RESOLUTION NO. 8383
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF
VERNON ACCEPTING THE BID OF WESCO DISTRIBUTION,
INC., CENTRAL MOLONEY, INC. AND SOUTHWEST POWER
INC. ON BID NO. 1432 FOR THE PURCHASE OF OVERHEAD
DISTRIBUTION TRANSFORMERS FOR THE LIGHT AND POWER
DEPARTMENT AND APPROVING AND AUTHORIZING THE
EXECUTION OF EQUIPMENT PURCHASE CONTRACT AND THE
ISSUANCE OF A PURCHASE ORDER RESPECTING SAID BIDS
WHEREAS, the Light & Power Department is in need of various
one -phase, 60 Hz, mineral oil filled, overhead type distribution
transformers (the "Transformers") to replenish the stock for projected
service requirements for fiscal year 2003-2004; and
WHEREAS, pursuant to Resolution No. 8324 adopted by the City
Council of the City of Vernon on December 3, 2003, the City Clerk was
directed to give notice inviting sealed proposals or bids for the
purchase of the Transformers in accordance with a bid specification
provided by the Light and Power Department; and
WHEREAS, based upon the bid specification, the Purchasing
Department prepared Bid No. 1432 dated December 11, 2003, and sealed
bids were opened on January 8, 2004; and
WHEREAS, the Light & Power Department reviewed the bids
received and approved the bids based upon their analysis of the total
ownership cost of each bid in accordance with the bid specification;
and
WHEREAS, by letter dated February 9, 2004, Bruce V.
Malkenhorst, the City Administrator/City Clerk, recommended that Bid
No. 1432 be awarded based on a total ownership cost analysis to the
28 11 following:
t
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
WESCO Distribution, Inc. for the sum of $31,746.00 (37
Transformers);
Central Moloney, Inc. for the sum of $6,303.00 (3
Transformers); and
Southwest Power Inc. (General Electric Co.) for the sum of
$20,595.00 (31 Transformers).
NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE
CITY OF VERNON AS FOLLOWS:
SECTION 1: The City Council of the City of Vernon hereby
finds and determines that the recitals contained hereinabove are true
and correct.
SECTION 2: The City Council of the City of Vernon hereby
awards Bid No. 1432 to WESCO Distribution, Inc., Central Moloney, Inc.
and Southwest Power Inc. and accepts and approves the Equipment
Purchase Contract with WESCO Distribution, Inc., a copy of which is
attached hereto as Exhibit "A" and made a part hereof.
SECTION 3: The City Council of the City of Vernon hereby
authorizes the issuance of a purchase order for the purchase of the
Transformers pursuant to Bid No. 1432.
SECTION 4: All other bids in connection with Bid No. 1432
are rejected.
SECTION 5: The City Clerk of the City of Vernon shall
certify to the passage of this resolution, and thereupon and
thereafter the same shall be in full force and effect.
APPROVED AND ADOPTED this 18th day of February, 2004.
-tEONIS C. MALBURG, kayor
AT T E---
BRUCE V. MALKENHORST, City Clerk
- 2 -
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
t
STATE OF CALIFORNIA )
ss
COUNTY OF LOS ANGELES )
I, BRUCE V. MALKENHORST, City Clerk of the City of Vernon, do
hereby certify that the foregoing Resolution, being Resolution No.
8383, was duly adopted by the City Council of the City of Vernon at a
regular meeting of the City Council duly held on Wednesday,
February 18, 2004, and thereafter was duly signed by the Mayor of the
City of Vernon.
(SEAL)
o'
BRUCE V. MALKENHORST, City Clerk
- 3 -
EXHIBIT
0
s
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
EQUIPMENT PURCHASE CONTRACT
THIS AGREEMENT is made, entered into and executed in
duplicate originals, either copy of which may be considered and used
as the original hereof for all purposes, as of this day of
February, 2004, in the City of Vernon, County of Los Angeles,
California
BY AND BETWEEN
THE CITY OF VERNON
(hereinafter referred to as
the "City")
4305 Santa Fe Avenue
Vernon, CA 90058
WESCO DISTRIBUTION, INC.
(hereinafter referred to as
"WESCO")
10020 Freeman Avenue
Santa Fe Springs, CA 90670
WHEREAS, on December 11, 2003, the City requested proposals
or bids for 115 various one -phase, 60 Hz, mineral oil filled, overhead
type distribution transformers (the "Transformers") (Bid No. 1432)
needed by the City's Light and Power Department; and
WHEREAS, the City is permitted to accept or reject any or
all quotations received on the bid items; and
WHEREAS, on or about January 8, 2004, the City received
various proposals for the sale of the Transformers identified in Bid
No. 1432, with each of the 115 bid items quoted separately; and
WHEREAS, on January 5, 2004, WESCO, submitted a bid; and
WHEREAS, on January 8, 2004, the City opened the bid
submitted by WESCO, as well as other bids for the items identified in
Bid No. 1432; and
WHEREAS, the City desires to purchase the following bid
1 items from WESCO: three (3) 25 KVA, 7.2 KV 120/240V Transformers; five
2 (5) 37.5 KVA, 7.2 KV 120/240V Transformers; six (6) 50 KVA, 7.2 KV
3 120/240 V Transformers; six (6) 75 KVA, 7.2 KV 120/240V Transformers;
4 eight (8) 25 KVA, 7.2 KV 277/480 Transformers; six (6) 50 KVA, 7.2 KV
5 277/480 Transformers; and three (3) 250 KVA, 7.2 KV 277/480
6 Transformers for a total of thirty-seven (37) Transformers per City of
7 Vernon Specification No. TR1-2003.
8 NOW, THEREFORE, THE PARTIES HERETO DO MUTUALLY AGREE AS SET
9 FORTH HEREIN:
10 1. Purchase. WESCO agrees to sell and deliver to the
11 City a total of thirty-seven (37) Transformers referenced above
12 pursuant to City of Vernon Specification No. TR1-2003, as identified
13 in WESCO's January 5, 2004 bid and which meet the specifications
14 contained in City of Vernon Bid No. 1432, dated December 11, 2003
15 (collectively referred to as the "Bid Documents"). A copy of the Bid
16 Documents are attached hereto as Exhibit "A" and incorporated herein
17 by reference.
18 2. Time of Performance. WESCO's performance shall
19 commence upon the full execution of this Contract and delivery of the
20 transformers and shall be completed by WESCO within 16 weeks after
21 receipt of order.
22 3. Price. The City agrees to purchase thirty-seven (37)
23 Transformers from WESCO for the total sum of Thirty -One Thousand Seven
24 Hundred Forty -Six Dollars and No Cents ($31,746.00). This price
25 includes freight and excludes sales tax.
26 4. Delivery. Consistent with the Bid Documents, WESCO
27 agrees to deliver the thirty-seven (37) Transformers on a flatbed
28 truck for side unloading by forklift at ground level to the City.
-2-
1 WESCO shall notify the City 48-hours prior to delivery at (323) 589-
2 9498 to make arrangements for gates to be opened. Delivery shall be
3 scheduled for Monday through Friday between the hours of 7:30 a.m. and
4 3 p.m. Prior to shipment, WESCO shall furnish certified test results
5 of the switch and three (3) sets of Operations/Instruction Manuals.
6 5. Warranties. WESCO warrants title to the Transformers
7 purchased hereunder and any part thereof to be free of any claim or
8 any security interest, lien or encumbrance. WESCO also warrants that
9 the Transformers will be delivered new and shall be free from defects.
10 WESCO shall provide, at a minimum, a one (1) year labor and material
11 warranty to begin upon acceptance of the Transformers by the City.
121 All manufacturers' warranties, any warranties typically provided by
13 WESCO and any other warranties made applicable by law shall apply to
14 the City's purchase of the Transformers.
15 6• Governing Law. The validity, interpretation and
161 Performance of this Contract shall be controlled and construed under
17 the laws of the State of California.
18 7. Forum Selection. Any action brought relating to this
19 Contract shall be brought and held exclusively in a State Court in the
20 County of Los Angeles, California.
21 8. Notices. Notices to the parties, unless otherwise
22 requested in writing, shall be sent to:
23 City: THE CITY OF VERNON
ATTN: DOLORES FONSECA
24 PURCHASING ASSISTANT
4305 SANTA FE AVENUE
25 VERNON, CA 90058-0805
26 WESCO: WESCO DISTRIBUTION, INC.
ATTN: LESLIE MCCOY
27 BRANCH OPERATIONS MANAGER
10020 FREEMAN AVENUE
28 SANTA FE SPRINGS, CA 90670
-3-
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19'
20
21
22
23
24
25
26
27
28
9. Risk of Loss. Title and risk of loss or damage shall
pass to the City and delivery shall be deemed to be complete upon
delivery FOB jobsite or upon moving into storage at the City's
request, whichever occurs first.
10. Attorneys' Fees. In the event that it becomes
necessary for either party to this Agreement to enforce any of the
provisions of this Agreement, the parties agree that a court of
competent jurisdiction may determine and fix reasonable attorney's
fees to be paid to the successful litigant.
IN WITNESS WHEREOF, the parties have caused this Agreement
to be executed by and through their authorized officers on the date,
month and year first written above.
ATTEST:
BRUCE V. MALKENHORST, City Clerk
APPROVED AS TO FORM:
ERIC T. FRESCH, City A torney
IM
CITY OF VERNON
LEONIS C. MALBURG, Mayor
WESCO DISTRIBUTION, INC.
By:
Title:Gnc�
By:
Y �
Title: A cs � r-ccTo�'
-4-
REQUEST FOR QUOTATIONS
NOT A PURCHASE ORDER
DIRECT ALL INQUIRIES TO:
CITY PURCHASING AGENT
TELEPHONE (323) 583-8811
CITY OF VERNON, CALIFORNIA
PURCHASING DEPARTMENT
CITY HALL .
4305 Santa Fe Ave. - Vernon, California 9fm,R
ABB
TO: Mr. Greg Tagliaferri
C/o Wesco is ri u ion, Inc.,
10020 Freeman Avenue
Santa -Fe Springs, CA 90670
FOR CITY USE ONLY
QUOTATION NO. 1432
DATE MAILED 1 _
REC'D BY CITY bl /09/ V g
Please quote hereon the lowest net price you can furnish the articles or services specified below. Quote on each item separately. Bidder may
qualify quotations as "ail or none by stating so on body of form. City reserves the right to accept or reject quotations received on any or all
items. In order to maintain their name on City's Bidder File. Vendor should return thin form whPrhar a nri. n 1. ,, -f-A — __*
QUANTITY
DESCRIPTION
NET UNIT PRICE
TOTAL
Overhead type distribution transformers, as per
City of Vernon Light & Power Specification No. TR1-2003
dated November 19, 2003.
F —3
25 KVA, 7.2 KV 120/240V
Z(cl
Overhead Transformer
`J73
-o
—5
37.5 KVA, 7.2 KV,
120/240 V Overhead Transformer
��
00
3qyD
Co
50 KVA, 7.2 KV,
120/240 V Overhead Transformer
747
are
L/ f 92-
oa
°A_6
75 KVA, 7.2 KV,
120/240 V Overhead Transformer
930
cG
��j ?
25 KVA, 7.2 KV,
277/480 Y Overhead Transformer
°o
=6
50 KVA, 7.2 KV,
277/480 Y Overhead Transformer
�73g
c"
f-3
250 KVA, 7.2 KV,
277/480 Y Overhead Transformer
-----------PLEASE NOTE ----------
Bid number must be indicated on the outside
of the envelope; otherwise, bid will not be
accepted.
IF INSUFFICIENT SPACE PROVIDED ABOVE FOR PROPOSAL, ATTACH RIDER OR SUPPLEMENT. CASH DISCOUNTS
QUOTED FOR PERIODS OF LESS THAN 30 DAYS WILL NOT BE CONSIDERED WHEN ORDER
IS AWARDED, BIDS
RECEIVED IN RESPONSE TO THIS REQUEST FQ� QUOTATION WILL BE OPENE CITY PUR HA 1 G AGENTS
OFFICE ON THE 8 th DAY OF iJ d n u a ry ; �g
20 AT-- (p
NOTE: Quote prices exclusive of Sales Tax and Excise T e .
A. Indicate Sales Tax in this space $.....Tt. ? d.: .i....................... B. Indicate Excise Tax in this space $ .....................................................
...............
B. Above quotations subject to Cash Discount f...... tQ 1',...,,,e. _
C. To be delivered to CITY OF VERNON at.....`t�. . ... {' ..a w r ) t?r n0 pEY
We (1) agree to furnish above in .........................................days from receipt of purchase order at prices specified,
FOR..............................
...............\ ..........�.....��.5�...r,.by.',Ior..TY?c:...................
// Fi Name
DATE...........l....O............................HERE
\ yy 1
SIGN HERE....... (.c�� �r►1l;. Ls�.� �... G
MAIL TO PURCHASING DEPT. r `"� ` �' 0 P` ' ,,A, b'A ' A.)
REQUEST FOR QUOTATIONS
NOT A PURCHASE ORDER
DIRECT ALL INQUIRIES TO:
CITY PURCHASING AGENT
TELEPHONE (323) 583-8811
TO:
CITY OF VERNON, CALIFORNIA
PURCHASING DEPARTMENT
CITY HALL
4305 Santa Fe Ave. - Vernon, California 90058
FOR CRY USE ONLY
QUOTATION NO.
DATE MAILED
REC'D BY CITY
OPENED
BY
Please quote hereon the lowest net price you can furnish the articles or services specified below. Quote on each item separately. Bidder may
qualify quotations as "all or none" by stating so on body of form. City reserves the right to accept or reject quotations received on any or all
items. In order to maintain their name on Citv's Bidder Files, Voandnr chmow rn♦,,.., +t l 4,..,,.....k- &.-- - ____ __ ------
20
NOTE: Quote prices exclusive of Sales Tax and Excise Taxes.
A. Indicate Sales Tax in this space$.................................................................... B. Indicate Excise Tax in this space $...........................
..........................
B. Above quotations subject to Cash Discount of .................................................%, F.O.BC. ..............................................................
...................................
To be delivered to CITY OF VERNON at .....................
We (1) agree to furnish above in .........................................days from receipt of purchase order at
..... -- specified.
FOR ..............
Fm! t Kamm
�...1�..s.:.......................................
(,� n N
DATE......... ..`�...r.Je
SIGNHERE ......................................................
.�.......................................................
MAIL TO PURCHASING DEPT. Lcs ` �`
REQUEST FOR QUOTATIONS
NOT A PURCHASE ORDER
DIRECT ALL INQUIRIES TO:
CITY PURCHASING AGENT
TELEPHONE (323) 683-8811
TO:
CITY OF VERNON, CALIFORNIA
PURCHASING DEPARTMENT
CITY HALL
4305 Santa Fe Ave. - Vernon, California 90058
I FOR CITY USE ONLY
QUOTATION NO.
DATE MAILED
REC'D BY CITY
Please quote hereon the lowest net price you can fumish the articles or services specified below. Quote on each item separately. Bidder may
qualify quotations as "all or none" by stating so on body of form. City reserves the right to accept or reject quotations received on any or all
items. In order to maintain their name on City's Bidder File, Vendor should return this form whether a nrirp is n„ntprl nr n.,r
QUANTITY
DESCRIPTION
NET UNIT PRICE
TOTAL
If you have any questions regarding the bid or the
attached specifications, please call Jose Lugo (Electrical
Engineer) at (323) 583-8811, ext. 276.
------------PLEASE NOTE ----------
Bid number must be indicated on the outside
of the envelope; otherwise, bid will not be
accepted.
IF INSUFFICIENT SPACE PROVIDED ABOVE FOR PROPOSAL, ATTACH RIDER OR SUPPLEMENT. CASH DISCOUNTS
QUOTED FOR PERIODS OF LESS THAN 30 DAYS WILL NOT BE CONSIDERED WHEN ORDER IS AWARDED. BIDS
RECEIVED IN RESPONSE TO THIS REQUEST FOR QUOTATION WILL BE OPENED IN CITY PURCHASING AGENT'S
OFFICE ON THE DAY OF 20 AT
NOTE: Quote prices exclusive of Sales Tax and Excise Taxes.
A. Indicate Sales Tax in this space$....................................................................B. Indicate Excise Tax in this space $ .....................................................
B. Above quotations subject to Cash Discount of .................................................%, F.O.BC. ....................................................................................
..............
To be delivered to CITY OF VERNON at............................................................................
We (I) agree to furnish above in .........................................days from receipt of purchase order atp c Is
specified. n
FOR..................... `�E�iO........ 4S..rl.......t........... t7f..,.....................................
t Finn Name
DATE.........F..!!•••�.............................. SIGN HERE.......` `:�°:` v.............................. tsi.t�.s.....S.:.t . .................
MAIL TO PURCHASING DEPT. k r'^ J O�`' ` "ter
12-23-2003
To: LISA GROVES WESCO SANTA FE SPRINGS
LISA RE YOUR REQUEST FOR BELOW CUSTOMER DTD 12/12 ATHENS QUOTES AS FOLLOWS,
PRICES FIRM IN TRUCKLOAD RELEASES THRU 12/31/04.
REF ATHENS NEG NO: SF121631 City of Vernon
Contract Effective Date: 12/23/2003
Contract Expiration Date: 12/31 /2004
PLS QUOTE:
Shipment Period: 0 1 /0 1/2001-06/30/2001
ITEM QTY PRODUCT
ID
1 3 A7312W25ZZM1631
CustProduct-ID: 001-0251
Overhead Distribution Transformer; S - Conventional
25 KVA
No Load: 50 Watts at 85 degrees C; Load: 362 Watts at 85 degrees C; Total Loss: 412 Watts
7200/12470Y HV; 95 BIL; Copper HV Winding Mal
With Taps at 7560, 7380, 7020, 6840
120/240 LV; 30 * 30 BIL; Non-LV Interlaced, Aluminum LV Winding Mad
60 Hz
1 Phase
Transformer Weight: 352.131bs.; Height: 39 in.; Width: 20.00 in.; Depth: 24.00 in.
Est. Shipping Dimensions: 366.131bs. Height: 43 in.; Width: 24 in.; Length: 25 in.;
Est. C/C Weight: 191.8 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
I HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt
3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain
13.3 Gal(s) of Transformer Oil
1 15.25" Carbon STL Cover, 2 HV Bushing Holes
2 5 A7312W37ZZM1631
CustProduct-ID: 001-03 71
Overhead Distribution Transformer; S - Conventional
37.5 KVA
No Load: 85 Watts at 85 degrees C; Load: 420 Watts at 85 degrees C; Total Loss: 505 Watts
7200/12470Y HV; 95 BIL; Copper HV Winding Matl
With Taps at 7560, 7380, 7020, 6840
120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mad
60
1 Phase
Transformer Weight: 466.99 lbs.; Height: 39 in.; Width: 22.00 in.; Depth: 27.00 in.
Est. Shipping Dimensions: 487.99 lbs. Height: 43 in.; Width: 26 in.; Length: 26 in.;
Est. C/C Weight: 262.35 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt
3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain
17.4 Gal(s) of Transformer Oil
1 17.5" Carbon STL Cover, 2 HV Bushing Holes
A7312W50ZZM1631
CustProduct-ID: 001-0501
Overhead Distribution Transformer; S = Conventional
50 KVA
No Load: 86 Watts at 85 degrees C; Load: 605 Watts at 85 degrees C; Total Loss: 691 Watts
7200/12470Y HV; 95'BIL; Copper HV Winding Matl
With Taps at 7560, 7380, 7020, 6840
120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl
60 Hz
1 Phase /
Transformer Weight: 592.85 lbs.; Height: 48 in.; Width: 22.00 in.; Depth: 27.00 in.
Est. Shipping Dimensions: 613.85 lbs. Height: 52 in.; Width: 26 in.; Length: 26 in.;
Est. C/C Weight: 306.44 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt
I HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt
3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain
25.8 Gal(s) of Transformer Oil
1 17.5" Carbon STL Cover, 2 HV Bushing Holes
4 6 - A7312W75ZZM1631
CustProduct-ID: 001-0751
Overhead Distribution Transformer; S - Conventional
75 KVA
No Load: 144 Watts &85 degrees C; Load: 779 Watts at 85 degrees C; Total Loss: 922 Watts
7200/12470Y HV; 95 BIL; Copper HV Winding Mad
With Taps at 7560, 7380, 7020, 6840
120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mad
60 Hz
1 Phase
w�
Transformer Weight: 840.981bs.; Height: 52 in.; Width: 25.00 in.; Depth: 31.00 in.
Est. Shipping Dimensions: 872.98 lbs. Height: 56 in.; Width: 32 in.; Length: 33 in.;
Est. C/C Weight: 412.26 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt
3 LV Bushings, Eye Bolt for #1-500MCM, Porcelain
39 Gal(s) of Transformer Oil
1 20" Carbon STL Cover, 2 HV Bushing Holes
A7352W25ZZM1631
CustProduct-ID: 001-0252
Overhead Distribution Transformer; S - Conventional
25 KVA
No Load: 51 Watts at_Z degrees C; Load: 341 Watts at 85 degrees C; Total Loss: 392 Watts
7200/12470Y HV; 95 BIL; Aluminum HV Winding Mad
With Taps at 7560, 7380, 7020, 6840
277/480Y LV; 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl
60 Hz
I Phase
Transformer Weight: 461.79 lbs.; Height: 39 in.; Width: 22.00 in.; Depth: 26.00 in.
Est. Shipping Dimensions: 422.79 lbs. Height: 43 in.; Width: 26 in.; Length: 26 in.;
Est. C/C Weight: 198.42 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt
I HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt
2 LV Bushings, Eye Bolt for #6-4/0, Porcelain
17.8 Gal(s) of Transformer Oil
1 17.5" Carbon STL Cover, 2 HV Bushing Holes
6 6 A7352W50ZZM1631
CustProduct-ID: 001-0502
Overhead Distribution Transformer; S - Conventional
50 KVA
No Load: 88 Watts 05 degrees C; Load: 557 Watts at 85 degrees C; Total Loss: 645 Watts
7200/12470Y HV; 95 B1L; Copper HV Winding Mad
With Taps at 7560, 7380, 7020, 6840
277/480Y LV; 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mad
60 Hz
1 Phase
Transformer Weight: 561.96 lbs.; Height: 44 in.; Width: 22.00 in.; Depth: 26.00 in.
Est. Shipping Dimensions: 582.96 lbs. Height: 48 in.; Width: 26 in.; Length: 26 in.;
Est. C/C Weight: 315.26 lbs.
65 Temp. Rise;.
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt
2 LV Bushings, Eye Bolt for #2-350MCM, Porcelain
21.4 Gal(s) of Transformer Oil
1 17.5" Carbon STL Cover, 2 HV Bushing Holes
A7352W52ZZM1631
CustProduct-ID: 001-2502
Overhead Distribution Transformer; S - Conventional
250 KVA
No Load: 299 Watt�,at 85 degrees C; Load: 1998 Watts at 85 degrees C; Total Loss: 2297 Watts
7200/12470Y HV; 95 BIL
With Taps at 7560, 7380, 7020, 6840
277/480Y LV; 30 BIL; Non-LV Interlaced
60 Hz
1 Phase ,/
Transformer Weight: 1744.77 lbs.; Height: 57 in.; Width: 39.00 in.; Depth: 33.00 in.
Est. Shipping Dimensions: 1817.77 lbs. Height: 61 in.; Width: 30 in.; Length: 30 in.;
Est. C/C Weight: 919.3 lbs.
65 Temp. Rise;
1 HV Tap Chgr, ABB, Ext (lever) setscrew lockable handle, 5 Po
1 HV Line Bushing, 125kV BEL, 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
2 LV Bushings, 4 Hole "H" spade, Porcelain 1" STUD
65 Gal(s) of Transformer Oil
1 24" Carbon STL Cover, 2 HV Bushing Holes
12 A1612W25ZZM1631
CustProduct-ID: 002-0251
Overhead Distribution Transformer; S - Conventional
25 KVA
No Load: 57 Watts at 85 degrees C; Load: 323 Watts at 85 degrees C; Total Loss: 380 Watts
16340 HV4 5 BIL; Aluminum HV Winding Mad
tt ,, g
With Taps`a 200, 16770, 15910, 15480
120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mad
60 Hz
1 Phase
Transformer Weight: 404.9 lbs.; Height: 38 in.; Width: 22.00 in.; Depth: 27.00 in.
Est. Shipping Dimensions: 425.9 lbs. Height: 42 in.; Width: 26 in.; Length: 26 in.;
Est. C/C Weight: 202.83 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
I HV Line Bushing, 125kV BIL., 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain
17.6 Gal(s) of Transformer Oil
1 17.5" Carbon STL Cover, 2 HV Bushing.1joles
9 21 A1612W50ZZMKransformer;
CustProduct-ID:
Overhead DistribS - Conventional
50 KVA
No Load: ; Load: 620 Watts at 85 degrees C; Total Loss: 706 Watts
16340 HV,95 Bnding Mad
With Taps 17 , 16770, 15910, 15480
120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl
60 Hz
I Phase
Transformer Weight: 593.6 lbs.; Height: 48 in.; Width: 22.00 in.; Depth: 27.00 in.
Est. Shipping Dimensions: 614.6 lbs. Height: 52 in.; Width: 26 in.; Length: 26 in.;
Est. C/C Weight: 308.65 tbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
I HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, 125kV BIL., 17.75"Creep, 8-2 size eyebolt
3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain
25.6 Gal(s) of Transformer Oil
1 17.5" Carbon STL Cover, 2 HV Bushing Holes
10 3 A1612W67ZZM1631r
CustProduct-ID: 002-1671
Overhead Distribution T_ raniformer; S -Conventional
167 KVA
No Load: 2jW" at 85 degrees C; Load: 1616 Watts at 85 degrees C; Total Loss: 1841 Watts
16340 HV; B ;Aluminum HV Winding Matl
With Taps 00, 16770, 15910, 15480
120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mad
60 Hz /
I Phase
Transformer Weight: 1379.86 lbs.; Height: 48 in.; Width: 39.00 in.; Depth: 37.00 in.
Est. Shipping Dimensions: 1452.86 lbs. Height: 52 in.; Width: 38 in.; Length: 44 in.;
Est. C/C Weight: 718.71 lbs.
65 Temp. Rise;
I HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
I HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
4 LV Bushings, 4 Hole "H" spade, Porcelain V STUD
50 Gal(s) of Transformer Oil
1 24" Carbon STL Cover, 2 HV Bushing Holes
11 6 A1652WIOZZM1631 k
CustProduct-ID: 002-0102
Overhead Distribution T er; S -Conventional
10 KVA
No Load: 23 W at 85 degrees C; Load: 153 Watts at 85 degrees C; Total Loss: 176 Watts
16340 HVI 95 ; Copper HV Winding Mat]
With Taps kt4 '200, 16770, 15910, 15480
277/480Y LV; 30 BIL; Non-LV Interlaced; Copper LV Winding Matl
60 Hz
1 Phase
Transformer Weight: 257.22 lbs.; Height: 36 in.; Width: 18.00 in.; Depth: 22.00 in.
Est. Shipping Dimensions: 268.22 lbs. Height: 40 in.; Width: 22 in.; Length: 23 in.;
Est. C/C Weight:.138.89 lbs.
65 Temp. Rise;
I HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
2 LV Bushings, Eye Bolt for #6-4/0, Porcelain
9.4 Gal(s) of Transformer Oil
1 13.25" Carbon STL Cover, 2 HV Bushing Holes
12 7 A1652W15ZZM1631 ">
CustProduct-ID:002-0152
Overhead Distribution Transformer; S.- Conventional
15 KVA
No Load: 3h'VP at 85 degrees C; Load: 186 Watts at 85 degrees C; Total Loss: 217 Watts
163407
6340 HV 95
With Taps a 00, 16770, 15910, 15480
277/480Y LV; 30 BIL; Non-LV Interlaced
60 Hz
1 Phase
Transformer Weight: 344.28 lbs.; Height: 36 in.; Width: 20.00 in.; Depth: 24.00 in.
Est. Shipping Dimensions: 358.28 lbs. Height: 40 in.; Width: 24 in.; Length: 25 in.;
Est. C/C Weight: 194 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
2 LV Bushings, Eye Bolt for #64/0, Porcelain
12.3 Gal(s) of Transformer Oil
1 15.25" Carbon STL Cover, 2 HV Bushing Holes
13 12 A1652W37ZZM1631 ,
CustProduct-ID:002-0372 i
Overhead Distribution Transformer; 'S - Conventional
37.5 KVA
No Load: , "Watts at 85 degrees C; Load: 430 Watts at 85 degrees C; Total Loss: 513 Watts
16340 95 ; Copper HV Winding Matl
With TapsNqW200, 16770, 15910, 15480
277/480Y LV; 30 BIL; Non-LV Interlaced-, Aluminum LV Winding Mad
60 Hz
1 Phase
Transformer Weight: 464.63 lbs.; Height: 38 in.; Width: 22.00 in.; Depth: 26.00 in.
Est. Shipping Dimensions: 485.63 lbs. Height: 42 in.; Width: 26 in.; Length: 26 in.;
Est. C/C Weight: 260.15 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, 125kV BIL., 17.75"Creep, 8-2 size eyebolt
I HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
2 LV Bushings, Eye Bolt for #2-350MCM, Porcelain
17.4 Gal(s) of Transformer Oil
1 17.5" Carbon STL Cover, 2 HV Bustling Holes
14 6 A1652W5072M1631
CustProdud-ID: 002-05
Overhead Distn ransformer; S - Conventional
50 KV
No YY
Watts at 85 degrees C; Load: 543 Watts at 85 degrees C; Total Loss: 638 Watts
1635 BIL; Copper HV Winding Matl
Wit 17200, 16770, 15910, 15480
V; 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl
60 Hz
1 Phase
Transformer Weight: 563.57 lbs.; Height: 44 in.; Width: 22.00 in.; Depth: 26.00 in.
Est. Shipping Dimensions: 584.57 lbs. Height: 48 in.; Width: 26 in.; Length: 26 in.;
Est. C/C Weight: 315.3 lbs.
65 Temp. Rise;
I HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, 125kV BIL., 17.75"Creep, 8-2 size eyebolt
2 LV Bushings, Eye Bolt for #2-350MCM, Porcelain
21.6 Gal(s) of Transformer Oil
1 17.5" Carbon STL Cover, 2 HV Bushing Holes
15 11 A1652W997ZM1631
CustProduct-ID:002-1002
Overhead Distribution Tpsformer; S - Conventional
100 KVA
No Load: 1 - . at 85 degrees C; Load: 818 Watts at 85 degrees C; Total Loss: 993 Watts
16340 HV 95 B , Copper HV Winding Matl
With Taps 13M, 16770, 15910, 15480
277/480Y L , 0 BIL; Nan-LV Interlaced; Aluminum LV Winding Mat]
60 Hz
1 Phase
Transformer Weight: 1088.11 lbs.; Height: 52 in.; Width: 27.00 in.; Depth: 33.00 in.
Est. Shipping Dimensions: 1152.11 lbs. Height: 56 in.; Width: 36 in.; Length: 40 in.;
Est. C/C Weight: 557.77 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
1 HV.Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
2 LV Bushings, Double Eye Bolt for 2/0-1000MCK Porcelain
48 Gal(s) of Transformer Oil
1 22" Carbon STL Cover, 2 HV Bushing Holes
Item R X Imp Iexc RegPF* Reg Reg@
Reg@ EAU* Eff
Eff@ Ewa
.80 PF
1.0 PF
50%PU 100%PU
1 1.45 1.87 2.37 0.52 0.80 2.29 2.29
1.47 100.00 98.38
98.89 98.38
2 1.12 1.93 2.23 0.73 0.80 2.06 2.06
1.14 100.00 98.67
99.00 98.67
3
1.21
1.87
2.23
0.45
0.80
2.09
2.09
1.23
100.00
98.64
99.06
98.64
4
1.04
1.98
2.24
0.59
0.80
2.03
2.03
1.06
100.00
98.79
99.11
98.79
5
1.36
1.82
2.27
0.46
0.80
2.18
2.18
1.38
100.00
98.46
98.92
98.46
6
1.11
1.94
2.24
0.47
0.80
2.06
2.06
1.13
100.00
98.73
99.10
98.73
7
0.80
2.81
2.92
0.43
0.80
2.34
2.34
0.84
100.00
99.09
99.37
99.09
8
1.29
1.87
2.27
0.54
0.80
2.16
2.16
1.31
100.00
98.50
98.91
98.50
9
1.24
2.00
2.35
0.45
0.80
2.19
2.19
1.26
100.00
98.61
99.05
98.61
10
0.97
2.62
2.79
0.34
0.80
2.36
2.36
1.00
100.00
98.91
99.25
98.91
11
1.53
1.64
2.24
0.49
0.80
2.21
2.21
1.54
100.00
9827
98.79
98.27
12
1.24
1.85
2.23
0.43
0.80
2.11
2.11
1.26
100.00
98.57
98.98
98.57
13
1.15
1.92
2.24
0.67
0.80
2.08
2.08
1.17
100.00
98.65
98.99
98.65
14
1.09
1.95
2.23
0.56
0.80
2.04
2.04
1.10
100.00
98.74
99.09
98.74
15
0.82
2.09
2.24
0.60
0.80
1.91
1.91
0.94
100.00
99.02
99.25
99.02
(*)From Customer Specifications
Item
Eff@
Efl@
Eff@
EfI@
EM,
Reg@
Reg@
Reg@
NL@
NL@
EXI@
EXI@
25%
50%
75%
1000/9
125%
.8PF
9PF
LOPF
105%
110%
105%
110%
1
98.85
98.89
98.67
98.38
98.07
2.29
2.13
1.47
59.00
70.00
0.72
1.18
2
98.83
99.00
98.87
98.67
98.44
2.06
1.86
1.14
103.00
127.00
1.31
3.12
3
99.02
99.06
98.88
98.64
98.38
2.09
1.91
1.23
.101.00
121.00
0.65
1.09
4
98.98
99.11
98.98
98.79
98.57
2.03
1.81
1.06
174.00
214.00
1.03
2.39
5
98.86
98.92
98.72
98.46
98.17
2.18
2.02
1.38
58.00
67.00
0.56
0.72
6
99.03
99.10
98.94
98.73
98.49
2.06
1.86
1.13
104.00
125.00
0.68
1.19
7
99.33
99.37
99.25
99.09
98.92
2.34
1.97
0.84
365.00
453.00
0.80
2.20
8
98.78
98.91
98.74
98.50
98.23
2.16
1.98
1.31
66.00
77.00
0.70
1.02
9
99.01
99.05
98.85
98.61
98.34
2.19
1.99
1.26
101.00
121.00
0.65
1.09
10
99.23
99.25
99.10
98.91
98.70
2.36
2.03
1.00
264.00
314.00
0.47
0.77
11
98.71
98.79
98.57
98.27
97.95
2.21
2.09
1.54
26.00
28.00
0.56
0.64
12
98.88
98.98
98.81
98.57
98.31
2.11
1.93
1.26
34.00
38.00
0.50
0.60
13
98.84
98.99
98.86
98.65
98.42
2.08
1.88
1.17
100.00
122.00
1.12
2.46
14
98.98
99.09
98.94
98.74
98.51
2.04
1.83
1.10
114.00
139.00
0.90
1.80
15
99.10
99.25
99.16
99.02
98.85
1.91
1.66
0.84
213.00
265.00
1.15
3.03
EXCEPTIONS TAKEN TO CUSTOMER SPEC TR1-2003 Dated 11/19/2003
WE TAKE EXCEPTION TO PARA. 5.14 IN THAT WE FURNISH AN ANODIZED ALUMINUM NAMEPLATE
INSTEAD OF A STAINLESS STEEL
NAMEPLATE.
NOTES
PLEASE PUT DIVISION NEGOTIATION NUMBER, DIVISION NEGOTIATION ITEM NUMBER AND
COMPLETE 10 TO 15 CHARACTER STYLE NUMBER ON THE ORDER AT THE TIME OF ORDER ENTRY. IF
THIS INFORMATION IS NOT COMPLETE AND CORRECT, ORDER IS SUBJECT TO CANCELLATION.
"MODIFICATIONS TO THE QUOTED BILL OF MATERIAL MUST BE REVIEWED WITH ATHENS SALES
ENGINEER PRIOR TO ORDER ENTRY."
OVERHEAD TRANSFORMER LEAD TIMES FOR ITEMS NOT IN STOCK OR PRODUCTION ARE PER THE
CHART BELOW. THESE LEAD TIMES DO NOT INCLUDE THE TIME NECESSARY FOR THE DESIGN OR
ACQUISITION OF SPECIAL OR BOUGHT -OUTSIDE PARTS. ALL LEAD TIMES ARE FROM DATE OF
ORDER ENTRY AT ATHENS TO DATE OF SHIPMENT & ARE SUBJECT TO AVAILABLE PRODUCTION
SPACE AT ORDER ENTRY. CONTACT DMSION SALES ENGINEER FOR AVAILABILITY AND PRICE
ADJUSTMENT FOR SHORTER LEAD TIME. YOU MUST ENTER A COMPLETE 10 CHARACTER OR 15
CHARACTER STYLE NUMBER AT TIME OF ORDER ENTRY.
KVA
COREFORM 5 - 37.5 KVA
SHELL FORM 5 - 75 KVA
LARGE 100-1000 KVA
JUMBOS
3 PHASE
WEEKS
6 - 7 STYLES THAT BEGIN WITH K, L, M, & N
6 - 7 ALL OTHER STYLES
7-8
7-8
8
LEAD TIME SUBJECT TO AVAILABLE SPACE ARO.
NO LOAD LOSSES QUOTED ARE GUARANTEED AVERAGES AT 85 DEGREES CENTIGRADE.
OUR NAMEPLATE IS ENGRAVED AS FOLLOWS: "FILLED WITH MINERAL OIL THAT CONTAINED LESS
THAN 1 P.P.M. P.C.B. AT TIME OF MANUFACTURE".
GENERAL TERMS AND CONDITIONS OF SALE, PPIGTC073003 APPLY
rn....us.
tS Q
Ar CORD,u CERTIFICATE OF LIABILITY INSURANCEPRODUCER
'
01107104
The HOH Grog. Inc. PNhG
USX Toww, Suits 1100
600 Grant Street
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFO ATION
ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE
HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR
ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.
INSURERS AFFORDING COVERAGE
NAIC III
Pittsburgh, PA 152W2804
INSURED
WESCO hrtemationa�, Inc.
Four Station Square, Commerce CL N>e700
Pittsburgh, PA 15219
INSURER& Travelers i of UNn
25674
IISURERB: Tfal/Nefs Co. of COrN1eGiC
25682
*mxv R Q American Guarantee & Liability Ins.
26247
INSURER D:
COVERAGES
I SURER E:
THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE LSSUED OR
MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH
POLICIES, AGGREGATE LIMITS SHOYMM MAY HAVE BEEN REDUCED BY PAID CLAIMS,
TYPE OP I SURMICE
POLICY NUMBER
DATE
LI MITO
A
GENERA.
UABILITY
�0OWJERCKLGENEIWUAWrY
CLAMS MADE Q OCCUR
TC2JGLSA466K204ATI
O604103
OW04104
EACH OOCURREWW
$3,000,N
X
TO
MEDEXP — n
i300 00O
i1 000
—
PERSONAL & AM WMY
$1 000 000
GENERA, AGGREGATE
KOOO.000
GENRL AGGREGATE UMiT APPLIES PEP-1PRODUCTS
POLICY PRO LOC
JECT
- COMPIOP AGG
1201.0d�20
OOO 000
A
B
AUTOMOBILE
U ASILITY
ANYAUTO
ALL OWNED AUTOS
SCFiI�Ik ED AUTOS
I# MMTOS
NONOWEDAUTOS
Phys. Dam
TC2JCAP4661C2026 nL
TC2ECAP466K2038TCT
06104103
OW04103
06104104
OW04104
LIAR
$2.000.000
X
BODILY INJURY
(Pa P—)
S
X
tPBODILYN Y
j
X
X
1
_
Solt Insured
C
A
A
GARAGE LIABILITY
ANYAARO
O°C MOM' ►
X occuR CLAIMS MADE
ROEDUCTIBI E
X RETENTION _AO
woRma comes EIATKNN AND
EMPLOYE LIABILITY
ANY PROFAETORf EARTNERfaECUTI�
OF�lMBdBER QICLUDE07
I drsab wider
PROVLStDINS bskw
OTNFJN
UC374484303
TC2JUB466K197003
TRJUB46WI98M
OW04l03
OW04103
061041*03
OW04104
06104104
OW04104
AUTO ONLY - EA ACCIDENT
OTHER THAN EAAOC
AUTO ONLY: AGO
EAaHNOccuT:ReNce
S
i
AGGREGATE
Q00
X A oTN
i
E.LEACHACCEfENIT
$10000,000
E.L DISEASE - EA EbW 0
100 1000
E,L DISEASE - POLICY LIMIT
$1,0N.ON
DESCRIPTION OF OPERATIONS i LOCATIONS I VEHICLES I E MUSKM ADDED BY ENDORSEMENT SPECIAL PROVISIONS
WESCO Dlsf txdloo, Inc. a WESCO International, IM a any organization, other than a
PwbwshlP or Joint venture, over Which WESCO maintains ownership or majofity interest
on the effective date of the policy.
At the time WESCO Is awarded the job for the City of Vernon, the City, its
(See Attached Descriptions)
CERTIMATF W N rWD
City of Vernon (city)
4305 Santa Fe Avenue
Los Angeles, CA 90058
ACORD 25 (2 IMS)1 of 3 OSS7168IM77065
LD ANY OF THE ABOVE DESCRIBED POLICES BE CANCELLED BEFORE THE EXPIRATION
THEREOF, THE ISSUM INSURER WILL ENDEAVOR TO MAIL In DAYS WRITTEN
;E TO THE CERTIFICATE HOLDER NAMED TO THE LEFT. BUY FAILURE TO DO SO SHALL
IE NO OBLIGATION OR LIASILM OF ANY KIPS UPON THE INSURER. ITS AGENTS OR
LFO 0 ACORD
IMPORTANT
If the certificate holder Is an ADDITIONAL INSURED, the poky(ies) must be endorsed. A statement
on this certificate does not confer ruts to the certificate holier In Neu of such endorsement(s).
If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may
require an endorsement, A statement on this MWlcate does not confer rights to the certificate
holder In lieu of such endorsement(s).
DISCLAIMER
The Ce WK*te of Insurance on the reverse side of this form does not constitute a contract between
the issuing insurer(s), authorized representative or producer, and the certificate holder, nor does it
affirmatively or negatively amend, extend or alter the coverage afforded by the policies listed thereon.
ACORD 25S r2 IMI •s ...
SPECIFICATION NO. TR1-20.03
OVERHEAD DISTRIBUTION TRANSFORMERS
CITY OF VERNON
LIGHT AND POWER
November 19, 2003
SPECIFICATION NO. TR1-2003
Approved Manufacturers/Suppliers
I. Cooper Power
c/o Mark Christensen
Utility Products
44-909 Golf Center Pkwy, Suite #12
Indio, CA 92201
Phone: (760) 863-1660
2. ABB Inc.
Attn: Jeff Vivian
2945 Harding Street, Suite 207
Carlsbad, CA 92008
Phone: (760) 720-3156
3. Howard Transformers
c/o Young and Company
530 South Marengo Ave
Pasadena, CA 91101
Phone: (626) 795-9955
4. General Electric Company
c/o Southwest Power
9837 Pioneer Blvd.
Santa Fe Springs, CA 90670
Phone: (562)801-4577
5. Central Moloney
c/o Southcoast Utility Sales
8762 Luss Drive
Huntington Beach, Ca 92646
(Phone): (714) 962-0841
Fax: 714-963-2487
6. Kuhlman Electric Corp.
101 Kuhlman Road
Versailles, KY 40383
(Phone): (800) 395-6932
Fzxv- 52fZQ Q'77 ones
Prepared by:
Approved by
rwililem ueuano, P.E.
Director of Light and Power
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
1.0 SCOPE
Supplier shall furnish all work for providing one -phase, 60 Hz, mineral oil filled,
overhead type distribution transformers rated 500 kVA and below for use on the
City of Vernon's overhead distribution system. The transformer sizes that the
City requires are listed in Attachment A. This list does not preclude the
possibility of ordering voltage and KVA ratings not listed under this specification.
In comparing proposals or bids, consideration will not be confined to lowest
ownership cost only. The successful bidder will be one whose product is judged
to best serve the interests of the City of Vernon when first cost, lowest ownership
cost, product, safety, quality, and delivery are considered. The City of Vernon
reserves the right to reject any or all proposals or bids or any part thereof, and to
waive any minor technicalities from the specifications. A contract will be awarded
to the bidder submitting the lowest responsible bid meeting the requirements of
this specification.
2.0 APPLICABLE STANDARDS
A. The transformers shall conform to the applicable sections of the following
standards to the extent referenced in this Specification, and as amended to
the date of this Specification which, by reference, are included as part of this
Specification.
A. C57.12.00
IEEE Standard General Requirements for Liquid -
Immersed Distribution, Power, and Regulating
Transformers.
B. C57./12.10
Requirements for Transformers 230,000 Volts and
Below, 833/958 through 8,333/10,417 kVA single
phase, and 750/862 through
60,000/80,0o0/100,000 kVA three phase without
Load Tap Changing; and 3750/4687 through
60,00/80,000/100,000 kVA with Load Tap
C. G57.12.20
Changing -Safety Requirements
Overhead -Type Distribution Transformers, 500
kVA and Smaller. High Voltage, 34 500 Volts and
Below; Low Voltage 7970/13800Y Volts and
D. C57.12.90
Below
IEEE Standard Test Code for Liquid -Immersed
Distribution, Power, and Regulating Transformers
and IEEE Guide for Short -Circuit Testing of
Distribution and Power Transformers.
E. C57.91
Guide for Loading Mineral -Oil -Immersed
Overhead and Padmounted Transformers Rated
500 kVA and Less with 650C or 550C Average
3of19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
Winding Rise.
F. (:57.106 IEEE Guide for Acceptance and Maintenance of
Insulating Oil in Equipment.
6, In the event of conflict between the codes and standards and this
Specification, Supplier shall notify City of Vernon Light and Power
Department and secure a written clarification before proceeding with the
work.,
4of19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
3.0 SERVICE CONDITIONS
3. 1. Environment
A. The transformers shall perform in accordance with all provisions of
the Specification while subject to the service conditions specified in y
ANSI/IEEE C57.12.00.
B. The transformer shall be suitable for 30 years of use on the City of
Vernon's electric system when installed in accordance with the
service conditions set forth in the latest edition of the ANSI/IEEE
C57.12.00, Section 4.0, in its entirety.
3. 2. Seismic and Impact Loading
A. Before and during installation, the transformers shall withstand,
without damage, rough handling such as bouncing on a truck when
filled with insulating medium and impacting against or upon rigid
structures at speeds up to five feet per second, and being lifted by
two bosses or lifting second, and being lifted by two bosses or
lifting bolts at any angle. Following these conditions, the
transformers shall be capable to being energized without a pre-
operational test.
B. After installation and during the 30-year life of transformer,
transformer will be subject to occasional earthquake motions (0.2g
horizontal and 0.13g vertical) along with significant vibrations from
traffic and from adjacent equipment.
3.3 Pre -installation Inspection
The City of Vernon will, at its discretion, provide a pre -installation
inspection of each transformer.
3.4 O erating Duty
A. For its 30-year life, each transformer shall be suitable for operation under
short circuit conditions as stated in the latest editions of ANSI/IEEE
C57.12.00 and C5712.90. Supplier shall supply verification that the design
has passed the required short circuit criteria.
5of19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
4.0 RATINGS
4.1 Sizes
The transformers shall be sized as shown in Attachment A.
4.2 High Voltage Ratings
Transformers shall be 60 Hz with BIL ratings and Insulation Class as shown
in the gable below.
Tr.a.a.�.. r..,.�_ ae �a_ a •
"�^..• aaava 111 11 V Vlld G m--pon tonaracteristics
Transformer High Insulation Class (KV) Insulation BIL (KV)
Voltage KV
7.2/12.47Y 15 95
16.34 18 125
4.3 Low Voltage Ratinq
Transformers shall be 60 Hz with BIL ratings and Insulation Class as shown
in the table below.
Tr --- f ...r..._ 1 ai_u _
- - ---
Transformer High
Voltage(Volts)
•• • vain G 111'U1dl1Un l/naracteristics
Insulation Class (KV)
Insulation BIL (KV)
120/240
1.2
30
277
1.2
30
6of19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
4.4. Impedances
Transformer impedance shall not be less than those shown in the table
below. All transformer testing to determine transformer impedance shall be
based on the base kVA rating of the transformers 65 degree Celsuis
temperature rise. The transformer impedances shall be shown on the
transformer nameplate.
Minimum Transformer Impedance
VOLTAGE
240
KVA
10-75
%Z
2.0
240
100-167
2.5
240
250
3.0
277
15-100
2.0
277
167-333
2.5
277
500
3.0
5.0 CONSTRUCTION FEATURES
5.1 Coil and Core Construction
A. The transformer core shall be of high efficiency rectangular wound core. .
The core shall be made from one of two processes: single -turn
laminations of high quality, grain oriented silicon core steel. Amorphous
core (i.e metallic glasses metal) transformers are not acceptable.
B. The transformer coils shall be designed to maintain their nameplate KVA
rating throughout the normal temperature range of operation which shall
be 65*C (80°C hot spot). All materials used shall be of the 65°C, 800C hot
spot class. All materials shall be thoroughly tested for compatibility with all
transformer components before being assembled.
C. The primary coil shall be manufactured from heavy varnish or paper
insulated aluminum or copper wire. The secondary coil shall be
manufactured from full width aluminum strip whose edges are finished to
prevent burrs and insulated with epoxy -diamond paper between layers of
the conductor.
D. All insulating paper used as layer insulation in transformer coil shall be
bonded type, coated on both sides with a thermosetting adhesive and
properly cured prior to impregnating with oil or the coils shall be wound
with primary conductor containing a thermosetting adhesive that when
properly cured will form an effective bond, both turn to turn and layer to
layer.
7of19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
5.2. Insul,ating Fluid
A. The transformer insulating fluid shall be standard electrical grade mineral
insulating oil. The insulating oil shall be tested and degassed to assure a
chemically inert oil. The transformers shall be furnished with oil which
meets the requirements specified in ASTM Standard D 3487 for mineral
insulating oil, except that the DBPC content (% by weight) shall not be
less than 0.15. The insulating oil in the equipment shall conform with
ANSI C57.106.
B. All transformer oil shall be tested for polychlorinated biphenyl's (PCBs) per
ASTM D4059 and certified as having no detectable levels of PCB. All oil
furnished by supplier shall not contain any detectable traces of
Polychlorinated biphenyls.
C. A sealed tank shall be provided on all transformers
5.3 Taps rind Changers
A. The transformers shall be furnished with full capacity high -voltage taps.
The tap changer shall be externally operated and clearly labeled to reflect
that the transformer must be de -energized before operating the tap
changer as required in Section 3.3 of ANSI C57.12.26. Padlocking
provisions shall be available for lever or hotstick operable handles. Tap
changer operating mechanisms shall be permanently identified to show
"De -energized Operation Only". Decals and stencils are not acceptable.
The unit shall have one of the following tap configurations:
Two - 2%z% taps above and below rated voltage such as the following:
VOLTAGE FULL CAPACITY TAPS
16,340 17,200/16,770/15,910/15,480
7,200 7,560/7,380/7,020/6,840
B. The tap changer position indicating nameplate shall have numerals or
letters that are clearly legible and of permanent quality. Decals and
stencils are not acceptable.
8of19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
5.4 Pressure Withstand and Pressure Relief
A. An assembly shall be provided that is designed for pressure relief. The
assembly shall remain effectively sealed for overloads and external
secondary short circuits of the duration and magnitude allowed by industry
standards, but shall relieve pressure at a minimum of 8 PSIG. Design
should meet the requirement of the latest edition of the ANSI C57.12.20
paragraph 6.27 for relief of excessive pressure.
B. The valve shall be of the indicating type with weatherproof cover, and
equipped with a pull -ring for hook -stick operation. It shall have 1/4 inch
NPT threads and be located on the tank wall above the oil level in either
segment 2 or 4 as designed in ANSI C57.12.20, Table S2. The valve shall
meet the following minimum operating characteristics:
1. Cracking Pressure: 10 PSIG
2. Re -seal: 5 PSIG
3. Flow Rates: 50 SCFM at 15 PSIG
100 SCFM at 50 PSIG
C. The valve body and various parts of the device shall be corrosion resistant.
Only the following pressure relief devices are acceptable:
1. Circle Seal Model No. P60-383
2. Qualitrol Model No. 202-032-01 or 202-33-01
3. Beta Model Nos. 1712K-1, -5, -6, or Model No 1750K-5.
D. The required electrical clearances between pressure relief valve and live
parts shall be maintained.
5.5 Tank Pressure Withstand
A. Tank withstand should meet the latest edition of NEMA TR1, Part 2.
B. Tank (bottom shall have a rolled edge and tank wall base which is three
layers thick.
5.6 Tank Finish
A. Tank covers shall have a slope of 15 degrees for moisture run-off and
100 kVA and below, shall have an insulated coating on the cover
capable of withstanding 15kV at a 2000 volt/sec rate of rise, or equal,
tested per ASTM D149 using 1/4" diameter electrodes, or equal. The
results of design test to confirm this capability shall be submitted for
approval.
9 of 19
CITY OF VERNON LIG14T AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
B. The tank coat will be a finish which can withstand a direct blow of 160
inch -pounds per ASTM D-2794-69 for units 100 kVA and below and
meets or exceeds the following as set forth in ANSI C57.12.28:
1. Salt spray for 1000 hours
2. Humidity Test,
3. Abrasion resistance
4. Crosshatch adhesion
5.Oil resistance.
C. The paint on all transformer tanks shall be grayish in color and conform
to Munsell 5BG 7.0/04 with the following tolerances:
1. Hue:
+/-12 (3G and 713)
2. Value:
+/-0.2
3. Chroms:
+/-0.2
5.7 Tank and Covers
A. Transformers shall have bolted covers for all size transformers. One
spare bolt per each transformer shall be provided and included in the bid.
5.7 Internal Lead Identification
A. Internal secondary leads shall be identified with appropriate markings
permanently embossed in the lead that correspond with lead markings on
the nameplate.
5.8 Extemal Features
A. Transformers shall be provided with cover mounted high voltage
porcelain bushings with eyebolt terminals, low voltage porcelain bushings
with eyebolt terminals and ANSI single position support lugs (hanger
brackets) with nameplate on lower bracket. For all transformers rated
above 167 kVA, no support brackets are required.
5.9 Weight and Dimensions
A. The maximum weight for transformers 100 kVA and below shall be
1,400 lbs.
B. All 250, 333, and 500 kVA single phase transformers shall be 'light
weight' transformers. The weights and dimensions of the "lightweight"
transformers shall not exceed the weights and dimensions specified
below.
10 of 19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
Rating (kVA)
Weight (Ibs)
Height
Inches
Widtfi
Inches
Depth
Inches
250
2,500
72
41
38
333
2,800
72
41
38
500
3,300
72
50
42
5.11 Ground Provisions
A. All transformers shall have a tank grounding provision.
5.12 High Voltage Bushings
A. Transformer rated 15 kVA through 167 kVA shall be furnished with two
cover -mounted bushings. High Voltage bushing terminals shall be in
accordance with the latest edition of the ANSI Standard C57.12.20,
paragraph 6.1.2.2.
B. The cover -mounted bushings shall be of the 15kV insulation class for
7kV transformers and 17kV insulation class for 16kV transformers. The
creepage distance of the bushings shall not be less than 15 inches.
C. When the distance between live parts of cover -mounted bushings is
less than 12 inches, the bushings shall be equipped with approved bird
guards. Bird guards that are approved for use on overhead transformers
are:
MANUFACTURER MODEL NUMBER
C:oltec Industries 703803-53
Porcelain Products 65001 throw h 65019
_ RTE 0704119b01
Kuhlman Electric 6210209902 assembly
6210208804 assemblv
t t of t9
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
5.13 Internal High -Voltage Connections
A. Each internal high -voltage lead shall be equipped with either a ring -
tongue or a hook -type connector. Each connector shall be terminated on
a fixed threaded stud, a fixed threaded bolt, or a non -removable threaded
bolt, each having two nuts for holding and locking purposes.
1. Ring -tongued type: The ring -tongue terminals shall have
mechanical and electrical properties so as to contain the high -
voltage leads, without breaking, even under short-circuit conditions.
Bumdy type YAV are typical of the type desired.
2. Hook type: Hook terminals shall meet the same physical
requirements as specified above for ring -tongue terminals. In
addition to the above, both changing and locking nuts shall be held
captive to prevent their complete removal. AMP, Inc. Style No. 3
"Hook" terminals are typical of the type desired.
5.14 Name fates
A. A stainless steel nameplate shall be attached with non -corrosive
hardware to the inside of the low voltage compartment door. The
nameplate shall not be installed on the rear of the low voltage
compartment area. Diagrams and numbers shall be of the size and
quality such that they can be read from outside the compartment. In
addition to the nameplate requirements shown in ANSI/IEE C57.12.00-
1987, for nameplate A with total weight including oil shall be indicated.
5.15 MSDS
A. The supplier shall be required to provide all applicable Material Safety
Data Sheets with all transformer orders.
6.0 TESTS
6.1 General
A. Transformer tests shall be performed as specified in ANSI Standard
C57.12.00. These test reports shall be provided to the City prior to
shipping. The City will not receive any transformers without the
required test reports.
B. Units shall comply with routine test requirements of ANSI and certified
test reports shall be furnished. The vendor shall provide with returned
bids all applicable documentation of compliance with ANSI design
12 of 19
CITY OF VERNON LIGkT AND POWER '
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
tests.
C. The following data shall be submitted with each transformer order.
a. Guaranteed maximum no load (excitation) loss at rated voltage and
110% voltage in Watts. p
b. Guaranteed maximum load loss in Watts at rated voltage and
110% voltage.
c. Guaranteed maximum total loss in Watts at rated voltage and
'I 10% voltage.
d. Exciting Current in percent at rated voltage and 110% rated
voltage.
e. Percent impedance on base voltage and at the maximum
temperature rise.
f. Efficiencies shall be provided at loading levels of 100%, 75%,
50%, and 25%.
g. Regulation at rated load @ 80% and 100% Power Factor.
h�. Two sets of outline drawings showing dimensions, weight, gallons
of oil, gauge of steel in tank walls, cover, bottom, and cooling
radiators and description of accessories. After order is awarded,
the vendor shall submit FINAL drawings.
i. Verification that the transformer design has passed the required
short circuit criteria per Section 3.4 of these specifications.
7.0 OPERATING PERFORMANCE
7.1 General
The Apparatus shall perform in accordance with the conditions set forth in
this Specification.
13 of 19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
8.0 BID EVALUATION
8.1 Total Ownership Cost
The purchase price of transformers shall be evaluated by lowest total
ownership cost. The formula to evaluate Total Owning Cost (TOC):
TOC = C + $4.53/W (PNL in Watts) + $1.11W (PLL in Watts)
Where TOC is the total ownership cost in dollars, C is the initial cost in
dollars, PNL is the guaranteed maximum no-load loss in watts, and Pu is
the guaranteed maximum load loss in watts
For the determination of the award for the transformer order(s), City will
consider all bids within 5% of the lowest Present Value Cost of
Transformer to be economically equivalent. The City of Vernon realizes it
is impossible to accurately predict economic conditions over the
evaluation period of 30 year s. Reference Section 1, SCOPE, second
paragraph of these specifications.
8.2 Deliver
A delivery date of 16 weeks ARO or less is required. Failure to quote a
delivery schedule within this period may disqualify the bid.
9.0 DOCUMENTATION
9.1 For Bid Evaluation
Bidders shall fumish the following in their bid proposals:
1. Transformer unit price, F.O. B. Soto Yard.
2. Guaranteed maximum no-load loss at rated voltage in watts.
3. Guaranteed maximum load loss in watts at rated voltage and kVA.
4. Percent impedance on rated voltage tap.
5. Two sets of dimension and outline drawings.
14 of 19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
9.2 For Delivery
Supplier shall furnish MSDS and certified test reports and drawings, as
listed in Section 11.1 in this Specification one month before transformers
are shipped. -
These documents shall be submitted to:
City of Vernon
Utilities Department
4305 Santa Fe Avenue
Vernon Ca, 90058
Phone: (323) 583-8811
Attention: Jose Lugo
Electrical Engineer
10. CONTRACT
A. The vendor may be required to execute a purchase contract with City of
Vernon, and may be required to furnish proof of insurance pursuant'to
Attachment B, Insurance Schedule. If required, the vendor shall provide a letter
from its insurance company that certifies the amounts of the insurance policy.
The letter from the insurance company will be in substantially the same form as
the SAMPLE INSURANCE FORM LETTER, which is also included in Attachment
B.
11. SHIPMENT
A. Supplier's quote shall be F.O.B. City of Vernon, Soto Yard located at 2800
Soto ,Avenue, Vernon Ca 90058.
B. Transformers will be delivered on a flatbed track for side unloading by
forklift at ground level.
C. Supplier shall notify City 48 hours prior to delivery. All delivery shall be
Monday -Friday, 7:30 AM to 3:00 PM. Contact telephone is (323) 589-
9498 or (323) 585-5192.
D. 15 days prior to shipment, supplier shall furnish certified test reports of the
switch.
E. 15 days prior to shipment, supplier shall fumish three (3) sets of
Operations/Instruction Manuals.
15 of 19
CITY OF VERNON LIGHT1AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
12. WARRANTY
Supplier shall provide warranty for a minimum of twelve (12) months after
delivery.
16 of 19
CITY OF VERNON LIGI4T AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
ATTACHMENT A Transformer Rmt;.,r.� 11�^A t-, +t,,, .,
ITEM
QUANTITY
RATED
VOLTS
(PRIMARY
VOLTS
RATED
VOLTS
(SECONDARY
VOLTS
RATING
(KVA)
MATERIAL
CODE
1
2
3
4
5
6
7
0
3
5
0
6
0
0
7200/12470Y
7200112470Y
7200/12470Y
7200112470Y
7200/12470Y
7200/12470Y
7200112470Y
120/240
1201240
120/240
120/240
120/240
120/240
120/240
15
25
37.5
50
75
100
167
001-0151
001-0251
001-0371
001-0501
001-0751
001-1001
001-1671
8
9
10
11
12
13
14
15
16
17
0
8
0
0
0
0
0
0
0
0
7200/12470Y
7200/12470Y
7200/12470Y
7200/12470Y
7200/12470Y
7200/12470Y
7200/12470Y
7200112470Y
7200/12470Y
7200/12470Y
2771480Y
277/480Y
777/480Y
277/480Y
277/480Y
277/480Y
277/480Y
277/480Y,
277/480Y
277/480Y
15
25
37.5
50
75
100
167
250
333
500
001-0152
001-0252
001-0372
001-0502
001-0752
001-1002
001-1672
001-2502
001-3332
001-5002
8
19
20
21
22
23
24
0
12
0
15
0
0
0
16340
16340
16340
16340
16340
16340
16340
120/240
120/240
120/240
120/240
120/240
120/240
120/240
15
25
37.5
50
75
100
167
002-0151
002-0251
002-0371
002-0501
002-0751
002-1001
002-1671
25
26
27
28
29
30
31
32
33
34
35
6
7
0
12
0
0
11
0
0
0
0
16340
16340
16340
16340
16340
16340
16340
16340
16340
16340
16340
2771480Y
277/480Y
2771480Y
277/480Y
2771480Y
277/480Y
277/480Y
2771480Y
2771480Y
277/480Y
2771480Y
10
15
25
37.5
50
75
100
167
250
333
500
002-0102
002-0152
002-0252
002-0372
002-0502
002-0752
002-1002
002-1672
002-2502
002-3332
002-5002
17 of 19
CITY OF VERNON LIGHfi AND'POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
ATTACHMENT B
INSURANCE SCHEDULE (Vendor)
The Contractor shall provide proof of insurance, including a standard certificate of
insurance, in at least the following amounts and coverage (combined single limit
permitted):
Coverage
and Limits
Bodily ury
Property
Damage
Hazards
Each Person
Each Accident
Each Accident
Automobile Liability
Owned Automobiles
$500,000
$1,000,000
$500,000
Hired Automobiles
$500,000
$1,000,000
$500,000
Non -Owned Automobiles
$500,000
$1,000,000
$500,000
Workers' Compensation
$ Statutory
Employers' Liability
$1,000,000
per em to er
II. General Liability
Premises Operations
$1,000,000
$2,000,000
$1,000,000
Elevators (if applicable)
$1,000,000
$2,000,000
$1,000,000
Independent Contractors
$1,000,000
$2,000,000
$1,000,000
Products — Completed
$1,000,000
$2,000,000
$1,000,000
Operations
Contract Liability$1,000,000
$2,000,000
$1,000,000
Umbrella Liabilit
$4,000,000
$1,000,000
$1,000,000
The general liability policy shall contain the following special endorsements which shall
be noted on or attached to the standard certificate of insurance:
An endorsement naming City, its officers, and employees as insureds under the policy.
An endorsement providing City thirty (30) days notice of cancellation or material
reduction of coverage.
An endorsement providing coverage for all operations under City permit and specifying
the activities covered.
Such other endorsement as may be required by addendum hereto.
In addition to the standard certificate of insurance, proof of general and umbrella liability
coverage shall be furnished in the form checked below. Certification of the following
proofs by the insurance agent or broker will not be accepted:
For each policy, a notarized letter from the underwriter or carrier certifying that the
coverage and statements in the standard certificate of insurance (attached thereto) are true
and correct and that the signator is an officer authorized to so certify.
A copy of each policy certified by an officer of the underwriter or carrier and notarized.
18 of 19
SUPPORTING
DOCUMENTS
�1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16,
17111
18'I
19
20''
21
221',
23
24
25
26
27
28
EQUIPMENT PURCHASE CONTRACT
THIS AGREEMENT is made, entered into and executed in
duplicate originals, either copy of which may be considered and used
as the original hereof for all purposes, as of this day of
February, 2004, in the City of Vernon, County of Los Angeles,
California
BY AND BETWEEN
AND
RECITALS
THE CITY OF VERNON
(hereinafter referred to as
the "City")
4305 Santa Fe Avenue
Vernon, CA 90058
WESCO DISTRIBUTION, INC.
(hereinafter referred to as
"WESCO")
10020 Freeman Avenue
Santa Fe Springs, CA 90670
WHEREAS, on December 11, 2003, the City requested proposals
or bids for 115 various one -phase, 60 Hz, mineral oil filled, overhead
type distribution transformers (the "Transformers") (Bid No. 1432)
needed by the City's Light and Power Department; and
WHEREAS, the City is permitted to accept or reject any or
all quotations received on the bid items; and
WHEREAS, on or about January 8, 2004, the City received
various proposals for the sale of the Transformers identified in Bid
No. 1432, with each of the 115 bid items quoted separately; and
WHEREAS, on January 5, 2004, WESCO, submitted a bid; and
WHEREAS, on January 8, 2004, the City opened the bid
submitted by WESCO, as well as other bids for the items identified in
Bid No. 1432; and
WHEREAS, the City desires to purchase the following bid
E
1 items from WESCO: three (3) 25 KVA, 7.2 KV 120/240V Transformers; five
2 (5) 37.5 KVA, 7.2 KV 120/240V Transformers; six (6) 50 KVA, 7.2 KV
3 120/240 V Transformers; six (6) 75 KVA, 7.2 KV 120/240V Transformers;
4 eight (8) 25 KVA, 7.2 KV 277/480 Transformers; six (6) 50 KVA, 7.2 KV
5 277/480 Transformers; and three (3) 250 KVA, 7.2 KV 277/480
6 Transformers for a total of thirty-seven (37) Transformers per City of
7 Vernon Specification No. TR1-2003.
8 NOW, THEREFORE, THE PARTIES HERETO DO MUTUALLY AGREE AS SET
9 FORTH HEREIN:
10 1. Purchase. WESCO agrees to sell and deliver to the
11 City a total of thirty-seven (37) Transformers referenced above
12 pursuant to City of Vernon Specification No. TR1-2003, as identified
13 in WESCO's January 5, 2004 bid and which meet the specifications
14 contained in City of Vernon Bid No. 1432, dated December 11, 2003
15 (collectively referred to as the "Bid Documents"). A copy of the Bid
16 Documents are attached hereto as Exhibit "A" and incorporated herein
17 by reference.
18 2. Time of Performance. WESCO's performance shall
19 commence upon the full execution of this Contract and delivery of the
20 transformers and shall be completed by WESCO within 16 weeks after
21 receipt of order.
22 3. Price. The City agrees to purchase thirty-seven (37)
23 Transformers from WESCO for the total sum of Thirty -One Thousand Seven
24 Hundred Forty -Six Dollars and No Cents ($31,746.00). This price
25 includes freight and excludes sales tax.
26 4. Delivery. Consistent with the Bid Documents, WESCO
27 agrees to deliver the thirty-seven (37) Transformers on a flatbed
28 truck for side unloading by forklift at ground level to the City.
-2-
r1 WESCO shall notify the City 48-hours prior to delivery at (323) 589-
y
2 9498 to make arrangements for gates to be opened. Delivery shall be
3 scheduled for Monday through Friday between the hours of 7:30 a.m. and
4 3 p.m. Prior to shipment, WESCO shall furnish certified test results
5 of the switch and three (3) seas of Operations/Instruction Manuals.
6 5. Warranties. WESCO warrants title to the Transformers
7 purchased hereunder and any part thereof to be free of any claim or
8 any security interest, lien or encumbrance. WESCO also warrants that
9 the Transformers will be delivered new and shall be free from defects.
10 WESCO shall provide, at a minimum, a one (1) year labor and material
11 warranty to begin upon acceptance of the Transformers by the City.
12 All manufacturers'' warranties, any warranties typically provided by
13 WESCO and any other warranties made applicable by law shall apply to
14 the City's purchase of the Transformers.
15 6. Governing Law. The validity, interpretation and
16 Performance of this Contract shall be controlled and construed under
17 the laws of the State of California.
18 7. Forum Selection. Any action brought relating to this
19 Contract shall be brought and held exclusively in a State Court in the
20 County of Los Angeles, California.
21 8. Notices. Notices to the parties, unless otherwise
22 requested in writing, shall be sent to:
23 City: THE CITY OF VERNON
ATTN: DOLORES FONSECA
24 PURCHASING ASSISTANT
4305 SANTA FE AVENUE
25 VERNON, CA 90058-0805
26 WESCO: WESCO DISTRIBUTION, INC.
ATTN: LESLIE MCCOY
27 BRANCH OPERATIONS MANAGER
10020 FREEMAN AVENUE
28 SANTA FE SPRINGS, CA 90670
-3-
Y
1 9. Risk of Loss. Title and risk of loss or damage shall
2 pass to the City and delivery shall be deemed to be complete upon
3 delivery FOB jobsite or upon moving into storage at the City's
4 request, whichever occurs first.
5 10. Attorneys' Fees. In the event that it becomes
6 necessary for either party to this Agreement to enforce any of the
7 provisions of this Agreement, the parties agree that a court of
8 competent jurisdiction may determine and fix reasonable attorney's
9 fees to be paid to the successful litigant.
10 IN WITNESS WHEREOF, the parties have caused this Agreement
11 to be executed by and through their authorized officers on the date,
12 month and year first written above.
13 CITY OF VERNON
14
15 By.
EONIS C. MALBU �,Mayr
16 ATTEST:
17 GX j
18 BRUCE V. MALKENHORST, City Clerk
19 APPROVED AS TO FORM:
20
21 ERIC T. FRESCH, City Attorney
22 WESCO DISTRIBUTION, INC.
23 By:
24 Title: frc A ;n1�a,Cr-
25
26 BY: i
27 Title: S-ArS 1, r-c"Tor
28
-4-
REQUEST FOR QUOTATIONS
NOT A PURCHASE ORDER
D16ECTALL INQUIRIES TO:
CITY PURCHASING AGENT
TELEPHONE (323) 583-8811
CITY OF VERNON, CALIFORNIA
PURCHASING DEPARTMENT
CITY HALL .
4305 Santa Fe Ave. - Vernon, California 90058
ABB
TO: Mr. Greg Tagliaferri
c/o Wesco Distribution, Inc.,
10020 Freeman Avenue
Santa -Fe Springs, CA 90670
FOR CITY USE ONLY
QUOTATION NO. 1432
DATE MAILED 12 03
REC'D BY CITY-bl ®O r
Please quote hereon the lowest net price you can furnish the articles or services specified below. Quote on each item separately. Bidder may
qualify quotations as "all or none" by stating so on body of form. City reserves the right to accept or reject quotations received on any or all
items. In order to maintain their name on City's Bidder File, Vendor should return this form whether a price is quoted or not.
QUANTITY
DESCRIPTION
NET UNIT PRICE
TOTAL
Overhead type distribution transformers, as per
City of Vernon Light & Power Specification No. TR1-2003
dated November 19, 2003.
t-3
25 KVA, 7.2 KV 120/240V73
Overhead Transformer
1-5
37.5 KVA, 7.2 KV,
120/240 V Overhead Transformer
�V
4��W6
50 KVA, 7.2 KV,
120/240 V Overhead Transformer
7�%
00
�% �2'
6
75 KVA, 7.2 KV,
120/240 V Overhead Transformer
. -- 8
25 KVA, 7.2 KV,
277/480 Y Overhead Transformer
/-700
00
4 7oltO
�
ra-6
50 KVA, 7.2 KV,
277/480 Y Overhead Transformer
-7357
a°
4ygff
-3
250 KVA, 7.2 KV,
277/480 Y Overhead Transformer
�c
-7'77
-----------PLEASE NOTE ---- ----
Bid number must be indicated on the outside
of the envelope; otherwise, bid will not be
accepted.
IF INSUFFICIENT SPACE PROVIDED ABOVE FOR PROPOSAL, ATTACH RIDER OR SUPPLEMENT. CASH DISCOUNTS
QUOTED FOR PERIODS OF LESS THAN 30 DAYS WILL NOT BE CONSIDERED WHEN ORDER IS AWARDED. BIDS
RECEIVED IN RESPONSE TO THIS REQUEST FOR QUOTATION WILL BE OPENER CITY PURTA]�1 AGENTS
G
8th January : �
OFFICE ON THE DAYoF 20 AT V
NOTE: Quote prices exclusive of Sales Tax and Excise T�fe .
A. Indicate Sales Tax in this space $.....S?,.. 71..`...(.�.i......................................B. Indicate Excise Tax in this space $ .....................................................
B. Above quotations subject to Cash Discount qf...... ti. r �^ ..,.... . %, FO.B... �e'.1AV.�:�GJ...
L{ ! ... ....i i +l�we:�e ilPXilo ................................................
C. To be delivered to CITY OF VERNON at....... r........................................... .......... .............................................................
r............
We (1) agree to furnish above in .........................................days from receipt of purchase order at prices specified `
FOR.............................. ., ....4�%P ...................................
TFi Name j
DATE ........... Y ............................ SIGN HERE ........ ' .-...`.J. .............!—c:x.4............. 4.G.I.........
MAIL TO PURCHASING DEPT. 12/02
REQUEST FOR QUOTATIONS
NOT A PURCHASE ORDER
DIRECTALL INOUIRIESTO:
CITY PURCHASING AGENT
TELEPHONE (323) 583-8811
TO:
CITY OF VERNON, CALIFORNIA
PURCHASING DEPARTMENT
CITY HALL
4305 Santa Fe Ave. - Vernon, California 90058
FOR CITY USE ONLY
QUOTATION NO.
DATE MAILED
REC'D BY CITY
OPENED
BY
Please quote hereon the lowest net price you can furnish the articles or services specified below. Quote on each item separately. Bidder may
qualify quotations as "all or none" by stating so on body of form. City reserves the right to accept or reject quotations received on any or all
items. In order to maintain their name on City's Bidder File, Vendor should return this form whether a price is quoted or not.
QUANTITY
DESCRIPTION
NET UNIT PRICE
TOTAL
f 12
25 KVA 16.34 KV
1(JLJ
CID
120/240 V Overhead Transformer
21
50 KVA, 16.34 V,
120/240 V Overhead Transformer
" 3
167 KVA, 16.34 V,
�a
�p&
120/240 V Overhead Transformer
6
10 KVA, 16.34 KV,�
277/480 Y Overhead Transformer
4333
co7
15 KVA, 16.34 KV,
I'p(q
�
277/480 Y Overhead Transformer
12
37.5 KVA, 16.34 KV,
on
� 2 8�
277/480 Y Overhead Transformer
6
50 KVA, 16.34 KV
�?
277/480 Y Overhead Transformer
11
100 KVA, 16.34 KV,
l-� 7
/(o
277/480 Y Overhead Transformer
----PLEASE NOTE ----------
Bid number must be indicated on the outside
of the envelope; otherwise, bid will not be
accepted.
IF INSUFFICIENT SPACE PROVIDED ABOVE FOR PROPOSAL, ATTACH RIDER OR SUPPLEMENT. CASH DISCOUNTS
QUOTED FOR PERIODS OF LESS THAN 30 DAYS WILL NOT BE CONSIDERED WHEN ORDER IS AWARDED. BIDS
RECEIVED IN RESPONSE TO THIS REQUEST FOR QUOTATION WILL BE OPENED IN CITY PURCHASING AGENTS
OFFICE ON THE DAY OF 20 AT
NOTE: Quote prices exclusive of Sales Tax and Excise Taxes.
A. Indicate Sales Tax in this space $....................................................................B. Indicate Excise Tax in this space $ .....................................................
B. Above quotations subject to Cash Discount of .................................................%, F.O.B .................................................................................................
C. To be delivered to CITY OF VERNON at.........................................................................................................................................................................
we (1) agree to fumish above in .........................................days from receipt of purchase order at, specified.
FOR ................ S �? �D.-........................................
...........
Firma Name
DATE............ SIGN HERE....................................................�cy
.....................................................
.�D. i {
LCs , re� ,ins ,vo2
MAIL TO PURCHASING DEPT. 9 r a� c �, o P J
REQUEST FOR AUOTATIONS
NOT A PURCHASE ORDER
DIRECT ALL INQUIRIES TO:
CITY PURCHASING AGENT
TELEPHONE (323) 583-Ul l
ro:
CITY OF VERNON, CALIFORNIA
PURCHASING DEPARTMENT
CITY HALL
4305 Santa Fe Ave. - Vernon, California 90058
FOR crrY USE ONLY
QUOTATION NO.
DATE MAILED
REC'D BY CITY
OPENED
BY
Please quote hereon the lowest net price you can furnish the articles or services specified below. Quote on each item separately. Bidder may
qualify quotations as "all or none" by stating so on body of form. City reserves the right to accept or reject quotations received on any or all
items. In order to maintain their name on City's Bidder File, Vendor should return this form whether a price is quoted or not.
QUANTITY
DESCRIPTION
NET UNIT PRICE
TOTAL
If you have any questions regarding the bid or the
attached specifications, please call Jose Lugo (Electrical
Engineer) at (323) 583-8811, ext. 276.
------------PLEASE NOTE ----------
Bid number must be indicated on the outside
of the envelope; otherwise, bid Will not be
accepted.
IF INSUFFICIENT SPACE PROVIDED ABOVE FOR PROPOSAL, ATTACH RIDER OR SUPPLEMENT. CASH DISCOUNTS
QUOTED FOR PERIODS OF LESS THAN 30 DAYS WILL NOT BE CONSIDERED WHEN ORDER IS AWARDED. BIDS
RECEIVED IN RESPONSE TO THIS REQUEST FOR QUOTATION WILL BE OPENED IN CITY PURCHASING AGENTS
OFFICE ON THE DAY OF 20 AT
VOTE: Quote prices exclusive of Sales Tax and Excise Taxes.
A. Indicate Sales Tax in this space$....................................................................B. Indicate Excise Tax in this space $ .....................................................
B. Above quotations subject to Cash Discount of .................................................%, F.O.B .................................................................................................
C. To be delivered to CITY OF VERNON at.........................................................................................................................................................................
We (1) agree to furnish above in .........................................days from receipt of purchase order at pric T.
s flied.
FOR ..................... CSCi4?... 45TCt .tio^.... . C�.:......................I..............
Firm Name `
)ATE.........` ..`... .............................. SIGN HERE ..... ............. .y......... si.t �.s.....f fi. ................
MAIL TO PURCHASING DEFT. 10 r, Or ° � ��nr (� y
12-23-2003
i To: LISA GROVES WESCO SANTA FE SPRINGS
` LISA RE YOUR REQUEST FOR BELOW CUSTOMER DTD 12/12 ATHENS QUOTES AS FOLLOWS,
PRICES FIRM IN TRUCKLOAD RELEASES THRU 12/31/04.
REF ATHENS NEG NO: SF121631 City of Vernon
Contract Effective Date: 12/23/2003
Contract Expiration Date: 12/31 /2004
PLS QUOTE:
Shipment Period: 0 1/0 1/2001-06/30/2001
ITEM QTY PRODUCT
ID
1 3 A7312W25ZZM1631
CustProduct-ID: 001-0251
Overhead Distribution Transformer; S - Conventional
25 KVA
No Load: 50 Watts at 85 degrees C; Load: 362 Watts at 85 degrees C; Total Loss: 412 Watts
7200/12470Y HV; 95 BIL; Copper HV Winding Matl
With Taps at 7560, 7380, 7020, 6840
120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mall
60 Hz
1 Phase
Transformer Weight: 352.13 lbs.; Height: 39 in.; Width: 20.00 in.; Depth: 24.00 in.
Est. Shipping Dimensions: 366.13 lbs. Height: 43 in.; Width: 24 in.; Length: 25 in.;
Est. C/C Weight: 191.8 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt
3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain
13.3 Gal(s) of Transformer Oil
1 15.25" Carbon STL Cover, 2 HV Bushing Holes
2 5 A7312W37ZZM1631
CustProduct-ID: 001-03 71
Overhead Distribution Transformer; S - Conventional
37.5 KVA
No Load: 85 Watts at 85 degrees C; Load: 420 Watts at 85 degrees C; Total Loss: 505 Watts
7200/12470Y HV; 95 BIL; Copper HV Winding Matl
With Taps at 7560, 7380, 7020, 6840
120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl
60 Hz
ha
1 Phase
Transformer Weight: 466.99 lbs.; Height: 39 in.; Width: 22.00 in.; Depth: 27.00 in.
Est. Shipping Dimensions: 487.99 lbs. Height: 43 in.; Width: 26 in.; Length: 26 in.;
Est. C/C Weight: 262.35 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt
3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain
17.4 Gal(s) of Transformer Oil
1 17.5" Carbon STL Cover, 2 HV Bushing Holes
ti
3 6 A7312W50Z2M1631
CustProduct-ID: 001-0501
Overhead Distribution Transformer; S - Conventional
50 KVA
No Load: 86 Watts at 85 degrees C; Load: 605 Watts at 85 degrees C; Total Loss: 691 Watts
7200/12470Y HV; 9YBIL; Copper HV Winding Mad
With Taps at 7560, 7380, 7020, 6840
120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl
60 Hz
1 Phase ,✓
Transformer Weight: 592.851bs.; Height: 48 in.; Width: 22.00 in.; Depth: 27.00 in.
Est. Shipping Dimensions: 613.85 lbs. Height: 52 in.; Width: 26 in.; Length: 26 in.;
Est. C/C Weight: 306.44 lbs.
65 Temp. Rise;
I HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt
3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain
25.8 Gal(s) of Transformer Oil
1 17.5" Carbon STL Cover, 2 HV Bushing Holes
4 6 - A7312W75ZZM1631
CustProduct-ID: 001-0751
Overhead Distribution Transformer; S - Conventional
75 KVA
No Load: 144 Watts W degrees C; Load: 778 Watts at 85 degrees C; Total Loss: 922 Watts
7200/12470Y HV; 95 BIL; Copper HV Winding Matl
With Taps at 7560, 7380, 7020, 6840
120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl
60 Hz
1 Phase
Transformer Weight: 840.98 lbs.; Height: 52 in.; Width: 25.00 in.; Depth: 31.00 in.
Est. Shipping Dimensions: 872.98 lbs. Height: 56 in.; Width: 32 in.; Length: 33 in.;
Est. C/C Weight: 412.261bs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt
3 LV Bushings, Eye Bolt for #I-500MCK Porcelain
39 Gal(s) of Transformer Oil
1 20" Carbon STL Cover, 2 HV Bushing Holes
8 A7352W25ZZM1631
CustProduct-ID: 001-0252
Overhead Distribution Transformer; S - Conventional
25 KVA
No Load: 51 Watts at.Z degrees C; Load: 341 Watts at 85 degrees C; Total Loss: 392 Watts
7200/12470Y HV; 95 BIL; Aluminum HV Winding Mad
With Taps at 7560, 7380, 7020, 6840
277/480Y LV; 30 BIL.; Non-LV Interlaced; Aluminum LV Winding Matl
60 Ih
1 Phase
Transformer Weight: 401.791bs.; Height: 39 in.; Width: 22.00 in.; Depth: 26.00 in.
Est. Shipping Dimensions: 422.79 lbs. Height: 43 in.; Width: 26 in.; Length: 26 in.;
Est. C/C Weight: 198.42 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt
2 LV Bushings, Eye Bolt for #6-4/0, Porcelain
17.9 Gal(s) of Transformer Oil
1 17.5" Carbon STL Cover, 2 HV Bushing Holes
6 6 A7352W50ZZM1631
CustProduct-ID: 001-0502
Overhead Distribution Transformer; S - Conventional
50 KVA
No Load: 88 Watts a85 degrees C; Load: 557 Watts at 85 degrees C; Total Loss: 645 Watts
7200/12470Y HV; 95 BIL; Copper HV Winding Mad
With Taps at 7560, 7380, 7020, 6840
277/480Y LV; 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mad
60 Hz
1 Phase
Transformer Weight: 561.96 lbs.; Height: 44 in.; Width: 22.00 in.; Depth: 26.00 in.
Est. Shipping Dimensions: 582.96 lbs. Height: 48 in.; Width: 26 in.; Length: 26 in.;
Est. C/C Weight: 315.26 lbs.
65 Temp. Rise;.
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt
2 LV Bushings, Eye Bolt for #2-350MCM, Porcelain
21.4 Gal(s) of Transformer Oil
1 17.5" Carbon STL Cover, 2 HV Bushing Holes
7 3 A7352W52ZZM1631
CustProduct-ID: 001-2502
Overhead Distribution Transformer; S - Conventional
250 KVA
No Load: 299 Wattkat 85 degrees C; Load: 1998 Watts at 85 degrees C; Total Loss: 2297 Watts
7200/12470Y HV; 95 BIL
With Taps at 7560, 7380, 7020, 6840
277/480Y LV; 30 BIL; Non-LV Interlaced
60 Hz
1 Phase f
Transformer Weight: 1744.77 lbs.; Height: 57 in.; Width: 39.00 in.; Depth: 33.00 in.
Est. Shipping Dimensions: 1817.77 lbs. Height: 61 in.; Width: 30 in.; Length: 30 in.;
Est. C/C Weight: 919.3 lbs.
65 Temp. Rise;
I HV Tap Chgr, ABB, Ext (lever) setscrew lockable handle, 5 Po
1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt.
2 LV Bushings, 4 Hole "H" spade, Porcelain V STUD
65 Gal(s) of Transformer Oil
1 24" Carbon STL Cover, 2 HV Bushing Holes
12 A1612W25ZZM1631
CustProduet-ID: 002-0251
Overhead Distribution Transformer; S - Conventional
25 KVA
No Load: 57 Watts at 85 degrees C; Load: 323 Watts at 85 degrees C; Total Loss: 380 Watts
16340 95 L; Aluminum HV Winding Mat]
With Taps 200, 16770, 15910, 15480
120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl
60 Hz
1 Phase
Transformer Weight: 404.9 lbs.; Height: 38 in.; Width: 22.00 in.; Depth: 27.00 in.
Est. Shipping Dimensions: 425.9 lbs. Height: 42 in.; Width: 26 in.; Length: 26 in.;
Est. C/C Weight: 202.83 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain
17.6 Gal(s) of Transformer Oil
1 17.5" Carbon STL Cover, 2 HV Bushing, oless
9 21 A1612WSOZZM1631
CustProduct-ID: 002-050
Overhead Distribute ransformer; S - Conventional
50 KVA
No Load: �W at 85 degrees C; Load: 620 Watts at 85 degrees C; Total Loss: 706 Watts
16340 HV, 95 B ; Copper HV Winding Matl
With Taps 17 , 16770, 15910, 15480
120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl
60 Hz
1 Phase Transformer Weight: 59N lbs.; Height: 48 in.; Width: 22.00 in.; Depth: 27.00 in.
Est. Shipping Dimensions: 614.6 lbs. Height: 52 in.; Width: 26 in.; Length: 26 in.;
Est. C/C Weight: 308.65 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain
25.6 Gal(s) of Transformer Oil
1 17.5" Carbon STL Cover, 2 HV Bushing Holes
10 3 A1612W67ZZM1631
CustProduct-ID:002-1671
Overhead Distribution Transformer; S - Conventional
167 KVA
No Load: 2 Wittts at 85 degrees C; Load: 1616 Watts at 85 degrees C; Total Loss: 1841 Watts
16340 HV; 5 B ; Aluminum HV Winding Matl
With Taps 41.7200, 16770, 15910, 15480
120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mat]
60 Hz
1 Phase
Transformer Weight: 1379.96 lbs.; Height: 48 in.; Width: 39.00 in.; Depth: 37.00 in.
Est. Shipping Dimensions: 1452.86 lbs. Height: 52 in.; Width: 38 in.; Length: 44 in.;
Est. C/C Weight: 718.71 lbs.
65 Temp. Rise;
i HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
4 LV Bushings, 4 Hole "H" spade, Porcelain 1" STUD
50 Gal(s) of Transformer Oil
1 24" Carbon STL Cover, 2 HV Bushing Holes.
11 6 A1652WIOZZM1631
CustProduct-ID: 002-0102
Overhead Distribution Tr e; S - Conventional
10 KVA
No Load: 23 W, at 85 degrees C; Load: 153 Watts at 85 degrees C; Total Loss: 176 Watts
16340 HVj495 L; Copper HV Winding Mad
With Taps i{t 17200, 16770, 15910, 15480
277/480Y LV; 30 BIL; Non-LV Interlaced; Copper LV Winding Mad
60 Hz
1 Phase
Transformer Weight: 257.22 lbs.; Height: 36 in.; Width: 18.00 in.; Depth: 22.00 in.
Est. Shipping Dimensions: 268.22 lbs. Height: 40 in.; Width: 22 in.; Length: 23 in.;
Est. C/C Weight:.138.89 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
I HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
2 LV Bushings, Eye Bolt for #64/0, Porcelain
9.4 Gal(s) of Transformer Oil
1 13.25" Carbon STL Cover, 2 HV Bushing Holes
12 7 A1652W15ZZM1631
CustProduct-ID:002-0152
Overhead Distribution Transformer; S.- Conventional
15 KVA ,
No Load: F
f
r, at 85 degrees C; Load: 186 Watts at 85 degrees C; Total Loss: 217 Watts
16340 HV
With Taps0, 16770, 15910, 15480
277/480Y LV; 30 BIL; Non-LV Interlaced
60 Hz
1 Phase
Transformer Weight: 344.28 lbs.; Height: 36 in.; Width: 20.00 in.; Depth: 24.00 in.
Est. Shipping Dimensions: 358.281bs. Height: 40 in.; Width: 24 in.; Length: 25 in.;
Est. C/C Weight: 194 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
2 LV Bushings, Eye Bolt for #64/0, Porcelain
12.3 Gal(s) of Transformer Oil
1 15.25" Carbon STL Cover, 2 HV Bushing Holes
13 12 A1652W37ZZM1631
CustProduct-ID:002-0372
Overhead Distribution Transformer; S - Conventional
37.5 KVA
No Load: $3"Watts at 85 degrees C; Load: 430 Watts at 85 degrees C; Total Loss: 513 Watts
16340 95 ; Copper HV Winding Mad
With Taps t 200, 16770, 15910, 15480
277/480Y LV; 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mad
60 Hz
1 Phase
Transformer Weight: 464.63 lbs.; Height: 38 in.; Width: 22.00 in.; Depth: 26.00 in.
Est. Shipping Dimensions: 485.631bs. Height: 42 in.; Width: 26 in.; Length: 26 in.;
14 6
15 11
Est. C/C Weight: 260.15 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
2 LV Bushings, Eye Bolt for 42-350MCM, Porcelain
17.4 Gal(s) of Transformer Oil
1 17.5" Carbon STL Cover, 2 HV Bushing Holes
A1652W50ZZM1631
CustProduct-ID:002-05
Overhead Distrib " ransformer; S - Conventional
50 KVA*
No Load;,�Watts at 85 degrees C; Load: 543 Watts at 85 degrees C; Total Loss: 638 Watts
16340 HV 95 BIL; Copper HV Winding Matl
With T at 17200, 16770,15910, 15480
Y LV; 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl
60 Hz
1 Phase
Transformer Weight: 563.57 lbs.; Height: 44 in.; Width: 22.00 in.; Depth: 26.00 in.
Est. Shipping Dimensions: 584.57 lbs. Height: 48 in.; Width: 26 in.; Length: 26 in.;
Est. C/C Weight: 315.3 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
1 HV Neut Bushing, 125kV BEL, 17.75"Creep, 8-2 size eyebolt
2 LV Bushings, Eye Bolt for #2-350MCM, Porcelain
21.6 Gal(s) of Transformer Oil
1 17.5" Carbon STL Cover, 2 HV Bushing Holes
A1652W99ZZM1631
CustProduct-ID:002-1002 F
Overhead Distribution T*sformer; S - Conventional
100 KVA
No Load: 17T at 85 degrees C; Load: 818 Watts at 85 degrees C; TotaI Loss: 993 Watts
16340 HV 95 B , Copper HV Winding Matl
With Taps 17 , 16770, 15910, 15480
277/480Y L 0 BIL; Non-LV Interlaced, Aluminum LV Winding Mat]
60 Hz
1 Phase
Transformer Weight: 1088.11 lbs.; Height: 52 in.; Width: 27.00 in.; Depth: 33.00 in.
Est. Shipping Dimensions: 1152.11 lbs. Height: 56 in.; Width: 36 in.; Length: 40 in.;
Est. C/C Weight: 557.77 lbs.
65 Temp. Rise;
1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No.
1 HV Line Bushing, 125kV BIL, 17.75"Creep; 8-2 size eyebolt
1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt
2 LV Bushings, Double Eye Bolt for 2/0-1000MCK Porcelain
48 Gal(s) of Transformer Oil
1 22" Carbon STL Cover, 2 HV Bushing Holes
Item R X Imp Iexc RegPF* Reg
1 1.45 1.87 2.37 0.52 0.80 2.29
2 1.12 1.93 2.23 0.73 0.80 2.06
Reg@
Reg@ Effi'U* Eff
Eff@ Eff@
.80 PF
1.0 PF
50%PU 100%PU
2.29
1.47 100.00 98.38
98.89 98.38
2.06
1.14 100.00 98.67
99.00 98.67
3
1.21
1.87
2.23
0.45
0.80
2.09
2.09
1.23
100.00
98.64
99.06
98.64
4
1.04
1.98
2.24
0.59
0.80
2.03
2.03
1.06
100.00
98.79
99.11
98.79
5
1.36
1.92
2.27
0.46
0.80
2.18
2.18
1.38
100.00
98.46
98.92
98.46
6
1.11
1.94
2.24
0.47
0.80
2.06
2.06
1.13
100.00
98.73
99.10
98.73
7
0.80
2.81
2.92
0.43
010
2.34
2.34
0.84
100.00
99.09
99.37
99.09
8
1.29
1.87
2.27
0.54
0.80
2.16
2.16
1.31
100.00
98.50
98.91
98.50
9
1.24
2.00
2.35
0.45
0.80
2.19
2.19
1.26
100.00
98.61
99.05
98.61
10
0.97
2.62
2.79
0.34
0.80
2.36
2.36
1.00
100.00
98.91
99.25
98.91
11
1.53
1.64
2.24
0.49
0.80
2.21
2.21
1.54
100.00
98.27
98.79
98.27
12
1.24
1.85
2.23
0.43
0.80
2.11
2.11
1.26
100.00
98.57
98.98
98.57
13
1.15
1.92
2.24
0.67
0.80
2.08
2.08
1.17
100.00
98.65
98.99
98.65
14
1.09
1.95
2.23
0.56
0.80
2.04
2.04
1.10
100.00
98.74
99.09
98.74
15
0.82
2.09
2.24
0.60
0.80
1.91
1.91
0.84
100.00
99.02
99.25
99.02
(*)From Customer Specifications
Item
Eff@
Eff@
Eff@
Eff@
Eff@
Reg@
Reg@
Reg@
NL@
NL@
EXI@
EXI@
25%
50%
75%
100%
125%
.8PF
.9PF
LOPF
105%
110%
105%
110%
1
98.85
98.89
98.67
98.38
98.07
2.29
2.13
1.47
59.00
70.00
0.72
1.18
2
98.83
99.00
98.87
98.67
98.44
2.06
1.86
1.14
103.00
127.00
1.31
3.12
3
99.02
99.06
98.88
98.64
98.38
2.09
1.91
1.23
101.00
121.00
0.65
1.09
4
98.98
99.11
98.98
98.79
98.57
2.03
1.81
1.06
174.00
214.00
1.03
2.39
5
98.86
98.92
98.72
98.46
98.17
2.18
2.02
1.38
58.00
67.00
0.56
0.72
6
99.03
99.10
98.94
98.73
98.49
2.06
1.86
1.13
104.00
125.00
0.68
1.19
7
99.33
99.37
99.25
99.09
98.92
2.34
1.97
0.84
365.00
453.00
0.80
2.20
8
98.78
98.91
98.74
98.50
98.23
2.16
1.98
1.31
66.00
77.00
0.70
1.02
9
99.01
99.05
98.85
98.61
98.34
2.19
1.99
1.26
101.00
121.00
0.65
1.09
10
99.23
99.25
99.10
98.91
98.70
2.36
2.03
1.00
264.00
314.00
0.47
0.77
11
98.71
98.79
98.57
98.27
97.95
2.21
2.09
1.54
26.00
28.00
0.56
0.64
12
98.88
98.98
98.81
98.57
98.31
2.11
1.93
1.26
34.00
38.00
0.50
0.60
13
98.84
98.99
98.86
98.65
98.42
2.08
1.88
1.17
100.00
122.00
1.12
2.46
14
98.98
99.09
98.94
98.74
98.51
2.04
1.83
1.10
114.00
139.00
0.90
1.80
15
99.10
99.25
99.16
99.02
98.85
1.91
1.66
0.84
213.00
265.00
1.15
3.03
EXCEPTIONS TAKEN TO CUSTOMER SPEC TR1-2003 Dated 11/19/2003
WE TAKE EXCEPTION TO PARA. 5.14 IN THAT WE FURNISH AN ANODIZED ALUMINUM NAMEPLATE
INSTEAD OF A STAINLESS STEEL
NAMEPLATE.
NOTES
PLEASE PUT DMSION NEGOTIATION NUMBER, DIVISION NEGOTIATION ITEM NUMBER AND
COMPLETE 10 TO 15 CHARACTER STYLE NUMBER ON THE ORDER AT THE TIME OF ORDER ENTRY. IF
THIS INFORMATION IS NOT COMPLETE AND CORRECT, ORDER IS SUBJECT TO CANCELLATION.
"MODIFICATIONS TO THE QUOTED BILL OF MATERIAL MUST BE REVIEWED WITH ATHENS SALES
ENGINEER PRIOR TO ORDER ENTRY."
OVERHEAD TRANSFORMER LEAD TIMES FOR ITEMS NOT IN STOCK OR PRODUCTION ARE PER THE
CHART BELOW. THESE LEAD T M ES DO NOT INCLUDE THE TIME NECESSARY FOR THE DESIGN OR
ACQUISITION OF SPECIAL OR BOUGHT -OUTSIDE PARTS. ALL LEAD TIMES ARE FROM DATE OF
ORDER ENTRY AT ATHENS TO DATE OF SHIPMENT & ARE SUBJECT TO AVAILABLE PRODUCTION
SPACE AT ORDER ENTRY. CONTACT DIVISION SALES ENGINEER FOR AVAILABILITY AND PRICE
ADJUSTMENT FOR SHORTER LEAD TIME. YOU MUST ENTER A COMPLETE 10 CHARACTER OR 15
CHARACTER STYLE NUMBER AT TIME OF ORDER ENTRY.
KVA
WEEKS
COREFORM 5 - 37.5 KVA 6 - 7 STYLES THAT BEGIN WITH K, L, M, & N
SHELL FORM 5 - 75 KVA 6 - 7 ALL OTHER STYLES
LARGE 100-1000 KVA 7-8
JUMBOS 7-8
3 PHASE 8
LEAD TIME SUBJECT TO AVAILABLE SPACE ARO
NO LOAD LOSSES QUOTED ARE GUARANTEED AVERAGES AT 85 DEGREES CENTIGRADE.
OUR NAMEPLATE IS ENGRAVED AS FOLLOWS: "FILLED WITH MINERAL OIL THAT CONTAINED LESS
THAN 1 P.P.M. P.C.B. AT TIME OF MANUFACTURE".
GENERAL TERMS AND CONDITIONS OF SALE, PPIGTC073003 APPLY
GBent& 19051
• v
ACORD- CERTIFICATE OF LIABILITY INSURANCE
Q;TE,MMIV
;°"""r'
PRODUCER
The HDH GrotgX Inc, P&C
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION
ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE
USX Tower, Suite 1100
HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR
600 Grant Street
ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.
Pittsburgh, PA 15219-2804
INSURERS AFFORDING COVERAGE
NAIC S
INSaX:re
WESCO Mtemational, Inc.
XNSLIRERA: Travelers of NNn
25674
INSURER B: Travelers Co. of ConnscNc
25682
Few StMhSquare, Commeroe Ct #700
1uRER c: American GUaraMee & LhM!Ny Ins.
M47
Pittsbtrglt, PA 15219
INSLm o
INSURER e.
vvV
THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING
ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR
MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH
POLICES, AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
TYPE OF INSURANCE
POLICY NUMBERmsom
LIM"
A
ORAL LIAI MM
CONRWRCIALGENERALUU3ILITY
CLAIMS MADE nXX OCCUR
TC2JGLSA466K204ATI
06104/03
06104104
EACH OCCURRENCE
i
11mORE ED
MED EXP ( *. Too
t
PERSONAL & ADV INJURY
GENERALAGGREGATE
AOOO.000
GEWL AGGREGATE LIMIT APPLIES PER:
POLICY M j LOC
PRODUCTS - COWIOP AM
j&0oo 000
A
B
AUTOMOBILE
UAGIVIT
ANYAUTO
ALL OWNED AUTOS
SCHEDULED AUTOS
W4m AUTOS
Nc�rNowNEDAums
MM Dam
TC2JCAP466K2O26TIL
TC2ECAP466K2038TCT
06104/03
06/04103
06104104
O6I04104
i S LIMIT
$2,000.000
X
tPorp-* Y
$
X
t BODILY INJURY
$
X
X
t
$
Self Mswed
G
GARk6B LMBILM
ANYAUTO
EXCE&$NNBRELLA LIA9LIrf
OCCUR O❑ CLAIMS MADE
OEDUCTISLE
X RETENTION so
AUC374484303
06IM3
OW04104
AUTO ONLY - EA ACCIDENT
OTHER THAN EAAGC
AUTOONLY% AGO
EACH OCCURRENCE
S
'$
,GATE
A2m2m
A
A
wommm coMPElmTm AND
N3AM OVER ETORLTTY
ANYPROPWETORIPARTNERlEXEC1JTME
EXCLUDED?
E!°M
TC2JUB466K197003
TRJUB466K196203
06/04/O3
OW04003
11B104fO4
OWO4fO4
X AT1J
E.L. EACH ACCIDENT
S1000. 0�
E.L. DISEASE - EA EMPLOY
„L,�
1 tlOOL04Q
EA DISE/15E - POLCY UhNT
1 000
OTHER
DESCRIPTION OF OPERATX M J LOCATIONS f VEHICLES f EXCLUSIONS ADDED BY 040ORSENIENTI SPECMU. PROVISIONS
WESCO Damon, MN:- S WESCO International, Inc. S any organization, other than a
pwfimrship orlofnt venture, over which WESCO maintains ownership or majority Mutest
on the effective date of Due Polley.
At the tMw WESCO Is awarded the job for the City of Vernon. the City. Its
(See Attached Descriptions)
City of Vernon (City)
4305 Santa Fe Avenue
Los Angeles, CA 90058
LO ANY OF IN G ABOVE DESCRIBED POLICIES BE "HELLO BEFORE THE EXMRATM
TFEREOF, THE ISSUM INSISTER wu ENDEAVOR TO MAIL _.39 DAYS WRITTEN
tE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, OUT FAILURE TO DO SO ft"
M NO ORUeAMON OR LIANUTY OF ANY NNW UPON THE INSURER ITS AGENTS OR
^""^'""Kvugive) 7 Of 3 M71681M77065 LFO 6 ACORD CORPORATION IM
IMPORTANT
If the certificate holder is an ADDITIONAL INSURED, the poiicy(ies) must be endorsed. A statement
on this certificate does not corder rights to the certificate holder in Neu of such endorsement(s).
If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may
retake an endorsement. A statement on this certificate does not confer rights to the certificate
holder in lieu of such endorsement(s).
DISCLAIMER
The Certitfcate of insurance on the reverse side of this form does not constitute a contract between
the issuing insurer(s), authorized representative or producer, and the certificate hokler, nor does it
affkmativefy or negatively amend, extend or alter the coverage afforded by the policies Rated thereon,
cannon �c � nu.n..nw.
SPECIFICATION NO. TR1-2003
OVERHEAD DISTRIBUTION TRANSFORMERS
CITY OF VERNON
LIGHT AND POWER
November 19, 2003
SPECIFICATION NO. TR1-2003
Approved Manufacturers/Suppliers
1. Cooper Power
c/o Mark Christensen
Utility Products
44-909 Golf Center Pkwy, Suite #12
Indio, CA 92201
Phone: (760) 863-1660
2. ABB Inc.
Attn: Jeff Vivian
2945 Harding Street, Suite 207
Carlsbad, CA 92008
Phone: (760) 720-3156
3. Howard Transformers
c/o Young and Company
530 South Marengo Ave
Pasadena, CA 91101
Phone: (626) 795-9955
4. General Electric Company
c/o Southwest Power
9837 Pioneer Blvd.
Santa Fe Springs, CA 90670
Phone: (562)801-4577
5. Central Moloney
c/o Southcoast Utility Sales
8762 Luss Drive
Huntington Beach, Ca 92646
(Phone): (714) 962-0841
Fax: 714-963-2487
6. Kuhlman Electric Corp.
101 Kuhlman Road
Versailles, KY 40383
(Phone): (800) 395-6932
Fay- R-Q-R7q-Qn47
Prepared by;
Approved by
Kenneth DeDario, P.E.
Director of Light and Power
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
1.0 SCOPE
Supplier shall furnish all work for providing one -phase, 60 Hz, mineral oil filled,
overhead type distribution transformers rated 500 kVA and below for use on the
City of Vernon's overhead distribution system. The transformer sizes that the
City requires are listed in Attachment A. This list does not preclude the
possibility of ordering voltage and KVA ratings not listed under this specification.
In comparing proposals or bids, consideration will not be confined to lowest
ownership cost only. The successful bidder will be one whose product is judged
to best serve the interests of the City of Vernon when first cost, lowest ownership
cost, product, safety, quality, and delivery are considered. The City of Vernon
reserves the right to reject any or all proposals or bids or any part thereof, and to
waive any minor technicalities from the specifications. A contract will be awarded
to the bidder submitting the lowest responsible bid meeting the requirements of
this specification.
2.0 APPLICABLE STANDARDS
A. The transformers shall conform to the applicable sections of the following
standards to the extent referenced in this Specification, and as amended to
the date of this Specification which, by reference, are included as part of this
Specification.
A. C57.12.00
IEEE Standard General .Requirements for Liquid -
Immersed Distribution, Power, and Regulating
Transformers.
B. C57./12.10
Requirements for Transformers 230,000 Volts and
Below, 833/958 through 8,333/10,417 kVA single
phase, and 750/862 through
60,000/80,000/100,000 kVA three phase without
Load Tap Changing; and 3750/4687 through
60,00/80,000/100,000 kVA with Load Tap
Changing -Safety Requirements.
C. C51.12.20
Overhead -Type Distribution Transformers, 500
kVA and Smaller. High Voltage, 34 500 Volts and
Below; Low Voltage 7970/13800Y Volts and
Below
D. C57.12.90
IEEE Standard Test Code for Liquid -Immersed
Distribution, Power, and Regulating Transformers
and IEEE Guide for Short -Circuit Testing of
Distribution and Power Transformers.
E. C57.91
Guide for Loading Mineral -Oil -Immersed
Overhead and Padmounted Transformers Rated
500 kVA and Less with 650C or 550C Average
3of19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
Winding Rise.
F. C57.106 IEEE Guide for Acceptance and Maintenance of
Insulating Oil in Equipment.
o. ill tile event or concoct Detween the codes and standards and this
Specification, Supplier shall notify City of Vernon Light and Power
Department and secure a written clarification before proceeding with the
work.
4of19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
3.0 SERVICE CONDITIONS
3. 1. Environment
A. The transformers shall perform in accordance with all provisions of
the Specification while subject to the service conditions specified in
ANSUIEEE C57.12.00.
B. The transformer shall be suitable for 30 years of use on the City of
Vernon's electric system when installed in accordance with the
service conditions set forth in the latest edition of the ANSUIEEE
C57.12.00, Section 4.0, in its entirety.
3. 2. Seismic and Impact Loading
A. Before and during installation, the transformers shall withstand,
without damage, rough handling such as bouncing on a truck when
filled with insulating medium and impacting against or upon rigid
structures at speeds up to five feet per second, and being lifted by
two bosses or lifting second, and being lifted by two bosses or
lifting bolts at any angle. Following these conditions, the
transformers shall be capable to being energized without a pre-
operational test.
B. After installation and during the 30-year life of transformer,
transformer will be subject to occasional earthquake motions (0.2g
horizontal and 0.13g vertical) along with significant vibrations from
traffic and from adjacent equipment.
3.3 Pre -installation Inspection
The City of Vernon will, at its discretion, provide a pre -installation
inspection of each transformer.
3.4 Operating Duty
A. For its 30-year life, each transformer shall be suitable for operation under
short circuit conditions as stated in the latest editions of ANSUIEEE
C57.12.00 and C5712.90. Supplier shall supply verification that the design
has passed the required short circuit criteria.
5of19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
4.0 RATINGS
4.1 Sizes
The transformers shall be sized as shown in Attachment A.
4.2 High Voltage Ratings
Transformers shall be 60 Hz with BIL ratings and Insulation Class as shown
in the table below.
Transformer High
Insulation Class (KV)
Insulation BIL (KV)
Voltage KV
7.2/12.47Y
15
95
16.34
18
125
4.3 Low Voltage Rating
Transformers shall be 60 Hz with BIL ratings and Insulation Class as shown
in the table below.
Trancfnrmnr I —ar a/..Ia..,.,. 1•__..t_a:__
- - -----
Transformer High
---- �. w• v ...0 w.wa.vvqgN�G
Insulation Class (KV)
IJ LIIiJ
Insulation BIL (KV)
Voltage Volts
120/240
1.2
30
277
1.2
30
6of19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
4.4. Impedances
Transformer impedance shall not be less than those shown in the table
below. All transformer testing to determine transformer impedance shall be
based on the base kVA rating of the transformers 65 degree Celsuis
temperature rise. The transformer impedances shall be shown on the
transformer nameplate.
Minimum Transformer Impedance
VOLTAGE
KVA
%Z
240
10-75
2.0
240
100-167
2.5
240
250
3.0
277
15-100
2.0
277
167-333
2.5
277
500
3.0
5.0 CONSTRUCTION FEATURES
5.1 Coil and Core Construction
A. The transformer core shall be of high efficiency rectangular wound core. .
The core shall be made from one of two processes: single -turn
laminations of high quality, grain oriented silicon core steel. Amorphous
core (Le metallic glasses metal) transformers are not acceptable.
B. The transformer coils shall be designed to maintain their nameplate KVA
rating throughout the normal temperature range of operation which shall
be 650C (80°C hot spot). All materials used shall be of the 65°C, 800C hot
spot class. All materials shall be thoroughly tested for compatibility with all
transformer components before being assembled.
C. The primary coil shall be manufactured from heavy varnish or paper
insulated aluminum or copper wire. The secondary coil shall be
manufactured from full width aluminum strip whose edges are finished to
prevent burrs and insulated with epoxy -diamond paper between layers of
the conductor.
D. All insulating paper used as layer insulation in transformer coil shall be
bonded type, coated on both sides with a thermosetting adhesive and
properly cured prior to impregnating with oil or the coils shall be wound
with primary conductor containing a thermosetting adhesive that when
properly cured will form an effective bond, both turn to turn and layer to
layer.
7of19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
5.2. Insulatina Fluid
A. The transformer insulating fluid shall be standard electrical grade mineral
insulating oil. The insulating oil shall be tested and degassed to assure a
chemically inert oil. The transformers shall be furnished with oil which
meets the requirements specified in ASTM Standard D 3487 for mineral
insulating oil, except that the DBPC content (% by weight) shall not be
less than 0.15. The insulating oil in the equipment shall conform with
ANSI C57.106.
B. All transformer oil shall be tested for polychlorinated biphenyl's (PCBs) per
ASTM D4059 and certified as having no detectable levels of PCB. All oil
furnished by supplier shall not contain any detectable traces of
polychlorinated biphenyls.
C. A sealed tank shall be provided on all transformers
5.3 Taps and Changers
A. The transformers shall be furnished with full capacity high -voltage taps.
The tap changer shall be externally operated and clearly labeled to reflect
that the transformer must be de -energized before operating the tap
changer as required in Section 3.3 of ANSI C57.12.26. Padlocking
provisions shall be available for lever or hotstick operable handles. Tap
changer operating mechanisms shall be permanently identified to show
"De -energized Operation Only". Decals and stencils are not acceptable.
The unit shall have one of the following tap configurations:
Two - 2%% taps above and below rated voltage such as the following:
VOLTAGE FULL CAPACITY TAPS
1 %340 17,200/16,770/15,910/15,480
7,200 7,56017,380/7,020/6,840
B. The tap changer position indicating nameplate shall have numerals or
letters that are clearly legible and of permanent quality. Decals and
stencils are not acceptable.
8of19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
5.4 Pressure Withstand and Pressure Relief
A. An assembly shall be provided that is designed for pressure relief. The
assembly shall remain effectively sealed for overloads and external
secondary short circuits of the duration and magnitude allowed by industry
standards, but shall relieve pressure at a minimum of 8 PSIG. Design
should meet the requirement of the latest edition of the ANSI C57.12.20
paragraph 6.27 for relief of excessive pressure.
B. The valve shall be of the indicating type with weatherproof cover, and
equipped with a pull -ring for hook -stick operation. It shall have 1/4 inch
NPT threads and be located on the tank wall above the oil level in either
segment 2 or 4 as designed in ANSI C57.12.20, Table S2. The valve shall
meet the following minimum operating characteristics:
1. Cracking Pressure: 10 PSIG
2. Re -seal: 5 PSIG
3. Flow Rates: 50 SCFM at 15 PSIG
100 SCFM at 50 PSIG
C. The valve body and various parts of the device shall be corrosion resistant.
Only the following pressure relief devices are acceptable:
I. Circle Seal Model No. P60-383
2. Qualitrol Model No. 202-032-01 or 202-33-01
3. Beta Model Nos. 1712K-1, -5, -6, or Model No 1750K-5.
D. The required electrical clearances between pressure relief valve and live
parts shall be maintained.
5.5 Tank Pressure Withstand
A. Tank withstand should meet the latest edition of NEMA TR1, Part 2.
B. Tank bottom shall have a rolled edge and tank wall base which is three
layers thick.
5.6 Tank Finish
A. Tank covers shall have a slope of 15 degrees for moisture run-off and
100 kVA and below, shall have an insulated coating on the cover
capable of withstanding 15kV at a 2000 volt/sec rate of rise, or equal,
tested per ASTM D149 using 1/4" diameter electrodes, or equal. The
results of design test to confirm this capability shall be submitted for
approval.
9 of 19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
B. The tank coat will be a finish which can withstand a direct blow of 160
inch -pounds per ASTM D-2794-69 for units 100 kVA and below and
meets or exceeds the following as set forth in ANSI C57.12.28:
1. Salt spray for 1000 hours
2. Humidity Test,
3. Abrasion resistance
4. Crosshatch adhesion
5. Oil resistance.
C. The paint on all transformer tanks shall be grayish in color and conform
to Munsell 5BG 7.0/04 with the following tolerances:
1. Hue:
+/-12 (3G and 713)
2. Value:
+/-0.2
3. Chroms:
+/-0.2
5.7 Tank and Covers
A. Transformers shall have bolted covers for all size transformers. One
spare bolt per each transformer shall be provided and included in the bid.
5.7 Internal Lead Identification
A. Internal secondary leads shall be identified with appropriate markings
permanently embossed in the lead that correspond with lead markings on
the nameplate.
5.8 External Features
A. Transformers shall be provided with cover mounted high voltage
porcelain bushings with eyebolt terminals, low voltage porcelain bushings
with eyebolt terminals and ANSI single position support lugs (hanger
brackets) with nameplate on lower bracket. For all transformers rated
above 167 kVA, no support brackets are required.
5.9 Weight and Dimensions
A. The maximum weight for transformers 100 kVA and below shall be
1,400 lbs.
B. All 250, 333, and 500 kVA single phase transformers shall be 'light
weight" transformers. The weights and dimensions of the 'lightweight'
transformers shall not exceed the weights and dimensions specified
below.
10 of 19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
Rating (kVA)
Weight (Ibs)
Height
Inches
Width
Inches
Depth
Inches
250
2,50072
41
38
333
2,800
72
41
38
500
3,300
72
50
42
5.11 Ground Provisions
A. All transformers shall have a tank grounding provision.
5.12 High Voltage Bushings
A. Transformer rated 15 kVA through 167 kVA shall be furnished with two
cover -mounted bushings. High Voltage bushing terminals shall be in
accordance with the latest edition of the ANSI Standard C57.12.20,
paragraph 6.1.2.2.
B. The cover -mounted bushings shall be of the 15kV insulation class for
7kV transformers and 17kV insulation class for 16kV transformers. The
creepage distance of the bushings shall not be less than 15 inches.
C. When the distance between live parts of cover -mounted bushings is
less than 12 inches, the bushings shall be equipped with approved bird
guards. Bird guards that are approved for use on overhead transformers
are:
MANUFACTURER
MODEL NUMBER
Coltec Industries
703803-53
Porcelain Products
65001 through 65019
RTE
0704119b01
Kuhlman Electric
6210209902 assembly
6210208804 assembly
11 of 19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
5.13 Internal High -Voltage Connections
A. Each internal high -voltage lead shall be equipped with either a ring -
tongue or a hook -type connector. Each connector shall be terminated on
a fixed threaded stud, a fixed threaded bolt, or a non -removable threaded
bolt, each having two nuts for holding and locking purposes.
1. Ring -tongued type: The ring -tongue terminals shall have
mechanical and electrical properties so as to contain the high -
voltage leads, without breaking, even under short-circuit conditions.
Bumdy type YAV are typical of the type desired.
2. Hook type: Hook terminals shall meet the same physical
requirements as specified above for ring -tongue terminals. In
addition to the above, both changing and locking nuts shall be held
captive to prevent their complete removal. AMP, Inc. Style No. 3
"Hook" terminals are typical of the type desired.
5.14 Nameplates
A. A stainless steel nameplate shall be attached with non -corrosive
hardware to the inside of the low voltage compartment door. The
nameplate shall not be installed on the rear of the low voltage
compartment area. Diagrams and numbers shall be of the size and
quality such that they can be read from outside the compartment. In
addition to the nameplate requirements shown in ANSI/IEE C57.12.00-
1987, for nameplate A with total weight including oil shall be indicated.
5.15 MSDS
A. The supplier shall be required to provide all applicable Material Safety
Data Sheets with all transformer orders.
6.0 TESTS
6.1 General
A. Transformer tests shall be performed as specified in ANSI Standard
C57.12.00. These test reports shall be provided to the City prior to
shipping. The City will not receive any transformers without the
required test reports.
B. Units shall comply with routine test requirements of ANSI and certified
test reports shall be furnished. The vendor shall provide with returned
bids all applicable documentation of compliance with ANSI design
12 of 19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
tests.
C. The following data shall be submitted with each transformer order:
a. Guaranteed maximum no load (excitation) loss at rated voltage and
110% voltage in Watts. Y
b. Guaranteed maximum load loss in Watts at rated voltage and
110% voltage.
c. Guaranteed maximum total loss in Watts at rated voltage and
110% voltage.
d. Exciting Current in percent at rated voltage and 110% rated
voltage.
e. Percent impedance on base voltage and at the maximum
temperature rise.
f. Efficiencies shall be provided at loading levels of 100%, 75%,
50%, and 25%.
g. Regulation at rated load @ 80% and 100% Power Factor.
h. Two sets of outline drawings showing dimensions, weight, gallons
of oil, gauge of steel in tank walls, cover, bottom, and cooling
radiators and description of accessories. After order is awarded,
the vendor shall submit FINAL drawings.
i. Verification that the transformer design has passed the required
short circuit criteria per Section 3.4 of these specifications.
7.0 OPERATING PERFORMANCE
7.1 General
The Apparatus shall perform in accordance with the conditions set forth in
this Specification.
13 of 19
CITY OF VERNON LIGkT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
8.0 BID EVALUATION
8.1 Total Ownership Cost
The purchase price of transformers shall be evaluated by lowest total
ownership cost. The formula to evaluate Total Owning Cost (TOC):
TOC = C + $4.53/W (PNL in Watts) + $1.1/W (PLL in Watts)
Where TOC is the total ownership cost in dollars, C is the initial cost in
dollars, PNL is the guaranteed maximum no-load loss in watts, and PLL is
the guaranteed maximum load loss in watts
For the determination of the award for the transformer order(s), City will
consider all bids within 5% of the lowest Present Value Cost of
Transformer to be economically equivalent. The City of Vernon realizes it
is impossible to accurately predict economic conditions over the
evaluation period of 30 year s. Reference Section 1, SCOPE, second
paragraph of these specifications.
8.2 Delivery
A delivery date of 16 weeks ARO or less is required. Failure to quote a
delivery schedule within this period may disqualify the bid.
9.0 DOCUMENTATION
9.1 For Bid Evaluation
Bidders shall furnish the following in their bid proposals:
1. Transformer unit price, F.O. B. Soto Yard.
2. Guaranteed maximum no-load loss at rated voltage in watts.
3. Guaranteed maximum load loss in watts at rated voltage and kVA.
4. Percent impedance on rated voltage tap.
5. Two sets of dimension and outline drawings.
14 of 19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
9.2 For Delivery
Supplier shall furnish MSDS and certified test reports and drawings, as
listed in Section 11.1 in this Specification one month before transformers
are shipped. -
These documents shall be submitted to:
City of Vernon
Utilities Department
4305 Santa Fe Avenue
Vernon Ca, 90058
Phone: (323) 583-8811
Attention: Jose Lugo
Electrical Engineer
10. CONTRACT
A. The vendor may be required to execute a purchase contract with City of
Vernon, and may be required to furnish proof of insurance pursuant'to
Attachment B, Insurance Schedule. If required, the vendor shall provide a letter
from its insurance company that certifies the amounts of the insurance policy.
The letter from the insurance company will be in substantially the same form as
the SAMPLE INSURANCE FORM LETTER, which is also included in Attachment
B.
11. SHIPMENT
A. Supplier's quote shall be F.O.B. City of Vernon, Soto Yard located at 2800
Soto Avenue, Vernon Ca 90058.
B. Transformers will be delivered on a flatbed truck for side unloading by
forklift at ground level.
C. Supplier shall notify City 48 hours prior to delivery. All delivery shall be
Monday -Friday, 7:30 AM to 3:00 PM. Contact telephone is (323) 589-
9498 or (323) 585-5192.
D. 15 days prior to shipment, supplier shall furnish certified test reports of the
switch.
E. 15 days prior to shipment, supplier shall furnish three (3) sets of
Operations/Instruction Manuals.
15 of 19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
12. WARRANTY
Supplier shall provide warranty for a minimum of twelve (12) months after
delivery.
16 of 19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
ATTA 0%1 IR 2P&. .
m 1 1 Hl.nivir-N
I A I ranstormer Ratings
Used by the City of Vernon
ITEM
QUANTITY
RATED
VOLTS
(PRIMARY
VOLTS)
RATED
VOLTS
(SECONDARY
VOLTS
RATING
(KVA)
MATERIAL
CODE
1
0
7200/12470Y
120/240
15
001-0151
2
3
7200/12470Y
120/240
25
001-0251
3
5
7200/12470Y
1201240
37.5
001-0371
4
0
7200/12470Y
120/240
50
001-0501
5
6
7200/12470Y
1201240
75
001-0751
6
0
7200/12470Y
120/240
100
001-1001
7
0
7200/12470Y
120/240
167
001-1671
8
0
7200/12470Y
2771480Y
15
001-0152
9
8
7200112470Y
277/480Y
25
001-0252
10
0
7200/12470Y
2771480Y
37.5
001-0372
11
0
2200/1 4470Y
277/480Y
50
001-0502
12
0
7200/12470Y
277/480Y
75
001-0752
13
0
7200112470Y
277/480Y
100
001-1002
14
0
7200/12470Y
277/480Y
167
001-1672
15
0
7200112470Y
277/480Y
250
001-2502
16
0
7200/12470Y
277/480Y
333
001-3332
17
0
7200112470Y
277/480Y
500
001-5002
18
0
16340
120/240
15
002-0151
19
12
16340
120/240
25
002-0251
20
0
16340
120/240
37.5
002-0371
21
15
16340
1201240
50
002-0501
22
0
16340
120/240
75
002-0751
23
0
16340
120/240
100
002-1001
24
016340
120/240
167
002-1671
25
6
16340
2771480Y
10
002-0102
26
7
16340
277/480Y
15
002-0152
27
0
16340
277/480Y
25
002-0252
28
12
16340
277/480Y
37.5
002-0372
29
0
16340
277/480Y
50
002-0502
30
0
16340
2771480Y
75
002-0752
31
11
16340
2771480Y
100
002-1002
32
0
16340
277/480Y
167
002-1672
33
0
16340
277/480Y
250
002-2502
34
0
16340
277/480Y
333
002-3332
35 1
0
16340
277/480Y
500
002-5002
17 of 19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
ATTACHMENT B
INSURANCE SCHEDULE (Vendor)
The Contractor shall provide proof of insurance, including a standard certificate of
insurance, in at least the following amounts and coverage (combined single limit
permitted):
The general liability policy shall contain the following special endorsements which shall
be noted on or attached to the standard certificate of insurance:
An endorsement naming City, its officers, and employees as insureds under the policy.
An endorsement providing City thirty (30) days notice of cancellation or material
reduction of coverage.
An endorsement providing coverage for all operations under City permit and specifying
the activities covered.
Such other endorsement as may be required by addendum hereto.
In addition to the standard certificate of insurance, proof of general and umbrella liability
coverage shall be furnished in the form checked below. Certification of the following
proofs by the insurance agent or broker will not be accepted:
For each policy, a notarized letter from the underwriter or carrier certifying that the
coverage and statements in the standard certificate of insurance (attached thereto) are true
and correct and that the signator is an officer authorized to so certify.
A copy of each policy certified by an officer of the underwriter or carrier and notarized.
18 of 19
CITY OF VERNON LIGHT AND POWER
OVERHEAD TRANSFORMER
TECHNICAL REQUIREMENTS
SAMPLE INSURANCE FORM LETTER
(To be issued on insurance carrier letterhead. This letter must be notarized).
Date:
City of Vernon ("City")
4305 Santa Fe Avenue
Vernon, CA 90058
Attn: Risk Management Department
Re: Insurance for City of Vernon
(description of permit or contract)
Policy Number(s)
Named Insured:
City Clerk:
I hereby certify that the certificate of insurance attached hereto and made a part
hereof by reference truly and accurately represents the above -cited insurance
policies and the insurance
coverage of each for the named insured issued by
(insurance can-ier)
The City of Vernon, its officers, and employees are included in said policies as
additional insureds and the City of Vernon will be provided with thirty (30) days