Resolution No. 83241 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 RESOLUTION NO. 8324 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF VERNON APPROVING AND AUTHORIZING NOTICE INVITING SEALED PROPOSALS OR BIDS FOR THE PURCHASE OF OVERHEAD DISTRIBUTION TRANSFORMERS FOR THE LIGHT & POWER DEPARTMENT WHEREAS, the Light & Power Department is in need of 115 various one -phase, 60 Hz, mineral oil filled, overhead type distribution transformers (the "Transformers") to replenish the stock for projected service requirements for fiscal year 2003-2004; and WHEREAS, on November 25, 2003, the Finance Committee considered the recommendation of Bruce V. Malkenhorst, Director of Finance, dated November 20, 2003, that authority be granted for the Purchasing Agent, or his designee, to seek formal bids for the purchase of the Transformers; and WHEREAS, Specification No. TR1-2003 dated November 19, 2003, (the "Specification") has been prepared for the purchase of the Transformers; and WHEREAS, the City Council of the City of Vernon has determined that it is in the best interests of the City of Vernon that bids or proposals be solicited in accordance with the Vernon City Code. NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF VERNON AS FOLLOWS: SECTION 1: The City Council of the City of Vernon hereby finds and determines that the recitals contained hereinabove are true and correct. SECTION 2: The Specification, a copy of which is attached 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 hereto as Exhibit "A" and made a part hereof, is hereby approved by the City Council of the City of Vernon. SECTION 3: The City Clerk of the City of Vernon, or his designee, is hereby directed to give notice, in writing, inviting sealed proposals or bids for the purchase of the Transformers in accordance with the Specification, and in accordance with this resolution. SECTION 4: There being no newspaper of general circulation printed, published or circulated in the City of Vernon, the City Clerk is hereby directed to post said notice, or cause the same to be posted, in three of the most public places in the City of Vernon, to wit: the northwest corner of 38th Street and Santa Fe Avenue, the northeast corner of Leonis Boulevard and Pacific Boulevard, and on the bulletin board in the lobby of the City Hall of the City of Vernon, located at 4305 Santa Fe Avenue, in said City. SECTION 5: The City Clerk of the City of Vernon is hereby directed to post said notice forthwith and the first posting of said notice shall be at least ten (10) days before the opening of the bids for the proposed contract. Said notice shall provide that sealed proposals or bids will be received by the City of Vernon at the office of the City Clerk, or his designee, at the City Hall, 4305 Santa Fe Avenue, Vernon, CA 90058-0805. - 2 - 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 SECTION 6: The City Clerk of the City of Vernon shall certify to the passage of this resolution, and thereupon and thereafter the same shall be in full force and effect. APPROVED AND ADOPTED this 3rd day of December, 2003. ATTEST: ' BRUCE V. MALKENHORST, City Clerk LEONIS C. MALBURG,fMayor - 3 - 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 STATE OF CALIFORNIA ) ) ss COUNTY OF LOS ANGELES ) I, BRUCE V. MALKENHORST, City Clerk of the City of Vernon, do hereby certify that the foregoing Resolution, being Resolution No. 8324, was duly adopted by the City Council of the City of Vernon at a regular meeting of the City Council duly held on Wednesday, December 3, 2003, and thereafter was duly signed by the Mayor of the City of Vernon. (SEAL) BRUCE V. MALKENHORST, City Clerk - 4 - EXHIBIT it" SPECIFICATION NO. TR1-2003 OVERHEAD DISTRIBUTION TRANSFORMERS CITY OF VERNON LIGHT AND POWER November 19, 2003 SPECIFICATION NO. TR1-2003 Approved Manufacturers/Suppliers 1. Cooper Power c/o Mark Christensen Utility Products 44-909 Golf Center Pkwy, Suite #12 Indio, CA 92201 Phone: (760) 863-1660 2. ABB Inc. Attn: Jeff Vivian 2945 Harding Street, Suite 207 Carlsbad, CA 92008 Phone: (760) 720-3156 3. Howard Transformers c/o Young and Company 530 South Marengo Ave Pasadena, CA 91101 Phone: (626) 795-9955 4. General Electric Company c/o Southwest Power 9837 Pioneer Blvd. Santa Fe Springs, CA 90670 Phone: (562)801-4577 5. Central Moloney c/o Southcoast Utility Sales 8762 Luss Drive Huntington Beach, Ca 92646 (Phone): (714) 962-0841 Fax: 714-963-2487 6. Kuhlman Electric Corp. 101 Kuhlman Road Versailles, KY 40383 (Phone): (800) 395-6932 Fax: 859-873-8032 Prepared by: Approved by Kenneth DeDario, P.E. Director of Light and Power CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 1.0 SCOPE Supplier shall furnish all work for providing one -phase, 60 Hz, mineral oil filled, overhead type distribution transformers rated 500 kVA and below for use on the City of Vernon's overhead distribution system. The transformer sizes that the City requires are listed in Attachment A. This list does not preclude the possibility of ordering voltage and KVA ratings not listed under this specification. In comparing proposals or bids, consideration will not be confined to lowest ownership cost only. The successful bidder will be one whose product is judged to best serve the interests of the City of Vernon when first cost, lowest ownership cost, product, safety, quality, and delivery are considered. The City of Vernon reserves the right to reject any or all proposals or bids or any part thereof, and to waive any minor technicalities from the specifications. A contract will be awarded to the bidder submitting the lowest responsible bid meeting the requirements of this specification. 2.0 APPLICABLE STANDARDS A. The transformers shall conform to the applicable sections of the following standards to the extent referenced in this Specification, and as amended to the date of this Specification which, by reference, are included as part of this Specification. A. C57.12.00 IEEE Standard General Requirements for Liquid - Immersed Distribution, Power, and Regulating Transformers. B. C57./12.10 Requirements for Transformers 230,000 Volts and Below, 833/958 through 8,333/10,417 kVA single phase, and 750/862 through 60,000/80,000/100,000 kVA three phase without Load Tap Changing; and 3750/4687 through 60,00/80,000/100,000 kVA with Load Tap Changing -Safety Requirements. C. C57.12.20 Overhead -Type Distribution Transformers, 500 kVA and Smaller: High Voltage, 34 500 Volts and Below; Low Voltage 7970/13800Y Volts and Below D. C57.12.90 IEEE Standard Test Code for Liquid -Immersed Distribution, Power, and Regulating Transformers and IEEE Guide for Short -Circuit Testing of Distribution and Power Transformers. E. C57.91 Guide for Loading Mineral -Oil -Immersed Overhead and Padmounted Transformers Rated 500 kVA and Less with 650C or 550C Average 3of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS Winding Rise. F. C57.106 IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment. B. In the event of conflict between the codes and standards and this Specification, Supplier shall notify City of Vernon Light and Power Department and secure a written clarification before proceeding with the work. 4of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 3.0 SERVICE CONDITIONS 3. 1. Environment A. The transformers shall perform in accordance with all provisions of the Specification while subject to the service conditions specified in ANSI/IEEE C57.12.00. B. The transformer shall be suitable for 30 years of use on the City of Vernon's electric system when installed in accordance with the service conditions set forth in the latest edition of the ANSI/IEEE C57.12.00, Section 4.0, in its entirety. 3. 2. Seismic and Impact Loading A. Before and during installation, the transformers shall withstand, without damage, rough handling such as bouncing on a truck when filled with insulating medium and impacting against or upon rigid structures at speeds up to five feet per second, and being lifted by two bosses or lifting second, and being lifted by two bosses or lifting bolts at any angle. Following these conditions, the transformers shall be capable to being energized without a pre- operational test. B. After installation and during the 30-year life of transformer, transformer will be subject to occasional earthquake motions (0.2g horizontal and 0.13g vertical) along with significant vibrations from traffic and from adjacent equipment. 3.3 Pre -installation Inspection The City of Vernon will, at its discretion, provide a pre -installation inspection of each transformer. 3.4 Operating Duty A. For its 30-year life, each transformer shall be suitable for operation under short circuit conditions as stated in the latest editions of ANSI/IEEE C57.12.00 and C5712.90. Supplier shall supply verification that the design has passed the required short circuit criteria. 5of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 4.0 RATINGS 4.1 Sizes The transformers shall be sized as shown in Attachment A. 4.2 High Voltage Ratings Transformers shall be 60 Hz with BIL ratings and Insulation Class as shown in the table below. Transformer Hinh Veltane Insulation Characteristics Transformer High Voltage KV Insulation Class (KV) Insulation BIL (KV) 7.2/12.47Y 15 95 16.34 18 125 4.3 Low Voltage Rating Transformers shall be 60 Hz with BIL ratings and Insulation Class as shown in the table below. Transformer Low Voltaae Insulation Characteristics Transformer High Voltage Volts Insulation Class (KV) Insulation BIL (KV) 120/240 1.2 30 277 1.2 30 6of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 4.4. Impedances Transformer impedance shall not be less than those shown in the table below. All transformer testing to determine transformer impedance shall be based on the base kVA rating of the transformers 65 degree Celsuis temperature rise. The transformer impedances shall be shown on the transformer nameplate. Minimum Transformer Impedance VOLTAGE KVA %Z 240 10-75 2.0 240 100-167 2.5 240 250 3.0 277 15-100 2.0 277 167-333 2.5 277 500 3.0 5.0 CONSTRUCTION FEATURES 5.1 Coil and Core Construction A. The transformer core shall be of high efficiency rectangular wound core.. The core shall be made from one of two processes: single -turn laminations of high quality, grain oriented silicon core steel. Amorphous core (Le metallic glasses metal) transformers are not acceptable. B. The transformer coils shall be designed to maintain their nameplate KVA rating throughout the normal temperature range of operation which shall be 650C (80°C hot spot). All materials used shall be of the 650C, 800C hot spot class. All materials shall be thoroughly tested for compatibility with all transformer components before being assembled. C. The primary coil shall be manufactured from heavy varnish or paper insulated aluminum or copper wire. The secondary coil shall be manufactured from full width aluminum strip whose edges are finished to prevent burrs and insulated with epoxy -diamond paper between layers of the conductor. D. All insulating paper used as layer insulation in transformer coil shall be bonded type, coated on both sides with a thermosetting adhesive and properly cured prior to impregnating with oil or the coils shall be wound with primary conductor containing a thermosetting adhesive that when properly cured will form an effective bond, both turn to turn and layer to layer. 7 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 5.2. Insulating Fluid A. The transformer insulating fluid shall be standard electrical grade mineral insulating oil. The insulating oil shall be tested and degassed to assure a chemically inert oil. The transformers shall be furnished with oil which meets the requirements specified in ASTM Standard D 3487 for mineral insulating oil, except that the DBPC content (% by weight) shall not be less than 0.15. The insulating oil in the equipment shall conform with ANSI C57.106. B. All transformer roil shall be tested for polychlorinated biphenyl's (PCBs) per ASTM D4059 and certified as having no detectable levels of PCB. All oil furnished by supplier shall not contain any detectable traces of polychlorinated biphenyls. C. A sealed tank shall be provided on all transformers 5.3 Taps and Changers A. The transformers shall be furnished with full capacity high -voltage taps. The tap changer shall be externally operated and clearly labeled to reflect that the transformer must be de -energized before operating the tap changer as required in Section 3.3 of ANSI C57.12.26. Padlocking provisions shall be available for lever or hotstick operable handles. Tap changer operating mechanisms shall be permanently identified to show "De -energized Operation Only". Decals and stencils are not acceptable. The unit shall have one of the following tap configurations: Two - 2Y2% taps above and below rated voltage such as the following: VOLTAGE FULL CAPACITY TAPS 16,340 17,200/16,770/15,910/15,480 7,200 7,560/7,380/7,020/6,840 B. The tap changer position indicating nameplate shall have numerals or letters that are clearly legible and of permanent quality. Decals and stencils are not acceptable. 8of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 5.4 Pressure Withstand and Pressure Relief A. An assembly shall be provided that is designed for pressure relief. The assembly shall remain effectively sealed for overloads and external secondary short circuits of the duration and magnitude allowed by industry standards, but shall relieve pressure at a minimum of 8 PSIG. Design should meet the requirement of the latest edition of the ANSI C57.12.20 paragraph 6.27 for relief of excessive pressure. B. The valve shall be of the indicating type with weatherproof cover, and equipped with a pull -ring for hook -stick operation. It shall have 1/4 inch NPT threads and be located on the tank wall above the oil level in either segment 2 or 4 as designed in ANSI C57.12.20, Table S2. The valve shall meet the following minimum operating characteristics: 1. Cracking Pressure: 10 PSIG 2. Re -seal: 5 PSIG 3. Flow Rates: 50 SCFM at 15 PSIG 100 SCFM at 50 PSIG C. The valve body and various parts of the device shall be corrosion resistant. Only the following pressure relief devices are acceptable: 1. Circle Seal Model No. P60-383 2. Qualitrol Model No. 202-032-01 or 202-33-01 3. Beta Model Nos. 1712K-1, -5, -6, or Model No 1750K-5. D. The required electrical clearances between pressure relief valve and live parts shall be maintained. 5.5 Tank Pressure Withstand A. Tank withstand should meet the latest edition of NEMA TR1, Part 2. B. Tank bottom shall have a rolled edge and tank wall base which is three layers thick. 5.6 Tank Finish A. Tank covers shall have a slope of 15 degrees for moisture run-off and 100 WA and below, shall have an insulated coating on the cover capable of withstanding 15kV at a 2000 volt/sec rate of rise, or equal, tested per ASTM D149 using 1/4" diameter electrodes, or equal. The results of design test to confirm this capability shall be submitted for approval. 9of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS B. The tank coat will be a finish which can withstand a direct blow of 160 inch -pounds per ASTM D-2794-69 for units 100 kVA and below and meets or exceeds the following as set forth in ANSI C57.12.28: 1. Salt spray for 1000 hours 2. Humidity Test, 3. Abrasion resistance 4. Crosshatch adhesion 5. Oil resistance. C. The paint on all transformer tanks shall be grayish in color and conform to Munsell 5BG 7.0/04 with the following tolerances: 1. Hue: +/-12 (3G and 7B) 2. Value: +/-0.2 3. Chroms: +/-0.2 5.7 Tank and Covers A. Transformers shall have bolted covers for all size transformers. One spare bolt per each transformer shall be provided and included in the bid. 5.7 Internal Lead Identification A. Internal secondary leads shall be identified with appropriate markings permanently embossed in the lead that correspond with lead markings on the nameplate. 5.8 External Features A. Transformers shall be provided with cover mounted high voltage porcelain bushings with eyebolt terminals, low voltage porcelain bushings with eyebolt terminals and ANSI single position support lugs (hanger brackets) with nameplate on lower bracket. For all transformers rated above 167 kVA, no support brackets are required. 5.9 Weight and Dimensions A. The maximum weight for transformers 100 kVA and below shall be 1,400 lbs. B. All 250, 333, and 500 kVA single phase transformers shall be 'light weight" transformers. The weights and dimensions of the "lightweight" transformers shall not exceed the weights and dimensions specified below. 10 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS Rating (kVA) Weight (lbs) Height Inches Width Inches Depth Inches 250 2,500 72 41 38 333 2,800 72 41 38 500 3,300 72 50 42 5.11 Ground Provisions A. All transformers shall have a tank grounding provision. 5.12 High Voltage Bushings A. Transformer rated 15 kVA through 167 kVA shall be furnished with two cover -mounted bushings. High Voltage bushing terminals shall be in accordance with the latest edition of the ANSI Standard C57.12.20, paragraph 6.1.2.2. B. The cover -mounted bushings shall be of the 15kV insulation class for 7kV transformers and 17kV insulation class for 16kV transformers. The creepage distance of the bushings shall not be less than 15 inches. C. When the distance between live parts of cover -mounted bushings is less than 12 inches, the bushings shall be equipped with approved bird guards. Bird guards that are approved for use on overhead transformers are`. MANUFACTURER MODEL NUMBER Coltec Industries 703803-53 Porcelain Products 65001 through 65019 RTE 0704119b01 Kuhlman Electric 6210209902 assembly 6210208804 assembly 11 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 5.13 Internal High -Voltage Connections A. Each internal high -voltage lead shall be equipped with either a ring - tongue or a hook -type connector. Each connector shall be terminated on a fixed threaded stud, a fixed threaded bolt, or a non -removable threaded bolt, each having two nuts for holding and locking purposes. 1. Ring -tongued type: The ring -tongue terminals shall have mechanical and electrical properties so as to contain the high - voltage leads, without breaking, even under short-circuit conditions. Burndy type YAV are typical of the type desired. 2. Hook type: Hook terminals shall meet the same physical requirements as specified above for ring -tongue terminals. In addition to the above, both changing and locking nuts shall be held captive to prevent their complete removal. AMP, Inc. Style No. 3 "Hook" terminals are typical of the type desired. 5.14 Nameplates A. A stainless steel nameplate shall be attached with non -corrosive hardware to the inside of the low voltage compartment door. The nameplate shall not be installed on the rear of the low voltage compartment area. Diagrams and numbers shall be of the size and quality such that they can be read from outside the compartment. In addition to the nameplate requirements shown in ANSI/IEE C57.12.00- 1987, for nameplate A with total weight including oil shall be indicated. 5.15 MSDS A. The supplier shall be required to provide all applicable Material Safety Data Sheets with all transformer orders. 6.0 TESTS 6.1 General A. Transformer tests shall be performed as specified in ANSI Standard C57.12.00. These test reports shall be provided to the City prior to shipping. The City will not receive any transformers without the required test reports. B. Units shall comply with routine test requirements of ANSI and certified test reports shall be furnished. The vendor shall provide with returned bids all applicable documentation of compliance with ANSI design 12 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS tests. C. The following data shall be submitted with each transformer order: a. Guaranteed maximum no load (excitation) loss at rated voltage and 110% voltage in Watts. b. Guaranteed maximum load loss in Watts at rated voltage and 110% voltage. c. Guaranteed maximum total loss in Watts at rated voltage and 110% voltage. d. Exciting Current in percent at rated voltage and 110% rated voltage. e. Percent impedance on base voltage and at the maximum temperature rise. f. Efficiencies shall be provided at loading levels of 100%, 75%, 50%, and 25%. g. Regulation at rated load @ 80% and 100% Power Factor. h. Two sets of outline drawings showing dimensions, weight, gallons of oil, gauge of steel in tank walls, cover, bottom, and cooling radiators and description of accessories. After order is awarded, the vendor shall submit FINAL drawings. i. Verification that the transformer design has passed the required short circuit criteria per Section 3.4 of these specifications. 7.0 OPERATING PERFORMANCE 7.1 General The Apparatus shall perform in accordance with the conditions set forth in this Specification. 13 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 8.0 BID EVALUATION 8.1 Total Ownership Cost The purchase price of transformers shall be evaluated by lowest total ownership cost. The formula to evaluate Total Owning Cost (TOC): TOC = C + $4.53/W (PNL in Watts) + $1.1/W (PLL in Watts) Where TOC is the total ownership cost in dollars, C is the initial cost in dollars, PNL is the guaranteed maximum no-load loss in watts, and PLL is the guaranteed maximum load loss in watts For the determination of the award for the transformer order(s), City will consider all bids within 5% of the lowest Present Value Cost of Transformer to be economically equivalent. The City of Vernon realizes it is impossible to accurately predict economic conditions over the evaluation period of 30 year s. Reference Section 1, SCOPE, second paragraph of these specifications. 8.2 Delivery A delivery date of 16 weeks ARO or less is required. Failure to quote a delivery schedule within this period may disqualify the bid. 9.0 DOCUMENTATION 9.1 For Bid Evaluation Bidders shall furnish the following in their bid proposals: 1. Transformer unit price, F.O. B. Soto Yard. 2. Guaranteed maximum no-load loss at rated voltage in watts. 3. Guaranteed maximum load loss in watts at rated voltage and kVA. 4. Percent impedance on rated voltage tap. 5. Two sets of dimension and outline drawings. 14 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 9.2 For Delivery Supplier shall furnish MSDS and certified test reports and drawings, as listed in Section 11.1 in this Specification one month before transformers are shipped. These documents shall be submitted to: City of Vernon Utilities Department 4305 Santa Fe Avenue Vernon Ca, 90058 Phone: (323) 583-8811 Attention: Jose Lugo Electrical Engineer 10. CONTRACT A. The vendor may be required to execute a purchase contract with City of Vernon, and may be required to furnish proof of insurance pursuant*to Attachment B, Insurance Schedule. If required, the vendor shall provide a letter from its insurance company that certifies the amounts of the insurance policy. The letter from the insurance company will be in substantially the same form as the SAMPLE INSURANCE FORM LETTER, which is also included in Attachment B. 11. SHIPMENT A. Supplier's quote shall be F.O.B. City of Vernon, Soto Yard located at 2800 Soto Avenue, Vernon Ca 90058. B. Transformers will be delivered on a flatbed truck for side unloading by forklift at ground level. C. Supplier shall notify City 48 hours prior to delivery. All delivery shall be Monday -Friday, 7:30 AM to 3:00 PM. Contact telephone is (323) 589- 9498 or (323) 585-5192. D. 15 days prior to shipment, supplier shall furnish certified test reports of the switch. E. 15 days prior to shipment, supplier shall furnish three (3) sets of Operations/Instruction Manuals. 15 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 12. WARRANTY Supplier shall provide warranty for a minimum of twelve (12) months after delivery. 16 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS ATTACHMENT B INSURANCE SCHEDULE (Vendor) The Contractor shall provide proof of insurance, including a standard certificate of insurance, in at least the following amounts and coverage (combined single limit permitted): Coverage and Limits Bodily Injury Property Damage Hazards Each Person Each Accident Each Accident Automobile Liability Owned Automobiles $500,000 $1,000,000 $500,000 Hired Automobiles $500,000 $1,000,000 $500,000 Non -Owned Automobiles $500,000 $1,000,000 $500,000 Workers' Compensation $ Statutory Employers' Liability $1,000,000 per employer II. General Liability Premises Operations $1,000,000 $2,000,000 $1,000,000 Elevators (if applicable) $1,000,000 $2,000,000 $1,000,000 Independent Contractors $1,000,000 $2,000,000 $1,000,000 Products — Completed $1,000,000 $2,000,000 $1,000,000 Operations Contract Liability $1,000,000 $2,000,000 $1,000,000 Umbrella Liability $4,000,000 $1,000,000 $1,000,000 The general liability policy shall contain the following special endorsements which shall be noted on or attached to the standard certificate of insurance: An endorsement naming City, its officers, and employees as insureds under the policy. An endorsement providing City thirty (30) days notice of cancellation or material reduction of coverage. An endorsement providing coverage for all operations under City permit and specifying the activities covered. Such other endorsement as may be required by addendum hereto. In addition to the standard certificate of insurance, proof of general and umbrella liability coverage shall be furnished in the form checked below. Certification of the following proofs by the insurance agent or broker will not be accepted: For each policy, a notarized letter from the underwriter or carrier certifying that the coverage and statements in the standard certificate of insurance (attached thereto) are true and correct and that the signator is an officer authorized to so certify. A copy of each policy certified by an officer of the underwriter or carrier and notarized. 18 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS SAMPLE INSURANCE FORM LETTER (To be issued on insurance carrier letterhead. This letter must be notarized). Date: City of Vernon ("City") 4305 Santa Fe Avenue Vernon, CA 90058 Attn: Risk Management Department Re: Insurance for City of Vernon (description of permit or contract) Policy Number(s) Named Insured: City Clerk: I hereby certify that the certificate of insurance attached hereto and made a part hereof by reference truly and accurately represents the above -cited insurance policies and the insurance coverage of each for the named insured issued by (insurance carrier). The City of Vernon, its officers, and employees are included in said policies as additional insureds and the City of Vernon will be.provided with thirty (30) days written notice of cancellation or material reduction of coverage. I certify that I am an officer of the insurance carrier named herein and that I am authorized to sign this certificate on behalf of said insurance carrier. Signature Title 03/03 19 of 19 Prepared by: Approved by SPECIFICATION NO. TR1-2003 Approved Manufacturers/Suppliers Cooper Power c/o Mark Christensen Utility Products 44-909 Golf Center Pkwy, Suite #12 Indio, CA 92201 Phone: (760) 863-1660 2. ABB Inc. Attn: Jeff Vivian 2945 Harding Street, Suite 207 Carlsbad, CA 92008 Phone: (760) 720-3156 3. Howard Transformers c/o Young and Company 530 South Marengo Ave Pasadena, CA 91101 Phone: (626) 795-9955 4. General Electric Company c/o Southwest Power 9837 Pioneer Blvd. Santa Fe Springs, CA 90670 Phone: (562)801-4577 5. Central Moloney c/o Southcoast Utility Sales 8762 Luss Drive Huntington Beach, Ca 92646 (Phone): (714) 962-0841 Fax: 714-963-2487 6. Kuhlman Electric Corp. 101 Kuhlman Road Versailles, KY 40383 (Phone): (800) 395-6932 Fax: 859-873-8032 Kenneth DeDario, P.E. Director of Light and Power