercover requires no additional holddown hardware. Dead Front, Loop Feed ANSI Fig. 2. 3, and 4 (C57.12.26) 3" MIN. I F-- MAXIMUM PAD DIMENSIONS 70" L - 42"' 15.t MINIMUM CABLE OPENING I c" Front View (Dimensions are In Inches.) ABS Inc. Distribution Transformers Athens, GA Jefferson City, MO ISO 9001 certMed January, 2002 ABB Inc. Small Power Transformers P.O. Box 38, State Route 42 Bland, VA 24315 Quote dated 10/31 /2003 Prepared for: City of Vernon Project: City of Vernon In response to your request for quotation we are pleased to offer the following: ABB Quote number: DIR03199 Item number: 001 Quantity 2 3750 KVA Padmount 3 Phase 60 Hertz Oil Filled 65 Degree C Rise OA Self Cooled 30 Average/ 40 Maximum Ambient 6.00 Percent Impedance Guaranteed Minimum Impedance Phase relation: DYN 1 3300 Feet Maximum Altitude 64 dB(a) Guaranteed Sound Level (OA) Guaranteed Loss $ Evaluation: No load loss - 3420 Watts Total loss - 30500 Watts HIGH VOLTAGE High Voltage 16340 Delta 110KV BIL Wall Mounted Bushings in ANSI Segment 1 Aluminum Conductor Tap5: 15480, 15910, 16340, 16770, 17200 Radiai feed ABB LBOR 300 ampere 35 KV 150 KV BIL load break switch. Three 200 Amp Bushing Wells LOW VOLTAGE Low Voltage 480YI277 30KV BIL Wall Mounted Bushings in ANSI Segment 1 Aluminum Conductor Welded on Aluminum Cast Resin Epoxy Bushings CORE/COIL DUTY FINISH FITTINGS Parking Stands - Radial Feed Seismic Anchoring/Construction Outdoor Service Telephone Green 5 Mils C57.12.28-1995 Paint Standard Undercoating Tank Base + 1" Up Side Shot Blasting Of Tank Vacuum/Upper Filter Press Connection - 1" Plug 1" Drain Valve with 3/8" Sampler Valve MONITORING SHIPPING TANK TERMINATION TEST Dial Type Thermometer Provisio Liquid Level Gauge Pressure Relief Valve Vacuum Pressure Gauge Provisions FOB Destination Prepaid Formed Base with Jacking Provisions Stainless Steel Ground Pads Cork Neoprene - All Gauge Gaskets Standard Handhole - Bolted Sealed Tank Design 15 PSI Tank Design Standard Welded on Flat Tubular Radiators Three Point Hinged Door on Compartment Approval of Certified Test Report Required Before Shipment Price Item 001 : $43,720 USD Net Each Transformer COMMENTS AND EXCEPTIONS: *' Quotation is based on the above Bill of Material only. 5.1.A - A three-legged, stacked core shall be provided by ABB, Inc. 5.6.6 - A bolted manhole cover shall be provided. The transformer tank cover shall be welded assembly. 6.2 & 7.0 - Not applicable per spec page 11 of 16. Lead Times: Drawing Submittal A-6 Weeks after receipt of order. Approval Order (Shipment) :10-12 Weeks after return of approved drawings. Firm Order (Shipment) :10-12 Weeks after receipt of order. Transformers are designed, built and tested to ANSI/IEEE C57 Transformer Standards. No other Codes/Standards apply (NEC, NESC, etc.) unless noted on quote. "GENERAL TERMS AND CONDITIONS OF SALE** This quotation is effective for 30 days from 10/31/2003, unless otherwise authorized by ABB. Unless stated otherwise in this quotation, the following terms and conditions of sale will apply 1. FOB Destination Prepaid 2. Payment is due net 30 days from invoice date. 3. Terms and conditions of sale are based upon ABB Inc. General Terms and Conditions of Sale. 4. Escalation: Prices will remain firm for 180 days from date of receipt of order. After 180 days, prices will be escalated 0.5% for each additional 30 day period, or portion thereof, from the date of the order to the date of the shipment, unless other conditions have been previously negotiated. We appreciate the opportunity to quote on this business. The ABB Small Power Transformers has had many years of experience building reliable, high quality transformers and we look forward to supplying this equipment. If there are any questions regarding this quotation or any other matter relating to this job please call me at your convenience. Quoted lead times are based on current production levels. Actual lead times are dependent on available production space at time of order entry and/or release to manufacturing. TRANSFORMER PERFORMANCE DATA ABB Quote No.: DIR03199 Item No.: 001 itVA: 3750 Impedance: 6.00 Hertz: 60 Cooling Medium: Air Rise: 65 Cooling Class: OA Stated Values Are Guaranteed Losses %LOAD 1% ITOTAL LOSS EFFICIENCY INO-LOAD LOSS ILOAD LOSS 25 1,690 5,110 99.46 I 3,420 50 99.46 3,420 6,770 10,190 75 9.9.34 ( 3,420 15,230 18,650 100 i 99.19 i 3,420 i 27,080 i 30,500 EFFICIENCY IS CALCULATED AT UNITY POWER FACTOR REGULATION WITH A LAGGING POWER FACTOR % LOAD POWER FACTORi 100 100 1 0.88 95 2.67 90 3.35 85 = 3.84 80 4.23 75 4.54 70 4.81 REGULATION BASED ON: X = 5.9510 % R = 6.7005 X/R = 8:4957 % Fe = 0.0912 %EXCITING % VOLTS I NO LOAD LOSS CURRENT au 1 2,U52 0.23 90 2,736 0.41 100 I 3,420 0.73 105 I 4,104 1.19 110 5,130 ( 2.74 POWER FACTOR 1.00 0.95 0.90 0.85 0.80 %LOAD 1% EFFICIENCY % EFFICIENCY1% EFFICIENCY.% EFFICIENCY % EFFICIENCY 25 1 99.45 1 99.42 1 99.39 I 99.36 1 99.32 50 1 99.45 1 99.43 1 99.39 1 99.36 1 99.32 75 1 99.34 1 99.30 ( 99.26 1 99.22 1 99.17 100 i 99.19 i 99.15 i 99.10 i 99.05 i 98.99 1 , 1 , I 1 I 0x ON 0 W 0� 0 0 i 0 w 1 1 I ' I 1 ' r ' i 1 c 11 I ' I ' ' ` 1 , I 1 ' I ' 1 ' I ' , I 1 ' , I , I I 1 1 I I I 1 I I 1 I I I I I 1 I I I 1 1 I 1 , o O N .-. m CD ^'s O V (D Co v� CD Co CD m y � Iz a n o CD x y. 0 4 r 0 a 1 � 1 u + 1 1 + 1 + 1 1 1 1 1 1 + + 1 1 1 -►1 I I 1 1 I 1 1 + 1 + ■ 1 + 1 • 1 + 1 1 � t u + I t 1 1 I 1 J + + 1 1 1 + 1 _ 1 1 1 1 1 1 + 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 I 1 o � 0 w O c ~ rn r. o co � 0 s r Vl� o � Vl K O <z CD o Ncc +D (IQ O c � A � 0 b� ti N�1 y O C" v, SPECIFICATION NO. TR2-2003 PADMOUNT TRANSFORMER CITY OF VERNON LIGHT AND POWER SEPTEMBER 15, 2003 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 1.0 SCOPE Supplier shall furnish all work for providing three-phase, deadfront, radial, self cooled, padmounted transformers for use on the City of Vernon's underground distribution system. The transformer sizes that the City requires are listed in Attachment A. This list does not preclude the possibility of ordering voltage and KVA ratings not listed under this specification. 2.0 APPLICABLE STANDARDS A. The transformers shall conform to the applicable sections of the following standards to the extent referenced in this Specification, and as amended to the date of this Specification which, by reference, are included as part of this Specification. 1. C57.12.00 IEEE Standard General Requirements for Liquid - Immersed Distribution, Power, and Regulating Transformers. 2. C57.12.26 Requirements for Padmounted Compartmental - Type, Self Cooled, Three -Phase Distribution Transformers for Use with Separable Insulated High Voltage Connectors, High Voltage 34500GrdY/19920 Volts and Below, 2500 kVA and Smaller. 3. C57.12.28 Padmounted Equipment —Enclosure Integrity. 4. C57.12.90 IEEE Standard Test Code for Liquid -Immersed Distribution, Power, and Regulating Transformers and IEEE Guide for Short -Circuit Testing of Distribution and Power Transformers. 5. C57.91 Guide for Loading Mineral -Oil -Immersed Overhead and Padmounted Transformers Rated 500 kVA and Less with 650C or 550C Average Winding Rise. 6. C57.92 Guide for Loading Mineral -Oil -Immersed Power Transformers Up to and including 100 MVA with 650C or 550C Average Winding Rise. 7. C57.106 IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment. B. In the event of conflict between the codes and standards and this Specification, Supplier shall notify City of Vernon Light and Power Department and secure a written clarification before proceeding with the work. 3of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 3.0 SERVICE CONDITIONS 3. 1. Environment A. The transformers shall perform in accordance with all provisions of T the Specification while subject to the service conditions specked in ANSI/IEEE C57.12.00. B. The transformer shall be suitable for 30 years of use on the City of Vernon's electric system when installed in accordance with the service conditions set forth in ANSI/IEEE C57.12.00-1987, Section 4.0, in its entirety. 3. 2. Seismic and Impact Loading A. Before and during installation, the transformers shall withstand, without damage, rough handling such as bouncing on a truck when filled with insulating medium and impacting against or upon rigid structures at speeds up to five feet per second, and being lifted by two bosses or lifting second, and being lifted by two bosses or lifting bolts at any angle. Following these conditions, the transformers shall be capable to being energized without a pre- operational test. B. After installation and during the 30-year life of transformer, transformer will be subject to occasional earthquake motions (0.2g horizontal and 0.13g vertical) along with significant vibrations from traffic and from adjacent equipment. 3.3 Pre -installation Inspection The City of Vernon will, at its discretion, provide a pre -installation inspection of each transformer. 3.4 Operating Duty For its 30-year life, each transformer shall be suitable for operation under short circuit conditions as stated in ANSI/IEEE C57.12.00-1987, Section 7.1. 4of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 3.5 ahjpgjqg A. All transformers shall be shipped to the City of Vernon, Soto Yard located at 2800 Soto Avenue, Vernon, CA 90058. Supplier's price shall be F.O.B. Soto Yard. B. Transformers will be delivered on a flatbed truck for side unloading by forklift at ground level. C. Delivery will be scheduled Monday through Thursday 7:00 a.m. to 3:00 P.M. Supplier shall provide City with 48 hours notice prior to delivery. 4.0 RATINGS 4.1 Sizes The transformers shall be sized as shown in Attachment A. 4.2 High Voltage Ratings Transformers shall be 60 Hz with BIL ratings as shown in the table below. Transformer and Connector High Voltaa Ratings and Electrical Characteristics Transformer Electrical Characteristics of the Completely Assembled High -Voltage Connectors'' High -Voltage Rating 2' Phase -to -Ground /Phase -to- Phase (kV) BIL (kV) 60-Hz dry one minute withstand (kV) High -Voltage Ratings (volts) Minimum BIL3- (kV) gle High -Voltage [7200 40 75 95 8.3/14.4 8.3/14.4 95 95 34 34 Series -Multiple High - Voltage 7200 x 16430 75 x 95 8.3/14.4 95 34 For complete connector rating, see ANSI/IEEE 386. 2 Transformers are suitable for connectors with phase -to -ground or phase-to-ground/phase-to-phase s high -voltage ratings as listed. Arrester coordination may require higher BIL on multiple connection than indicated to achieve a minimum protection level of 20%. 5of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 4.3 Low Voltage Rating The secondary voltage shall be one of the following. The basic insulation level (BIL) of the secondary voltage shall be 30 M 480Y/277 208Y/120 4.4 Configuration All transformers shall be Delta -Wye configured with low voltage neutral having a fully insulated Xo bushing with a removable ground strap. 4.5. Impedances Transformer impedance shall not be less than those shown in the table below. All transformer testing to determine transformer impedance shall be based on the base kVA rating of the transformers at the 55 degree or 65 _degree temperature rise. The transformer impedances shall be shown on the transformer nameplate. Minimum Transformer Impedance KVA %Z 300-500 4.0 750-2500 5.75 3750 6.00 5.0 CONSTRUCTION FEATURES 5.1 Coil and Core Construction A. The transformer core shall be of high efficiency rectangular wound core designed in five -leg or triplex configurations. The core shall be made from one of two processes: single -turn laminations of high quality, grain oriented silicon core steel or amorphous core (Le metallic glasses metal). B. The transformer coils shall be designed to maintain their nameplate KVA rating throughout the normal temperature range of operation which shall be 65°C (80°C hot spot). All materials used shall be of the 65°C, 80°C hot spot class. All materials shall be thoroughly tested for compatibility with all transformer components before being assembled. The primary coil shall 6of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS be manufactured from heavy varnish or paper insulated aluminum or copper wire. The secondary coil shall be manufactured from full width aluminum strip whose edges are finished to prevent burrs and insulated with epoxy -diamond paper between layers of the conductor. 5.2. Insulating Fluid A. The transformer insulating fluid shall be standard electrical grade mineral insulating oil. The insulating oil shall be tested and degassed to assure a chemically inert oil. The padmount transformers shall be furnished with oil' which meets the requirements specified in ASTM Standard D 3487 for mineral insulating oil, except that the DBPC content (% by weight) shall not be less than 0.15. The insulating oil in the equipment shall conform with ANSI C57.106. B. All transformer oil shall be tested for polychlorinated biphenyl's (PCBs) per ASTM D4059 and certified as having no detectable levels of PCB. 5.3 Taps and Changers A. The transformers shall be furnished with full capacity high -voltage taps. The tap changer shall be clearly labeled to reflect that the transformer must be de -energized before operating the tap changer as required in Section 3.3 of ANSI C57.12.26. Padlocking provisions are available for lever or hotstick operable handles. Tap changer operating mechanisms shall be permanently identified to show "De -energized Operation Only". Decals and stencils are not acceptable. The unit shall have one of the following tap configurations: Two - 2%% taps above and below rated voltage such as the following: VOLTAGE FULL CAPACITY TAPS 16,340 17,200/16,770/15,910/15,480 7,200 7,560/7,380/7,020/6,840 B. The tap changer position indicating nameplate shall have numerals or letters that are clearly legible and of permanent quality. Decals and stencils are not acceptable. 7of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 5.4 Gauges A. All transformers shall have a dial -type, magnetic, oil level gauge to provide a positive means of determining the required oil height. The preferred location of the gauge is above the switch handles, to ensure the switch remains under oil. B. All transformers shall have a dial -type, magnetic, temperature gauge to provide a positive means of determining the transformer temperature. The required location of the gauge is in the low voltage compartment above the bushings. 5.5 Drain and Replacement Provisions Insulating medium drain and replacement provisions shall be furnished as specified in ANSI C57.12.26. 5.6. Tanks and Terminal Compartment A. The transformer tanks, and all external appurtenances, shall be in accordance with ANSI C57.12.26. The overall dimensions and various appurtenances locations shall be found on each transformer per Attachments C and D. B. Transformers shall have bolted covers for all size transformers. C. The compartment depth shall be minimum in accordance with figure 7 of C57.12.26. A deeper compartment shall be provided for extended secondary bushings. The tank shall be of sufficient strength to withstand a pressure of 7 psig without permanent distortion. The following pressure relief devices are approved: 1. Qualitrol Model No. 202-030-001 2. Qualitrol Model No. 202-032-001. 5.7 Terminations Transformer bushings shall accommodate cable terminations in accordance with ANSI/IEEE 386, but shall be modified to provide the height requirements of these specifications as shown in Attachments C and D. 8of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 5.8 Nameplates A stainless steel nameplate shall be attached with non -corrosive hardware to the inside of the low voltage compartment door. The nameplate shall not be installed on the rear of the low voltage compartment area. Diagrams and numbers shall be of the size and quality such that they can be read from outside the compartment. In addition to the nameplate requirements shown in ANSI/IEE C57.12.00-1987, Section 5.12, the total weight, including oil, shall be indicated. 5.9 Coating A. Each transformer and terminal enclosure combination shall be painted a forest green color such as Dulux Bell Telephone Green No. 183-Y-546 (Munsell 7.5GY2.95/2.1) or City of Vernon -approved equivalent. The primary and finishing coats shall have a combined minimum dry -film thickness of three mils. Manufacturer shall furnish 1/4 pint of touch up paint for each transformer. B. The underside of each transformer shall be coated with an asphaltic :material or with City of Vernon -approved paint system. An epoxy coat which meets ANSI C57.12.28 is acceptable. 6.0 Loadbreak Switches 6.1 'Type A. Each transformer shall have a three-phase, self-contained, oil immersed, high voltage, Loadbreak gang -operated sectionalizing switch. The switches shall be inside the transformer tank and be so located that current interruption occurs under oil. The loadbreak switches shall provide circuit connections as shown in Attachments C. and D. Operation of the switch shall be clockwise to close. B. The operating handle shall be located in the high voltage compartment and be suitable for hot stick operation. The position of the switch, whether open or closed, shall be clearly indicated. The handle shall be located in such a manner as to be identifiable with the associated circuit -transformer. Stencils or decals to indicate switch positions are not acceptable. 9 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 6.2 Interlocks The switch shall have an interlock which will prevent removal of fuses when the switch is in the closed position and also prevent the inserting of fuses when the switch is in the closed position. 6.3 Ratings The switches shall have the following ratings when completely assembled and installed in the transformers. A. Minimum Voltage Rating: 17,000 volts. B. Loadbreak Capability: 200 rms amperes at 17,000 volts and 0.6 power factor. C. Short -time current Rating: 10,000 rms symmetrical amperes for 15 cycles. D. Closing and Holding Current Rating: 10,000 rms symmetrical amperes for 15 cycles. E. There shall be no arcing time after the switch blades have traveled from the closed position to the fully opened position. 7.0 OVERCURRENT PROTECTION 7.1 High Voltage Protection A. Transformers shall be protected against overcurrent by means of a City of Vernon -approved externally replaceable fuses in the primary circuit. The fuses shall be suitable for hot stick operation and shall have a minimum of 50,000 rms symmetrical ampere interrupting rating. The fuses shall have City of Vernon -approved safety devices which prevent insertion directly into a fault. B. The fuses shall be a Bay-O-Net type oil immersed fuses in series with oil immersed current limiter type RTE ELSP current limiting backup fuse. The fuses shall have a safety device which prevent insertion directly into a fault. 10 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS C. The correct size of Bay-O-Net fuse for replacement shall be indicated by stencil or decal above the Bay-O-Net fuse as follows: "Caution: Use only RTE Bay-O-Net Type 353C "(10, 12, etc.)" " Amps" (25, 40, etc.) D. The following table lists the appropriate fuse sizes: Transformer Ratings KV KVA Rating � FLA High Voltage Fuses4 BAYONET ELSP MINIMUM Z% 16.34 300 15.5 11 4000353C10 354508OM51M 4.00 500 15.5 18 4000353C10 354508OM51 M 4.00 750 15.5 26 4000353C12 3545125M61 M 5.75 1000 15.5 35 4000353C12 3545125M61M 5.75 1500 15.5 53 4000353C16 354515OM51 M5 5.75 2000 15.5 70 4000353C16 354515OM51 MS 5.75 2500 15.5 88 NONE NONE 5.75 3750 15.5 132 NONE NONE 6.00 7.2 300 8.3 24 4000353C12 3543125M61 M 4.00 500 8.3 40 4000353C14 354308OM51M5 4.00 750 8.3 60 4000353C16 354320OM51 M 5.75 1000 8.3 80 4000353C17 3543175M51 M5 5.75 1500 8.3 120 NONE NONE 5.75 E. A minimum of 6 spare Bay-O-Net fuses shall be provided with each transformer order. For instance, if we order one 7.2 kV type 300 KVA transformer we require 6 spare fuses. If we order two such transformers, we require 12 spare fuses. 7.2 Low Voltage Protection Low voltage overcurrent protection is not required. 4 Cooper (Type Bay-O-Net and Current Limiting ELSP) 5 Two parallel fuses per phase 11 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 8.0 BUSHINGS, BUSHING WELLS AND PARKING STANDS 8.1 Low Voltage Bushings A. Transformers shall have bushings which conform to ANSI Standard C57.12.26. On "Wye" connected transformers, the neutral shall be - connected to a fully insulated bushing. An additional tank ground pad with removable neutral bushing ground strap shall be provided and suitably sized for the short circuit current rating of the transformer. B. External spade terminals shall have a heavy tin coating process. If the terminal extension is not an integral part of the bushing, it shall be securely pinned to the stud. C. External spade terminals with six holes and more shall be furnished with additional support straps, designed by the manufacturers, at the end farthest from the tank wall without interfering with the use of any of the holes. Each extension pad shall be fully rated for the maximum ampacity of the transformer. Refer to the table below for the number of terminal holes. KVA Ratings Low -Voltage Ratings (Volts) Number of 9/16" hole cable positions 75-300 ALL 4-6 M 500 ALL 8 750-1500 ALL 12 2000-2500 ALL 14 3750 ALL 16 8.2 High Voltage Bushing Wells Transformers shall be provided with three City of Vernon -approved, 17 kV high voltage bushing wells rated 95 kV BIL, marked and located as shown in Attachments C and D. 8.3 Parkinq Stands Transformers shall be equipped with non -load break parking stands, ESNA No. 151-PS or City of Vemon-approved equivalent. They shall be located as shown in Attachments C and D and in accordance with ANSI Standard C57.12.26. 12 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 9.0 IDENTIFICATION 9.1 Stencils & MSDS A. All bushings shall be identified by yellow paint stencils, a minimum of one inch high, on the tank wall adjacent to the bushings. See Attachments, C and D. B. A removable identification tag or sticker which shall be legible at time of receipt shall be attached to the exterior of the terminal compartment. The tag or sticker shall indicate the name of the manufacturer, serial number, kVA and voltage ratings. C. in addition to the nameplate information called for in ANSI C57.12.00, the nameplate shall identify each winding as to whether it is made of copper or aluminum. D. The vendor shall be required to provide all applicable Material Safety -. Data Sheets with all transformer orders. 10.0 ADDITIONAL REQUIREMENTS 10.1 Barriers A barrier shall separate the high -voltage section from the low voltage section in the terminal compartment. Barrier shall be of sufficient strength to prevent deformation which may reduce the required clearances to various components. 10.2 Conduit Entrance When specifically requested in the transformer table below, a 2 Y2 inch conduit entrance hole, with a cover which is removable only from the inside, shall be provided in the center of the low voltage sill. 13 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 10.3 Terminal Arrangements Terminal arrangements shall be as shown in Attachments C and D. 10.4 Access to Terminal and Switching Compartments A. Transformers shall be provided with hinged doors for access to the terminal and switching compartments. Access to the high voltage portion of the terminal and switching compartment shall be possible only after access has been gained to the low voltage. B. The low voltage compartment door shall be further secured by means of a captive and recessed Y2 inch pentahead bolt. A blind bolt hole shall be provided. Bolts shall be corrosion resistant and the design shall minimize the possibility of a misalignment and cross -threading. Design of the bolting, padlocking and three-point latching provisions shall be coordinated such that, only after the padlock and bolt have been removed, shall it be possible to open the low voltage compartment door. 11.0 TESTS 11.1 General A. Transformer tests shall be performed as specified in ANSI Standard C57.12.00. These test reports shall be provided to the City prior to shipping. The City will not receive any transformers without the required test reports. B. Units shall comply with routine test requirements of ANSI and certified test reports shall be furnished. The vendor shall provide with returned bids all applicable documentation of compliance with ANSI design tests. C. The following data shall be submitted with each transformer order: a. Guaranteed maximum no load (excitation) loss at rated voltage and 110% voltage in Watts. - b. Guaranteed maximum load loss in Watts at rated voltage and 110% voltage. c. Guaranteed maximum total loss in Watts at rated voltage and 110% voltage. 14 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS d. Exciting Current in percent at rated voltage and 110% rated voltage. e. Percent impedance on base voltage and at the maximum temperature rise. If the transformer is a 55/65 degree Celsius transformer rise, the percent impedance shall be at 65 degree Celsius. f. Efficiencies shall be provided at loading levels of 100%, 75%, 50%, and 25%. g. Regulation at rated load @ 80% and 100% Power Factor. h. Two sets of outline drawings showing dimensions, weight, gallons of oil, gauge of steel in tank walls, cover, bottom, and cooling radiators and description of accessories. After order is awarded, the vendor shall submit FINAL drawings. 12.0 OPERATING PERFORMANCE 12.1 General The Apparatus shall perform in accordance with the conditions set forth in this Specification. 13.0 BID EVALUATION 13.1' Total Ownership Cost Purchase of transformers shall be evaluated by lowest total ownership cost. The formula to evaluate Total Owning Cost (TOC): TOC = C + $4.53/W (PNL in Watts) + $1.1/W (PLL in Watts) Where TOC is the total ownership cost in dollars, C is the initial cost in dollars, PNL is the guaranteed maximum no-load loss in watts, and PLL is the guaranteed maximum load loss in watts For the determination of the award for the transformer order(s), City will consider all bids within 5% of the lowest Present Value Cost of Transformer to be economically equivalent. The City of Vernon realizes it is impossible to accurately predict economic conditions over the evaluation period of 30 years. 15 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 13.2 Delivery A delivery date of 16 weeks ARO or less is required. Failure to quote a delivery schedule within this period may disqualify the bid. 14.0 DOCUMENTATION 14.1 For Bid Evaluation Bidders shall furnish the following in their bid proposals: 1. Transformer unit price, F.O. B. Soto Yard. 2. Guaranteed maximum no-load loss at rated voltage in watts. 3. Guaranteed maximum load loss in watts at rated voltage and kVA. 4. Percent impedance on rated voltage tap. 5.. Two sets of dimension and outline drawings. 14.2 For Delivery Supplier shall furnish MSDS and certified test reports and drawings, as listed in Section 11.1 in this Specification one month before transformers are shipped. These documents shall be submitted to: City of Vernon Utilities Department 4305 Santa Fe Avenue Vernon Ca, 90058 Phone: (323) 583-8811 Attention: Ramon Z. Abueg Assistant Director of Engineering and Operations 16 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS Attachment A. Transformer Sizes 3 500 7.2 277/480 2 750 7.2 277/480 1 150 16.34 120/208 3 300 16.34 277/480 1 500 16.34 277/480 3 750 16.34 277/480 3 1000 16.34 277/480 2 2500 16.34 277/480 1 3750 16.34 277/480 LINE A ONE CIRCUIT (RADIAL) TWO CIRCUIT (LOOPED) CL AY-O-NET LINE A jo-- LINE B CL BAY-O-NET VERNON LIGHT AND POWER EQUIPMENT: SPECIFICATION TR2 ADDITIONAL CIRCUIT CONNECTIONS 11/2/01 i I AV NO I REVISION I DATE I APPV'D 1 64< 1 BY I ATTACHMENT 8 70" MAX RADIATORS MAY EXTEND BEYOND THE DIMENSIONS SHOWN z x PLAN SEE NOTE 2 -C EXTERNALLY REPLACEABLE CL FUSES L NAMEPLATE o uo uo H1 Hz ►+3 TRANS SW. Q o 0 N X X p 1 3 O O X x 0 2 0 z Y H1 H2 H3 a 2-1/2" CONDUIT HOLE (SEE NOTE 3) �--� 40-1/2" MIN 22" MIN. ELEVATION BAY-O-NET FUSE SCHEMATIC DIAGRAM NOTES: 1. ALL DIMENSIONS AND CLEARANCES SHALL CONFORM WITH ANSI C57.12.26. 2. CURRENT LIMITING FUSES INTERLOCKED WITH TRANSFORMER SWITCH. X ' X X X 0 1 2 3 3. 2-1/2" CONDUIT HOLE SHALL BE LOCATED IN THE CENTER (BOTH HORIZONTALLY AND VERTICALLY) OF THE LOW VOLTAGE CABINET SILL. VERNON UTILITIES DEPARTMENT EOUIPMEW: SPECIFICATION TR2 ONE -CIRCUIT PADMOUNTED TRANSFORMERS 75 THROUGH 500 KVA 0 10/30/01 - AV NO REVISION DATE APPV'D BY ATTACHMENT C VIVt-I.IRI,VII 1'NUMVVIVItU IRFiIVJr VRMCRJ 750 THROUGH 3750 KVA —B TRANSFORMER U ------------- ------ HV j LV o I AREA I AREA F---- 28" MIN 22" MIN PLAN EXTERNALLY REPLACEABLE CL FUSES L____ J NAMEPLATE JO UO UO Hi H2 93 TRANS SW. 0 0, x x 1 3 0 0 x x 0 2 ELEVATION RADIATORS MAY EXTEND BEYOND THE DIMENSIONS SHOWN DIM 750, 1000 & 1500 KVA 2000 AND 3750 KVA A 77" MAX 87" MAX B 80" MAX 85" MAX C 76" MAX 90" MAX D 26" MIN 26" MIN E 42" MIN 42" MIN SECONDARY BUSHING LOCATIONS TO CONFORM WITH ANSI STANDARD C57.12.22 - FIG. 3 2-1/2" CONDUIT HOLE (SEE NOTE 3) 6" 6" J 02-1 /2" CONDUIT HOLE ELEVATION NOTES: 1. ALL DIMENSIONS AND CLEARANCES SHALL CONFORM WITH ANSI C57.12.26. 2. CURRENT LIMITING FUSES INTERLOCKED WITH TRANSFORMER SWITCH. 3. 2-1/2" CONDUIT HOLE SHALL BE LOCATED IN THE CENTER (BOTH HORIZONTALLY AND VERTICALLY) OF THE LOW VOLTAGE CABINET SILL. VERNON LIGHT AND POWER EQUIPMENT: SPECIFICATION TR2 ONE -CIRCUIT PADMOUNTEC TRANSFORMERS 1 9/11/03 JL 750 THROUGH 3750 KVA NO REVISION DATE APPV'D i BY ATTACHMENT D EXHIBIT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 EQUIPMENT PURCHASE CONTRACT THIS AGREEMENT is made, entered into and executed in duplicate originals, either copy of which may be considered and used as the original hereof for all purposes, as of this day of November, 2003, in the City of Vernon, County of Los Angeles, California BY AND BETWEEN AND THE CITY OF VERNON (hereinafter referred to as the "City") 4305 Santa Fe Avenue Vernon, CA 90058 PAUWELS TRANSFORMERS, INC. (hereinafter referred to as "Pauwels") One Pauwels Drive Washington, MO 63090 WHEREAS, on October 14, 2003, the City requested proposals or bids for nine (9) bid items totaling nineteen (19) Padmounted Distribution Transformers (Bid No. 1429) needed by the City's Light & Power Department; and WHEREAS, the City is permitted to accept or reject any or all quotations received on the bid items; and WHEREAS, on or about November 4, 2003, the City received various proposals for the sale of Padmounted Distribution Transformers identified in Bid No. 1429, with each of the nine bid items quoted separately; and WHEREAS, on October 30, 2003, Pauwels, through its representative Pacific Utilities Supply Company, submitted a bid; and WHEREAS, on November 4, 2003, the City opened the bid submitted by Pauwels, as well as other bids for the items identified in Bid No. 1429; and WHEREAS, the City desires to purchase the following bid 1 items from Pauwels: two (2) 750 KVA 7..2 277/480 Padmounted 2 Transformers; one (1) 500 KVA 16.34 277/480 Padmounted Transformer; 3 three (3) 750 KVA 16.34 277/480 Padmounted Transformers; and, one (1) 4 3750 KVA 16.34 277/480 Padmounted Transformer, for a total of seven 5 (7) Padmounted Transformers. 6 NOW, THEREFORE, THE PARTIES HERETO DO MUTUALLY AGREE AS SET 7 FORTH HEREIN: 8 1. Purchase. Pauwels agrees to sell and deliver to the 9 City a total of seven (7) Padmounted Transformers referenced above 10 pursuant to City of Vernon Specification No. TR2-2003, as identified 11 in Pauwels' October 30, 2003 bid and which meet the specifications 12 contained in City of Vernon Bid No. 1429, dated October 14, 2003 13 (collectively referred to as the "Bid Documents"). A copy of the Bid 14 Documents are attached hereto as Exhibit "A" and incorporated herein 15 by reference. 16 2. Time of Performance. Pauwel's performance shall 17 commence upon the full execution of this Contract and shall be 18 completed by Pauwels within 10 weeks after receipt of order. 19 3. Price. The City agrees to purchase seven (7) 20 Padmounted Transformers from Pauwels for the total sum of Seventy -Nine 21 Thousand Nine Hundred Fifty -Four Dollars and No Cents ($79,954.00). 22 This price includes freight and excludes sales tax. 23 4. Delivery. Consistent with the Bid Documents, Pauwels 24 agrees to deliver the seven (7) Padmounted Transformers on a flatbed 25 truck for side unloading by forklift at ground level to the Soto Yard at 2800 Soto Avenue, Vernon, California. Pauwels shall notify the 26 City 48-hours prior to delivery to make arrangements for gates to be 27 opened. Delivery shall be scheduled for Monday through Thursday 28 -2- 1 between the hours of 7 a.m. and 3 p.m. 2 5. Warranties. Pauwels warrants title to the Padmounted 3 Transformers purchased hereunder and any part thereof to be free of 4 any claim or any security interest, lien or any encumbrance. Pauwels 5 also warrants that the Padmounted Transformers will be delivered new 6 and shall be free from defects. Pauwels shall provide, at a minimum, 7 a one (1) year labor and material warranty to begin upon acceptance of 8 the Padmounted Transformers by the City. All manufacturers' 9 warranties, any warranties typically provided by Pauwels and any other 10 warranties made applicable by law shall apply to the City's purchase 11 of the Padmounted Transformers. 12 6. Governing Law. The validity, interpretation and 13 performance of this Contract shall be controlled and construed under 14 the laws of the State of California. 15 7. Forum Selection. Any action brought relating to this 16 Contract shall be brought and held exclusively in a State Court in the 17 County of Los Angeles, California. 18 8. Notices. Notices to the parties, unless otherwise 19 requested in writing, shall be sent to: 20 City: THE CITY OF VERNON 21 ATTN: DOLORES FONSECA PURCHASING ASSISTANT 22 4305 SANTA FE AVENUE VERNON, CA 90058-0805 23 Pauwels: PAUWELS TRANSFORMERS, INC. 24 ATTN: DIANA KALLMBAH, ACCOUNT SPECIALIST ONE PAUWELS DRIVE 25 WASHINGTON, MO 63090 26 9. Risk of Loss. 27 Title and risk of loss or damage shall pass to the City and 28 delivery shall be deemed to be complete upon delivery FOB jobsite or -3- 3 14:47 FAX 636 239 9398 PALTWELS TRANS. Ca 002 1 2 3 4 5 6 7 8 9 10 11 upon moving into storage at the City's request, whichever occurs first. 10. Attorneys' Fees. In the event that it becomes necessary for either party to this Agreement to enforce any of the provisions of this Agreement, the parties agree that a court of competent jurisdiction may determine and fix reasonable attorney's fees to be paid to the successful, litigant. IN WITNESS WHEREOF, the parties have caused this Agreement to be executed by and through their authorized officers on 'the date, month and year first written above. 12 13 14 ATTEST: 15 16 17 18 19 20 21 22 23 24 25 26 27 28 HRUCE V. MALRENHORST, City Clerk APPROVED AS TO FORM: CITY OF VERNON By: LEONIS C. MALBURG, Mayor ERIC T. FRESCH, Acting City Attorney PAUWELS TRANSFORMERS, INC. By: Title: VI011� (D�_6t)�i'cS�L � By: Title: � A} , �{-1 IMF � Nth a L nFEiC.E-t2 -4- �I EXHIBIT OR I (7�11VAL REQUEST FOR QUOTATIONS CITY OF VERNON, CALIFORNIA NOT A PURCHASE ORDER PURCHASING DEPARTMENT DIRECT ALL INQUIRIES TO: CITY HALL CITY PURCHASING AGENT TELEPHONE (323) sss-se» 4305 Santa Fe Ave. - Vernon, California 90058 TO: PAUWELS TRANSFORMERS c/o Bernie Schweigert ` Pacific Utihities Supply Co., -2475- €stand Way Pleasant Hill, CA 94523 Please quote hereon the lowest net price you can furnish the articles or services specified below. Quote on each item separately. Bidder may qualify quotations as "all or none" by stating so on body of form. City reserves the right to accept or reject quotations received on any or all items. In order to maintain their name on City's Bidder File. Vendor should return this form whether a Drice is Quoted or not. kl,, QUANTITY DESCRIPTION NET UNIT PRICE TOTAL Padmount Transformers as per attached specification No. TR2-2003, dated September 15, 2003. KVA PRIMARY VOLTAGE KV SECONDARY VOLTAGE 3 500 7.2 277/480 73"__00 nt3 a I-1 00 2 750 7.2 277/480 9a3'3_C 1844-7 co 01) 1 150 16.34 120/208 3 300 16.34 277/480 1 500 16.34 277/480 3 750 16.34 277/480 q 14 OD _9761_778 (Z — 3 1000 16.34 277/480 lo548 GD jj(,ogq 00 2 2500 16.34 277/480 M313 (Z (Z 1 3750 16.34 277/480�CL'3� Deliver on flatbed truck for side unloading by forklift at ground level. Please notify RMI-US at (323) 589-9498 (48) hours deliver prior to have an p y. If you y questions, please contact Jose Lugo at (323) 583-8811, ext. 276. �- - — ------------PLEASE NOTE ---------- Bid number must be indicated on the outside of the envelope; otherwise, bid will not be accepted. IF INSUFFICIENT SPACE PROVIDED ABOVE FOR PROPOSAL, ATTACH RIDER OR SUPPLEMENT. CASH DISCOUNTS QUOTED FOR PERIODS OF LESS THAN 30 DAYS WILL NOT BE CONSIDERED WHEN ORDER IS AWARDED. BIDS RECEIVED IN RESPONSE TO THIS REQUEST FOR QUOTATION WILL BE OPENED IN CITY PURCHASING AGENT'S OFFICE ON THE DAY OF 20 AT NOTE: Quote prices exclusive of Sales Tax and Excise Taxes. A. Indicate Sales Tax in this space $...... N(A.................................................... B. Indicate Excise Tax in this space $... N)A.......................................... B. Above quotations subject to Cash Discount of ... N.1A.....................................%, 17.0.13-1).�V4.11.N,.0.19 ............. C. To be delivered to CITY OF VERNON at... a.-.IQ....Wrw...0 ..................................................................................................................... We (1) agree to furnish above in .1...?%..........days from receipt of purchase order at prices specified. FOR..... 5.....T.. I. .. 0j?Y p...5.................................... /rah (�nR Name DATE..... Ql-s�lt�� ............................ SIGN HERE......... ... UY)..................................................... MAIL TO PURCHASING DEPT. 12M u::# o 1::� ZLO�wcre—�'§J ILI I �r11111irl r 0 so k N. Quotation Number: P102011 Customer: CITY OF VERNON PURCHASING DEPT 4305 SANTA FE AVENUE VERNON, CA 90058 Attention: PURCHASING DEP Fax: 323-826-1425 Reference: QUOTATION NO 1429 Date: 10/31/2003 Cust. Code: VERN01 Region: 0400 We are pleased to present our quotation for three phase transformers with the accessories according to the attached bill of material(s) General Conditions: Prices: Firm for the duration of the contract. Validity: 30 days from the date of quotation. Taxes: Federal, state, local or any other taxes are excluded. Freight: Prepaid and Allowed, F.O.B. Destination Payment: 30 Days Net Payment Terms Warranty: Standard, 12 months from the date of installation, but not to exceed 18 months from the date of delivery. Any design dimensions, unless otherwise specified, are for indication only, and are not binding. This quotation is subject to Pauwels' Terms and Conditions of Sale, which are available upon request. Any deviation from the attached bill of material(s), before or after receipt of order, may affect price and delivery. The quoted ship weeks will go into effect after all outstanding technical matters have been resolved. Ship weeks are based on plant loading at time of quotation. Please verify ship weeks when placing an order. Please reference our quotation number on all purchase orders and correspondence. We will be pleased to provide you with any additional information that is required. Thank you for your inquiry, and we look forward to working with you in the future. Sincerely, PAUWELS TRANSFORMERS, INC. Diana Kallmbah Account Specialist Utility Sales (636) 239-9300 x345 cc: PACIFIC UTIL Marc Schillebeeckx Vice President Sales & Marketing Utility / Industrial Sales (636) 239-9300 x349 Quotation Number: P102011 Customer: CITY OF VERNON PURCHASING DEPT 4305 SANTA FE AVENUE VERNON, CA 90058 Attention: PURCHASING DEP Fax: 323-826-1425 Quotation Comments: TEST REPORTS ARE SENT AT TIME OF INVOICING. Date: 10/31/2003 Cust. Code: VERN01 Region: 0400 BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 01 Customer Line No.: Quantity: 3 Unit Price: $7,739.00 Extended Price: $23,217.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 500 kVA Model #: ZA050072E480007 Mineral Oil Immersed Cooling Class: OA Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 7200 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 75 kV Secondary BIL Rating: 30 kV High Voltage Taps: B Taps - Two 2.5% Taps below Nominal and Two 2.5% Taps above Nominal No Load Loss: 543 Watts Load Loss: 3302 Watts Total Loss: 3845 Watts Impedance: 4.17 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/ 8 Hole Aluminum H Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C14), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3543080M51M) Accessories: Pressure Relief Valve Qualitrol 202-030-01, Drain plug Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint, Coal Tar Under Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PTINC on 10/31/2003 BILL OF MATERIAL •1 ; w ; � air r Date: 10/31/2003 Quotation Number: P 102011 Item Number: 02 Customer Line No.: Quantity: 2 Unit Price: $9,238.00 Extended Price: $18,476.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 750 kVA Model #: ZA075072E480010 Mineral Oil Immersed Cooling Class: OA Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 7200 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 75 kV Secondary BIL Rating: 30 kV High Voltage Taps: B Taps - Two 2.5% Taps below Nominal and Two 2.5% Taps above Nominal No Load Loss: 665 Watts Load Loss: 5316 Watts Total Loss: 5981 Watts Impedance: 5.75 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/12 Hole Brass 7 Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C16), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3543200M51M) Accessories: Pressure Relief Valve Qualitrol 202-030-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PTINC on 10/31/2003 BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 03 Customer Line No.: Quantity: 1 Unit Price: $4,819.00 Extended Price: $4,819.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: Primary Voltage: Primary BIL Rating: High Voltage Taps: No Load Loss: 150 kVA Mineral Oil Immersed 16340 Delta volts 95 kV Model #: Cooling Class: Frequency: Avg. Winding Temp. Secondary Voltage: Secondary BIL Rating: S Taps - 15480/15910/16340/16770/17200 230 Watts Load Loss: 1354 Watts Impedance: 4.18 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions ZA015163E200001 OA 60 Hz 65 °C 208Y/120 volts 30 kV Total Loss: 1584 Watts Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Epoxy Bushings w/Thread-on 4 Hole Aluminum H Spades Protection: Dual Sensing Bayonet Fusing (353C10), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545080M51M) Accessories: Pressure Relief Valve Qualitro1202-037-01, Drain plug Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PTINC on 10/31/2003 BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 04 Customer Line No.: Quantity: 3 Unit Price: $5,942.00 Extended Price: $17,826.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: Primary Voltage: Primary BIL Rating: High Voltage Taps: No Load Loss: 300 kVA Mineral Oil Immersed 16340 Delta volts 95 kV Model #: Cooling Class: Frequency: Avg. Winding Temp. Secondary Voltage: Secondary BIL Rating: S Taps - 15480/15910/16340/16770/17200 375 Watts Load Loss: 2194 Watts Impedance• 4.05 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel RV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Epoxy Bushings w/Thread-on 4 Hole Aluminum H SDades ZA030136E480004 OA 60 Hz 65 °C 480Y/277 volts 30 kV Total Loss: 2569 Watts Protection: Dual Sensing Bayonet Fusing (353C10), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545080M51M) Accessories: Pressure Relief Valve Qualitrol 202-037-01, Drain plug Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PTINC on 10/31/2003 BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 05 Customer Line No.: Quantity: 1 Unit Price: $7,469.00 Extended Price: $7,469.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 500 kVA Model #: ZA050163E480005 Mineral Oil Immersed Cooling Class: OA Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 16340 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 95 kV Secondary BIL Rating: 30 kV High Voltage Taps: S Taps - 15480/15910/16340/16770/17200 No Load Loss: 526 Watts Load Loss: 3292 Watts Total Loss: 3818 Watts Impedance: 4.18 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/ 8 Hole Brass H Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C10), Plastic Dripshield (), Spare bayonet fuses (2 sets) PRCLF (3545080M51M) Accessories: Pressure Relief Valve Qualitrol 202-037-01, Drain plug Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PTINC on 10/31/2003 ---------- - BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 06 Customer Line No.: Quantity: 3 Unit Price: $9,326.00 Extended Price: $27,978.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: Primary Voltage: Primary BIL Rating; High Voltage Taps: No Load Loss: 750 kVA Mineral Oil Immersed 16340 Delta volts 95 kV Model #: Cooling Class: Frequency: Avg. Winding Temp. Secondary Voltage: Secondary BIL Rating: S Taps - 15480/15910/16340/16770/17200 671 Watts Load Loss: 4974 Watts Impedance: 5.75 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel RV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts ZA075163E480001 OA 60 Hz 65 °C 480Y/277 volts 30 kV Total Loss: 5645 Watts Secondary Terminations: Porcelain Bushings w/12 Hole Brass J Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C12), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545125m6lm) Accessories: Pressure Relief Valve Qualitrol 202-037-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by FMC on 10/31/2003 BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 07 Customer Line No.: Quantity: 3 Unit Price: $10,548.00 Extended Price: $31,644.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: Primary Voltage: Primary BIL Rating: High Voltage Taps: No Load Loss: 1000 kVA Mineral Oil Immersed 16340 Delta volts 95 kV Model #: Cooling Class: Frequency: Avg. Winding Temp. Secondary Voltage: Secondary BIL Rating: S Taps - 15480/15910/16340/16770/17200 830 Watts Load Loss: 6790 Watts Impedance: 5.75 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts ZA100163E480001 OA 60 Hz 65 °C 480Y/277 volts 30 kV Total Loss: 7620 Watts Secondary Terminations: Porcelain Bushings w/12 Hole Brass J Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C12), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545125m6lm) Accessories: Pressure Relief Valve Qualitro1202-037-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: T Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PnNC on 1051/2003 Tf "; — 16 s ki 0 BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P 102011 Item Number: 08 Customer Line No.: Quantity: 2 Unit Price: $19,313.00 Extended Price: $38,626.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 2500 kVA Model #: ZA250163E480011 Mineral Oil Immersed Cooling Class: OA Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 16340 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 95 kV Secondary BIL Rating: 30 kV High Voltage Taps: S Taps - 15480/15910/16340/16770/17200 No Load Loss: 1842 Watts Load Loss: 14966 Watts Total Loss: 16808 Watts Impedance: 5.75 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/14 Hole Brass J Spades, Spade Support Protection: None Accessories: Pressure Relief Valve Qualitro1202-037-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PrINC on 10/31/2003 BILL OF MATERIAL �.. y r w ,. Date: 10/31/2003 Quotation Number: P 102011 Item Number: 09 Customer Line No.: Quantity: 3 Unit Price: $6,591.00 Extended Price: $19,773.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: Primary Voltage: Primary BIL Rating High Voltage Taps: No Load Loss: 500 kVA Mineral Oil Immersed 7200 Delta volts Model #: Cooling Class: Frequency: Avg. Winding Temp. Secondary Voltage: ZA050072E480008 OA 60 Hz 65 °C 480Y/277 volts 75 kV Secondary BIL Rating: 30 kV B Taps - Two 2.5% Taps below Nominal and Two 2.5% Taps above Nominal 560 Watts Load Loss: 4696 Watts Total Loss: 5256 Watts Impedance: 4.13 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/ 8 Hole Aluminum H Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C12), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3543080M5M) Accessories: Pressure Relief Valve Qualitro1202-037-01, Drain plug Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PTINC on 10/31/2003 BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P 102011 Item Number: 10 Customer Line No.: Quantity: 2 Unit Price: $8,362.00 Extended Price: $16,724.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: Primary Voltage: Primary BIL Rating: High Voltage Taps: No Load Loss: 750 kVA Mineral Oil Immersed 7200 Delta volts 75 kV Model #: Cooling Class: Frequency: Avg. Winding Temp. Secondary Voltage: Secondary BIL Rating: ZA075072E480011 OA 60 Hz 65 °C 480Y/277 volts 30 kV B Taps - Two 2.5% Taps below Nominal and Two 2.5% Taps above Nominal 833 Watts Load Loss: 6102 Watts Total Loss: 6935 Watts Impedance: 5.75 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/12 Hole Brass J Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C16), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3543200M51M) Accessories: Pressure Relief Valve Qualitrol 202-037-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: _ GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PTINC on 10/31/2003 ar t 'za.{ .. IT, Id 104:9 BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 11 Customer Line No.: Quantity: 1 Unit Price: $4,430.00 Extended Price: $4,430.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: Primary Voltage: Primary BIL Rating: High Voltage Taps: No Load Loss: 150 kVA Mineral Oil Immersed 16340 Delta volts 95 kV Model #: Cooling Class: Frequency: Avg. Winding Temp. Secondary Voltage: Secondary BIL Rating: S Taps - 15480/15910/16340/16770/17200 221 Watts Load Loss: 2010 Watts Impedance: 4.19 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions ZA015163E200002 OA 60 Hz 65 °C 208Y/120 volts 30 kV Total Loss: 2231 Watts Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Epoxy Bushings w/Thread-on 4 Hole Aluminum H Spades Protection: Dual Sensing Bayonet Fusing (353C10), Plastic Dripshield (), Spare bayonet fuses (2 sets) PRCLF (3545080M51M) Accessories: Pressure Relief Valve Qualitrol 202-037-01, Drain plug Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PTINC on 10/31/2003 BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P 102011 Item Number: 12 Customer Line No.: Quantity: 3 Unit Price: $5,429.00 Extended Price: $16,287.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: Primary Voltage: Primary BIL Rating: High Voltage Taps: No Load Loss: 300 kVA Mineral Oil Immersed 16340 Delta volts 95 kV Model #: Cooling Class: Frequency: Avg. Winding Temp. Secondary Voltage: Secondary BIL Rating: S Taps - 15480/15910/16340/16770/17200 424 Watts Load Loss: 2756 Watts Impedance: 4.2 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel HV-LV Barrier ZA030163E480005 OA 60 Hz 65 °C 480Y/277 volts 30 kV Total Loss: 3180 Watts Bushings: Radial Feed ANSI Specific Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Epoxy Bushings w/Thread-on 4 Hole Aluminum H Spades Protection: Dual Sensing Bayonet Fusing (353C10), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545080M51M) Accessories: Pressure Relief Valve Qualitrol 202-037-01, Drain plug Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PTINC on 10/31/2003 ,t7-7 1:�IA BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P 102011 Item Number: 13 Customer Line No.: Quantity: 1 Unit Price: $6,546.00 Extended Price: $6,546.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: Primary Voltage: Primary BIL Rating: High Voltage Taps: No Load Loss: 500 kVA Mineral Oil Immersed 16340 Delta volts 95 kV Model #: Cooling Class: Frequency: Avg. Winding Temp. Secondary Voltage: Secondary BIL Rating: S Taps - 15480/15910/16340/16770/17200 573 Watts Load Loss: 4242 Watts Impedance: 4.07 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel HV-LV Barrier ZA050163E480006 OA 60 Hz 65 °C 480Y/277 volts 30 kV Total Loss: 4815 Watts Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/ 8 Hole Aluminum H Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C10), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545080M51M) Accessories: Pressure Relief Valve Qualitro1202-037-01, Drain plug Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PTINC on 10/31/2003 aw ,t r r ' .. BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 14 Customer Line No.: Quantity: 3 Unit Price: $8,180.00 Extended Price: $24,540.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: Primary Voltage: Primary BIL Rating: High Voltage Taps: No Load Loss: 750 kVA Mineral Oil Immersed 16340 Delta volts 95 kV Model #: Cooling Class: Frequency: Avg. Winding Temp. Secondary Voltage: Secondary BIL Rating: S Taps - 15480/15910/16340/16770/17200 845 Watts Load Loss: 5922 Watts Impedance• 5.75 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts ZA075163E480002 OA 60 Hz 65 °C 480Y/277 volts 30 kV Total Loss: 6767 Watts Secondary Terminations: Porcelain Bushings w/12 Hole Brass J Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C12), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545125m61m) Accessories: Pressure Relief Valve Qualitro1202-037-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by FMC on 10/31/2003 BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 15 Customer Line No.: Quantity: 3 Unit Price: $9,239.00 Extended Price: $27,717.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 1000 kVA Model #: ZA100163E480002 Mineral Oil Immersed Cooling Class: OA Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 16340 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 95 kV Secondary BIL Rating: 30 kV High Voltage Taps: S Taps - 15480/15910/16340/16770/17200 No Load Loss: 1024 Watts Load Loss: 8029 Watts Total Loss: 9053 Watts Impedance: 5.75 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/12 Hole Brass J Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C12), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545125m6lm) Accessories: Pressure Relief Valve Qualitrol 202-037-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PTINC on 10/31/2003 PAU�� BILL OF MATERIAL reE'.ER,;Y,S R BUSINESS Quotation 2 Quotation Number: P1020102011 PAUWELS TRANSFORMERS INC. Item Number: 16 Customer Line No.: Quantity: 2 Unit Price: $17,632.00 Extended Price: $35,264.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 2500 kVA Model #: ZA250163E480012 Mineral Oil Immersed Cooling Class: OA Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 16340 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 95 kV Secondary BIL Rating: 30 kV High Voltage Taps: S Taps - 15480/15910/16340/16770/17200 No Load Loss: 2234 Watts Load Loss: 16654 Watts Total Loss: 18888 Watts Impedance: 5.75 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/14 Hole Brass J Spades, Spade Support Protection: None Accessories: Pressure Relief Valve Qualitrol 202-037-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PTINC on 10/31/2003 Quotation Number: P102012 Customer: CITY OF VERNON PURCHASING DEPT 4305 SANTA FE AVENUE VERNON, CA 90058 Attention: PURCHASING DEP Fax: 323-826-1425 Reference: QUOTATION NO 1429 Date: 10/31/2003 Cust. Code: VERN01 Region: 0400 We are pleased to present our quotation for three phase transformers with the accessories according to the attached bill of material(s) General Conditions: Prices: Firm for the duration of the contract. Validity: 30 days from the date of quotation. Taxes: Federal, state, local or any other taxes are excluded. Freight: Prepaid and Allowed, F.O.B. Destination Payment: 30 Days Net Payment Terms Warranty: Standard, 12 months from the date of installation, but not to exceed 18 months from the date of delivery. Any design dimensions, unless otherwise specified, are for indication only, and are not binding. This quotation is subject to Pauwels' Terms and Conditions of Sale, which are available upon request. Any deviation from the attached bill of material(s), before or after receipt of order, may affect price and delivery. The quoted ship weeks will go into effect after all outstanding technical matters have been resolved. Ship weeks are based on plant loading at time of quotation. Please verify ship weeks when placing an order. Please reference our quotation number on all purchase orders and correspondence. We will be pleased to provide you with any additional information that is required. Thank you for your inquiry, and we look forward to working with you in the future. Sincerely, PAUWELS TRANSFORMERS, INC. '01 M, Z E ME �� Diana Kallmbah Marc Schillebeeckx Account Specialist Vice President Sales & Marketing Utility Sales Utility / Industrial Sales (636) 239-9300 x345 (636) 239-9300 x349 cc: PACIFIC UTIL 4 Quotation Number: P102012 Customer: CITY OF VERNON PURCHASING DEPT 4305 SANTA FE AVENUE VERNON, CA 90058 Attention: PURCHASING DEP Fax: 323-826-1425 Quotation Comments: TEST REPORTS ARE SENT AT TIME OF INVOICING. Date: 10/31/2003 Cust. Code: VERN01 Region: 0400 BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102012 Item Number: Ol Customer Line No.: Quantity: 1 Unit Price: $26,031.00 Extended Price: $26,031.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 3750 kVA Model #: ZA375163E480005 Mineral Oil Immersed Cooling Class: OA Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 16340 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 95 kV Secondary BIL Rating: 30 kV High Voltage Taps: S Taps - 15480/15910/16340/16770/17200 No Load Loss: 2513 Watts Load Loss: 26229 Watts Total Loss: 28742 Watts Impedance: 6 Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/16 Hole Brass J Spades, Spade Support Protection: None Accessories: Pressure Relief Valve Qualitro1202-037-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Under Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise svecified by the customer. Shipment: SHIPMENT IN 10 TO 12 WEEKS AFTER RECEIPT OF ORDER Printed by PTINC on 10/31/2003 BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P 102012 Item Number: 02 Customer Line No.: Quantity: 1 Unit Price: $24,114.00 Extended Price: $24,114.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 3750 kVA Model #: ZA375163E480006 Mineral Oil Immersed Cooling Class: OA Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 16340 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 95 kV Secondary BIL Rating: 30 kV High Voltage Taps: S Taps - 15480/15910/16340/16770/17200 No Load Loss: 3089 Watts Load Loss: 27862 Watts Total Loss: 30951 Watts Impedance: 6 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/16 Hole Brass J Spades, Spade Support Protection: None Accessories: Pressure Relief Valve Qualitrol 202-037-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Under Powder, Standards: Quoted in compliance with the latest anDlicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 10 TO 12 WEEKS AFTER RECEIPT OF ORDER Printed by PTINC on 10/31/2003 r 1 L's i /,1,,D G TRANSFORMER OUTLINE MATERIALS LIST FOR DRAWING #P102011 DATED OCTOBER 28, 2003 1 High Voltage Bushing Wells (Cooper #2638372C01) And Inserts (Cooper #LBI215BP) 2 Low Voltage Epoxy Bushings With 5/8" Copper Studs (CM #701315-51) And 4-Hole Aluminum "IT'Spades (150 kVA And 300 kVA) Low Voltage Epoxy Bushings With 1" Copper Studs (CM #701334-52) And 8-Hole Supported Aluminum "H" Spades (500 kVA) Low Voltage Epoxy Bushings With 1" Copper Studs (CM #701334-52) And 12-Hole Supported Brass "J" Spades (750 kVA) Low Voltage Porcelain Bushings With 1 1/a" Copper Studs And Integral 12-Hole Supported Brass "J" Spades (Warco #40A8008-1C), (1000 kVA) Low Voltage Porcelain Bushings With 2" Copper Studs And Integral 14-Hole Supported Brass "J" Spades (Warco #40A08019-5), (2500 kVA) Low Voltage Porcelain Bushings With 2 1/2" Copper Studs And Integral 16-Hole Supported Brass "J" Spades (Warco #45A03096), (3750 kVA) 3 ESNA #151-PS Parking Stands 4 1/a" NPT 10 PSI 50 SCFM Pressure Relief Valve (Qualitrol #202-030-01) 5 2" Square Liquid Level Gauge With Weld Flange (Qualitrol #020-037-01) 6 1/2" NPT 4" Dial 120 Degree "C" Liquid Temperature Gauge (Qualitrol #150-101-01 7 Provision For 1" NPT Oil Fill Valve With Plug (UB #175T) 8 1" NPT Oil Drain Valve And Sampler (UB #175TSS) 9 Stainless Steel Nameplate With An Additional Nameplate On The Inside Of The Low Voltae Door 10 One -Hole Ground Pads Without Lugs (BB #TTC2P), (150 — 500 kVA) Two -Hole Ground Pads Without Lugs (BB #TTC2P), (750 - 3750 kVA) 11 Low Voltage Ground Strap 12 Provision For Lifting 13 Padlock Facility And Penta-Head Door Bolt 14 Low Voltage Door Handle 15 Removable Lower Front Sill 16 Base Arrangement For Rolling In Two Directions 17 Transformer Tank 18 Low Voltage Compartment Door 19 High Voltage Compartment Door 20 Raised Air Compartment Top For Ba -O-Net Fuse Replacement 21 lacking Provisions 22 No Cooling Fins (150 kVA And 300 kVA Low T.O.C. Design) Back Cooling Fins (300 kVA 5% T.O.C. Window Design And 500 —1000 kVA) Back And Side Cooling Fins (2500 — 3750 kVA) 23 Tap Changer `B" Taps +5% +2.5% -2.5% -5%; ASP #01.20.315 (150 — 300 kVA) ASP #01.208.25 (500 —1000 kVA Except For 750 kVA 7200V) ASP #01.21.825 (750 kVA 7200V And 2500 kVA) Cooper #2237471C01 (3750 kVA) 24 No "HOXO" Grounding Switch (Warco #50A00365) No "HOXO" Removable Link 25 Bay-O-Net Current / Fault Sensing Fuses In Fuse Holders With 2-Sets Of Snare Fuses: N V w Z spy LL1 IL no a(n T) z Q �'W J .: W Ln d to r` O Ln O M M d M O r` r M C0 cD It rMOMd'lnd'NNNNNNNr(V 00 O 00 Ln r` M N Opr d w N M q CD N d Ln N M g 0 w T LO r T M r 0 0 r 0 N r In 0 0 M 0 r N O M o T O N Ln r M 1- N In 0 o r 't O d' N N r N r T T N N co Ln r N r r r N N M 0 N N N NNNN Ln O N N N N N N N to 0 CD (D (D (D M w (O N Ln (O wO CO CO (fl(PN liuiLnd'd"d'd'd'd''tL 0 OOOOOOONr`OOOOOoONN Ln Ln Ln Ln Ln Ln I Ln r M Ln Ln 1 [) Ln Ln 0 Ln r CO M CM C'7 M 60 c M u') 6 m m M M M 6 6 Ln to 0 Ln Ln O O O Ln O O LA O 0 O O Ln Ln O Ln O r` N Ln O O r` O O N O N O O r` N O N in O M o Ln O N T 00 M N M CO r` N M N r` cO O'tIt DCDr-r 'tcoMd'd*wLoloul O Ln Ln O O Ln O O O Ln 0 0 0 0 O 0 O o r N LO 0 r` O O 0 f� Ln N N I- 0 N Ln T- M CD 0 r CO to M r 0)" 0) 0) M CM q CO d Ln M 'd' It Ln Ln Ln CD m Ln co co co Ln Ln W 00 0 O O O 00 O O O O 000000 Im" Ln M Ln Ln LC) Ln In 0 Ln U) Ln C� (O CO 6 c0 6 cD (O CD C0 C6 CD CO CO (0 (O t0 N N N N N N N N N N N N N N N N N (0 CO (D CO O Cfl CO O CO w w C0 cD CD w c0 M 00 Ln OO M M M M r 00 00 Ln 00 00 00 00 MO(0 C000CD C0 M r` 00 (0 CD CD (0 CO (D (D r` to Ln l� N Ln Ln f� w N Ln o 0 0 0 O ' 'OOr1�N00rI�NMNCRr- L0"(DOLnN CV 00 Ln CA N aD .- r` O GA d LA r` 0) it 0 00 0 'td MM4d'LnMrM'tMMM g0Mr N N N N N N N N N N N N N N N N N N •:. r T r T I r T r Tr 1— Ty r 77 T r r y . V 4d' 't LO M 06 V . V .7 V '1 4 1 '1 '1 Ln 00 Ln O O Ln O O O O Ln O O O Ln O O O O r` O Ln Ln r- 0 0 0 0 N O Ln to N O O O O 6 N T T 6N CV 00 6 N-: r 6 N N 4 OD cD r` cD coocDr` r` r` r` co r` m m co r- r` r` r` MOMMMOOOOMOMMMoOOO T M r r- r co (M M co +- M r r r co co M M r CO N r r Cp CO 0 (0 r (0 N r r C0 (0 co (D "rNMCM't"t"tdtCO"tNV)co t etd - r N r r I r N N N N r N r` r` r N N N N N 'd' N N N �t 't 't Iq N N N N d' 't I 't _ ' 00 00 O M 00 00 00 00 00 00 00 C0 00 00 M 00 00 Op 00000000 Ln O O O O O O O Ln Ln Ln 0 Ln Ln Ln Ln Ln N N Ln 0 O Ln Ln Ln O N N cD co L1j co CO (O (0 (O r` CD CO to (D c0 (0 O co r` Nrz0r`r`r,r`NNrzN0Nr`r,r`rzN N Nr`r-NNr`r` NNrNNNNNcgCMCM r`NNNNN NNNNNN N }}}}:}}}}}}:}}}}}}}} 0 0 00 O O O O O O O O M O O O O O O M 00 O 00 00 00 00 00 00 00 00 O 00 00 00 00 00 M Ltd cm. 'It. d d'�hd 111. Ltd N'td ��d''IT O O O O O O O O OO Ln Ln O O Ln O 100000000 Ln O Ln InO CDLn O O Ln N r M Ln r` 00 N T- M Ln r Or LO M COM N CO N 00 M O r N CO d Ln O N 00 O O 0 0 0 0 0 0 0 r r r r r r T r r SPECIFICATION NO. TR2-2003 PADMOUNT TRANSFORMER CITY OF VERNON LIGHT AND POWER SEPTEMBER 15, 2003 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 1.0 SCOPE Supplier shall furnish all work for providing three-phase, deadfront, radial, self cooled, padmounted transformers for use on the City of Vernon's underground distribution system. The transformer sizes that the City requires are listed in Attachment A. This list does not preclude the possibility of ordering voltage and KVA ratings not listed under this specification. 2.0 APPLICABLE STANDARDS A. The transformers shall conform to the applicable sections of the following standards to the extent referenced in this Specification, and as amended to the date of this Specification which, by reference, are included as part of this Specification. 1. C57.12.00 IEEE Standard General Requirements for Liquid - Immersed Distribution, Power, and Regulating Transformers. 2. C57.12.26 Requirements for Padmounted Compartmental - Type, Self Cooled, Three -Phase Distribution Transformers for Use with Separable Insulated High Voltage Connectors, High Voltage 34500GrdY/19920 Volts and Below, 2500 kVA and Smaller. 3. C57.12.28 Padmounted Equipment —Enclosure Integrity. 4. C57.12.90 IEEE Standard Test Code for Liquid -Immersed Distribution, Power, and Regulating Transformers and IEEE Guide for Short -Circuit Testing of Distribution and Power Transformers. 5. C57.91 Guide for Loading Mineral -Oil -Immersed Overhead and Padmounted Transformers Rated 500 kVA and Less with 65°C or 55°C Average Winding Rise. 6. C57.92 Guide for Loading Mineral -Oil -Immersed Power Transformers Up to and including 100 MVA with 650C or 550C Average Winding Rise. 7. C57.106 IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment. B. In the event of conflict between the codes and standards and this Specification, Supplier shall notify City of Vernon Light and Power Department and secure a written clarification before proceeding with the work. 3of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 3.0 SERVICE CONDITIONS 3. 1. Environment A. The transformers shall perform in accordance with all provisions of the Specification while subject to the service conditions specified in ANSI/IEEE C57.12.00. B. The transformer shall be suitable for 30 years of use -on the City of Vernon's electric system when installed in accordance with the service conditions set forth in ANSI/IEEE C57.12.00-1987, Section 4.0, in its entirety. 3. 2. Seismic and Impact Loading A. Before and during installation, the transformers shall withstand, without damage, rough handling such as bouncing on a truck when filled with insulating medium and impacting against or upon rigid structures at speeds up to five feet per second, and being lifted by two bosses or lifting second, and being lifted by two bosses or lifting bolts at any angle. Following these conditions, the transformers shall be capable to being energized without a pre- operational test. B. After installation and during the 30-year life of transformer, transformer will be subject to occasional earthquake motions (0.2g horizontal and 0.13g vertical) along with significant vibrations from traffic and from adjacent equipment. 3.3 Pre -installation Inspection The City of Vernon will, at its discretion, provide a pre -installation inspection of each transformer. 3.4 Operating Dutv For its 30-year life, each transformer shall be suitable for operation under short circuit conditions as stated in ANSI/IEEE C57.12.00-1987, Section 7.1. 4of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 3.5 Shipping A. All transformers shall be shipped to the City of Vernon, Soto Yard located at 2800 Soto Avenue, Vernon, CA 90058. Supplier's price shall be F.O.B. Soto Yard. B. Transformers will be delivered on a flatbed truck for side unloading by forklift at ground level. C. Delivery will be scheduled Monday through Thursday 7:00 a.m. to 3:00 P.m. Supplier shall provide City with 48 hours notice prior to delivery. 4.0 RATINGS 4.1 Sizes The transformers shall be sized as shown in Attachment A. 4.2 High Voltage Ratings Transformers shall be 60 Hz with BIL ratings as shown in the table below. Transformer and Connector High oltaa Ratings and Electrical Characteristics Transformer Electrical Characteristics of the Completely Assembled High -Voltage Connectors'' High -Voltage Rating 2' Phase -to -Ground /Phase -to- Phase (kV) BIL (kV) 60-Hz dry one minute withstand (kV) High -Voltage Ratings (volts) Minimum BIL3. (kV) Single High -Voltage 7200 16340 75 95 8.3/14.4 8.3/14.4 95 95 34 34 Series -Multiple High - Voltage 7200 x 16430 75 x 95 8.3/14.4 95 34 For complete connector rating, see ANSI/IEEE 386. 2 Transformers are suitable for connectors with phase -to -ground or phase-to-ground/phase-to-phase high -voltage ratings as listed. 3 Arrester coordination may require higher BIL on multiple connection than indicated to achieve a minimum protection level of 20%. 5of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 4.3 Low Voltage Rating The secondary voltage shall be one of the following. The basic insulation level (BIL) of the secondary voltage shall be 30 kV: 480Y/277 208Y/120 4.4 Configuration All transformers shall be Delta -Wye configured with low voltage neutral having a fully insulated X. bushing with a removable ground strap. 4.5. Impedances Transformer impedance shall not be less than those shown in the table below. All transformer testing to determine transformer impedance shall be based on the base kVA rating of the transformers at the 55 degree or 65 degree temperature rise. The transformer impedances shall be shown on the transformer nameplate. Minimum Transformer Impedance KVA %Z 300-500 4.0 750-2500 5.75 3750 6.00 5.0 CONSTRUCTION FEATURES 5.1 Coil and Core Construction A. The transformer core shall be of high efficiency rectangular wound. core designed in five -leg or triplex configurations. The core shall be made from one of two processes: single -turn laminations of high quality, grain oriented silicon core steel or amorphous core (Le metallic glasses metal). B. The transformer coils shall be designed to maintain their nameplate KVA rating throughout the normal temperature range of operation which shall be 650C (80°C hot spot). All materials used shall be of the 65°C, 800C hot spot class. All materials shall be thoroughly tested for compatibility with all transformer components before being assembled. The primary coil shall 6of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 5.2 5.3 be manufactured from heavy varnish or paper insulated aluminum or copper wire. The secondary coil shall be manufactured from full width aluminum strip whose edges are finished to prevent burrs and insulated with epoxy -diamond paper between layers of the conductor. Insulating Fluid A. The transformer insulating fluid shall be standard electrical grade mineral insulating oil. The insulating oil shall be tested and degassed to assure a chemically inert oil. The padmount transformers shall be furnished with oil' which meets the requirements specified in ASTM Standard D 3487 for mineral insulating oil, except that the DBPC content (% by weight) shall not be less than 0.15. The insulating oil in the equipment shall conform with ANSI C57.106. B. All transformer oil shall be tested for polychlorinated biphenyl's (PCBs) per ASTM D4059 and certified as having no detectable levels of PCB. Taps and Changers A. The transformers shall be furnished with full capacity high -voltage taps. The tap changer shall be clearly labeled to reflect that the transformer must be de -energized before operating the tap changer as required in Section 3.3 of ANSI C57.12.26. Padlocking provisions are available for lever or hotstick operable handles. Tap changer operating mechanisms shall be permanently identified to show "De -energized Operation Only". Decals and stencils are not acceptable. The unit shall have one of the following tap configurations: Two - 2%2% taps above and below rated voltage such as the following: VOLTAGE FULL CAPACITY TAPS 16,340 17,200/16,770/15,910/15,480 7,200 7,560/7,380/7,020/6,840 B. The tap changer position indicating nameplate shall have numerals or letters that are clearly legible and of permanent quality. Decals and stencils are not acceptable. 7of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 5.4 5.5 5.6, 5.7 gauges A. All transformers shall have a dial -type, magnetic, oil level gauge to provide a positive means of determining the required oil height. The preferred location of the gauge is above the switch handles, to ensure the switch remains under oil. B. All transformers shall have a dial -type, magnetic, temperature gauge to provide a positive means of determining the transformer temperature. The required location of the gauge is in the low voltage compartment above the bushings. Drain and Replacement Provisions Insulating medium drain and replacement provisions shall be furnished as specified in ANSI C57.12.26. Tanks and Terminal Compartment A. The transformer tanks, and all external appurtenances, shall be in accordance with ANSI C57.12.26. The overall dimensions and various appurtenances locations shall be found on each transformer per Attachments C and D. B. Transformers shall have bolted covers for all size transformers. C. The compartment depth shall be minimum in accordance with figure 7 of C57.12.26. A deeper compartment shall be provided for extended secondary bushings. The tank shall be of sufficient strength to withstand a pressure of 7 psig without permanent distortion. The following pressure relief devices are approved: 1. Qualitrol Model No. 202-030-001 2. Qualitrol Model No. 202-032-001. Terminations Transformer bushings shall accommodate cable terminations in accordance with ANSI/IEEE 386, but shall be modified to provide the height requirements of these specifications as shown in Attachments C and D. 8of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 5.8 Nameplates A stainless steel nameplate shall be attached with non -corrosive hardware to the inside of the low voltage compartment door. The nameplate shall not be installed on the rear of the low voltage compartment area. Diagrams and numbers shall be of the size and quality such that they can be read from outside the compartment. In addition to the nameplate requirements shown in ANSI/IEE C57.12.00-1987, Section 5.12, the total weight, including oil, shall be indicated. 5.9 Coating A. Each transformer and terminal enclosure combination shall be painted a forest green color such as Dulux Bell Telephone Green No. 183-Y-546 (Munsell 7.5GY2.95/2.1) or City of Vernon -approved equivalent. The primary and finishing coats shall have a combined minimum dry -film thickness of three mils. Manufacturer shall furnish 1/4 pint of touch up paint for each transformer. B; The underside of each transformer shall be coated with an asphaltic .material or with City of Vernon -approved paint system. An epoxy coat which meets ANSI C57.12.28 is acceptable. 6.0 Loadbreak Switches 6.1 'Type A. Each transformer shall have a three-phase, self-contained, oil immersed, high voltage, loadbreak gang -operated sectionalizing switch. The switches shall be inside the transformer tank and be so located that current interruption occurs under oil. The loadbreak switches shall provide circuit connections as shown in Attachments C. and D. Operation of the switch shall be clockwise to close. B. The operating handle shall be located in the high voltage compartment and be suitable for hot stick operation. The position of the switch, whether open or closed, shall be clearly indicated. The handle shall be located in such a manner as to be identifiable with the associated circuit -transformer. Stencils or decals to indicate switch positions are not acceptable. 9of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 6.2 Interlocks The switch shall have an interlock which will prevent removal of fuses when the switch is in the closed position and also prevent the inserting of fuses when the switch is in the closed position. 6.3 Ratings The switches shall have the following ratings when completely assembled and installed in the transformers. A. Minimum Voltage Rating: 17,000 volts. B. Loadbreak Capability: 200 rms amperes at 17,000 volts and 0.6 power factor. C. Short -time current Rating: 10,000 rms symmetrical amperes for 15 cycles. D. Closing and Holding Current Rating: 10,000 rms symmetrical amperes for 15 cycles. E. There shall be no arcing time after the switch blades have traveled from the closed position to the fully opened position. 7.0 OVERCURRENT PROTECTION 7.1 High Voltage Protection A. Transformers shall be protected against overcurrent by means of a City of Vernon -approved externally replaceable fuses in the primary circuit. The fuses shall be suitable for hot stick operation and shall have a minimum of 50,000 rms symmetrical ampere interrupting rating. The fuses shall have City of Vernon -approved safety devices which prevent insertion directly into a fault. B. The fuses shall be a Bay-O-Net type oil immersed fuses in series with oil immersed current limiter type RTE ELSP current limiting backup fuse. The fuses shall have a safety device which prevent insertion directly into a fault. 10 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS C. The correct size of Bay-O-Net fuse for replacement shall be indicated by stencil or decal above the Bay-O-Net fuse as follows: "Caution: Use only RTE Bay-O-Net Type 353C "(10, 12, etc.)" Amps" (25, 40, etc.) D. The following table lists the appropriate fuse sizes: Transformer Ratings KV KVA KVRatin g FLA High Voltage Fuses4 BAYONET ELSP MINIMUM 16.34 300 15.5 11 4000353C10 354508OM51 M 4.00 500 15.5 18 4000353C10 354508OM51 M 4.00 750 15.5 26 4000353C12 3545125M61 M 5.75 1000 15.5 35 4000353C12 3545125M61 M 5.75 1500 15.5 53 4000353C16 354515OM51 MS 5.75 2000 15.5 70 4000353C16 354515OM51 MS 5.75 2500 15.5 88 NONE NONE 5.75 3750 15.5 132 NONE NONE 6.00 7.2 300 8.3 24 4000353C12 3543125M61 M 4.00 500 8.3 40 4000353C14 354308OM51 MS 4.00 750 8.3 60 4000353C16 354320OM51 M 5.75 1000 8.3 80 4000353C17 3543175M51 MS 5.75 1500 8.3 120 NONE NONE 5.75 E. A minimum of 6 spare Bay-O-Net fuses shall be provided with each transformer order. For instance, if we order one 7.2 KV type 300 KVA transformer we require 6 spare fuses. If we order two such transformers, we require 12 spare fuses. 7.2 Low Voltage Protection Low voltage overcurrent protection is not required. 4 Cooper (Type Bay-O-Net and Current Limiting ELSP) 5 Two parallel fuses per phase 11 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 8.0 BUSHINGS, BUSHING WELLS AND PARKING STANDS 8.1 Low Voltage Bushings A. Transformers shall have bushings which conform to ANSI Standard C57.12.26. On "Wye" connected transformers, the neutral shall be connected to a fully insulated bushing. An additional tank ground pad with removable neutral bushing ground strap shall be provided and suitably sized for the short circuit current rating of the transformer. B. External spade terminals shall have a heavy tin coating process. If the terminal extension is not an integral part of the bushing, it shall be securely pinned to the stud. C. External spade terminals with six holes and more shall be furnished with additional support straps, designed by the manufacturers, at the end farthest from the tank wall without interfering with the use of any of the holes. Each extension pad shall be fully rated for the maximum ampacity of the transformer. Refer to the table below for the number of terminal holes. KVA Ratings Low -Voltage Ratings (Volts) Number of 9/16" hole cable positions 75-300 ALL 4-6 500 ALL 8 750-1500 ALL 12 2000-2500 ALL 14 3750 ALL 16 8.2 High Voltage Bushing Wells Transformers shall be provided with three City of Vernon -approved, 17 kV high voltage bushing wells rated 95 kV BIL, marked and located as shown in Attachments C and D. 8.3 Parking Stands Transformers shall be equipped with non -load break parking stands, ESNA No. 151-PS or City of Vernon -approved equivalent. They shall be located as shown in Attachments C and D and in accordance with ANSI Standard C57.12.26. 12 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 9.0 IDENTIFICATION 9.1 Stencils & MSDS A. All bushings shall be identified by yellow paint stencils, a minimum of one inch high, on the tank wall adjacent to the bushings. See Attachments, C and D. B. A removable identification tag or sticker which shall be legible at time of receipt shall be attached to the exterior of the terminal compartment. The tag or sticker shall indicate the name of the manufacturer, serial number, kVA and voltage ratings. C. In addition to the nameplate. information called for in ANSI C57.12.00, the nameplate shall identify each winding as to whether it is made of copper or aluminum. D. The vendor shall be required to provide all applicable Material Safety Data Sheets with all transformer orders. 10.0 ADDITIONAL REQUIREMENTS 10.1 Barriers A barrier shall separate the high -voltage section from the low voltage section in the terminal compartment. Barrier shall be of sufficient strength to prevent deformation which may reduce the required clearances to various components. 10.2 Conduit Entrance When specifically requested in the transformer table below, a 2 %2 inch conduit entrance hole, with a cover which is removable only from the inside, shall be provided in the center of the low voltage sill. 13 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 10.3 Terminal Arrangements Terminal arrangements shall be as shown in Attachments C and D. 10.4 Access to Terminal and Switching Compartments A. Transformers shall be provided with hinged doors for access to the terminal and switching compartments. Access to the high voltage portion of the terminal and switching compartment shall be possible only after access has been gained to the low voltage. B. The low voltage compartment door shall be further secured by means of a captive and recessed V2 inch pentahead bolt. A blind bolt hole shall be provided. Bolts shall be corrosion resistant and the design shall minimize the possibility of a misalignment and cross -threading. Design of the bolting, padlocking and three-point latching provisions shall be coordinated such that, only after the padlock and bolt have been removed, shall it be possible to open the low voltage compartment door. 11.0 TESTS 11.1 General A. Transformer tests shall be performed as specified in ANSI Standard C57.12.00. These test reports shall be provided to the City prior to shipping. The City will not receive any transformers without the required test reports. B. Units shall comply with routine test requirements of ANSI and certified test reports shall be furnished. The vendor shall provide with returned bids all applicable documentation of compliance with ANSI design tests. C. The following data shall be submitted with each transformer order: a. Guaranteed maximum no load (excitation) loss at rated voltage and 110% voltage in Watts. - b. Guaranteed maximum load loss in Watts at rated voltage and 110% voltage. c. Guaranteed maximum total loss in Watts at rated voltage and 110% voltage. 14 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TP.ANSFORMER TECHNICAL REQUIREMENTS d. Exciting Current in percent at rated voltage and 110% rated voltage. e. Percent impedance on base voltage and at the maximum temperature rise. If the transformer is a 55/65 degree Celsius transformer rise, the percent impedance shall be at 65 degree Celsius. f. Efficiencies shall be provided at loading levels of 100%, 75%, 50%, and 25%. g. Regulation at rated load @ 80% and 100% Power Factor. h. Two sets of outline drawings showing dimensions, weight, gallons of oil, gauge of steel in tank walls, cover, bottom, and cooling radiators and description of accessories. After order is awarded, the vendor shall submit FINAL drawings. 12.0 OPERATING PERFORMANCE 12.1 General The Apparatus shall perform in accordance with the conditions set forth in this Specification. 13.0 BID EVALUATION 13.1' Total Ownership Cost Purchase of transformers shall be evaluated by lowest total ownership cost. The formula to evaluate Total Owning Cost (TOC): TOC = C + $4.53/W (PNL in Watts) + $1.1/W (PLL in Watts) Where TOC is the total ownership cost in dollars, C is the initial cost in dollars, PNL is the guaranteed maximum no-load loss in watts, and PLL is the guaranteed maximum load loss in watts For the determination of the award for the transformer order(s), City will consider all bids within 5% of the lowest Present Value Cost of Transformer to be economically equivalent. The City of Vernon realizes it is impossible to accurately predict economic conditions over the evaluation period of 30 years. 15 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 13.2 Delivery A delivery date of 16 weeks ARO or less is required. Failure to quote a delivery schedule within this period may disqualify the bid. 14.0 DOCUMENTATION 14.1 For Bid Evaluation Bidders shall furnish the following in their bid proposals: 1. Transformer unit price, F.O. B. Soto Yard. 2. Guaranteed maximum no-load loss at rated voltage in watts. 3. Guaranteed maximum load loss in watts at rated voltage and kVA. 4. Percent impedance on rated voltage tap. 5. Two sets of dimension and outline drawings. 14.2 For Delivery Supplier shall furnish MSDS and certified test reports and drawings, as listed in Section 11.1 in this Specification one month before transformers are shipped. These documents shall be submitted to: City of Vernon Utilities Department 4305 Santa Fe Avenue Vernon Ca, 90058 Phone: (323) 583-8811 Attention: Ramon Z. Abueg Assistant Director of Engineering and Operations 16 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS Attachment A. Transformer Sizes TOTAL QUANT KA ; PR)MAR' KV SEO D 3 500 7.2 277/480 2 750 7.2 277/480 1 150 16.34 120/208 3 300 16.34 277/480 1 500 16.34 277/480 3 750 16.34 277/480 3 1000 16.34 277/480 2 2500 16.34 277/480 1 3750 16.34 277/480 LINE A ONE CIRCUIT (RADIAL) TWO CIRCUIT (LOOPED) CL AY-O-NET LINE A moo-- LINE B CL BAY-O-NET VERNON LIGHT AND POWER EQUIPMENT: SPECIFICATION TR2 ADDITIONAL X� CIRCUIT CONNECTIONS 11/2/01 i I AV NO I REVISION I DATE I APPV'D BY I ATTACHMENT B 70 MAX RADIATORS MAY I EXTEND BEYOND THE —7 DIMENSIONS SHOWN x z a o co PLAN �- SEE NOTE 2 -C EXTERNALLY REPLACEABLE CL FUSES O uo uo NAMEPLATE x H1 H2 H3 TRANS SW. Q o 0 :2 v) x x 1 3 F<_ O v) x x 0 2 C� Z Y i H1 H2 H3 a 2-1/2" CONDUIT HOLE (SEE NOTE 3) I 40-1/2" MIN 22" MIN. ELEVATION NOTES: BAY-O-NET FUSE SCHEMATIC DIAGRAM 1. ALL DIMENSIONS AND CLEARANCES SHALL CONFORM WITH ANSI C57.12.26. 2. CURRENT LIMITING FUSES INTERLOCKED WITH TRANSFORMER SWITCH. X ' x X X 0 1 2 3 3. 2-1/2" CONDUIT HOLE SHALL BE LOCATED IN THE CENTER (BOTH HORIZONTALLY AND VERTICALLY) OF THE LOW VOLTAGE CABINET SILL. VERNON UTILITIES DEPARTMENT EQUIPMENT: SPECIFICATION TR2 ONE -CIRCUIT PADMOUNTED TRANSFORMERS 75 THROUGH 500 KVA 08y 0 10/30/01 NO REVISION DATE APPV'D ATTACHMENT C VIVt-LIKVVII I'HUMVVIVIC.0 IKHIV Jf VRMCKJ 1 Q 0 z F_ W N 0 z Y Q a 750 THROUGH 3750 KVA RADIATORS MAY EXTEND BEYOND THE DIMENSIONS SHOWN F--- 28" MIN 22" MIN PLAN EXTERNALLY REPLACEABLE CL FUSES NAMEPLATE UO UO UO HI H2 93 TRANS SW. O 0. x x i 3 O O x x 0 2 ELEVATION DIM 750, 1000 & 1500 KVA 2000 AND 3750 KVA A 77" MAX 87" MAX B 80" MAX 85" MAX C 76" MAX 90" MAX D 26" MIN 26" MIN E 42" MIN 42" MIN SECONDARY BUSHING LOCATIONS TO CONFORM WITH ANSI STANDARD C57.12.22 - FIG. 3 2-1/2" CONDUIT HOLE (SEE NOTE 3) 6" 6" 02-1/2" CONDUIT HOLE ELEVATION NOTES: 1. ALL DIMENSIONS AND CLEARANCES SHALL CONFORM WITH ANSI C57.12.26. 2. CURRENT LIMITING FUSES INTERLOCKED WITH TRANSFORMER SWITCH. 3. 2-1/2" CONDUIT HOLE SHALL BE LOCATED IN THE CENTER (BOTH HORIZONTALLY AND VERTICALLY) OF THE LOW VOLTAGE CABINET SILL. VERNON LIGHT AND POWER EQUIPMENT: SPECIFICATION TR2 ONE -CIRCUIT PADMOUNTEC TRANSFORMERS 750 THROUGH 3750 KVA 1 9/11/03 JL NO REVISION DATE APPV'D BY ATTACHMENT D SUPPORTING DOCUMENTS r w. i �Ir ', EQUIPMENT PURCHASE CONTRACT 2 3 THIS AGREEMENT is made, entered into and executed. in 4 duplicate originals, either copy of which may be considered and used as if Th 5 the original hereof for all purposes, as of this tU day of November, 6 2003, in the City of Vernon, County of Los Angeles, California 7 BY AND BETWEEN THE CITY OF VERNON (hereinafter referred to as 8 the "City") 4305 Santa Fe Avenue 9 Vernon, CA 90058 10 AND ABB, INC. (hereinafter referred to as 11 "ABB") 2945 Harding St., Suite 207 12 Carlsbad, CA 92008 13 RECITALS 14 WHEREAS, on October 14, 2003, the City requested proposals 15 or bids for nine (9) bid items totaling nineteen (19) Padmounted 16 Distribution Transformers (Bid No. 1429) needed by the City's Light & 17 Power Department; and 18 WHEREAS, the City is permitted to accept or reject any or 19 all quotations received on the bid items; and 20 WHEREAS, on or about November 4, 2003, the City received 21 various proposals for the sale of Padmounted Distribution Transformers 22 identified in Bid No. 1429, with each of the nine bid items quoted 23 separately; and ' 24 WHEREAS, on November 3, 2003, ABB submitted a bid; and 25 WHEREAS, on November 4, 2003, the City opened the bid 26 submitted by ABB, as well as other bids for the items identified in 27 Bid No. 1429; and 28 WHEREAS, the City desires to purchase the following bid s M { 1 items"from ABB: three (3) 500 KVA 7.2 277/480 Padmounted Transformers; 2 one (1) 150 KVA 16.34 120/208 Padmounted Transformer; three (3) 300 3 KVA 16.34 277/480 Padmounted Transformers; three (3) 1000 KVA 16.34 4 277/480 Padmounted Transformers; and, two (2) 2500 KVA 16.34 277/480 5 Padmounted Transformers per City of Vernon Specification No. TR2-2003, 6 for a total of twelve (12) Padmounted Transformers. 7 NOW, THEREFORE, THE PARTIES HERETO DO MUTUALLY AGREE AS SET 8 FORTH HEREIN: 9 1. Purchase. ABB agrees to sell and deliver to the City a 10 total of twelve (12) Padmounted Transformers referenced above pursuant 11 to City of Vernon Specification No. TR2-2003, as identified in ABB's 1.2 November 3, 2003 bid and which meet the specifications contained in 13 City of Vernon Bid No. 1429, dated October 14, 2003 (collectively 14 referred to as the "Bid Documents"). A copy of the Bid Documents are 15 attached hereto as Exhibit "A" and incorporated herein by reference. 16 2. Time of Performance. ABB's performance shall commence 17 upon the full execution of this Contract and shall be completed by ABB 18 within 10 weeks after receipt of order. 19 3. Price. The City agrees to purchase twelve (12) 20 Padmounted Transformers from ABB for the total sum of Ninety -Seven 21 Thousand Ninety -Nine Dollars and No Cents ($97,099.00). This price 22 includes freight and excludes sales tax. 23 4. Delivery. Consistent with the Bid Documents, ABB agrees 24 to deliver the twelve (12) Padmounted Transformers on a flatbed truck 25 for side unloading by forklift at ground level to the Soto Yard at 26 2800 Soto Avenue, Vernon, California. ABB shall notify the City 48- 27 hours prior to delivery to make arrangements for gates to be opened. 28Delivery shall be scheduled for Monday through Thursday between the -2- 1 1 hours'of 7 a.m. and 3 p.m. 2 5. Warranties. ABB warrants title to the Padmounted 3 Transformers purchased hereunder and any part thereof to be free of 4 any claim or any security interest, lien or encumbrance. ABB also 5 warrants that the Padmounted Transformers will be delivered new and 6 shall be free from defects. ABB shall provide, at a minimum, a one 7 (1) year labor and material warranty to begin upon acceptance of the 8 Padmounted Transformers by the City. All manufacturers' warranties, 9 any warranties typically provided by ABB and any other warranties made 10 applicable by law shall apply to the City's purchase of the Padmounted 11 Transformers. 12 6. Governing Law. The validity, interpretation and 13 performance of this Contract shall be controlled and construed under 14 the laws of the State of California. 15 7. Forum Selection. Any action brought relating to this 16 Contract shall be brought and held exclusively in a State Court in the 17 County of Los Angeles, California. 18 8. Notices. Notices to the parties, unless otherwise 19 requested in writing, shall be sent to: 20 City: THE CITY OF VERNON 21 ATTN: DOLORES FONSECA PURCHASING ASSISTANT 22 4305 SANTA FE AVENUE VERNON, CA 90058-0805 23 ABB: ABB, INC. 24 ATTN: JEFF VIVIAN 2945 HARDING STREET, SUITE 207 25 CARLSBAD, CA 92008 26 9. Risk of Loss. 27 Title and risk of loss or damage shall pass to the City and 28 delivery shall be deemed to be complete upon delivery FOB jobsite or -3- 1 hours'of 7 a.m. and 3 p.m. 2 5. Warranties. ABB warrants title to the Padmounted 3 Transformers purchased hereunder and any part thereof to be free of 4 any claim or any security interest, lien or encumbrance. ABB also 5 warrants that the Padmounted Transformers will be delivered new and 6 shall be free from defects. ABB shall provide, at a minimum, a one 7 (1) year labor and material warranty to begin upon acceptance of the 8 Padmounted Transformers by the City. All manufacturers' warranties, 9 any warranties typically provided by ABB and any other warranties made 10 applicable by law shall apply to the City's purchase of the Padmounted 11 Transformers. 12 6. Governing Law. The validity, interpretation and 13 performance of this Contract shall be controlled and construed under 14 the laws of the State of California. 15 7. Forum Selection. Any action brought relating to this 16 Contract shall be brought and held exclusively in a State Court in the 17 County of Los Angeles, California. 18 8. Notices. Notices to the parties, unless otherwise 19 requested in writing, shall be sent to: 20 City: THE CITY OF VERNON 21 ATTN: DOLORES FONSECA PURCHASING ASSISTANT 22 4305 SANTA FE AVENUE VERNON, CA 90058-0805 23 ABB: ABB, INC. 24 ATTN: JEFF VIVIAN 2945 HARDING STREET, SUITE 207 25 CARLSBAD, CA 92008 26 9. Risk of Loss. 27 Title and risk of loss or damage shall pass to the City and 28 delivery shall be deemed to be complete upon delivery FOB jobsite or -3- 1 (I 1 2 3 4 5 6 7 8 9 10 11 12 131I 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 upon'tnoving into storage at the City's request, whichever occurs first. 10. Attorneys' Fees. In the event that it becomes necessary for either party to this Agreement to enforce any of the provisions of this Agreement, the parties agree that a court of competent jurisdiction may determine and fix reasonable attorney's fees to be paid to the successful litigant. WITNESS WHEREOF, the parties have caused this Agreement to be executed by and through their authorized officers on the date, month and year first written above. ATTEST: BRUCE V. MALKENHORST, City Clerk APPROVED AS TO FORM: �: 2,1'r-, ERIC T. FRESCH, ity Attorney CITY OF VERNON By: , LEONIS C. MALB G, �MaV ABB, INC. By: AC Tit 1 e : Vim' ZZ Title. -4- , 1UU ,cU e-ooli 114vv-1/-uJ J:Lutlm; HAUL 2/2 ABB INC. SECRETARY'S CERTIFICATE I, E. Barry Lyon, Assistant Secretary of ABB Inc. (the "Company") hereby certifies that the following resolutions were duty adopted on November 14, 2003 by Unanimous Written Consent of the Directors of the Company, and have not been modified or rescinded to date; WHEREAS, the Company entered into negotiations to sell and deliver certain products and services to the City of Vernon, California, and WHEREAS, the Company and the City have determined to enter into written agreements to provide certain goods and services to the City. NOW THEREFORE, it is hereby RESOLVED, that the Company be and it is hereby authorized to enter into certain contracts and agreements from time to time for the safe of goods and services to the City of Vernon, California, and FURTHER RESOLVED, that the following employees be, and each is hereby, authorized to execute and deliver to the City of Vernon, Califomia, such contracts and agreements for the sale, delivery and installation, as the case may be, of products and the provision of services in each case upon such terms and conditions as each such authorized employee shall agree, such agreement to be evidenced by the execution and delivery of each such contract and agreement: John Sullivan President, Power Technology Division USA Trent Spear Chief Financial Officer, Power Technology Division USA .lack Dwyer Vice President Sales and Marketing, Power Technology Division USA Azar Chowdry Vice President Western Region, Power Technology Division USA David Onuscheck Assistant General Counsel and Asst. Secretary, Power Technology Division USA IN WITNESS WHEREOF, the undersigned has signed this Certificate as of this 17th day of November. 2003. ABB Inc. i Name: E. Ba yo Title: Assistant Secretary REQ,"JEST FOR QUOTATIONS NOT A PURCHASE ORDER DIRECT ALL INQUIRIES TO: CITY PURCHASING AGENT TELEPHONE (323) s83-8811 CITY OF VERNON, CALIFORNIA PURCHASING DEPARTMENT CITY HALL 4305 Santa Fe Ave. - Vernon, California 90058 TO: ABB, Inc., attn: Jeff Vivian —294 Nardin Ctraat Ste 207 Carlsbad, CA 92008 FOR CITY USE• :,QUOTATION NO. DATEMAILED REC'D BY CITY 1 i ♦• ,� J Please quote hereon the lowest net price you can furnish the articles or services specified below. Quote on each item separately. qualify quotations as "all or none" by stating so on body of form. City reserves the right to accept Bidder may or reject quotations received items. In order to maintain their name on City's Bidder File, Vendor should return this form whether a price is quoted or not. on any or all QUANTITY DESCRIPTION NET UNIT PRICE TOTAL Padmount Transformers as per attached specifications No. TR2-2003, dated September 15, 2003 KVA PRIMARY VOLTAGE KV SECONDARY VOLTAGE 3 500 7.2 277/480 YrJ3 1-7,g19 2 750 7.2 277/480 $c)ILP I101D3 2- 1 150 16.34 120/208 4141 41. q -7 3 300 16.34 277/480 q-7 2-5 14.1 -7 _ 1 500 16.34 277/480 509 53 $ � 3 750 16.34 277/480 -7 qq p D 3 1000 16.34 277/480 q6 31P -3q-7 zneos 2 2500 16.34 277/480 iLe 0.5 32,1'qE) 1 3750 16.34 277/480 y372D g3,12a Deliver on flatbed truck for side unloading by forklift at ground level, Please notify RMI-US at (323) 589-9498 (48) hours prior to delivery. If you have any questions, -Total e j�Cgj please contact Jose Lugo at (323) 583-8811, ext. 276. I,�; -----------PLEASE NOTE --------- Bid number must be indicated on the outside of the envelope; otherwise, bid will not be accepted. IF INSUFFICIENT SPACE PROVIDED ABOVE FOR PROPOSAL. ATTACH RIDER OR SUPPLEMENT. CASH DISCOUNTS QUOTED FOR PERIODS OF LESS THAN 30 DAYS WILL NOT BE CONSIDERED WHEN ORDER IS AWARDED. BIDS RECEIVED IN RESPONSE TO THIS REQUEST FOR QUOTATION WILL BE OPENED IN CITY PURCHASIN(; AGENT S OFFICE ON THE' 4th DAY OF NAV Pmhpp 20 0-3 AT —2-( DOTE: Quote prices exclusive of Sales Tax and. Excise T es. A. Indicate Sales Tax in this space ..............B. Indicate Excise Tax in this space $ ..................................................... .... ....... . B. Above quotations subject to Cash Discount of ........... 0...................................%, F.O.B.................�.t. C. To be delivered to CITY OF VERNON at..... 4 .... ..At...U... Cll� ..).1�� %f 10.C1... �% .....-1 .?.....................................:............. We (1) agree to furnish above in ... ..-.tU..wc.r a5.....days from receipt of purchase order at prices specified. FOR...........1. �.. R......................................................... / % > Firm Name )ATE ...... 1..! ../.1� ............................. SIGN HERE ....... Q ......... ....1t..l� J.. N.............................. MAIL TO PURC SIN D 12102 CO 0-4OD04�- W N-' M t ' o aD aD co ao 0o aD oD oD r. N 0 0 0 0 0 O O O Mmmmmmmmmmmmmmmmmm � m � a�i i can cOn u�i can can m m m m m m m m m m m m m-nm m mmmmmmmmm OOOOOOOOOm yDDDDDDDZ >DDDDDDDDDO =00000000z =2=22==2(1) mmmmmmmmm zzzzzzzzz q -4 -4 --1 -1 -i -4 -1 -A 2vvvvvvvvz �.r,pprrr,rprrir � f0 CJ 0 W W 0 0 W W 0�00000 z O O J N 0 CO Cn N OD O v NN0)C), I P PO>N 0CC) �U7N WN0OD O r O D O N w N N O N w 00 oIM O °D-•OWTWOO"y O i -4 O D O 0O1wC0WCDD0 (IDN)) r N OO"0CYI-4 ViOD0 N O CO) W m 0 0M-4M0 A- WNi =� ao v 0 D M Z> -W -n . - o i N W W -� W i N W O i C . .A Z m Z O 7� < ZZ (400O000tMO OOO000000y mm Op -u ;am D m �OT i i i i i i i N X im a O CO) r y n O z D I NJ Nf3-4NvNO1v NV N A A -a-+i--►000ODOD WNi000DOD--�O < O r D Q rn c w0)mv_(�71.�P OODD_' O1(DCO�l�0 N(D W CD OD - CD W "D X O(OOODO7-10) n m GeiNNa I n 669 0 W co W -'W J NCD0 V W0 m COD, OOODOODO1�N(D n m b m X n m z 0> is�,,D ca 0)� W o co J -P, -4 N OI OI R T --------------------------- --------------------- QUESTION: 6.2: Why interlock a loadbreak fuse to an on/off switch? Bay-o-net fuses are not normally interlocked to a switch. ------------------------------------------------------------------- Comments : 11.H: Gauge of steel in tank walls, cover, and bottom is 7ga. Gauge of steel in cooling fins is 16ga. Attachment D: Dimensions D and E equal or exceed minimums specified. -------------------------------------------------------------------- Pls Quote: 3 Phase, 60 Hertz, 65 Deg C AWR, 30 Deg C Avg Ambient, Radial, MTR (Padmounted), Green 7GY/3.29/1.5Munsell Primary : 7200 Connection HV1 Position is Delta HV kV BIL 095 HV1 Taps 2AN2BN (+2,-2 @ 2.5%) Secondary 480Y/277 Engr. Spec: TR2-2003 Revision: X Rev Date: 091503 Accessories: 200 amp HV bushing wells Special high voltage bushing pattern LV bushings with 4-hole NEMA spade terminals Fused bayonet no isolation link Oil -immersed partial range current limiting fuse ANSI, specific staggered low voltage pattern 2-position 200 amp LBOR transformer switch Fuse/switch interlock mechanism / Spare expulsion fuses (set of 6) v/ Dial type thermometer Liquid level gauge Drain valve and sampler Touch up paint (12 oz spray can) Mineral oil with inhibitor Provision for one (1) conduit entrance Special label(s) and/or decal(s) Additional nameplate Integral IV Spades ITEM QUANTITY KVA NET EACH SHIPMENT CUSTOMER CODE 1 9 500 5993 8-10 --------------------------------------t--- Pls Quote: 3 Phase, 60 Hertz, 65 Deg C AWR, 30 Deg C Avg Ambient, Radial, Small Power (Padmounted) , Green 7GY/3.29/1.5Munsell Primary,: 7200 Connection HV1 Position is Delta HV kV BIL 095 - HV1 Taps 2AN2BN (+2,-2 @ 2.5%) Secondary 480Y/277 Engr. Spec: TR2-2003 Revision: X Rev Date: 091503 Accessories: �00 amp HV bushing wells Special high voltage bushing pattern IV bushings with 12-hole NEMA spade terminals with supports Fused bayonet no isolation link Oil -immersed partial range current limiting fuse ANSI specific staggered low voltage pattern 2-position 200 amp LBOR transformer switch Fuse/switch interlock mechanism Spare expulsion fuses (set of 6) Dial type thermometer Liquid level gauge Drain valve and sampler Touch up paint (12 oz spray can) Mineral oil with inhibitor 24" deep cabinet Provision for one (1) conduit entrance Special label(s) and/or decal(s) Additional nameplate Integral IV Spade ITEM QUANTITY KVA NET EACH 2 6 750 8016 jl� SHIPMENT CUSTOMER CODE 8-10 ---------------------------------------------------------------------- Pls Quote: 3-,Phase, 60 Hertz, 65 Deg C AWR, 30 Deg C Avg Ambient, Radial,'MTR (Padmounted), Green 7GY/3.29/1.5Munsell Primary 16340 Connection HV1 Position is Delta HV kV BIL 095 HV1 Taps 2AN2BN (+2,-2 @ 2.5%) Secondary 208Y/120 Engr. Spec: TR2-2003 Revision: X Rev Date: 091503 Accessories: 200 amp HV bushing wells Special high voltage bushing pattern / IV bushings with 4-hole NEMA spade terminals ✓ Fused bayonet no isolation link Oil -immersed partial range current limiting fuse ANSI specific staggered low voltage pattern 2-position 200 amp LBOR transformer switch Fuse/switch interlock mechanism Spare expulsion fuses (set of 6) Dial type thermometer Liquid level gauge Drain valve and sampler Touch up paint (12 oz spray can) Mineral oil with inhibitor Provision for one (1) conduit entrance Special la:bel(s) and/or decal(s) Additional nameplate Integral IV Spades ITEM QUANTITY KVA NET EACH SHIPMENT CUSTOMER CODE 3 3 150 4147 8-10 ---------------------------------------------------------------------- y Pls Quote: 3 Phase, 60 Hertz, 65 Deg C AWR, 30 Deg C Avg Ambient, Radial, MTR (Padmounted), Green 7GY/3.29/1.5Munsell Primary : 16340 Connection HV1 Position is Delta HV kV BIL 095 HV1 Taps 2AN2BN (+2,-2 a 2.5%) Secondary 480Y/277 Engr. Spec: TR2-2003 Revision: X Rev Date: 091503 Accessories: 200 amp HV bushing wells Special high voltage bushing pattern LV bushings with 4-hole NEMA spade terminals Fused bayonet no isolation link Oil -immersed partial range current limiting fuse ANSI specific staggered low voltage pattern 2-position 200 amp LBOR transformer switch Fuse/switch interlock mechanism Spare expulsion fuses (set of 6) Dial type thermometer Liquid level gauge Drain' valve and sampler Touch up paint (12 oz spray can) Mineral oil with inhibitor Provision for one (1) conduit entrance Special label(s) and/or decal(s) Additional nameplate Integral LV Spades ITEM QUANTITY KVA NET EACH SHIPMENT CUSTOMER CODE 4 9 300 4725 8-10 --------=------------------------------------------------------------- Pls Quote: 3 Phase, 60 Hertz, 65 Deg C AWR, 30 Deg C Avg Ambient, Radial, MTR (Padmounted), Green 7GY/3.29/1.5Munsell Primary_: 16340 Connection HV1 Position is Delta HV kV BIL 095 HV1 Taps 2AN2BN (+2,-2 @ 2.5t) Secondary 480Y/277 Engr. Spec: TR2-2003 Revision: X Rev Date: 091503 Accessories: 200 amp HV bushing wells Special high voltage bushing pattern LV bushings with 8-hole NEMA spade terminals LV spade supports Fused bayonet no isolation link Oil -immersed partial range current limiting fuse ANSI, specific staggered low voltage pattern 2-position 200 amp LBOR transformer switch Fuse/switch interlock mechanism Spare expulsion fuses (set of 6) Dial type thermometer Liquid level gauge Drain valve and sampler Touch up paint (12 oz spray can) Mineral oil with inhibitor Provision for one (1) conduit entrance Special label(s) and/or decal(s) Additional nameplate Integral IV Spades ITEM QUANTITY KVA NET EACH SHIPMENT CUSTOMER CODE 5 3 500 5988 8-10 Pls Quote: 3 Phase, 60 Hertz, 65 Deg C AWR, 30 Deg C Avg Ambient, Radial, Small Power (Padmounted) , Green 7GY/3.29/1.5Munsell Primary : 16340 Connection HV1 Position is Delta HV kV BIL 095 HV1 Taps 2AN2BN (+2,-2 @ 2.5%) Secondary 480Y/277 Engr. Spec: TR2-2003 Revision: X Rev Date: 091503 Accessories: 200 amp HV bushing wells Special high voltage bushing pattern IV bushings with 12-hole NEMA spade terminals with supports Fused bayonet no isolation link Oil -immersed partial range current limiting fuse ANSI specific staggered low voltage pattern 2-position 200 amp LBOR transformer switch Fuse/switch interlock mechanism Spare expulsion fuses (set of 6) Dial type thermometer Liquid level gauge Drain valve and sampler Touchup paint (12 oz spray can) Mineral oil with inhibitor 24" deep cabinet Provision for one (1) conduit entrance Special label(s) and/or decal(s) Additional nameplate Integral IV Spade ITEM QUANTITY KVA NET EACH SHIPMENT CUSTOMER CODE 6 9 750 7990 8-10 7 9 1000 9536 8-10 ---------------------------------------------------------------------- Pls Quote: 3 Phase, 60 Hertz, 65 Deg C AWR, 30 Deg C Avg Ambient,', Radial, Small Power (Padmounted) , Green 7GY/3.29/1.5Munsell Primary : 16340 Connection HV1 Position is Delta HV kV BIL 095 HV1 Taps 2AN2BN (+2,-2 @ 2.5%) Secondary 480Y/277 Engr. Spec: TR2-2003 Revision: X Rev Date: 091503 Accessories: 200 amp HV bushing wells gpecial high voltage bushing pattern ��- IV bushings with 16-hole NEMA spade terminals with supports O/ae' Fused bayonet no isolation link Oil -immersed partial range current limiting fuse ANSI specific staggered low voltage pattern 2-position 200 amp LBOR transformer switch Fuse/switch interlock mechanism Spare expulsion fuses (set of 6) Dial type thermometer Liquid level gauge Drain valve and sampler Touch up paint (12 oz spray can) Mineral oil with inhibitor 24" deep cabinet Provision for one (1) conduit entrance Special label(s) and/or decal(s) Additional nameplate Integral IV Spade ITEM QUANTITY KVA NET EACH SHIPMENT CUSTOMER CODE 8 6 2500 16095 8-10 ---------------------------------------------------------------------- Prices are firm for shipments through 12/31/04 for all items awarded ABB within'45 days of bid opening. Losses quote -rare guaranteed average, ANSI tolerances apply. Nameplate will state "Filled with non -PCB mineral oil that contained less than 1 PPM at time of manufacture". Negotiation and item numbers must be referenced upon order entry. Shipment subject to available production space at time of order receipt,at division. All door fastening bolts are made of AISI 300 series stainless steel or silicon bronze for corrosion resistance in full compliance with ANSI C57.12.28-1988. View the status of your orders by visiting web site at <www.abbdtd.com> View requested construction drawings electronically at the same site: Order status, upper right hand corner, click on nameplate icon or drawing icon. Generally not available less than two weeks after order entry, unless a duplicate style is ordered. Prices are F.O.B. point of shipment. ABB INC. General Terms and Conditions of .Sale, ABBGTC073101 and supplemental terms and conditions, July 2002, apply. Orders for renewal parts and transformers cannot be combined on the same order - they must be entered on separate orders. ABB January, 2002 The ABB MTR is an oil -filled, three-phase, commercial padmounted distribution transformer specifically designed for servicing such underground distribution loads as shopping centers, schools, Institutions and industrial plants. It is available in both live front and dead front construction, for radial or loop feed applications, with or without taps. ABB MTR meets the following Industry standards: ANSI C57.12.00 ANSI C57.12.22 ANSI C57.12.26 ANSI C57.12.28 ANSI C57.12.29 ANSI C57.12.70 ANSI C57.12.80 ANSI C57.12.90 ANSI C57.91 NEMA TR1 WUG 2.13 Rev. 4 Ratings • 45 through 1500 WA • 65° C average winding rise • 60 hertz standard, 50 hertz optional • High voltages: 4160 Grd Y/2400 through 34,500 Grd Y/19,920 for Grounded Wye systems; 2400 through 34,500 for Delta systems; various dual high•voitages • Taps: All voltages are available with or without taps • Insulation classes: 35 kV, 150 kV BIL and below ABB Inc. Distribution Transformers Athens, GA Jefferson City. MO !SO 0001 cent~ • Low voltages: 208Y/120, 216Y/125, 460Y/265, 480Y/277, 480A, 240A and 240A with 120 volt mid -tap in one phase; (4160Y/2400, 4160A, 2400A, 2400/4160Y/2400 for 500 WA and larger) Standard Features: 1. Four lifting lugs. 2. Bolted -on terminal compartment (18" deep) with removable front sill. 3. Hinged lift-off cabinet doors. 4. Interlocked penta-head bolt/padlock handle operates a cam assembly which is part of the 3-point door latching mechanism. (A hex -head bolt is available.) 5. For Ova front construction, externally clamped high voltage porcelain bushings with a single eyebolt, clamp -type connector (accommo- dates #6 AWG solid to 250 MCM stranded conductors). 6. For dead front construction, exter- nally clamped high voltage bushing wells for loadbreak or non-loadbreak Inserts. 7. Lightning arrester mounting pads pave front only). 8. Tank ground pads (1 in HV, 1 in LV) 9. Steel high/low voltage compartment barrier. 10. Two 1/2" penta-head bolts must be removed from the flange formed on the steel highAow barrier before the HV door can be opened (1/2" hex - head bolts available as an option). PDL 46-301 Page 1 MTR Three Phase Padmounted Transformer 45-15OOkVA 11. Externally clamped low voltage bushings with threaded copper stud for full load current below 2100 amps. Externally clamped integral low voltage bushings for current above 2100 amps. NEMA spades provided per ANSI hole requirements. 12. Nameplate. 13. Fill plug and self -actuating pressure relief device. 14. Drain plug.. 15. Removable neutral ground strap. 16. Five -legged core/coil assembly. 17. Handhole cover bolted onto tank top (protected by weathercover). 18. Panel -type coolers. 19. NEMA safety labels. 20. The paint finish process applies a durable, corrosion resistant finish to the product. The finish meets or exceeds all the performance require- ments of ANSI C57.12.28. The multi- step process includes an epoxy primer uniformly applied by cationic electro- deposition and a urethane top coat. Optional Features!, Primary Termination • Externally -clamped bushing wells with loadbreak or non-loadbreak inserts. • Integral loadbreak bushings. Secondary Termination • Externally -clamped bushings with NEMA 6-hole, 8-hole, 10-hole, or 12-hole spades. • Spade supports are available. They are provided for 8-hole spades and larger when the current is 1400 amps or greater. Primary Switching • LBOR oil switch: one for radial, two for loop feed. • Externally -operated tap changer. • Externally operated dual voltage switch. • Externally operated delta-wye switch. Overcurrent Protection • Internal primary protective links. • Bayonet -type expulsion fuses. • Drawout, loadbreak current limiting fuses, with or without interlocking transformer switch. • Secondary oil circuit breaker. • Internal, partial -range current limiting fuses. Overvoltage Protection • Distribution class, metal oxide arresters, 3-36 kV. • Distribution class, valve -type lightning arresters, 3-27 W. Construction Options • 24' and 30" deep terminal cabinet. • Drain valve and sampling device. • Mounting plate for Crs or PT's. • Interphass barters. • Molded case extemai secondary breaker. • Substation Accessories - Oil gauge, thermometer, drain valve and sampler, pressure -vacuum gauge provision. • Weathercover. • Transformers may feature an optional weatheroover over the cabinet which Is hinged to allow clearance for replacement of the bayonet -type fuses. i. • The weathercover can be lifted easily Into place and secured With a single supporting arm. • The weathercovec requires no additional holddown hardware. Live Front, Radial Feed ANSI Fig. 1, 2, and 3 (C57.12.22) Gal. of KVA A B C D E Wt. Oil 75 54.5 56 44.8 44.8 56 2280 115 112 54.5 56 44.8 44.8 56 2400 115 150 54.5 56 44.8 44.8 56 2700 125 225 54.5 56 49.8 46.8 56 3350 150 300 64.5 60 50.8 46.8 56 3650 165 500 58.5 66 58.8 48.8 56 5200 200 750 66.5 81 60.8 50.8 66 7100 270 1000 66.5 84 62.8 52.8 66 7900 320 1500 66.5 86 66.8 54.8 66 9700 390 Dead Front, Radial Feed ANSI Fig. 1, 3, and 4 (C57.12.26) Gal. of KVA A B C D E Wt. Oil 75 46.5 62 44.8 44.8 62 2350 115 112 46.5 62 44.8 44.8 62 2460 115 150 46.5 62 44.8 44.8 62 2700 125 225 46.6 62 49.8 46.8 62 3400 150 300 46.5 62 50.8 46.8 62 3700 165 500 54.5 66 58.8 48.8 62 5400 200 750 58.5, 81 60.8 50.8 66 7100 270 1000 66.5 84 62.8 52.8 66 7900 320 1500 66.5 86 66.8 64.8 66 9700 390 Dead Front, Loop Feed ANSI Fig. 2, 3, and 4 (C57.12.26) Gal. of KVA A B C D E Wt. Oil 75 54.5 66 44.8 44.8 66 2400 120 112 64.5 66 44.8 44.8 66 2500 120 160 54.5 66 44.8 44.8 66 2800 130 225 54.5 66 49.8 46.8 66 3500 160 300 54.5 66 50.8 46.8 66 3800 170 500 64.5 68 58.8 48.8 66 5600 200 750 66.5 82 60.8 50.8 70 7400 270 1000 66.5 86 62.8 52.8 70 8200 320 1500 66.5 88 66.8 54.6 70 10300 390 Design Dimensions Approximate weights and dimensions: Dimensions are in inches, weights are in pounds. Dimensions may change to meet the customer spec. Top View I ImE"48ICNs L i MINIMUM CABLE CPENMO Front View ABB Inc. Distribution Transformers Athens, GA Jefferson City, MO ISO 9001 Certh7ed 3' MIN. January, 2002 ABB January, 2002 The ASS MTR is an oil -filled, three-phase, commercial padmounted distribution transformer specifically designed for servicing such underground distribution loads as shopping benters, schools, institutions and industrial plants. It is available in both live front and dead front construction, for radial or loop feed applications, with or without taps. ABB MTR meets the following industry standards: ANSI C57.12.00 ANSI C57.12.22 ANSI C57.12.26 ANSI C57.12.28 ANSI C57.12.29 ANSI C57.12.70 ANSI C57.12.80 ANSI C57.12.90 ANSI C57.91 NEMA TRi WUG 2.13 Rev. 4 Ratings • 45 through 1500 WA • 65" C average winding rise • 60 hertz standard, 50 hertz optional • High voltages: 4160 Grd Y/2400 through 34,500 Grd Y/19,920 for Grounded Wye systems; 2400 through 34,500 for Delta systems; various dual high voltages • Taps: All voltages are available with or without taps • Insulation classes: 35 W. 150 kV BIL and below ASS Inc. Distribution Transformers Athens, GA Jefferson City, MO /SO 900.1 CoMfled • Low voltages: 208Y/120, 216Y/125, 460Y/265, 480Y/277, 480A, 240A and 240A with 120 volt mid -tap In one phase; (4160Y/2400, 4160A, 2400A, 2400/4160Y/2400 for 500 WA and larger) Standard Features: 1. Four lifting lugs. 2. Bolted -on terminal compartment 08" deep) with removable front sill. 3. Hinged, lift-off cabinet doors. 4. Interlocked penta-head bolt/padlock handle operates a cam assembly which is part of the 3-point door latching mechanism. (A hex -head bolt is available.) S. For live front construction, externally clamped high voltage porcelain bushings with a single eyebolt, clamp -type connector (accommo- dates #6 AWG solid to 250 MCM stranded conductors). 6. For dead front construction, exter- nally clamped high voltage bushing wells for loadbreak or non-loadbreak Inserts. 7. Lightning arrester mounting pads (live front only). 8. Tank ground pads (1 In HV, 1 In LV) 9. Steel high/low voltage compartment barrier. 10. Two 1/2" penta-head bolts must be removed from the flange formed on the steel highAow barrier before the HV door can be opened (1/2" hex - head bolts available as an option). PDL 46-301 Page 1 MTR Three Phase Padmounted Transformer 45-15OOkVA 11. Externally clamped low voltage bushings with threaded copper stud for full load current below 2100 amps. Externally clamped integral low voltage bushings for current above 2100 amps. NEMA spades provided per ANSI hole requirements. 12. Nameplate. 13. Fill plug and self -actuating pressure relief device. 14. Drain plug. 15. Removable neutral ground strap. 16. Five -legged core/coil assembly. 17. Handhole cover bolted onto tank top (protected by weathercover). 18. Panel -type coolers. 19. NEMA safety labels. 20. The paint finish process applies a durable, corrosion resistant finish to the product. The finish meets or exceeds all the performance require- ments of ANSI C57.12.28. The multi- step process includes an epoxy primer uniformly applied by cationic electro- deposition and a urethane top coat. Optional Features'` Primary Termination • Externally -clamped bushing wells with loadbreak or non-loadbreak Inserts. • Integral loadbreak bushings. Secondary Termination • Externally -clamped bushings with NEMA 6-hole, 8-hole,10-hole, or 12-hole spades. • Spade supports are available. They are provided for 8-hole spades and larger when the current is 1400 amps or greater. Primary Switching • LBOR oil switch: one for radial, two for loop feed. • Externally -operated tap changer. • Externally operated dual voltage switch. • Externally operated delta-wye switch. Overcurrent Protection • internal primary protective links. • Bayonet -type expulsion fuses. • Drawout, loadbreak current limiting fuses, with or without interlocking transformer switch. • Secondary oil circuit breaker. • Internal, partial -range current limiting fuses. Overvoltage Protection • Distribution class, metal oxide arresters, 3-36 kV. • Distribution class, valve -type lightning arresters, 3-27 kV. Construction Options • 24" and 30" deep terminal cabinet. • Drain valve and sampling device. • Mounting plate for CT's or Pre. • Interphase barriers. • Molded case external secondary breaker. • Substation Accessories - Oil gauge, thermometer, drain valve and sampler, pressure -vacuum gauge provision. • Weathercover. • Transformers may feature an optional weathercover over the cabinet which Is hinged to allow clearance for replacement of the bayonet -type fuses. • The weathercover can be lifted easily Into place and secured With a single supporting arm. . • The weathercover requires no additional holddown hardware. Live Front, Radial Feed ANSI Fig. 1, 2, and 3 (C57.12.22) Gal. of KVA A B C D E Wt. Oil 75 54.5 56 44.8 44.8 56 2280 115 112 54.5 56 44.8 44.8 56 2400 115 150 54.5 56 44.8 44.8 56 2700 125 225 54.5 56 49.8 46.8 56 3350 150 300 54.5 60 50.8 46.8 56 3650 165 500 58.5 66 58.8 48.8 56 5200 200 750 66.5 81 60.8 50.8 66 7100 270 1000 66.5 84 62.8 52.8 66 7900 320 1500 66.5 86 66.8 54.8 66 9700 390 Dead Front, Radial Feed ANSI Fig. 1, 3, and 4 (C57.12.26) Gal, of KVA A B C D E wt. Oil 75 46.5 62 44.8 44.8 62 2350 115 112 46.5 62 44.8 44.8 62 2450 115 150 46.5 62 44.8 44.8 62 2700 125 225 46.5 62 49.8 46.8 62 3400 150 300 46.5 62 60.8 46.8 62 3700 165 500 54.5 66 68.8 48.8 62 6400 200 750 58.5 81 60.8 60.8 66 7100 270 1000 66.5 84 62.8 52.8 66 7900 320 1500 66.6 86 66.8 54.8 66 9700 390 Dead Front, Loop Feed ANSI Fig. 2, 3, and 4 (C57.12.26) Gal. of KVA A B C D E Wt. Oil 75 54.5 66 44.8 44.8 66 2400 120 112 64.5 66 44.8 44.8 66 2500 120 150 54.5 66 44.8 44.8 66 2800 130 225 54.5 66 49.8 46.8 66 3500 160 300 54.5 66 50.8 46.8 66 3800 170 500 54.5 68 58.8 48.8 66 6600 200 750 66.6 82 60.8 50.8 70 7400 270 1000 66.5 86 62.8 52.8 70 8200 320 1500 66.5 88 66.8 54.8 70 10300 390 Design Dimensions Approximate weights and dimensions: Dimensions are In Inches, weights are in pounds. Dimensions may change to meet the customer spec. Top View I MON" PAD L---_ - _ J MIND M CABLE OPENtNO Front View MK ASS Inc. Distribution Transformers Athens, GA Jefferson City, MO January, 2002 ISO 9001 Certh7ed A1111 January, 2002 The ABB MTR is ad oil -filled, three-phase, commercial padmounted distribution transformer specifically designed for servicing such underground distribution loads as shopping denters, schools, Institutions and industrial plants. It is available in both live front and dead front construction, for radial or loop feed applications, with or without taps. ASS MTR meets the following Industry standards: ANSI C57.12.00 ANSI C57.12.22 ANSI C57.12.26 ANSI C57.12.28 ANSI C57.12.29 ANSI C57.12.70 ANSI C57.12.80 ANSI C57.12.90 ANSI C57.91 NEMA TR1 WUG 2.13 Rev. 4 Ratings • 2000 through 2500 WA • 65• C average winding rise. • 60 hertz standard, 50 hertz optional • High voltages: 7200 Grd Y/4160 through 34,500 Grd Y/19,920 for Grounded Wye systems; 4160 through 34,500 for Delta systems; various dual high voltages ABB Mc. Distribution Transformers Athens, GA Jefferson City, Mo ISO 9001 COMMed • Taps: All voltages are available with or without taps • Insulation classes: 35 kV, 150 kV BIL and below • Low voltages: 460Y/265, 4SOY/277, 480A,4160Y/2400, 24000,2400/ 4160Y/2400 Standard Features: 1. Four Nfting lugs. 2. Bolted -on terminal compartment (24" deep) with removable front sill. 3. Hinged, lift-off cabinet doors. 4. Interlocked penta-head bolt/padlock handle operates a cam assembly which Is part of the 3-point door latching mechanism. (A hex -head bolt is available.) S. For live front construction, externally clamped high voltage porcelain bushings with a single eyebolt, clamp - type connector (accommodates #6 AWG solid to 250 MCM stranded conductors). 6. For dead front construction, externally clamped high voltage bushing wells for loadbreak or non-loadbreak inserts. 7. Lightning arrester mounting pads (live front only). 8. Tank ground pads (1 in HV, 1 in LV). 9. Steel high/low voltage compartment barrier. PDL 46-302 Page 1 MTR Three Phase Padmounted Transformer 2000-2500 WA 10. Two 1/21 penta-head bolts must be removed from the flange formed on the steel high/low barrier before the HV door can be opened (1/2" hex -head bolts available as an option). 11. Externally clamped low voltage bushings with .,NEMA 10-hole spades. 12. Nameplate. 13. Fill plug and self4ctuating pressure relief device. 14. Drain plug. 15. Removable neutral ground strap. 16. Five -legged core/coil assembly. 17. Handhole cover bolted onto tank top (protected by weathercover). 18. Panel -type coolers. 19. NEMA safety labels. 20. The paint finish process applies a durable, corrosion resistant finish to the product. The finish meets or exceeds all the performance require- ments of ANSI C§7.12.28. The multi- step process inciddes an epoxy primer uniformly applied by cationic slec- trodeposition and a urethane top coat. Optional Features Primary Termination • Externally -clamped bushing wells with loadbreak or non-loadbreak Inserts. • Integral loadbreak bushings. Secondary Termination • Externally -clamped bushings with NEMA 6-hole, 8-hole, 10-hole, or 12- hole spades. • Spade supports are available. They are provided for 8-hole spades and larger when the current is 1400 amps or greater, Primary Switching • LBOR oil switch: one for radial, two for loop feed. • Externally -operated tap changer. • Externally operated dual voltage switch • Externally -operated delta-wye switch. Overourrent Protection • internal primary protective links. • Bayonet -type expulsion fuses. • Internal, partial -range current limiting fuses. Overvoltage Protection • Distribution class, metal oxide arresters, 3-36 kV. • Distribution class, valve -type lightning arresters, 3-27 kV. Construction Options • 18" and 30" deep terminal cabinet. • Drain valve and sampling device. • Mounting plate for CT's or PT's. • Interphase barriers. Design Dimensions Approximate weights and dimensions: Dimensions are in inches, weights are in pounds. Dimensions may change to meet the customer spec. Live Front, Radial Feed Dead Front, Radial Feed ANSI Fig. 1, 2, and 3 ANSI Fig. 1, 3, and 4 (C57.12.22) (C57.12.26) KVA A B C D E Wt. Gal. of OII 2000 70.5 92 68.8 58.8 70 12800 430 2500 70.6 98 70.8 58.8 70 14100 500 Top Vkw Front View (Dimensions are In Inches.) • Molded case external secondary breaker. • Substation Accessories - Oil gauge, thermometer, drain valve and sampler, pressure -vacuum gauge provision. • Weathercover. • Transformers may feature an optional weathercover over the cabinet which Is hinged to allow clearance for replacement of the bayonet -type fuses. • The weathercover can be lifted easily Into place and secured with a single supporting arm. • The weathercover requires no additional holddown hardware. Dead Front, Loop Feed ANSI Fig. 2, 3, and 4 (057.12.26) MAXIMUM PAD DIMENSIONS L I 42"- MINIMUM CABLE OPENING 3" MIN, ASS Inc. Distribution Transformers Athens, GA Jefferson City, MO January, 2002 130 9001 Certiifi ed TSB January, 2002 The ABB MTR is arl oil -filled, three-phase, commercial padmounted distribution transformer specifically designed for servicing such underground distribution loads as shopping centers, schools, institutions and industrial plants, It is available in both live front and dead front construction, for radial or loop feed applications, with or without taps. ABB MTR meets the following Industry standards: ANSI C57.12.00 ANSI C57.12.22 ANSI C57.12.26 ANSI C57.12.28 ANSI C57.12.29 ANSI C57.12.70 ANSI C57.12.80 ANSI C57.12.90 ANSI C57.91 NEMA TR1 WUG 2.13 Rev. 4 Ratings • 2000 through 2&00 WA • 65" C average winding rise • 60 hertz standard, 50 hertz optional • High voltages: 7200 Grd Y/4160 through 34,500 Grd Y/19,920 for Grounded Wye systems; 4160 through 34,500 for Delta systems; various dual high voltages ABB Inc. Distribution Transformers Athens, GA Jefferson City, MO ISO 9001 CertMed Taps: Ail voltages are available with or without taps Insulation classes: 35 kV, 150 kV BIL and below Low voltages: 460Y/265, 480Y/277, 480A, 4160Y/2400, 2400A, 2400/ 4160Y/2400 Standard Features: 1. Four lifting lugs. 2. Bolted -on terminal compartment (24" deep) with removable front sill. 3. Hinged, lift-off cabinet doors. 4. Interlocked penta-head bolt/padlock handle operates a cam assembly which Is part of the 3-point door latching mechanism. (A hex -head bolt is available.) 5. For live front construction, externally clamped high voltage porcelain bushings with a single eyebolt, clamp - type connector (accommodates #6 AWG solid to 250 MCM stranded conductors). 6. For dead front construction, externally clamped high voltage bushing wails for loadbreak or non-loadbreak inserts. 7. Lightning arrester mounting pads pave front only). 8. Tank ground pads (1 in HV, 1 in LV). 9. Steel high/low voltage compartment barrier. PDL 46-302 Page 1 MTR Three Phase Padmounted Transformer 2000-2500 WA 10. Two 1/2" pent& -head bolts must be removed from the flange formed on the steel high/ow barrier before the HV door can be opened (1/2" hex -head bolts available as an option). 11. Externally clamped low voltage bushings with. NEMA 10-hole spades. 12. Nameplate. 13. Fill plug and self -actuating pressure relief device. 14. Drain plug. 15. Removable neutral ground strap. 16. Five -legged coretcoil assembly. 17. Handhole cover bolted onto tank top (protected by weathercover). 18. Panel -type coolers. 19. NEMA safety labels. 20. The paint finish process applies a durable, corrosion resistant finish to the product. The finish meets or exceeds all the performance require- ments of ANSI C57.12.28. The multi- step process includes an epoxy primer uniformly applied by cationic elec- trodeposition and a urethane top coat. Optional Features Primary Termination • Externally -clamped bushing wells with loadbreak or non-loadbreak inserts. • Integral loadbreak bushings. Secondary Termination • Externally -clamped bushings with NEMA 6-hole, 8-hole, 10-hole, or 12- hole spades. • Spade supports are available. They are provided for 8-hole spades and larger when the current is 1400 amps or greater. Primary Switching • LBOR oil switch: one for radial, two for loop feed. • Externally -operated tap changer. • Externally operated dual voltage switch • Externally -operated delta-wye switch. Overcurrent Protection • internal primary protective links. • Bayonet -type expulsion fuses. • Internal, partial -range current limiting fuses. Overvoltage Protection • Distribution class, metal oxide arresters, 3-36 kV. • Distribution class, valve -type lightning arresters, 3-27 kV. Construction Options • 18' and 304 deep terminal cabinet. • Drain valve and sampling device. • Mounting plate for CT's or PT's. • Interphase barriers. Design Dimensions Approximate weights and dimensions: Dimensions are in inches, weights are in pounds. Dimensions may change to meet the customer spec. Live Front, Radial Feed Dead Front, Radial Feed ANSI Fig.1, 2, and 3 ANSI Fig. 1, 3, and 4 (C57.12.22) (C57.12.26) Gal, of KVA A B C D E Wt. Oil 2000 70.5 92 68.8 58.8 70 12800 430 2500 70.5 98 70.8 58.8 70 14100 500 Top View Front View (Dimensions am In inches.) • Molded case external secondary breaker. • Substation Accessories - Oil gauge, thermometer, drain valve and sampler, pressure -vacuum gauge provision. • Weathercover. • Transformers may feature an optional weathercover over the cabinet which Is hinged to allow clearance for replacement of the bayonet -type fuses. • The weathercover can be lifted easily Into place and secured with a single supporting arm. • The weathercover requires no additional holddown hardware. Dead Front, Loop Feed ANSI Fig. 2, 3, and 4 (C57.12.26) 3" MIN. I MAXIMUM PAD I DIMENSIONS 70' L �lT 42' 15.E MINIMUM CABLE OPENING I a• ABB Inc. Distribution Transformers Athens, GA Jefferson City, MO January, 2002 ISO 9001 Certified ABB Inc. Small Power Transformers P.O. Box 38, State Route 42 Bland, VA 24315 Quote dated 10/31 /2003 Prepared for: City of Vernon Project: City of Vernon In response to your request for quotation we are pleased to offer the following: ABB Quote number: DIR03199 Item number: 001 Quantity 2 3750 KVA Padmount 3 Phase 60 Hertz Oil Filled 65 Degree C Rise OA Self Cooled 30 Average/ 40 Maximum Ambient 6.00 Percent Impedance Guaranteed Minimum Impedance Phase relation: DYN 1 3300 Feet Maximum Altitude 64 dB(a) Guaranteed Sound Level (OA) Guaranteed Loss $ Evaluation: No load loss - 3420 Watts Total loss - 30500 Watts HIGH VOLTAGE High Voltage 16340 Delta 110KV BIL Wall Mounted Bushings in ANSI Segment 1 Aluminum Conductor Taps: 15480, 15910, 16340, 16770, 17200 Radial feed ABB LBOR 300 ampere 35 KV 150 KV BIL load break switch. Three 200 Amp Bushing Wells LOW VOLTAGE Low Voltage 480Y/277 30KV BIL Wall Mounted Bushings in ANSI Segment 1 Aluminum Conductor Welded on Aluminum Cast Resin Epoxy Bushings CORE/COIL DUTY FINISH FITTINGS Parking Stands - Radial Feed Seismic Anchoring/Construction Outdoor Service Telephone Green 5 Mils C57.12.28-1995 Paint Standard Undercoating Tank Base + 1" Up Side Shot Blasting Of Tank Vacuum/Upper Filter Press Connection - 1" Plug 1" Drain Valve with 3/8" Sampler Valve MONITORING SHIPPING TANK TERMINATION TEST Dial Type Thermometer Provisio Liquid Level Gauge Pressure Relief Valve Vacuum Pressure Gauge Provisions FOB Destination Prepaid Formed Base with Jacking Provisions Stainless Steel Ground Pads Cork Neoprene - All Gauge Gaskets Standard Handhole - Bolted Sealed Tank Design 15 PSI Tank Design Standard Welded on Flat Tubular Radiators Three Point Hinged Door on Compartment Approval of Certified Test Report Required Before Shipment Price Item 001 : $43 720 USD Net Each Transformer COMMENTS AND EXCEPTIONS: Quotation is based on the .above Bill of Material only. 5.1.A - A three-legged, stacked core shall be provided by ABB, Inc. 5.6.6 - A bolted manhole cover shall be provided. The transformer tank cover shall be welded assembly. 6.2 & 7.0 - Not applicable per spec page 11 of 16. Lead Times: Drawing Submittal A-6 Weeks after receipt of order. Approval Order (Shipment) :10-12 Weeks after return of approved drawings. Firm Order (Shipment) :10-12 Weeks after receipt of order. Transformers are designed, built and tested to ANSI/IEEE C57 Transformer Standards. No other Codes/Standards apply (NEC, NESC, etc.) unless noted on quote. "GENERAL TERMS AND CONDITIONS OF SALE** This quotation is effective for 30 days from 10/31/2003, unless otherwise authorized by ABB. Unless stated otherwise in this quotation, the following terms and conditions of sale will apply 1. FOB Destination Prepaid 2. Payment is due net 30 days from invoice date. 3. Terms and conditions of sale are based upon ABB Inc. General Terms and Conditions of Sale. 4. Escalation: Prices will remain firm for 180 days from date of receipt of order. After 180 days, prices will be escalated 0.5% for each additional 30 day period, or portion thereof, from the date of the order to the date of the shipment, unless other conditions have been previously negotiated. We appreciate the opportunity to quote on this business. The ABB Small Power Transformers has had many years of experience building reliable, high quality transformers and we look forward to supplying this equipment. If there are any questions regarding this quotation or any other matter relating to this job please call me at your convenience. Quoted lead times are based on current production levels. Actual lead times are dependent on available production space at time of order entry and/or release to manufacturing. TRANSFORMER PERFORMANCE DATA ABB Quote Nb.: DIR03199 Item No.: 001 KVA: 3750 Impedance: 6.00 Cooling Medium: Air Rise: 65 Stated Values Are Guaranteed Losses *LOAD I% EFFICIENCY INO-LOAD LOSS (LOAD LOSS 25 99.46 ( 3,420 1,690 50 ( 99.46 ( 3,420 6,770 75 99.34 3,420 15,230 I100 I 99.19 I 3,420 27,080 EFFICIENCY IS CALCULATED AT UNITY POWER FACTOR REGULATION WITH A LAGGING POWER FACTOR % LOAD I (POWER FACTORI 100 1 100 1 0.88 95 2.67 90 3.35 85 3.84 80 :: 4.23 75 4.54 70 4.81 1 REGULATION BASED ON: % X = 5.9510 % R = 0.7005 s X/R = 8:4957 % Fe = 0.0912 Hertz: 60 Cooling Class: OA TOTAL LOSS 10,190 18,650 30,500 %EXCITING % VOLTS I NO LOAD LOSS CURRENT 80 I 2,052 � 0.23 90 2,736 ( 0.41 100 3,420 0.73 105 4,104 1.19 110 I 5,130 ( 2.74 POWER FACTOR 1.00 ( 0.95 0.90 0.85 ( 0.80 *LOAD 1% EFFICIENCY116 EFFICIENCY1% EFFICIENCY % EFFICIENCY % EFFICIENC�fj 25 1 99.45 1 99.42 1 99.39 99.36 99.32 50 1 99.45 1 99.43 99.39 99.36 99.32 75 1 99.34 ( 99.30 99.26 99.22 99.17 100 I 99.19 I 99.15 I 99.10 I 99.05 I 98.99 ' Ox '1--- -►; r �F' 0� ma SPECIFICATION NO. TR2-2003 PADMOUNT TRANSFORMER CITY OF VERNON LIGHT AND POWER SEPTEMBER 15, 2003 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 1.0 SCOPE Supplier shall furnish all work for providing three-phase, deadfront, radial, self cooled, padmounted transformers for use on the City of Vernon's underground distribution system. The transformer sizes that the City requires are listed in Attachment A. This list does not preclude the possibility of ordering voltage and KVA ratings not listed under this specification. 2.0 APPLICABLE STANDARDS A. The transformers shall conform to the applicable sections of the following standards to the extent referenced in this Specification, and as amended to the date of this Specification which, by reference, are included as part of this Specification. 1. C57.12.00 IEEE Standard General Requirements for Liquid - Immersed Distribution, Power, and Regulating Transformers. 2. C57.12.26 Requirements for Padmounted Compartmental - Type, Self Cooled, Three -Phase Distribution Transformers for Use with Separable Insulated High Voltage Connectors, High Voltage . 34500GrdY/19920 Volts and Below, 2500 kVA and Smaller. 3. C57.12.28 Padmounted Equipment —Enclosure Integrity. 4. C57.12.90 IEEE Standard Test Code for Liquid -Immersed Distribution, Power, and Regulating Transformers and IEEE Guide for Short -Circuit Testing of Distribution and Power Transformers. 5. C57.91 Guide for Loading Mineral -Oil -Immersed Overhead and Padmounted Transformers Rated 500 kVA and Less with 650C or 550C Average Winding Rise. 6. C57.92 Guide for Loading Mineral -Oil -Immersed Power Transformers Up to and including 100 MVA with 650C or 550C Average Winding Rise. Y, 7. C57.106 IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment. B. In the event of conflict between the codes and standards and this Specification, Supplier shall notify City of Vernon Light and Power Department and secure a written clarification before proceeding with the work. 3of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 3.0 SERVICE CONDITIONS 3. 1. Environment A. The transformers shall perform in accordance with all provisions of the Specification while subject to the service conditions specified in ANSI/IEEE C57.12.00. B. The transformer shall be suitable for 30 years of use -on the City of Vernon's electric system when installed in accordance with the service conditions set forth in ANSI/IEEE C57.12.00-1987, Section 4.0, in its entirety. 3. 2. Seismic and Impact Loading A. Before and during installation, the transformers shall withstand, without damage, rough handling such as bouncing on a truck when filled with insulating medium and impacting against or upon rigid structures at speeds up to five feet per second, and being lifted by two bosses or lifting second, and being lifted by two bosses or lifting bolts, at any angle. Following these conditions, the transformers shall be capable to being energized without a pre- operational test. B. After installation and during the 30-year life of transformer, transformer will be subject to occasional earthquake motions (0.2g horizontal and 0.13g vertical) along with significant vibrations from traffic and from adjacent equipment. 3.3 Pre -installation Inspection The City of Vernon will, at its discretion, provide a pre -installation inspection of each transformer. 3.4 Operating Duty For its 30-year life, each transformer shall be suitable for operation under short circuit conditions as stated in ANSI/IEEE C57.12.00-1987, Section 7.1. 4of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 3.5 Shi in A. All transformers shall be shipped to the City of Vernon, Soto Yard located at 2800 Soto Avenue, Vernon, CA 90058. Supplier's price shall be F.O.B. Soto Yard. B. Transformers will be delivered on a flatbed truck for side unloading by forklift at ground level. C. Delivery will be scheduled Monday through Thursday 7:00 a.m. to 3:00 P.M. Supplier shall provide City with 48 hours notice prior to delivery. 4.0 RATINGS 4.1 Sizes The transformers shall be sized as shown in Attachment A. 4.2 High Voltage Ratings Transformers shall be 60 Hz with BIL ratings as shown in the table below. ••c��ww�11ml dnu toonnecior Hi Transformer High -Voltage Ratings (volts) Single High-VoRage 7200 16340 Series -Multiple High - Voltage 7200 x 16430 and Electrical Characteristics Electrical Characteristics of the Completely Assembled I High -Voltage Connectors'' High -Voltage Rating 2, Minimum Phase -to -Ground /Phase-to- BIL3' (kV) I Phase (kV) 75 95 75 x 95 8.3/14.4 8.3/14.4 8.3/14.4 60-Hz dry BIL one minute (kV) withstand (kV) 95 34 95 34 95 ,. I 34 2 For complete connector rating, see ANSI/IEEE 386. 2 Transformers are suitable for connectors with phase -to -ground or phase-to-ground/phase-to-phase high -voltage ratings as listed. 3 Arrester coordination may require higher BIL on multiple connection than indicated to achieve a minimum protection level of 20%. 5of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 4.3 Low Voltage Rating The secondary voltage shall be one of the following. The basic insulation level (BIL) of the secondary voltage shall be 30 M 480Y/277 208Y/120 4.4 Configuration All transformers shall be Delta -Wye configured with low voltage neutral having a fully insulated Xo bushing with a removable ground strap. 4.5. Impedances Transformer impedance shall not be less than those shown in the table below. All transformer testing to determine transformer impedance shall be based on the base kVA rating of the transformers at the 55 degree or 65 .degree temperature rise. The transformer impedances shall be shown on the transformer nameplate. Minimum Transformer Impedance KVA %Z 300-500 4.0 750-2500 5.75 3750 6.00 5.0 CONSTRUCTION FEATURES 5.1 Coil and Core Construction A. The transformer core shall be of high efficiency rectangular wound core designed in five -leg or triplex configurations. The core shall be made from one of two processes: single -turn laminations of high quality, grain oriented silicon core steel or amorphous core (Le metallic glatses metal). B. The transformer coils shall be designed to maintain their nameplate KVA rating throughout the normal temperature range of operation which shall be 65°C (80°C hot spot). All materials used shall be of the 65°C, 800C hot spot class. All materials shall be thoroughly tested for compatibility with all transformer components before being assembled. The primary coil shall 6of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS be manufactured from heavy varnish or paper insulated aluminum or copper wire. The secondary coil shall be manufactured from full width aluminum strip whose edges are finished to prevent burrs and insulated with epoxy -diamond paper between layers of the conductor. 5.2. Insulating Fluid A. The transformer insulating fluid shall be standard electrical grade mineral insulating oil. The insulating oil shall be tested and degassed to assure a chemically inert oil. The padmount transformers shall be furnished with oil which meets the requirements specified in ASTM Standard D 3487 for mineral insulating oil, except that the DBPC content (% by weight) shall not be less than 0.15. The insulating oil in the equipment shall conform with ANSI C57.106. B. All transformer oil shall be tested for polychlorinated biphenyl's (PCBs) per ASTM D4059 and certified as having no detectable levels of PCB. 5.3 Taps and Changers A. The transformers shall be furnished with full capacity high -voltage taps. The tap changer shall be clearly labeled to reflect that the transformer must be de -energized before operating the tap changer as required in Section 3.3 of ANSI C57.12.26. Padlocking provisions are available for lever or hotstick operable handles. Tap changer operating mechanisms shall be permanently identified to show "De -energized Operation Only". Decals and stencils are not acceptable. The unit shall have one of the following tap configurations: Two - 2%2% taps above and below rated voltage such as the following: VOLTAGE FULL CAPACITY TAPS 16,340 17,200/16,770115,910/15,480 7,200 7,560/7,380/7,020/6,840 r. B. The tap changer position indicating nameplate shall have numerals or letters that are clearly legible and of permanent quality. Decals and stencils are not acceptable. 7of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 5.4 Gauges A. All transformers shall have a dial -type, magnetic, oil level gauge to provide a positive means of determining the required oil height. The preferred location of the gauge is above the switch handles, to ensure the switch remains under oil. B. All transformers shall have a dial -type, magnetic, temperature gauge to provide a positive means of determining the transformer temperature. The required location of the gauge is in the low voltage compartment above the bushings. 5.5 Drain and Replacement Provisions Insulating medium drain and replacement provisions shall be furnished as specified in ANSI C57.12.26. 5.6. Tanks and Terminal Compartment A. The transformer tanks, and all external appurtenances, shall be in accordance with ANSI C57.12.26. The overall dimensions and various appurtenances locations shall be found on each transformer per Attachments C and D. B. Transformers shall have bolted covers for all size transformers. C. The compartment depth shall be minimum in accordance with figure 7 of C57.12.26. A deeper compartment shall be provided for extended secondary bushings. The tank shall be of sufficient strength to withstand a pressure of 7 psig without permanent distortion. The following pressure relief devices are approved: 1. Qualitrol Model No. 202-030-001 2. Qualitrol Model No. 202-032-001. 5.7 Terminations Transformer bushings shall accommodate cable terminations in accordance with ANSWEEE 386, but shall be modified to provide the height requirements of these specifications as shown in Attachments C and D. 8of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 5.8 Nameplates A stainless steel nameplate shall be attached with non -corrosive hardware to the inside of the low voltage compartment door. The nameplate shall not be installed on the rear of the low voltage compartment area. Diagrams and numbers shall be of the size and quality such that they can be read from outside the compartment. In addition to the nameplate requirements shown in ANSI/IEE C57.12.00-1987, Section 5.12, the total weight, including oil, shall be indicated. 5.9 Coating A. Each transformer and terminal enclosure combination shall be painted a forest green color such as Dulux Bell Telephone Green No. 183-Y-546 (Munsell 7.5GY2.95/2.1) or City of Vemon-approved equivalent. The primary and finishing coats shall have a combined minimum dry -film thickness of three mils. Manufacturer shall furnish 1/4 pint of touch up paint for each transformer. B: The underside of each transformer shall be coated with an asphaltic :material or with City of Vernon -approved paint system. An epoxy coat which meets ANSI C57.12.28 is acceptable. 6.0 Loadbreak Switches 6.1 'Type A. Each transformer shall have a three-phase, self-contained, oil immersed, high voltage, loadbreak gang -operated sectionalizing switch. The switches shall be inside the transformer tank and be so located that current interruption occurs under oil. The loadbreak switches shall provide circuit connections as shown in Attachments C- and D. Operation of the switch shall be clockwise to close. B. The operating handle shall be located in the high voltage compartment and be suitable for hot stick operation. The position of the switch, whether open or closed, shall be clearly indicated. The handle shall be located in such a manner as to be identifiable with the associated circuit -transformer. Stencils or decals to indicate switch positions are not acceptable. 9of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 6.2 Interlocks The switch shall have an interlock which will prevent removal of fuses when the switch is in the closed position and also prevent the inserting of fuses when the switch is in the closed position. 6.3 Ratings The switches shall have the following ratings when completely assembled and installed in the transformers. A. Minimum Voltage Rating: 17,000 volts. B. Loadbreak Capability: 200 rms amperes at 17,000 volts and 0.6 power factor. C. Short -time current Rating: 10,000 rms symmetrical amperes for 15 cycles. D. Closing and Holding Current Rating: 10,000 rms symmetrical amperes for 15 cycles. E. There shall be no arcing time after the switch blades have traveled from the closed position to the fully opened position. 7.0 OVERCURRENT PROTECTION 7.1 High Voltage Protection A. Transformers shall be protected against overcurrent by means of a City of Vemon-approved externally replaceable fuses in the primary circuit. The fuses shall be suitable for hot stick operation and shall have a minimum of 50,000 rms symmetrical ampere interrupting rating. The fuses shall have City of Vemon-approved safety devices which prevent insertion directly into a fault. B. The fuses shall be a Bay-0-Net type oil immersed fuses in series with oil immersed current limiter type RTE ELSP current limiting backup fuse. The fuses shall have a safety device which prevent insertion directly into a fault. 10 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS C. The correct size of Bay-O-Net fuse for replacement shall be indicated by stencil or decal above the Bay-O-Net fuse as follows: "Caution: Use only RTE Bay-0-Net Type 353C "(10, 12, etc.)" " Amps" (25, 40, etc.) D. The following table lists the appropriate fuse sizes: Transformer Ratings KV KVA Rating FLA High Voltage Fuses4 BAYONET ELSP MINIMUM 0 16.34 300 15.5 11 4000353C10 354508OM51 M 4.00 500 15.5 18 4000353C10 354508OM51 M 4.00 750 15.5 26 4000353C12 3545125M61 M 5.75 1000 15.5 35 4000353C12 3545125M61M 5.75 1500 15.5 53 4000353C16 354515OM51 M5 5.75 2000 15.5 70 4000353C16 354515OM51 M5 5.75 2500 15.5 88 NONE NONE 5.75 .3750 15.5 132 NONE NONE 6.00 7.2 300 8.3 24 4000353C12 3543125M61 M 4.00 500 8.3 40 4000353C14 354308OM51M5 4.00 750 8.3 60 4000353C16 354320OM51 M 5.75 1000 8.3 80 4000353C17 3543175M51 M5 5.75 1500 8.3 120 NONE NONE 5.75 E. A minimum of 6 spare Bay-O-Net fuses shall be provided with each transformer order. For instance, if we order one 7.2 kV type 300 KVA transformer we require 6 spare fuses. If we order two such transformers, we require 12 spare fuses. 7.2 Low Voltage Protection Low voltage overcurrent protection is not required. 4 Cooper (Type Bay-O-Net and Current Limiting ELSP) 5 Two parallel fuses per phase 11 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 8.0 BUSHINGS, BUSHING WELLS AND PARKING STANDS 8.1 Low Voltage Bushings A. Transformers shall have bushings which conform to ANSI Standard C57.12.26. On "Wye" connected transformers, the neutral shall be connected to a fully insulated bushing. An additional tank ground pad with removable neutral bushing ground strap shall be provided and suitably sized for the short circuit current rating of the transformer. B. External spade terminals shall have a heavy tin coating process. If the terminal extension is not an integral part of the bushing, it shall be securely pinned to the stud. C. External spade terminals with six holes and more shall be furnished with additional support straps, designed by the manufacturers, at the end farthest from the tank wall without interfering with the use of any of the holes. Each extension pad shall be fully rated for the maximum ampacity of the transformer. Refer to the table below for the number of terminal holes. KVA Ratings Low -Voltage Ratings (Volts) Number of 9/16" hole cable positions 75-300 ALL 4-6 500 ALL 8 750-1500 ALL 12. 2000-2500 ALL 14 3750 ALL 16 8.2 High Voltage Bushing Wells Transformers shall be provided with three City of Vemon-approved, 17 kV high voltage bushing wells rated 95 kV BIL, marked and located as shown in Attachments C and D. 8.3 Parking Stands Transformers shall be equipped with non -load break parking stands, ESNA No. 151-PS or City of Vemon-approved equivalent. They shall be located as shown in Attachments C and D and in accordance with ANSI Standard C57.12.26. 12 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 9.0 IDENTIFICATION 9.1 Stencils & MSDS A. All bushings shall be identified by yellow paint stencils, a minimum of one inch high, on the tank wall adjacent to the bushings. See Attachments, C and D. B. A removable identification tag or sticker which shall be legible at time of receipt shall be attached to the exterior of the terminal compartment. The tag or sticker shall indicate the name of the manufacturer, serial number, kVA and voltage ratings. C. In addition to the nameplate information called for in ANSI C57.12.00, the nameplate shall identify each winding as to whether it is made of copper or aluminum. D..- The vendor shall be required to provide all applicable Material Safety :. Data Sheets with all transformer orders. 10.0 ADDITIONAL REQUIREMENTS 10.1 Barriers A barrier shall separate the high -voltage section from the low voltage section in the terminal compartment. Barrier shall be of sufficient strength to prevent deformation which may reduce the required clearances to various components. 10.2 Conduit Entrance When specifically requested in the transformer table below, a 2 %2 inch conduit entrance hole, with a cover which is removable only from the inside, shall be provided in the center of the low voltage sill. 13 of 16. CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 10.3 Terminal Arrangements Terminal arrangements shall be as shown in Attachments C and D. 10.4 Access to Terminal and Switching Compartments A. Transformers shall be provided with hinged doors for access to the terminal and switching compartments. Access to the high voltage portion of the terminal and switching compartment shall be possible only after access has been gained to the low voltage. B. The low voltage compartment door shall be further secured by means of a captive and recessed Y2 inch pentahead bolt. A blind bolt hole shall be provided. Bolts shall be corrosion resistant and the design shall minimize the possibility of a misalignment and cross -threading. Design of the bolting, padlocking and three-point latching provisions shall be coordinated such that, only after the padlock and bolt have been removed, shall it be possible to open the low voltage compartment door. 11.0 TESTS 11.1 General A. Transformer tests shall be performed as specified in ANSI Standard C57.12.00. These test reports shall be provided to the City prior to shipping. The City will not receive any transformers without the required test reports. B. Units shall comply with routine test requirements of ANSI and certified test reports shall be fumished. The vendor shall provide with returned bids all applicable documentation of compliance with ANSI design tests. C. The following data shall be submitted with each transformer order: a. Guaranteed maximum no load (excitation) loss at rated voltage and 110% voltage in Wafts. b. Guaranteed maximum load loss in Watts at rated voltage and 110% voltage. c. Guaranteed maximum total loss in Watts at rated voltage and 110% voltage. 14 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS d. Exciting Current in percent at rated voltage and 110% rated voltage. e. Percent impedance on base voltage and at the maximum temperature rise. If the transformer is a 55/65 degree Celsius transformer rise, the percent impedance shall be at 65 degree Celsius. f. Efficiencies shall be provided at loading levels of 100%, 75%, 50%, and 25%. g. Regulation at rated load @ 80% and 100% Power Factor. h. Two sets of outline drawings showing dimensions, weight, gallons of oil, gauge of steel in tank walls, cover, bottom, and cooling radiators and description of accessories. After order is awarded, the vendor shall submit FINAL drawings. 12.0 OPERATING PERFORMANCE 12.1 General Thp Apparatus shall perform in accordance with the conditions set forth in this Specification. 13.0 BID EVALUATION 13.1' Total Ownership Cost Purchase of transformers shall be evaluated by lowest total ownership cost. The formula to evaluate Total Owning Cost (TOC): TOC = C + $4.53/W (PNL in Watts) + $1.1/W (PLL in Watts) Where TOC is the total ownership cost in dollars, C is the initial cost in dollars, PNL is the guaranteed maximum no-load loss in watts, and PLL is the guaranteed maximum load loss in watts For the determination of the award for the transformer order(s), City will consider all bids within 5% of the lowest Present Value Cost of Transformer to be economically equivalent. The City of Vernon realizes it is impossible to accurately predict economic conditions over the evaluation period of 30 years. 15of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 13.2 Delivery A delivery date of 16 weeks ARO or less is required. Failure to quote a delivery schedule within this period may disqualify the bid. 14.0 DOCUMENTATION 14.1 For Bid Evaluation Bidders shall furnish the following in their bid proposals: 1. Transformer unit price, F.O. B. Soto Yard. 2. Guaranteed maximum no-load loss at rated voltage in watts. 3. Guaranteed maximum load loss in watts at rated voltage and WA. 4. Percent impedance on rated voltage tap. 5, Two sets of dimension and outline drawings. 14.2 For Delivery Supplier shall furnish MSDS and certified test reports and drawings, as listed in Section 11.1 in this Specification one month before transformers are shipped. These documents shall be submitted to: City of Vernon Utilities Department 4305 Santa Fe Avenue Vernon Ca, 90058 Phone: (323) 583-8811 Attention: Ramon Z. Abueg Assistant Director of Engineering and Operations 16 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS Attachment A. Transformer Sizes 3 500 7.2 277/480 2 750 7.2 277/480 1 150 16.34 120/208 3 300 16.34 277/480 1 500 16.34 277/480 3 750 16.34 277/480 3 1000 16.34 277/480 2 2500 16.34 277/480 1 3750 1 16.34 277/480 ONE CIRCUIT (RADIAL) LINE A CL AY-O-NET TWO CIRCUIT (LOOPED) LINE A moo--- LINE B CL BAY-O-NET VERNON LIGHT AND POWER EQUIP►dEW- SPECIFICATION TR2 ADDITIONAL CIRCUIT CONNECTIONS 11/2/01 NO REVISION DATE APPV'D BY ATTACHMENT B 70" MAX RADIATORS MAY EXTEND BEYOND THE DIMENSIONS SHOWN x z a o - r- � PLAN �— SEE NOTE 2 -C EXTERNALLY REPLACEABLE CL FUSES I - J NAMEPLATE o uo x ►+uo Hi H2 3 TRANS SW. O O v1 x x p 1 3 O O 0 2 C9 Z H1 H2 H3 a 2-1/2" CONDUIT HOLE (SEE NOTE 3) -- 40-1/2" .MIN 22" MIN. ELEVATION BAY-O-NET FUSE SCHEMATIC DIAGRAM NOTES: 1. ALL DIMENSIONS AND CLEARANCES SHALL CONFORM WITH ANSI C57.12.26. 2. CURRENT LIMITING FUSES INTERLOCKED WITH TRANSFORMER SWITCH. x , x x x 0 1 2 3 3. 2-1/2" CONDUIT HOLE SHALL BE LOCATED IN THE CENTER (BOTH HORIZONTALLY AND VERTICALLY) OF THE LOW VOLTAGE CABINET SILL. VERNON UTILITIES DEPARTMENT EQUIPMEW: SPECIFICATION TR2 ONE -CIRCUIT PADMOUNTED TRANSFORMERS 75 THROUGH 500 KVA 0 10/30/01 AV 40 REVISION DATE APPV'D BY ATTACHMENT C 750 THROUGH 3756 KVA —B 28" MIN -� - Ir— 22" MIN PLAN EXTERNALLY REPLACEABLE CL FUSES 0 01 I o uo uo H 1 H2 F43 cnx x Q p 1 3 z O O xo W x2 ca z Y Ir 0-- ELEVATION `- NAMEPLATE TRANS SW. RADIATORS MAY EXTEND BEYOND THE DIMENSIONS SHOWN DIM 750, 1000 & 1500 KVA 2000 AND 3750 KVA A 77" MAX 87" MAX B 80" MAX 85" MAX C 76" MAX 90" MAX D 26" MIN 26" MIN E 42" MIN 42" MIN SECONDARY BUSHING LOCATIONS TO CONFORM WITH ANSI STANDARD C57.12.22 — FIG. 3 2-1/2" CONDUIT HOLE (SEE NOTE 3) 6- 6-3 02-1 /2" CONDUIT HOLE ELEVATION NOTES: 1. ALL DIMENSIONS AND CLEARANCES SHALL CONFORM WITH ANSI C57.12.26. 2. CURRENT LIMITING FUSES INTERLOCKED WITH TRANSFORMER SWITCH.' 3. 2-1/2" CONDUIT HOLE SHALL BE LOCATED IN THE CENTER (BOTH HORIZONTALLY AND VERTICALLY) OF THE LOW VOLTAGE CABINET SILL. VERNON LIGHT AND POWER EQUIPMENT: SPECIFICATION TR2 ONE -CIRCUIT PADMOUNTEC TRANSFORMERS 1 9/11/03 ,►L 750 THROUGH 3750 KVA NO REVISION DATE APPV'D BY ATTACHMENT D SUPPORTING DOCUMENTS 1 EQUIPMENT PURCHASE CONTRACT 2 THIS AGREEMENT is made, entered into and executed in 3 duplicate originals, either copy of which may be considered and used as 4 the original hereof for all purposes, as of this 2,JS day of November, 5 2003, in the City of Vernon, County of Los Angeles, California 6 BY AND BETWEEN THE CITY OF VERNON (hereinafter referred to as 7 the "City") 4305 Santa Fe Avenue 8 Vernon, CA 90058 9 AND PAUWELS TRANSFORMERS, INC. (hereinafter referred to as 10 "Pauwels") One Pauwels Drive 11 Washington, MO 63090 12 RECITALS 13 WHEREAS, on October 14, 2003, the City requested proposals 14 or bids for nine (9) bid items totaling nineteen (19) Padmounted 15 Distribution Transformers (Bid No. 1429) needed by the City's Light & 16 Power Department; and 17 WHEREAS, the City is permitted to accept or reject any or 18 all quotations received on the bid items; and 19 WHEREAS, on or about November 4, 2003, the City received 20 various proposals for the sale of Padmounted Distribution Transformers 21 identified in Bid No. 1429, with each of the nine bid items quoted 22 separately; and . 23 WHEREAS, on October 30, 2003, Pauwels, through its 24 representative Pacific Utilities Supply Company, submitted a bid; and 25 WHEREAS, on November 4, 2003, the City opened the bid 26 submitted by Pauwels, as well as other bids for the items identified 27 in Bid No. 1429; and 28 WHEREAS, the City desires to purchase the following bid r i 1 items from Pauwels: two (2) 750 KVA 7.2 277/480 Padmounted 2 Transformers; one (1) 500 KVA 16.34 277/480 Padmounted Transformer; 3 three (3) 750 KVA 16.34 277/480 Padmounted Transformers; and, one (1) 4 3750 KVA 16.34 277/480 Padmounted Transformer, for a total of seven 5 (7) Padmounted Transformers. 6 NOW, THEREFORE, THE PARTIES HERETO DO MUTUALLY AGREE AS SET 7 FORTH HEREIN: 8 1. Purchase. Pauwels agrees to sell and deliver to the 9 City a total of seven (7) Padmounted Transformers referenced above 10 pursuant to City of Vernon Specification No. TR2-2003, as identified 11 in Pauwels' October 30, 200*3 bid and which meet the specifications 12 contained in City of Vernon Bid No. 1429, dated October 14, 2003 13 (collectively referred to as the "Bid Documents"). A copy of the Bid 14 Documents are attached hereto as Exhibit "A" and incorporated herein 15 by reference. 16 2. Time of Performance. Pauwel's performance shall 17 commence upon the full execution of this Contract and shall be 18 completed by Pauwels within 10 weeks after receipt of order. 19 3. Price. The City agrees to purchase seven (7) 20 Padmounted Transformers from Pauwels for the total sum of Seventy -Nine 21 Thousand Nine Hundred Fifty -Four Dollars and No Cents ($79,954.00). 22 This price includes freight and excludes sales tax. 4. Delivery. Consistent with the Bid Documents, Pauwels 23 ' 24 agrees to deliver the seven (7) Padmounted Transformers on a flatbed truck for side unloading by forklift at ground level to the Soto Yard 25 at 2800 Soto Avenue, Vernon, California. Pauwels shall notify the 26 City 48-hours prior to delivery to make arrangements for gates to be 27 opened. Delivery shall be scheduled for Monday through Thursday 28 -2- 1 between the hours of 7 a.m. and 3 p.m. 2 5. Warranties. Pauwels warrants title to the Padmounted 3 Transformers purchased hereunder and any part thereof to be free of 4 any claim or any security interest, lien or any encumbrance. Pauwels 5 also warrants that the Padmounted Transformers will be delivered new 6 and shall be free from defects. Pauwels shall provide, at a minimum, 7 a one (1) year labor and material warranty to begin upon acceptance of 8 the Padmounted Transformers by the City. All manufacturers' 9 warranties, any warranties typically provided by Pauwels and any other 10 warranties made applicable by law shall apply to the City's purchase 11 of the Padmounted Transformers. 12 6. Governing Law. The validity, interpretation and 13 performance of this Contract shall be controlled and construed under 14 the laws of the State of California. 15 7. Forum Selection. Any action brought relating to this 16 Contract shall be brought and held exclusively in a State Court in the 17 County of Los Angeles, California. 18 8. Notices. Notices to the parties, unless otherwise 19 requested in writing, shall be sent to: 20 City: THE CITY OF VERNON 21 ATTN: DOLORES FONSECA PURCHASING ASSISTANT 22 4305 SANTA FE AVENUE VERNON, CA 90058-0805 23 Pauwels: PAUWELS TRANSFORMERS, INC. 24 ATTN: DIANA KALLMBAH, ACCOUNT SPECIALIST ONE PAUWELS DRIVE 25 WASHINGTON, MO 63090 26 9. Risk of Loss. 27 Title and risk of loss or damage shall pass to the City and 28 delivery shall be deemed to be complete upon delivery FOB jobsite or -3- 1 upon moving into storage at the City's request, whichever occurs 2 first. 3 10. Attorneys' Fees. 4 In the event that it becomes necessary for either party to 5 this Agreement to enforce any of the provisions of this Agreement, the 6 parties agree that a court of competent jurisdiction may determine and 7 fix reasonable attorney's fees to be paid to the successful litigant. 8 IN WITNESS WHEREOF, the parties have caused this Agreement 9 to be executed by and through their authorized officers on the date, 10 month and year first written above. 11 CITY OF VERNON 12 13 By: LEONIS C. MAL RG, Mayor 14 ATTEST: 15 16 BRUCEV.. MMALKENHORST, City Clerk 17 APPROVED AS TO FORM: 18 19 ERIC T. FRESCH, Acting City Attorney 20 PA LS TRANSFORMERS, INC. 21 22 By: pr 23 24 Title: 25 26 By: 27 28 Title: C{ IEE RtVi RXIAL C)FFSCER -4- vrSl I QDJAJA L- REQUEST FOR QUOTATIONS NOT A PURCHASE ORDER DIRECT ALL INQUIRIES TO: CITY PURCHASING AGENT TELEPHONE (323) 583-8811 CITY OF VERNON, CALIFORNIA PURCHASING DEPARTMENT CITY HALL 4305 Santa Fe Ave. - Vernon, California 90058 TO: PAUWELS TRANSFORMERS c/o Bernie Schweigert Pacific Uti+ities Supply Co., —2475 Estand Way Pleasant Hill, CA 94523 FOR CITY USE ONLY QUOTATION NO. 1429 DATE MAILED 10/14/03 REC'D BY CITY OPENEB'1 l I AU/0 3.2;Q7, Please quote hereon the lowest net price you can fumish the articles or services specified below. Quote on each item separately. Bidder may qualify quotations as 'all or none' by stating so on body of form. City reserves the right to accept or reject quotations received on any or all items. In order to maintain their name on City's Bidder File, Vendor should return this form whether a price is quoted or not. QUANTITY DESCRIPTION DIET UNIT PRICE TOTAL Padmount Transformers as per attached specification No. TR2-2003, dated September 15, 2003. KVA PRIMARY VOLTAGE KV SECONDARY VOLTAGE 3 500 7.2 277/480 _.. 00 A32X 171 OO 2 750 7.2 277/480 gA343. Ct7 1.8�-1(p Da - 1 150 .<. 16.34 120/208 IN iQL Iq OD 3 300 16.34 277/480 OD 1 500 16.34 277/480 A 0- M _-Z4&q 3 750 16.34 277/480 9=02 6D_ 7q-TY X — 3 1000 16.34 277/480 10518 CZ 31Oily 00 2 2500 16.34 277/480 A313 Z 3?0-* 07) 1 3750 16.34 277/480 .Z031 Gb 03_I OU -- Deliver on flatbed truck for side unloading by forklift at ground level. Please notify RMI-US at (323) 589-9498 (48) hours prior to delivery. If you have any questions please contact Jose Lugo at (323) 583-8811, ext. 276. ---------PLEASE NOTE ---------- Bid number must be indicated on the outside of the envelope; otherwise, bid will not be accepted. IF INSUFFICIENT SPACE PROVIDED ABOVE FOR PROPOSAL. ATTACH RIDER OR SUPPLEMENT. CASH DISCOUNTS QUOTED FOR PERIODS OF LESS THAN 30 DAYS WILL NOT BE CONSIDERED WHEN ORDER IS AWARDED. BIDS RECEIVED IN RESPONSE TO THIS REQUEST FOR QUOTATION WILL BEOPENED IN CITY PURCHASING AGENTS OFFICE ON THE DAY OF 20 AT nA NOTE: Quote prices exclusive of Sales Tax and Excise Taxes. r A. Indicate Sales Tax in this space $...... N.1A.................................................... B. Indicate Excise Tax in this space$...Nl.A.......................................... B. Above quotations subject to Cash Discount of..NJ .................................... . %, F.O.B... D NADAN.......................................................... C. To be delivered to CITY OF VERNON at... 8.".10....vir g.. JIRO ..................................................................................................................... We (1) agree to furnish above in r—J? j3 W..........days from receipt of purchase order at prices specified. n FOR......... UW.F....5.... .................................... -7'. F Name 0&�1/. DATE.....Q�l(�b............................ SIGN HERE ......... -....0), . ..................................................... t MAIL TO PURCHASING DEPT. ,m A& 0 WM 9M �iriER'Cal LS C"R BUSIr-JESS P'AUWELS TRANSFORMERS INC. Quotation Number: P102011 Customer: CITY OF VERNON PURCHASING DEPT 4305 SANTA FE AVENUE VERNON, CA 90058 Attention: PURCHASING DEP Fax: 323-826-1425 Reference: QUOTATION NO 1429 Date: 10/31/2003 Cust. Code: VERN01 Region: 0400 We are pleased to present our quotation for three phase transformers with the accessories according to the attached bill of material(s) General Conditions: Prices: Firm for the duration of the contract. Validity: 30 days from the date of quotation. Taxes: Federal, state, local or any other taxes are excluded. Freight: Prepaid and Allowed, F.O.B. Destination Payment: 30 Days Net Payment Terms Warranty: Standard, 12 months from the date of installation, but not to exceed 18 months from the date of delivery. Any design dimensions, unless otherwise specified, are for indication only, and are not binding. This quotation is subject to Pauwels' Terms and Conditions of Sale, which are available upon request. Any deviation from the attached bill of material(s), before or after receipt of order, may affect price and delivery. The quoted ship weeks will go into effect after all outstanding technical matters have been resolved. Ship weeks are based on plant loading at time of quotation. Please verify ship weeks when placing an order. Please reference our quotation number on all purchase orders and correspondence. We will be pleased to provide you with any additional information that is required. Thank you for your inquiry, and we look forward to working with you in the future. Sincerely, PAUWEIS TRANSFORMERS, INC. -- Diana Kallmbah Account Specialist Utility Sales (636) 239-9300 x345 cc: PACIFIC UTIL Marc Schillebeeckx Vice President Sales & Marketing Utility / Industrial Sales (636) 239-9300 x349 12 A W ENERCY IS 04JR BL)SINBSS RAUWELS TRANSFORMERS INC. Quotation Number: P102011 Customer: CITY OF VERNON PURCHASING DEPT 4305 SANTA FE AVENUE VERNON, CA 90058 Attention: PURCHASING DEP Fax: 323-826-1425 Quotation Comments: TEST REPORTS ARE SENT AT TIME OF INVOICING. Date: 10/31/2003 Cust. Code: VERN01 Region: 0400 RAUWELS TRANSFORMERS INC. BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 01 Customer Line No.: Quantity: 3 Unit Price: $7,739.00 Extended Price: $23,217.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 500 kVA Model #: ZA050072E480007 Mineral Oil Immersed Cooling Class: OA Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 7200 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 75 kV Secondary BIL Rating: 30 kV High Voltage Taps: B Taps - Two 2.5% Taps below Nominal and Two 2.5% Taps above Nominal No Load Loss: 543 Watts Load Loss: 3302 Watts Total Loss: 3845 Watts Impedance: 4.17 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/ 8 Hole Aluminum H Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C14), Plastic Dripshield (), Spare bayonet fuses (2 sets) PRCLF (3543080M51M) Accessories: Pressure Relief Valve Qualitrol 202-030-01, Drain plug Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint, Coal Tar Under Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by FMC on 10/31/2003 rig PA'sUNWELS EM IS OUR BLMNESS PAUWELS TRANSFORMERS INC. BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 02 Customer Line No.: Quantity: 2 Unit Price: $9,238.00 Extended Price: $18,476.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 750 kVA Mineral Oil Immersed Model #: ZA075072E480010 Cooling Class: OA T Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 7200 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 75 kV Secondary BIL Rating: 30 kV high Voltage Taps: B Taps - Two 2.5% Taps below Nominal and Two 2.5% Taps above Nominal No Load Loss: 665 Watts Load Loss: 5316 Watts Total Loss: 5981 Watts Impedance: 5.75 % Tank Enclosure. Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel HV-LV Barrier Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/12 Hole Brass J Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C16), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (35432001451M) Accessories. Pressure Relief Valve Qualitrol 202-030-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color. GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards. Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment. SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PTINC on HY31/2003 PAUWELS TRANSFORMERS INC. le as PANUNWELS BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 03 Customer Line No.: Quantity,: 1 Unit Price: $4,819.00 Extended Price: $4,819.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 150 kVA Model #: ZA015163E200001 Mineral Oil Immersed Cooling Class: OA Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 16340 Delta volts Secondary Voltage: 20SY1120 volts Primary BIL Rating: 95 kV Secondary BIL Rating: 30 kV High Voltage Taps: S Taps - 15480/15910/16340/16770/17200 No Load Loss: 230 Watts Load Loss: 1354 Watts Total Loss: 1584 Watts Impedance: 4.18 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel HV-LV Barrier lsusnmgs: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary. Terminations: Epoxy Bushings w/Thread-on 4 Hole Aluminum H Soades Protection: Dual Sensing Bayonet Fusing (353C10), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545080M51M) Accessories: Pressure Relief Valve Qualitrol 202-037-01, Drain plug Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise suecified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PTWC on 10/31/M3 F PANUNWELS R A'& ENERGY IS CJI.1R BUSINESS PAt1WELS TRANSFORMERS INC. BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 04 Customer Line No.: Quantity: 3 Unit Price: $5,942.00 Extended Price: $17,826.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 300 kVA Model #: ZA030136E480004 Mineral Oil Immersed Cooling Class: OA Frequency: 60 Hz Avg. Winding Temp. 65 QC Primary Voltage: 16340 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 95 kV Secondary BIL Rating: 30 kV High Voltage Taps: S Taps - 15480/15910/l6340/16770/17200 No Load Loss: 375 Watts Load Loss: 2194 Watts Total boss: 2569 Watts Impedance: 4.05 % Tank Enclosure. Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel HV-LV Barrier Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Epoxy Bushings w/Thread-on 4 Hole Aluminum H Spades Protection. Dual Sensing Bayonet Fusing (353C10). Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545080M51M) Accessories. Pressure Relief Valve Qualitrol 202-037-01, Drain plug Liquid Level Gauge, Liquid Temperature Gauge Switching. L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards. Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PMC on 10/31/2003 r,B-WOUNruw�Ls PAUWEL5 TRANSFORMERS INC. BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 05 Customer Line No.: Quantity. I Unit Price: $7,469.00 Extended Price: $7,469.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 500 kVA Primary Voltage: Primary BIL Rating: High Voltage Taps: No Load Loss: Model #: Mineral Oil Immersed Cooling Class: Frequency: Avg. Winding Temp. 16340 Delta volts Secondary Voltage: 95 kV Secondary BIL Rating: S Taps - 15480/15910/16340116770/17200 ZA050163E480005 OA 60 Hz 65 °C 480Y/277 volts 30 kV Total Loss: 3818 Watts Impedance: 4.18 % Tank Enclosure. 526 Watts Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel HV-LV Barrier Load Loss: 3292 Watts Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/ 8 Hole Brass H Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C10), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545080MS1M) Accessories. Pressure Relief Valve Qualitrol 202-037-01, Drain plug Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards. Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment. SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by VMC on 10/31/2003 Mum LSlm�nllr�w_jw%p WW E 1VE'NERGY IS OUR BI,JSINE&S PAUWELS TRANSFORMERS INC. BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 06 Customer Line No.: Quantity: 3 Unit Price: $9,326.00 Extended Price: $27,978.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 750 kVA Model #: ZA075163E480001 Mineral Oil Immersed Cooling Class: OA Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 16340 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 95 kV Secondary BIL Rating: 30 kV High Voltage Taps: S Taps - 15480/15910/16340/16770/17200 No Load Loss: 671 Watts Load Loss: 4974 Watts Total Loss: 5645 Watts Impedance: 5.75 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts SecondaryTerminations: Porcelain Bushings w/12 Hole Brass J Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C12), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545125m6lm) Accessories: Pressure Relief Valve Qualitrol 202-037-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PMC on 10/31/2003 3 PAUWEL' n ..C;Y is OUR Emisi1Mess PAUWELS TRANSFORMERS INC. BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P 102011 Item Number: 07 Customer Line No.: Quantity: 3 Unit Price: $10,548.00 Extended Price: $31,644.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 1000 kVA Model #: ZA100163E480001 Mineral Oil Immersed Cooling Class: OA Frequency: 60 Hz Avg. Winding Temp- 65 °C Primary Voltage: 16340 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 95 kV Secondary BIL Rating: 30 kV High Voltage Taps: S Taps-15480115910/16340116770117200 No Load Loss: 830 Watts Load Loss: 6790 Watts Total Loss: 7620 Watts Impedance• 5.75 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/12 Hole Brass J Spades, Spade Support Protection. Dual Sensing Bayonet Fusing (353C12), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545125m61m) Accessories. Pressure Relief Valve Qualitrol 202-037-01, Drain valve w/Sampler _Liquid Level Gauge, Liquid Temperature Gauge Switching. L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color. GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards. Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment. SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by FMC on 10/31/2003 BILL OF MATERIAL Date: 10/31/2003 PAUWELS TRANSFORMERS INC. Quotation Number: P102011 Item Number: 08 Customer Line No.: Quantity: 2 Unit Price: $19,313.00 Extended Price: $38,626.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 2500 kVA Model #: ZA250163E480011 Mineral Oil Immersed Cooling Class: OA T Frequency: 60 Hz Primary Voltage: 16340 Delta volts Avg. Winding Temp. Secondary Voltage: 65 °C 480Y/277 volts Primary BIL Rating: 95 kV Secondary BIL Rating: 30 kV High Voltage Taps: S Taps - 15480/15910/16340/16770/17200 No Load Loss: Impedance: 1842 Watts 5.75 % Load Loss: 14966 Watts Total Loss: 16808 Watts Tank Enclosure. Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Sect Terminations: Porcelain Bushings w/14 Hole Brass J Spades, Spade Support Protection. None Accessories: Pressure Relief Valve Qualitrol 202-037-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching. L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color. GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment. SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PMC on 10/31/2003 P Aimilm sum MIIIIIIIIU"ELS AU WW BILL OF MATERIAL EN RCi1( ISOUR BU NE Date: 10/31/2003 Quotation Number: P102011 PAUWELS TRANSFORMERS INC, Item Number: 09 Customer Line No.: Quantity: 3 Unit Price: $6,591.00 Extended Price: $19,773.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 500 kVA Model #: ZA050072E480008 Mineral Oil Immersed Cooling Class: OA T Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 7200 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 75 kV Secondary BIL Rating: 30 kV High Voltage Taps: B Taps - Two 2.5% Taps below Nominal and Two 2.5% Taps above Nominal No Load Loss: 560 Watts Load Loss: 4696 Watts Total Loss: 5256 Watts Impedance: 4.13 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/ 8 Hole Aluminum H Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C12), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3543080M5M) Accessories: Pressure Relief Valve Qualitrol 202-037-01, Drain plug Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PTQ1C on 10✓31l2003 MEN �EL�ISO R BUSINESS P"AUWELS TRANSFORMERS INC. BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 10 Customer Line No.: Quantity: 2 Unit Price: $8,362.00 Extended Price: $16,724.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 750 kVA Model #: ZA075072E480011 Mineral Oil Immersed Cooling Class: OA Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 7200 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 75 kV Secondary BIL Rating: 30 kV High Voltage Taps: B Taps - Two 2.5% Taps below Nominal and Two 2.5% Taps above Nominal No Load Loss: 833 Watts Load Loss: 6102 Watts Total Loss: 6935 Watts Impedance: 5.75 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/12 Hole Brass J Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C16) Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3543200M51M) Accessories: Pressure Relief Valve Qualitrol 202-037-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.0GY3.29/IS), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PMC on 10l31/2003 Im as , PANUNWELS ENE r ISOUREXMNESS PRAUWELS TRANSFORMERS INC. BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P 102011 Item Number: 11 Customer Line No.: Quantity: I Unit Price: $4,430.00 Extended Price: $4,430.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 150 kVA Model #: ZA015163E200002 Mineral Oil Immersed Cooling Class: OA Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 16340 Delta volts Secondary Voltage: 208Y/120 volts Primary BIL Rating: 95 kV Secondary BIL Rating: 30 kV High Voltage Taps: S Taps - 15480/15910/16340/16770/17200 No Load Loss: 221 Watts Load Loss: 2010 Watts Total Loss: 2231 Watts Impedance: 4.19 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel HV-LV Barrier Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Epoxy Bushings w/Thread-on 4 Hole Aluminum H Spades Protection. Dual Sensing Bayonet Fusing (353C10), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545080M51M) Accessories. Pressure Relief Valve Qualitro1202-037-01, Drain plug Liquid Level Gauge, Liquid Temperature Gauge Switching. L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment. SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by FMC on 10131/2003 riPANUNum"WELS E ERA;Y IS OUR RUSINESS PAUWELS TRANSFORMERS INC. BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 12 Customer Line No.: Quantity: 3 Unit Price: $5,429.00 Extended Price: $16,287.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 300 kVA Mineral Oil Immersed Model #: Cooling Class: Frequency: Avg. Winding Temp. Primary Voltage: 16340 Delta volts Secondary Voltage: Primary BIL Rating: 95 kV Secondary BIL Rating: High Voltage Taps: S Taps - 15480/15910/16340/16770/17200 No Load Loss: 424 Watts Load Loss: 2756 Watts Impedance: 4.2 %n Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel HV-LV Barrier ZA030163E480005 OA 60 Hz 65 °C 480Y/277 volts 30 kV Total Loss: 3180 Watts Bushings: Radial Feed ANSI Specific Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Epoxy Bushings w/Thread-on 4 Hole Aluminum H Spades Protection: Dual Sensing Bayonet Fusing (353C10), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545080M51M) Accessories: Pressure Relief Valve Qualitro1202-037-01, Drain plug Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SWMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by FMC on 10/31/2003 re 12,� M LS ENERGY tS OUR BUSINESS PAUWELS TRANSFORMERS INC. BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P 102011 Item Number: 13 Customer Line No.: Quantity: 1 Unit Price: $6,546.00 Extended Price: $6,546.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 500 kVA Model #: ZA05016313480006 Mineral Oil Immersed Cooling Class: OA T Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 16340 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 95 kV Secondary BIL Rating: 30 kV High Voltage Taps: S Taps - 15480/15910/16340/16770/17200 No Load Loss: 573 Watts Load Loss: 4242 Watts Total Loss: 4815 Watts Impedance: 4.07 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 19 Inches, Pentahead Security Bolts Steel HV-LV Barrier umluugs: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/ 8 Hole Aluminum H Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C10), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545080M51M) Accessories: Pressure Relief Valve Qualitrol 202-037-01, Drain plug Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PMC on 10/31/2003 IVPAu"ES ENEROYISOURBUSINESS PAUWELS TRANSFORMERS INC. BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 14 Customer Line No.: Quantity: 3 Unit Price: $8,180.00 Extended Price: $24,540.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: Primary Voltage: Primary BIL Rating: High Voltage Taps: No Load Loss: 750 kVA Mineral Oil Immersed 16340 Delta volts 95 kV Model #: Cooling Class: Frequency: Avg. Winding Temp. Secondary Voltage: Secondary BR, Rating: S Taps - 15480/15910/16340V16770/17200 845 Watts Load Loss: 5922 Watts Impedance• 5.75 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions ZA075163E480002 OA 60 Hz 65 °C 480Y/277 volts 30 kV Total Loss: 6767 Watts Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/12 Hole Brass J Spades, Spade Support Protection: Dual Sensing Bayonet Fusing (353C12), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545125m61m) Accessories: Pressure Relief Valve Qualitro1202-037-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by PMC on 10/31r"3 PAft A.�,�WELS BILL OF MATERIAL ENERC "Y IS OUR BUSINESS Date: 10/31/2003 Quotation Number: P102011 RAUWELS TRANSFORMERS INC. Item Number: 15 Customer Line No.: Quantity: 3 Unit Price: $9,239.00 Extended Price: $27,717.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 1000 kVA Model #: ZA100163E480002 Mineral Oil Immersed Cooling Class: OA T Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 16340 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 95 kV Secondary BIL Rating: 30 kV High Voltage Taps: S Taps - 15480/15910/16340/16770/17200 No Load Loss: 1024 Watts Load Loss: 8029 Watts Total Loss: 9053 Watts Impedance: 5.75 % Tank Enclosure. Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Seeondary Terminations: Porcelain Bushings w/12 Hole Brass J Spades, Spade Support Protection. Dual Sensing Bayonet Fusing (353C12), Plastic Dripshield (), Spare bayonet fuses (2 sets), PRCLF (3545125m61m) Accessories. Pressure Relief Valve Qualitrol 202-037-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards. Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment. SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by FMC on 10V31l2W3 PA��WELS 61VERG1I IS OUR BUSINESS PAUWELS TRANSFORMERS INC. BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102011 Item Number: 16 Customer Line No.: Quantity: 2 Unit Price: $17,632.00 Extended Price: $35,264.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 2500 kVA Model #: ZA250163E480012 Mineral Oil Immersed Cooling Class: OA Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 16340 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 95 kV Secondary BIL Rating: 30 kV High Voltage Taps: S Taps - 15480/15910/16340/16770/17200 No Load Loss: 2234 Watts Load Loss: 16654 Watts Total Loss: 18888 Watts Impedance: 5.75 % Tank Enclosure. Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts SecondaryTerminations: Porcelain Bushings w/14 Hole Brass J Spades, Spade Support Protection. None Pressure Relief Valve Qualitrol 202-037-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color. GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Over Powder, Standards. Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment. SHIPMENT IN 8 TO 10 WEEKS AFTER RECEIPT OF ORDER Printed by FMC on IW31/2003 . . M%AIKNIEWELS EOPAMRAP .rM E.ERC;Y 1'.,�' 0,,R i. PAUWELS TRANSFORMERS INC. Quotation Number: P102012 Customer: CITY OF VERNON PURCHASING DEPT 4305 SANTA FE AVENUE VERNON, CA 90058 Attention: PURCHASING DEP Fax: 323-826-1425 Reference: QUOTATION NO 1429 Date: 10/31/2003 Cust. Code: VERNOI Region: 0400 We are pleased to present our quotation for three phase transformers with the accessories according to the attached bill of material(s) General Conditions: Prices: Firm for the duration of the contract. Validity: 30 days from the date of quotation. Taxes: Federal, state, local or any other taxes are excluded. Freight: Prepaid and Allowed, F.O.B. Destination Payment: 30 Days Net Payment Terms Warranty: Standard, 12 months from the date of installation, but not to exceed 18 months from the date of delivery. Any design dimensions, unless otherwise specified, are for indication only, and are not binding. This quotation is subject to Pauwels' Terms and Conditions of Sale, which are available upon request. Any deviation from the attached bill of material(s), before or after receipt of order, may affect price and delivery. The quoted ship weeks will go into effect after all outstanding technical matters have been resolved. Ship weeks are based on plant loading at time of quotation. Please verify ship weeks when placing an order. Please reference our quotation number on all purchase orders and correspondence. We will be pleased to provide you with any additional information that is required. Thank you for your inquiry, and we look forward to working with you in the future. Sincerely, PAUWEIS TRANSFORMERS, INC. Diana Kallmbah Account Specialist Utility Sales (636) 239-9300 x345 cc: PACIFIC UTIL Marc Schillebeeckx Vice President Sales & Marketing Utility / Industrial Sales (636) 239-9300 x349 " rwqbma le W'SWELS EMER tom► OUR eusimess RAUWELS TRANSFORMERS INC. Quotation Number: P102012 Customer: CITY OF VERNON PURCHASING DEPT 4305 SANTA FE AVENUE VERNON, CA 90058 Attention: PURCHASING DEP Fax: 323-826-1425 Quotation Comments: TEST REPORTS ARE SENT AT TWE OF INVOICING. Date: 10/31/2003 Cust. Code: VERN01 Region: 0400 MPAUWELS ENERGY IS 04LJR BUSINESS RAUWELS TRANSFORMERS INC. BILL OF MATERIAL Date: 10/31/2003 Quotation Number: P102012 Item Number: 01 Customer Line No.: Quantity: I Unit Price: $26,031.00 Extended Price: $26,031.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: Primary Voltage: Primary BIL Rating; High Voltage Taps: No Load Loss: 3750 kVA Mineral Oil Immersed 16340 Delta volts 95 kV Model #: Cooling Class: Frequency: Avg. Winding Temp. Secondary Voltage: Secondary BIL Rating: S Taps - 15480/15910/16340/16770/17200 2513 Watts Load Loss: 26229 Watts Impedance: 6 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel HV-LV Barrier ZA375163E480005 OA 60 Hz 65 °C 480Y/277 volts 30 kV Total Loss: 28742 Watts Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts SecondaryTerminations: Porcelain Bushings w/16 Hole Brass J Spades, Spade Support Protection: None Accessories: Pressure Relief Valve Qualitrol 202-037-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.OGY3.29/1.5), Touch-up Paint , Coal Tar Under Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise specified by the customer. Shipment: SHIPMENT IN 10 TO 12 WEEKS AFTER RECEIPT OF ORDER Printed by FMC on 10/31/2003 PAIUWELSBILL OF MATERIAL E.E. Y IS OUR �N Date:10/31/2003 - Quotation2012 10 P A U W E L S TRANSFORMERS INC. Item Number: 022012 Customer Line No.: Quantity: 1 Unit Price: $24,114.00 Extended Price: $24,114.00 Three Phase Pad -Mount Tansformer(s) kVA Rating: 3750 kVA Model #: ZA375163E480006 Mineral Oil Immersed Cooling Class: OA T Frequency: 60 Hz Avg. Winding Temp. 65 °C Primary Voltage: 16340 Delta volts Secondary Voltage: 480Y/277 volts Primary BIL Rating: 95 kV Secondary BIL Rating: 30 kV High Voltage Taps: S Taps - 15480115910/16340/16770/17200 No Load Loss: 3089 Watts Load Loss: 27862 Watts Total Loss: 30951 Watts Impedance: 6 % Tank Enclosure: Bolted Cover Stainless Steel Nameplate Cabinet Depth: 30 Inches, Pentahead Security Bolts Steel HV-LV Barrier Bushings: Radial Feed Custom Dimensions Dead Front Primary Terminations: Wells , (3) Inserts Secondary Terminations: Porcelain Bushings w/16 Hole Brass J Spades, Spade Support Protection: None Accessories: Pressure Relief Valve Qualitro1202-037-01, Drain valve w/Sampler Liquid Level Gauge, Liquid Temperature Gauge Switching: L.V. Neutral Bushing with Removable Grounding Strap, One ON/OFF Transformer Switch (300 Amps) Paint Color: GREEN (Munsell 7.0GY3.29/1.5), Touch-up Paint , Coal Tar Under Powder, Standards: Quoted in compliance with the latest applicable ANSI standards unless otherwise snecified by the customer. Shipment: SHIPMENT IN 10 TO 12 WEEKS AFTER RECEIPT OF ORDER Printed by PTINC on 10131/2003 n22 o4 TRANSFORMER OUTLINE MATERIALS LIST FOR DRAWING #P102011 DATED OCTOBER 28, 2003 1 High Voltage Bushing Wells (Cooper #2638372C01) And Inserts (Cooper #LBI215BP) 2 Low Voltage Epoxy Bushings With 5/8" Copper Studs (CM #701315-51) And 4-Hole Aluminum "H" Spades (150 kVA And 300 kVA) Low Voltage Epoxy Bushings With 1" Copper Studs (CM #701334-52) And 8-Hole Supported Aluminum "H" Spades (500 kVA) Low Voltage Epoxy Bushings With 1" Copper Studs (CM #701334-52) And 12-Hole Supported Brass "J" Spades (750 kVA) Low Voltage Porcelain Bushings With 1 1/a" Copper Studs And Integral 12-Hole Supported Brass "J" Spades (Warco #40A8008-1C), (1000 kVA) Low Voltage Porcelain Bushings With 2" Copper Studs And Integral 14-Hole Supported Brass "J" Spades (Warco #40A08019-5), (2500 kVA) Low Voltage Porcelain Bushings With 21/2" Copper Studs And Integral 16-Hole Sup d Brass "J" Spades (Warco #45A03096), (3750 kVA) 3 ESNA #151-PS Parking Stands 4 1/a" NPT 10 PSI 50 SCFM Pressure Relief Valve (Qualitrol #202-030-01) 5 2" Square Li uid Level Gauge With Weld Flange (Qualitrol #020-037-01) 6 VV NPT 4" Dial 120 Degree "C" Liquid Temperature Gauge (Qualitrol #150-101-01 7 Provision For 1" NPT Oil Fill Valve With Plug (UB #175T) 8 1" NPT Oil Drain Valve And Sampler (UB #175TSS) 9 Stainless Steel Nameplate With An Additional Nameplate On The Inside Of The Low Voltage Door 10 One -Hole Ground Pads Without Lugs (BB #TTC2P), (150 — 500 kVA) Two -Hole Ground Pads Without Lugs (BB #TTC2P), (750 — 3750 kVA) 11 Low Voltage Ground Strap 12 Provision For Lifting 13 Padlock Facility And Penta-Head Door Bolt 14 Low Voltage Door Handle 15 Removable Lower Front Sill 16 Base Arranement For Rolling In Two Directions 17 Transformer Tank 18 Low Voltage Compartment Door 19 High Voltage Compartment Door 20 Raised Air Compartment Top For Ba -O-Net Fuse Replacement 21 Jacking Provisions 22 No Cooling Fins (150 kVA And 300 kVA Low T.O.C. Design) Back Cooling Fins (300 kVA 5% T.O.C. Window Design And 500 =1000 kVA) Back And Side Cooling Fins (2500 — 3750 kVA) 23 Tap Changer `B" Taps +5% +2.5% -2.5% -5%; ASP #01.20.315 (150 — 300 kVA) ASP #01.208.25 (500 —1000 kVA Except For 750 kVA 7200V) ASP #01.21.825 (750 kVA 7200V And 2500 kVA) Cooper #2237471C01 (3750 kVA) 24 No "HOXO" Grounding Switch (Warco #50A00365) No "HOXO" Removable Link 25 Ba -O-Net Current / Fault Sensing Fuses In Fuse Holders With 2-Sets Of Spare Fuses; 7200 Volts; Cooper #353C14 (500 kVA) Cooper #353C16 (750 kVA) 16340 Volts; Cooper #353C10 (150 — 500 kVA) Cooper #353C12 (750 —1000 kVA) 26 Plastic Snap-On Drip Cups (CM #703824-57) 27 Door Holding Bars 1200 Open Position 28 Internal Partial Range Current Limiting Fuses; 7200 Volts; Parallel Cooper ELSP #3543080M51M (500 kVA) Cooper ELSP #3543200M51M (750 kVA) 16340 Volts; Cooper ELSP #3545080M51M (150 — 500 kVA) Cooper ELSP #3545125M61M (750 —1000 kVA) 29 Munsell Green Paint #7.0GY3.29/1.5 With Touch -Up Paint 30 Additional Protective Coal -Tar Base Over Coating 31 HV / LV Compartment Barrier 32 Stainless Steel Hinges 33 All Bushings are Externally Clamped 34 Provision For I/a" NPT Pressure Vacuum Gau a (Qualitrol #50-35E) 35 Bolted Cover 36 2-Position "On -Off' Switch (ABB #L095NC3003) With A Fuse Interlock When Fuses Are Supplied 37 Rat Hole 38 Labeling, Shieping Tag, Bay-O-Net Stenciling And Bushing Stenciling r ct (q 0 O h M O d' to 0 O 1* a0 N CO N 't N O N O N t-r N N, 0CD N 0 M �t T 00 O 00 to n 01 N N N r (D Ln N •- N to wN "t CD N co 1CO N r q LO N co to 0. T r (D*-ONLorM(� O r O t() r CD N T NtoO0r"tO to O CO M CD T N qNN O M *- N *" *- *- N N M Ln T N r r r N N M Ln N C0 N w N CO N co N (0 CD N N (O to N O U? N CD N (fl N Cfl N w N w N w N CO LO N Q to d d 't �t �t �A N d d' d �t d �t �t LA O O O o 0 0 0 N h O 0 0 0 0 0 0 N t` to 1n to Ln to to to r Mtn to to Ln Ln to CA T M 6 M 6 cM M (M ri 6 6 6 CM pj M 60 M M M 6 O Ln f� LO N� O O 0 O tq 0 I� O 0 O O LO N Q O Cn N O O O O LO N LO N O O Lc)O N •:.61 �t(OM11It(0(C) 66666cV •-C66CN661—:Oj d COMd'It000DNP- ACV � O LO to 0 0 to Q O O Lo o LO LO in O to O LO OnNLOO�OOtoh0NN LnN10h *- mt M to Cn m O It r d' Oi Lo Ln N C; LO r (D M m N to m co M co m M N Lo d' LO co in O (D 0 0 0 0 0 0 0 0 00 O 0000000 to LO LO LO to Ln to Lo to Ln to M Ln LO u) � Lo to CO (O (O CO Cfl CO Cfl CO CD Cfl CO CO Co CO (6 CO CO (D N N N N N N N N N N N N N N N N N N (D CD (D (O CO (O CD (O (D CD CD CD (D (O CD (D CD (D OD ODLn 00 00 M oo M T o0 M Ln M o0 M GO M T CD CD (4 (0 co CD (D h 00 Co. (D (0,(D CD (D CC) N 00 N N to LO N N to to � Ln N LO O Ln N O O O DO .-- N N OD r N N coN CD h to N 0 O LO N N Op to Cn N* W* .- t` O m 4 0 N M d' O w Q IT It COCO 'It It to 00 T CO 'It M CO CO mt to 00 T N N N N N N N N N N N N N N N N N N T T T T T �. T T 4 T to T 00 T 'I t T 'It I 77 'It fit T 'It T `t T 'It 177 M Ln000� 0toLn00n0n0c IN. O�LnctoDN �nD0�0000tnoDotnoo Tnn°°C°nToNo-06 (D►N00000 M CO CO CM COO r) CO r r) r CO CO CO CO r- coMtNMMd (D 11% r r CD 0 d''tItM'It CD CO T (D N NMC0011d r- t- (O (O (D it CO d NNnNt`NNNNnNr- �nNNNNN NItNNNNtItd'd'cmItNNNd'lot It qt 00 OD (O 00 00 00 OD 00 00 00 CO CD 100 00 00 CO 00 00 O O O Q O 0 0 LO to O O O O o 0 0 N to to LO to LO to LO to N N LO to U) LO Ln to in t` N (O (D LA (hhD CO CO CO co t, co C^^O M CO CO (^^D (O (O I^^h n N t� I� N N N f� I� l� N N N P� N I Pz N N\ N N N N N N N N\ N N N N N N �- >: >- �- �- >- �- >- >- >- >: >- >: >: >- >- O O 00 O O Q o 0 0 0 0 00 O O O O O Q co co O 00 co 00 a0 co co w w O w 00 co 00 co do 't e cm It I* It It �t It d' 'd N mt IIt ' 't I 't O O o o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 tnwTMN 0NM0 T00,N cm N m *-N O O M O I* LO O Q CO O N co O O m O 0 T T IttotDN00 r T T r T T r f� SPECIFICATION NO. TR2-2003 PADMOUNT TRANSFORMER CITY OF VERNON LIGHT AND POWER SEPTEMBER 15, 2003 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 1.0 SCOPE Supplier shall furnish all work for providing three-phase, deadfront, radial, self cooled, padmounted transformers for use on the City of Vernon's underground distribution system. The transformer sizes that the City requires are listed in Attachment A. This list does not preclude the possibility of ordering voltage and T KVA ratings not listed under this specification. 2.0 APPLICABLE STANDARDS A. The transformers shall conform to the applicable sections of the following standards to the extent referenced in this Specification, and as amended to the date of this Specification which, by reference, are included as part of this Specification. 1. C57.12.00 IEEE Standard General Requirements for Liquid - Immersed Distribution, Power, and Regulating Transformers. 2. C57.12.26 Requirements for Padmounted Compartmental - Type, Self Cooled, Three -Phase Distribution Transformers for Use with Separable Insulated High Voltage Connectors, High Voltage 34500GrdY/19920 Volts and Below, 2500 kVA and Smaller. 3. C57.12.28 Padmounted Equipment —Enclosure Integrity. 4. C57.12.90 IEEE Standard Test Code for Liquid -Immersed Distribution, Power, and Regulating Transformers and IEEE Guide for Short -Circuit Testing of Distribution and Power Transformers. 5. C57.91 Guide for Loading Mineral -Oil -Immersed Overhead and Padmounted Transformers Rated 500 kVA and Less with 650C or 550C Average Winding Rise. 6. C57.92 Guide for Loading Mineral -Oil -Immersed Power Transformers Up to and including 100 MVA with 650C or 550C Average Winding Rise. 7. C57.106 IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment. B. In the event of conflict between the codes and standards and this Specification, Supplier shall notify City of Vernon Light and Power Department and secure a written clarification before proceeding with the work. 3of16 (A I Y OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 3.0 SERVICE CONDITIONS 3. 1. Environment A. The transformers shall perform in accordance with all provisions of the Specification while subject to the service conditions specified in ANSI/IEEE C57.12.00. B. The transformer shall be suitable for 30 years of use -on the City of Vernon's electric system when installed in accordance with the service conditions set forth in ANSI/IEEE C57.12.00-1987, Section 4.0, in its entirety. 3.2. Seismic and Impact Loading A. Before and during installation, the transformers shall withstand, without damage, rough handling such as bouncing on a track when filled with insulating medium and impacting against or upon rigid structures at speeds up to five feet per second, and being lifted by two bosses or lifting second, and being lifted by two bosses or lifting bolts at any angle. Following these conditions, the transformers shall be capable to being energized without a pre- operational test. B. After installation and during the 30-year life of transformer, transformer will be subject to occasional earthquake motions (0.2g horizontal and 0.13g vertical) along with significant vibrations from traffic and from adjacent equipment. 3.3 Pre -installation Inspection The City of Vernon will, at its discretion, provide a pre -installation inspection of each transformer. 3.4 Operating Duty For its 30-year life, each transformer shall be suitable for operation under short circuit conditions as stated in ANSI/IEEE C57.12.00-1987,,Section 7.1. 4 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 3.5 Shipping A. All transformers shall be shipped to the City of Vernon, Soto Yard located at 2800 Soto Avenue, Vernon, CA 90058. Supplier's price shall be F.O.B. Soto Yard. B. Transformers will be delivered on a flatbed truck for side unloading by T forklift at ground level. C. Delivery will be scheduled Monday through Thursday 7:00 a.m. to 3:00 P.M. Supplier shall provide City with 48 hours notice prior to delivery. 4.0 RATINGS 4.1 Sizes The transformers shall be sized as shown in Attachment A. 4.2 Hiph Volta a Ratings Transformers shall be 60 Hz with BIL ratings as shown in the table below. Transformer and Connector High oltaa Ratings and Electrical Characteristics F� Electrical Characteristics of the Completely Assembled Transformer High -Voltage Connectors'' High -Voltage Rating' BIL 60-Hz dry one minute Voltage Ratings Minimum Phase -to -Ground /Phase -to- (kV) withstand (volts) BIL3- (kV) P&Vfe Phase (kV) (kV) High -Voltage 7200 16340 75 8.3/14.4 95 34 95 8.3/14.4 95 34 Series -Multiple High - Voltage 7200 x 16430 75 x 95 8.3/14.4 95 34 For complete connector rating, see ANSI/IEEE 386. Z Transformers are suitable for connectors with phase -to -ground or phase-to-ground/phase-to-phase high -voltage ratings as listed. 3 Arrester coordination may require higher BIL on multiple connection than indicated to achieve a minimum protection level of 20%. 5of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 4.3 Low Voltage Ratinq The secondary voltage shall be one of the following. The basic insulation level (BIL) of the secondary voltage shall be 30 kV: 480Y/277 208Y/120 4.4 Configuration All transformers shall be Delta -Wye configured with low voltage neutral having a fully insulated X. bushing with a removable ground strap. 4.5. Impedances Transformer impedance shall not be less than those shown in the table below. All transformer testing to determine transformer impedance shall be based on the base kVA rating of the transformers at the 55 degree or 65 degree temperature rise. The transformer impedances shall be shown on the transformer nameplate. Minimum Transformer Impedance KVA %Z 300-500 4.0 750-2500 5.75 3750 6.00 5.0 CONSTRUCTION FEATURES 5.1 Coil and Core Construction A. The transformer core shall be of high efficiency rectangular wound. core designed in five -leg or triplex configurations. The core shall be made from one of two processes: single -turn laminations of high quality, grain oriented silicon core steel or amorphous core (Le metallic glasses metal). B. The transformer coils shall be designed to maintain their nameplate KVA rating throughout the normal temperature range of operation which shall be 650C (80°C hot spot). All materials used shall be of the 65°C, 800C hot spot class. All materials shall be thoroughly tested for compatibility with all transformer components before being assembled. The primary coil shall 6of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS be manufactured from heavy varnish or paper insulated aluminum or copper wire. The secondary coil shall be manufactured from full width aluminum strip whose edges are finished to prevent burrs and insulated with epoxy -diamond paper between layers of the conductor. 5.2. Insulating Fluid A. The transformer insulating fluid shall be standard electrical grade mineral insulating oil. The insulating oil shall be tested and degassed to assure a chemically inert oil. The padmount transformers shall be furnished with oil' which meets the requirements specified in ASTM Standard D 3487 for mineral insulating oil, except that the DBPC content (% by weight) shall not be less than 0.15. The insulating oil in the equipment shall conform with ANSI C57.106. B. All transformer oil shall be tested for polychlorinated biphenyl's (PCBs) per ASTM D4059 and certified as having no detectable levels of PCB. 5.3 Taps and Changers A. The transformers shall be furnished with full capacity high -voltage taps. The tap changer shall be clearly labeled to reflect that the transformer must be de -energized before operating the tap changer as required in Section 3.3 of ANSI C57.12.26. Padlocking provisions are available for lever or hotstick operable handles. Tap changer operating mechanisms shall be permanently identified to show "De -energized Operation Only". Decals and stencils are not acceptable. The unit shall have one of the following tap configurations: Two - 2'/% taps above and below rated voltage such as the following: VOLTAGE FULL CAPACITY TAPS 16,340 17,200/16,770/15,910/15,480 7,200 7,560/7,380/7,020/6,840 B. The tap changer position indicating nameplate shall have numerals or letters that are clearly legible and of permanent quality. Decals and stencils are not acceptable. 7of16 LATY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 5.4 Gau es A. All transformers shall have a dial -type, magnetic, oil level gauge to provide a positive means of determining the required oil height. The preferred location of the gauge is above the switch handles, to ensure the switch remains under oil. B. All transformers shall have a dial -type, magnetic, temperature gauge to provide a positive means of determining the transformer temperature. The required location of the gauge is in the low voltage compartment above the bushings. 5.5 Drain and Replacement Provisions Insulating medium drain and replacement provisions shall be furnished as specified in ANSI C57.12.26. 5.6. Tanks and Terminal Compartment A. The transformer tanks, and all external appurtenances, shall be in accordance with ANSI C57.12.26. The overall dimensions and various appurtenances locations shall be found on each transformer per Attachments C and D. B. Transformers shall have bolted covers for all size transformers. C. The compartment depth shall be minimum in accordance with figure 7 of C57.12.26. A deeper compartment shall be provided for extended secondary bushings. The tank shall be of sufficient strength to withstand a pressure of 7 psig without permanent distortion. The following pressure relief devices are approved: 1. Qualitrol Model No. 202-030-001 2. Qualitrol Model No. 202-032-001. 5.7 Terminations Transformer bushings shall accommodate cable terminations in accordance with ANSWEEE 386, but shall be modified to provide the height requirements of these specifications as shown in Attachments C and D. 8of16 CITY OF VERNON LFGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 5.8 Nameplates A stainless steel nameplate shall be attached with non -corrosive hardware to the inside of the low voltage compartment door. The nameplate shall not be installed on the rear of the low voltage compartment area. Diagrams and numbers shall be of the size and quality such that they can be read from outside the compartment. In addition to the nameplate - requirements shown in ANSI/IEE C57.12.00-1987, Section 5.12, the total weight, including oil, shall be indicated. 5.9 Coating A. Each transformer and terminal enclosure combination shall be painted a forest green color such as Dulux Bell Telephone Green No. 183-Y-546 (Munsell 7.5GY2.95/2.1) or City of Vernon -approved equivalent. The primary and finishing coats shall have a combined minimum dry -film thickness of three mils. Manufacturer shall furnish 1/4 pint of touch up paint for each transformer. B.- The underside of each transformer shall be coated with an asphaltic Material or with City of Vemon-approved paint system. An epoxy coat which meets ANSI C57.12.28 is acceptable. 6.0 Loadbreak Switches 6.1 ' ype A. Each transformer shall have a three-phase, self-contained, oil immersed, high voltage, loadbreak gang -operated sectionalizing switch. The switches shall be inside the transformer tank and be so located that current interruption occurs under oil. The loadbreak switches shall provide circuit connections as shown in Attachments C-and D. Operation of the switch shall be clockwise to close. B. The operating handle shall be located in the high voltage compartment and be suitable for hot stick operation. The position of the switch, whether open or closed, shall be clearly indicated. The handle shall be located in such a manner as to be identifiable with the associated circuit -transformer. Stencils or decals to indicate switch positions are not acceptable. 9of16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 6.2 Interlocks The switch shall have an interlock which will prevent removal of fuses when the switch is in the closed position and also prevent the inserting of fuses when the switch is in the closed position. 6.3 Ratl"ngs The switches shall have the following ratings when completely assembled and installed in the transformers. A. Minimum Voltage Rating: 17,000 volts. B. Loadbreak Capability: 200 rms amperes at 17,000 volts and 0.6 power factor. C. Short -time current Rating: 10,000 rms symmetrical amperes for 15 cycles. Q. Closing and Holding 'Current Rating: 10,000 rms symmetrical amperes for 15 cycles. E. There shall be no arcing time after the switch blades have traveled from the closed position to the fully opened position. 7.0 OVERCURRENT PROTECTION 7.1 High Voltage Protection A. Transformers shall be protected against overcurrent by means of a City of Vemon-approved externally replaceable fuses in the primary circuit. The fuses shall be suitable for hot stick operation and shall have a minimum of 50,000 rms symmetrical ampere interrupting rating. The fuses shall have City of Vernon -approved safety devices which prevent insertion directly into a fault. B. The fuses shall be a Bay-0-Net type oil immersed fuses in series with oil immersed current limiter type RTE ELSP current limiting backup fuse. The fuses shall have a safety device which prevent insertion directly into a fault. 10 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS C. The correct size of Bay-O-Net fuse for replacement shall be indicated by stencil or decal above the Bay-O-Net fuse as follows: "Caution: Use only RTE Bay-O-Net Type 353C "(10, 12, etc.)" " Amps" (25, 40, etc.) D. The following table lists the appropriate fuse sizes: r Transformer Ratings KV KVA Rating FLA High Voltage Fuses' BAYONET ELSP MINIMUM Z /o 16.34 300 15.5 11 4000353C10 354508OM51M 4.00 500 15.5 18 4000353C10 354508OM51M 4.00 750 15.5 26 4000353C12 3545125M61M 5.75 1000 15.5 35 4000353C12 3545125M61 M 5.75 1500 15.5 53 4000353C16 354515OM51 M5 5.75 2000 15.5 70 4000353C16 354515OM51 M5 5.75 2500 15.5 88 NONE NONE 5.75 3750 15.5 132 NONE NONE 6.00 7.2 300 8.3 24. 4000353C12 3543125M61M 4.00 500 8.3 40 4000353C14 354308OM51M5 4.00 750 8.3 60 4000353C16 354320OM51M 5.75 1000 8.3 80 4000353C17 3543175M51 M5 5.75 1500 8.3 120 NONE NONE 5.75 E. A minimum of 6 spare Bay-O-Net fuses shall be provided with each transformer order. For instance, if we order one 7.2 W type 300 KVA transformer we require 6 spare fuses. If we order two such transformers, we require 12 spare fuses. 7.2 Low Voltaae Protection Low voltage overcurrent protection is not required. s Cooper (Type Bay-O-Net and Current Limiting ELSP) Two parallel fuses per phase 11 of 16 U11 Y OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 8.0 BUSHINGS, BUSHING WELLS AND PARKING STANDS 8.1 Low Voltage Bushings A. Transformers shall have bushings which conform to ANSI Standard C57.12.26. On "Wye" connected transformers, the neutral shall be connected to a fully insulated bushing. An additional tank ground T pad with removable neutral bushing ground strap shall be provided and suitably sized for the short circuit current rating of the transformer. B. External spade terminals shall have a heavy tin coating process. If the terminal extension is not an integral part of the bushing, it shall be securely pinned to the stud. C. External spade terminals with six holes and more shall be furnished with additional support straps, designed by the manufacturers, at the end farthest from the tank wall without interfering with the -use of any of the holes. Each extension pad shall be fully rated for the maximum ampacity of the transformer. Refer to the table below for the number of terminal holes. KVA Ratings Low -Voltage Ratings (Volts) Number of 9/16" hole cable positions 75-300 ALL 4-6 , 500 ALL 8 750-1500 ALL 12 2000-2500 ALL 14 3750 ALL 16 8.2 High Voltage Bushing Wells Transformers shall be provided with three City of Vemon-approved, 17 kV high voltage bushing wells rated 95 kV BIL, marked and located as shown in Attachments C and D. 8.3 Parking Stands Transformers shall be equipped with non -load break parking stands, ESNA No. 151-PS or City of Vernon -approved equivalent. They shall be located as shown in Attachments C and D and in accordance with ANSI Standard C57.12.26. 12 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 9.0 IDENTIFICATION 9.1 Stencils & MSDS A. All bushings shall be identified by yellow paint stencils, a minimum of T one inch high, on the tank wall adjacent to the bushings. See Attachments, C and D. B. A removable identification tag or sticker which shall be legible at time of receipt shall be attached to the exterior of the terminal compartment. The tag or sticker shall indicate the name of the manufacturer, serial number, kVA and voltage ratings. C. In addition to the nameplate. information called for in ANSI C57.12.00, the nameplate shall identify each winding as to whether it is made of copper or aluminum. D : The vendor shall be required to provide all applicable Material Safety Data Sheets with all transformer orders. 10.0 ADDITIONAL REQUIREMENTS, 10.1 Barriers A barrier shall separate the high -voltage section from the low voltage section in the terminal compartment.. Barrier shall be of sufficient strength to prevent deformation which may reduce the required clearances to various components. 10.2 Conduit Entrance When specifically requested in the transformer table below, a 2 %2 inch conduit entrance hole, with a cover which is removable only from the inside, shall be provided in the center of the low voltage sill. 13 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS 10.3 Terminal Arrangements Terminal arrangements shall be as shown in Attachments C and D. 10.4 Access to Terminal and Switching Compartments A. Transformers shall be provided with hinged doors for access to the T terminal and switching compartments. Access to the high voltage portion of the terminal and switching compartment shall be possible only after access has been gained to the low voltage. B. The low voltage compartment door shall be further secured by means of a captive and recessed '/z inch pentahead bolt. A blind bolt hole shall be provided. Bolts shall be corrosion resistant and the design shall minimize the possibility of a misalignment and cross -threading. Design of the bolting, padlocking and three-point latching provisions shall be coordinated such that, only after the padlock and bolt have been removed, shall it be possible to open the low voltage compartment door. 11.0 TESTS 11.1 General A. Transformer tests shall be performed as specified in ANSI Standard C57.12.00. These test reports shall be provided to the City prior to shipping. The City will not receive any transformers without the required test reports. B. Units shall comply with routine test requirements of ANSI and certified test reports shall be furnished. The vendor shall provide with returned bids all applicable documentation of compliance with ANSI design tests. C. The following data shall be submitted with.each transformer order: a. Guaranteed maximum no load (excitation) loss at rated voltage and 110% voltage in Watts. 1. - b. Guaranteed maximum load loss in Watts at rated voltage and 110% voltage. c. Guaranteed maximum total loss in Watts at rated voltage and 110% voltage. 14 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS d. Exciting Current in percent at rated voltage and 110% rated voltage. e. Percent impedance on base voltage and at the maximum temperature rise. If the transformer is a 55165 degree Celsius transformer rise, the percent impedance shall be at 65 degree Celsius. f. Efficiencies shall be provided at loading levels of 100%, 75%, 50%, and 25%. g. Regulation at rated load @ 80% and 100% Power Factor. h. Two sets of outline drawings showing dimensions, weight, gallons of oil, gauge of steel in tank walls, cover, bottom, and cooling radiators and description of accessories. After order is awarded, the vendor shall submit FINAL drawings. 12.0 OPERATING PERFORMANCE 12.1 General The Apparatus shall perform in accordance with the conditions set forth in this Specification. 13.0 BID EVALUATION 13.1' Total Ownership Cost Purchase of transformers shall be evaluated by lowest total ownership cost. The formula to evaluate Total Owning Cost (TOC): TOC = C + $4.53/W (PNL in Watts) + $1.1/W (PLL in Watts) Where TOC is the total ownership cost in dollars, C is the initial cost in dollars, PNL is the guaranteed maximum no-load loss in watts, and PLL is the guaranteed maximum load loss in watts For the determination of the award for the transformer order(s), City will consider all bids within 5% of the lowest Present Value Cost of Transformer to be economically equivalent. The City of Vernon realizes it is impossible to accurately predict economic conditions over the evaluation period of 30 years. 15 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS T 13.2 Delivery A delivery date of 16 weeks ARO or less is required. Failure to quote a delivery schedule within this period may disqualify the bid. 14.0 DOCUMENTATION 14.1 For Bid Evaluation Bidders shall fumish the following in their bid proposals: 1. Transformer unit price, F.O. B. Soto Yard. 2. Guaranteed maximum no-load loss at rated voltage in watts. 3. Guaranteed maximum load loss in watts at rated voltage and WA. 4. Percent impedance on rated voltage tap. 5, Two sets of dimension and outline drawings. 14.2 For Delivery Supplier shall fumish MSDS and certified test reports and drawings, as listed in Section 11.1 in this Specification one month before transformers are shipped. These documents shall be submitted to: City of Vemon Utilities Department 4305 Santa Fe Avenue Vemon Ca, 90058 Phone: (323) 583-8811 Attention: Ramon Z. Abueg Assistant Director of Engineering and Operations 16 of 16 CITY OF VERNON LIGHT AND POWER PADMOUNT TRANSFORMER TECHNICAL REQUIREMENTS Attachment A. Transformer Sizes ONE CIRCUIT (RADIAL) LINE A CL AY-O-NET TWO CIRCUIT (LOOPED) LINE A /o LINE B CL BAY-O-NET VERNON LIGHT AND POWER EQU►PMENT: SPECIFICATION TR2 ADDITIONAL CIRCUIT CONNECTIONS 11/2/01 ' i AV NO REVISION DATE APPV'D BY ATTACHMENT B i I � 0 70" MAX RADIATORS MAY EXTEND BEYOND TH E DIMENSIONS SHOWN z Q a0 o PLAN �- SEE NOTE 2 -� EXTERNALLY REPLACEABLE CL FUSES L--- L.----- -1 o Uo uo NAMEPLATE H1 H2 H3 x TRANS SW. w o x x x 0 1 3 z n FQ- O O N 0 2 Z Y a n 2-1/2" CONDUIT HOLE (SEE NOTE 3) �40-1/2" MIN " 22 MIN. L ATI N BAY-O-NET FUSE SCHEMATIC DIAGRAM NOTES: 1. ALL DIMENSIONS AND CLEARANCES SHALL CONFORM WITH ANSI C57.12.26. 2. CURRENT LIMITING FUSES INTERLOCKED WITH TRANSFORMER SWITCH. x X x x O 1 2 3 3. 2-1/2" CONDUIT HOLE SHALL BE LOCATED IN THE CENTER (BOTH HORIZONTALLY AND VERTICALLY) OF THE LOW VOLTAGE CABINET SILL. VERNON UTILITIES DEPARTMENT EanPtaE►rr SPECIFICATION TR2 ONE -CIRCUIT PADMOUNTED TRANSFORMERS ,0�30�01A'-� nv 75 THROUGH 500 KVA REVISION DATE BY ATTACHMENT C I 750 THROUGH 3750 KVA 28" MIN -i -Ir— 22" MIN PLAN EXTERNALLY REPLACEABLE CL FUSES • I uo uo uo H1 H2 143 0 x x 1 3 O O x x 0 2 ELEVATION �- NAMEPLATE TRANS SW. RADIATORS MAY EXTEND BEYOND THE DIMENSIONS SHOWN DIM 750. 1000 do 1500 KVA 2000 AND 3750 KVA A 77" MAX 87" MAX B 80" MAX 85" MAX C 76" MAX 90" MAX D 26" MIN 26" MIN E 42" MIN 42" MIN SECONDARY BUSHING LOCATIONS TO CONFORM WITH ANSI STANDARD C57.12.22 - FIG. 3 2-1/2" CONDUIT HOLE (SEE NOTE 3) --i 6" 6" 02-1/2" CONDUIT HOLE ELEVATION NOTES: 1. ALL DIMENSIONS AND CLEARANCES SHALL CONFORM WITH ANSI C57.12.26. 2. CURRENT LIMITING FUSES INTERLOCKED WITH TRANSFORMER SWITCH. 3. 2-1/2" CONDUIT HOLE SHALL BE LOCATED IN THE CENTER (BOTH HORIZONTALLY AND VERTICALLY) OF THE LOW VOLTAGE CABINET SILL. VERNON LIGHT AND POWER EOLNpmm- SPECIFICATION TR2 ONE -CIRCUIT PADMOUNTEC TRANSFORMERS 750 THROUGH 3750 KVA 9/11/03 �L1 40 REVISION DATE APPV'D BY ATTACHMENT D SUPPORTING DOCUMENTS CITY COUNCIL Y LEONIS C. MALBURG Mayor THOMAS A. YBARRA Mayor Pro -Tern WM. 'BILL" DAVIS Councilman H. "LARRY" GONZALES Councilman W. MICHAEL MCCORMICK Councilman BRUCE V. MALKENHORST CITY HALL City Administrator/City Clerk 4305 SANTA FE AVENUE, VERNON, CALIFORNIA 90058 FAX (323) 826-1438 TELEPHONE (323) 583-8811 November 13, 2003 City Council City of Vernon Honorable Members: EDUARDO OLIVO City Attorney FAX: (562) 869-1883 KEVIN WILSON Director of Community Services & Water FAX: (323) 826-1435 KENNETH J. DeDARIO Director of Light & Power FAX: (323) 826-1425 STEVEN E. PARKER Fire Chief FAX: (323) 826-1407 BRUCE W. OLSON Police Chief FAX: (323) 826-1481 On October 1, 2003, this legislative body approved Resolution No. 8287, inviting sealed proposals or bids for the purchase of nineteen (19) Padmounted Transformers for the Light & Power Department. On November 4, 2003, the Purchasing Section received and opened the following bids: • ERMCO $124,921.00 • ABB, Inc. $186,809.00 • Cooper Power $188,206.00 • Pauwels Transformers $196,086.00 • Howard Transformers $202,259.00 • General Electric Co. $233,780.63 This has been reviewed by the Light & Power Department and it is hereby recommended that Bid No. 1429 be awarded to the below listed vendors, two equipment purchase contracts be prepared, and two purchase orders be issued for the purchase of the following transformers at the stated amounts: • ABB Inc. tity KVA Total Amount 3 500 1 150 3 300 3 1000 2 2500 $97,099.00 Padmounted Distribution Transformers November 13, 2003 Page 2 • Pauwels Transformers c/o Pacific Utilities Supply Co. Quantity KVA Total Amount 2 750 1 500 3 750 1 3750 $79,954.00 Very truly yours, Bruce V. Malkenhorst City Administrator/City Clerk BVM/gm