Resolution No. 83832 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 RESOLUTION NO. 8383 A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF VERNON ACCEPTING THE BID OF WESCO DISTRIBUTION, INC., CENTRAL MOLONEY, INC. AND SOUTHWEST POWER INC. ON BID NO. 1432 FOR THE PURCHASE OF OVERHEAD DISTRIBUTION TRANSFORMERS FOR THE LIGHT AND POWER DEPARTMENT AND APPROVING AND AUTHORIZING THE EXECUTION OF EQUIPMENT PURCHASE CONTRACT AND THE ISSUANCE OF A PURCHASE ORDER RESPECTING SAID BIDS WHEREAS, the Light & Power Department is in need of various one -phase, 60 Hz, mineral oil filled, overhead type distribution transformers (the "Transformers") to replenish the stock for projected service requirements for fiscal year 2003-2004; and WHEREAS, pursuant to Resolution No. 8324 adopted by the City Council of the City of Vernon on December 3, 2003, the City Clerk was directed to give notice inviting sealed proposals or bids for the purchase of the Transformers in accordance with a bid specification provided by the Light and Power Department; and WHEREAS, based upon the bid specification, the Purchasing Department prepared Bid No. 1432 dated December 11, 2003, and sealed bids were opened on January 8, 2004; and WHEREAS, the Light & Power Department reviewed the bids received and approved the bids based upon their analysis of the total ownership cost of each bid in accordance with the bid specification; and WHEREAS, by letter dated February 9, 2004, Bruce V. Malkenhorst, the City Administrator/City Clerk, recommended that Bid No. 1432 be awarded based on a total ownership cost analysis to the 28 11 following: t 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 WESCO Distribution, Inc. for the sum of $31,746.00 (37 Transformers); Central Moloney, Inc. for the sum of $6,303.00 (3 Transformers); and Southwest Power Inc. (General Electric Co.) for the sum of $20,595.00 (31 Transformers). NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF VERNON AS FOLLOWS: SECTION 1: The City Council of the City of Vernon hereby finds and determines that the recitals contained hereinabove are true and correct. SECTION 2: The City Council of the City of Vernon hereby awards Bid No. 1432 to WESCO Distribution, Inc., Central Moloney, Inc. and Southwest Power Inc. and accepts and approves the Equipment Purchase Contract with WESCO Distribution, Inc., a copy of which is attached hereto as Exhibit "A" and made a part hereof. SECTION 3: The City Council of the City of Vernon hereby authorizes the issuance of a purchase order for the purchase of the Transformers pursuant to Bid No. 1432. SECTION 4: All other bids in connection with Bid No. 1432 are rejected. SECTION 5: The City Clerk of the City of Vernon shall certify to the passage of this resolution, and thereupon and thereafter the same shall be in full force and effect. APPROVED AND ADOPTED this 18th day of February, 2004. -tEONIS C. MALBURG, kayor AT T E--- BRUCE V. MALKENHORST, City Clerk - 2 - 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 t STATE OF CALIFORNIA ) ss COUNTY OF LOS ANGELES ) I, BRUCE V. MALKENHORST, City Clerk of the City of Vernon, do hereby certify that the foregoing Resolution, being Resolution No. 8383, was duly adopted by the City Council of the City of Vernon at a regular meeting of the City Council duly held on Wednesday, February 18, 2004, and thereafter was duly signed by the Mayor of the City of Vernon. (SEAL) o' BRUCE V. MALKENHORST, City Clerk - 3 - EXHIBIT 0 s 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 EQUIPMENT PURCHASE CONTRACT THIS AGREEMENT is made, entered into and executed in duplicate originals, either copy of which may be considered and used as the original hereof for all purposes, as of this day of February, 2004, in the City of Vernon, County of Los Angeles, California BY AND BETWEEN THE CITY OF VERNON (hereinafter referred to as the "City") 4305 Santa Fe Avenue Vernon, CA 90058 WESCO DISTRIBUTION, INC. (hereinafter referred to as "WESCO") 10020 Freeman Avenue Santa Fe Springs, CA 90670 WHEREAS, on December 11, 2003, the City requested proposals or bids for 115 various one -phase, 60 Hz, mineral oil filled, overhead type distribution transformers (the "Transformers") (Bid No. 1432) needed by the City's Light and Power Department; and WHEREAS, the City is permitted to accept or reject any or all quotations received on the bid items; and WHEREAS, on or about January 8, 2004, the City received various proposals for the sale of the Transformers identified in Bid No. 1432, with each of the 115 bid items quoted separately; and WHEREAS, on January 5, 2004, WESCO, submitted a bid; and WHEREAS, on January 8, 2004, the City opened the bid submitted by WESCO, as well as other bids for the items identified in Bid No. 1432; and WHEREAS, the City desires to purchase the following bid 1 items from WESCO: three (3) 25 KVA, 7.2 KV 120/240V Transformers; five 2 (5) 37.5 KVA, 7.2 KV 120/240V Transformers; six (6) 50 KVA, 7.2 KV 3 120/240 V Transformers; six (6) 75 KVA, 7.2 KV 120/240V Transformers; 4 eight (8) 25 KVA, 7.2 KV 277/480 Transformers; six (6) 50 KVA, 7.2 KV 5 277/480 Transformers; and three (3) 250 KVA, 7.2 KV 277/480 6 Transformers for a total of thirty-seven (37) Transformers per City of 7 Vernon Specification No. TR1-2003. 8 NOW, THEREFORE, THE PARTIES HERETO DO MUTUALLY AGREE AS SET 9 FORTH HEREIN: 10 1. Purchase. WESCO agrees to sell and deliver to the 11 City a total of thirty-seven (37) Transformers referenced above 12 pursuant to City of Vernon Specification No. TR1-2003, as identified 13 in WESCO's January 5, 2004 bid and which meet the specifications 14 contained in City of Vernon Bid No. 1432, dated December 11, 2003 15 (collectively referred to as the "Bid Documents"). A copy of the Bid 16 Documents are attached hereto as Exhibit "A" and incorporated herein 17 by reference. 18 2. Time of Performance. WESCO's performance shall 19 commence upon the full execution of this Contract and delivery of the 20 transformers and shall be completed by WESCO within 16 weeks after 21 receipt of order. 22 3. Price. The City agrees to purchase thirty-seven (37) 23 Transformers from WESCO for the total sum of Thirty -One Thousand Seven 24 Hundred Forty -Six Dollars and No Cents ($31,746.00). This price 25 includes freight and excludes sales tax. 26 4. Delivery. Consistent with the Bid Documents, WESCO 27 agrees to deliver the thirty-seven (37) Transformers on a flatbed 28 truck for side unloading by forklift at ground level to the City. -2- 1 WESCO shall notify the City 48-hours prior to delivery at (323) 589- 2 9498 to make arrangements for gates to be opened. Delivery shall be 3 scheduled for Monday through Friday between the hours of 7:30 a.m. and 4 3 p.m. Prior to shipment, WESCO shall furnish certified test results 5 of the switch and three (3) sets of Operations/Instruction Manuals. 6 5. Warranties. WESCO warrants title to the Transformers 7 purchased hereunder and any part thereof to be free of any claim or 8 any security interest, lien or encumbrance. WESCO also warrants that 9 the Transformers will be delivered new and shall be free from defects. 10 WESCO shall provide, at a minimum, a one (1) year labor and material 11 warranty to begin upon acceptance of the Transformers by the City. 121 All manufacturers' warranties, any warranties typically provided by 13 WESCO and any other warranties made applicable by law shall apply to 14 the City's purchase of the Transformers. 15 6• Governing Law. The validity, interpretation and 161 Performance of this Contract shall be controlled and construed under 17 the laws of the State of California. 18 7. Forum Selection. Any action brought relating to this 19 Contract shall be brought and held exclusively in a State Court in the 20 County of Los Angeles, California. 21 8. Notices. Notices to the parties, unless otherwise 22 requested in writing, shall be sent to: 23 City: THE CITY OF VERNON ATTN: DOLORES FONSECA 24 PURCHASING ASSISTANT 4305 SANTA FE AVENUE 25 VERNON, CA 90058-0805 26 WESCO: WESCO DISTRIBUTION, INC. ATTN: LESLIE MCCOY 27 BRANCH OPERATIONS MANAGER 10020 FREEMAN AVENUE 28 SANTA FE SPRINGS, CA 90670 -3- 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19' 20 21 22 23 24 25 26 27 28 9. Risk of Loss. Title and risk of loss or damage shall pass to the City and delivery shall be deemed to be complete upon delivery FOB jobsite or upon moving into storage at the City's request, whichever occurs first. 10. Attorneys' Fees. In the event that it becomes necessary for either party to this Agreement to enforce any of the provisions of this Agreement, the parties agree that a court of competent jurisdiction may determine and fix reasonable attorney's fees to be paid to the successful litigant. IN WITNESS WHEREOF, the parties have caused this Agreement to be executed by and through their authorized officers on the date, month and year first written above. ATTEST: BRUCE V. MALKENHORST, City Clerk APPROVED AS TO FORM: ERIC T. FRESCH, City A torney IM CITY OF VERNON LEONIS C. MALBURG, Mayor WESCO DISTRIBUTION, INC. By: Title:Gnc� By: Y � Title: A cs � r-ccTo�' -4- REQUEST FOR QUOTATIONS NOT A PURCHASE ORDER DIRECT ALL INQUIRIES TO: CITY PURCHASING AGENT TELEPHONE (323) 583-8811 CITY OF VERNON, CALIFORNIA PURCHASING DEPARTMENT CITY HALL . 4305 Santa Fe Ave. - Vernon, California 9fm,R ABB TO: Mr. Greg Tagliaferri C/o Wesco is ri u ion, Inc., 10020 Freeman Avenue Santa -Fe Springs, CA 90670 FOR CITY USE ONLY QUOTATION NO. 1432 DATE MAILED 1 _ REC'D BY CITY bl /09/ V g Please quote hereon the lowest net price you can furnish the articles or services specified below. Quote on each item separately. Bidder may qualify quotations as "ail or none by stating so on body of form. City reserves the right to accept or reject quotations received on any or all items. In order to maintain their name on City's Bidder File. Vendor should return thin form whPrhar a nri. n 1. ,, -f-A — __* QUANTITY DESCRIPTION NET UNIT PRICE TOTAL Overhead type distribution transformers, as per City of Vernon Light & Power Specification No. TR1-2003 dated November 19, 2003. F —3 25 KVA, 7.2 KV 120/240V Z(cl Overhead Transformer `J73 -o —5 37.5 KVA, 7.2 KV, 120/240 V Overhead Transformer �� 00 3qyD Co 50 KVA, 7.2 KV, 120/240 V Overhead Transformer 747 are L/ f 92- oa °A_6 75 KVA, 7.2 KV, 120/240 V Overhead Transformer 930 cG ��j ? 25 KVA, 7.2 KV, 277/480 Y Overhead Transformer °o =6 50 KVA, 7.2 KV, 277/480 Y Overhead Transformer �73g c" f-3 250 KVA, 7.2 KV, 277/480 Y Overhead Transformer -----------PLEASE NOTE ---------- Bid number must be indicated on the outside of the envelope; otherwise, bid will not be accepted. IF INSUFFICIENT SPACE PROVIDED ABOVE FOR PROPOSAL, ATTACH RIDER OR SUPPLEMENT. CASH DISCOUNTS QUOTED FOR PERIODS OF LESS THAN 30 DAYS WILL NOT BE CONSIDERED WHEN ORDER IS AWARDED, BIDS RECEIVED IN RESPONSE TO THIS REQUEST FQ� QUOTATION WILL BE OPENE CITY PUR HA 1 G AGENTS OFFICE ON THE 8 th DAY OF iJ d n u a ry ; �g 20 AT-- (p NOTE: Quote prices exclusive of Sales Tax and Excise T e . A. Indicate Sales Tax in this space $.....Tt. ? d.: .i....................... B. Indicate Excise Tax in this space $ ..................................................... ............... B. Above quotations subject to Cash Discount f...... tQ 1',...,,,e. _ C. To be delivered to CITY OF VERNON at.....`t�. . ... {' ..a w r ) t?r n0 pEY We (1) agree to furnish above in .........................................days from receipt of purchase order at prices specified, FOR.............................. ...............\ ..........�.....��.5�...r,.by.',Ior..TY?c:................... // Fi Name DATE...........l....O............................HERE \ yy 1 SIGN HERE....... (.c�� �r►1l;. Ls�.� �... G MAIL TO PURCHASING DEPT. r `"� ` �' 0 P` ' ,,A, b'A ' A.) REQUEST FOR QUOTATIONS NOT A PURCHASE ORDER DIRECT ALL INQUIRIES TO: CITY PURCHASING AGENT TELEPHONE (323) 583-8811 TO: CITY OF VERNON, CALIFORNIA PURCHASING DEPARTMENT CITY HALL 4305 Santa Fe Ave. - Vernon, California 90058 FOR CRY USE ONLY QUOTATION NO. DATE MAILED REC'D BY CITY OPENED BY Please quote hereon the lowest net price you can furnish the articles or services specified below. Quote on each item separately. Bidder may qualify quotations as "all or none" by stating so on body of form. City reserves the right to accept or reject quotations received on any or all items. In order to maintain their name on Citv's Bidder Files, Voandnr chmow rn♦,,.., +t l 4,..,,.....k- &.-- - ____ __ ------ 20 NOTE: Quote prices exclusive of Sales Tax and Excise Taxes. A. Indicate Sales Tax in this space$.................................................................... B. Indicate Excise Tax in this space $........................... .......................... B. Above quotations subject to Cash Discount of .................................................%, F.O.BC. .............................................................. ................................... To be delivered to CITY OF VERNON at ..................... We (1) agree to furnish above in .........................................days from receipt of purchase order at ..... -- specified. FOR .............. Fm! t Kamm �...1�..s.:....................................... (,� n N DATE......... ..`�...r.Je SIGNHERE ...................................................... .�....................................................... MAIL TO PURCHASING DEPT. Lcs ` �` REQUEST FOR QUOTATIONS NOT A PURCHASE ORDER DIRECT ALL INQUIRIES TO: CITY PURCHASING AGENT TELEPHONE (323) 683-8811 TO: CITY OF VERNON, CALIFORNIA PURCHASING DEPARTMENT CITY HALL 4305 Santa Fe Ave. - Vernon, California 90058 I FOR CITY USE ONLY QUOTATION NO. DATE MAILED REC'D BY CITY Please quote hereon the lowest net price you can fumish the articles or services specified below. Quote on each item separately. Bidder may qualify quotations as "all or none" by stating so on body of form. City reserves the right to accept or reject quotations received on any or all items. In order to maintain their name on City's Bidder File, Vendor should return this form whether a nrirp is n„ntprl nr n.,r QUANTITY DESCRIPTION NET UNIT PRICE TOTAL If you have any questions regarding the bid or the attached specifications, please call Jose Lugo (Electrical Engineer) at (323) 583-8811, ext. 276. ------------PLEASE NOTE ---------- Bid number must be indicated on the outside of the envelope; otherwise, bid will not be accepted. IF INSUFFICIENT SPACE PROVIDED ABOVE FOR PROPOSAL, ATTACH RIDER OR SUPPLEMENT. CASH DISCOUNTS QUOTED FOR PERIODS OF LESS THAN 30 DAYS WILL NOT BE CONSIDERED WHEN ORDER IS AWARDED. BIDS RECEIVED IN RESPONSE TO THIS REQUEST FOR QUOTATION WILL BE OPENED IN CITY PURCHASING AGENT'S OFFICE ON THE DAY OF 20 AT NOTE: Quote prices exclusive of Sales Tax and Excise Taxes. A. Indicate Sales Tax in this space$....................................................................B. Indicate Excise Tax in this space $ ..................................................... B. Above quotations subject to Cash Discount of .................................................%, F.O.BC. .................................................................................... .............. To be delivered to CITY OF VERNON at............................................................................ We (I) agree to furnish above in .........................................days from receipt of purchase order atp c Is specified. n FOR..................... `�E�iO........ 4S..rl.......t........... t7f..,..................................... t Finn Name DATE.........F..!!•••�.............................. SIGN HERE.......` `:�°:` v.............................. tsi.t�.s.....S.:.t . ................. MAIL TO PURCHASING DEPT. k r'^ J O�`' ` "ter 12-23-2003 To: LISA GROVES WESCO SANTA FE SPRINGS LISA RE YOUR REQUEST FOR BELOW CUSTOMER DTD 12/12 ATHENS QUOTES AS FOLLOWS, PRICES FIRM IN TRUCKLOAD RELEASES THRU 12/31/04. REF ATHENS NEG NO: SF121631 City of Vernon Contract Effective Date: 12/23/2003 Contract Expiration Date: 12/31 /2004 PLS QUOTE: Shipment Period: 0 1 /0 1/2001-06/30/2001 ITEM QTY PRODUCT ID 1 3 A7312W25ZZM1631 CustProduct-ID: 001-0251 Overhead Distribution Transformer; S - Conventional 25 KVA No Load: 50 Watts at 85 degrees C; Load: 362 Watts at 85 degrees C; Total Loss: 412 Watts 7200/12470Y HV; 95 BIL; Copper HV Winding Mal With Taps at 7560, 7380, 7020, 6840 120/240 LV; 30 * 30 BIL; Non-LV Interlaced, Aluminum LV Winding Mad 60 Hz 1 Phase Transformer Weight: 352.131bs.; Height: 39 in.; Width: 20.00 in.; Depth: 24.00 in. Est. Shipping Dimensions: 366.131bs. Height: 43 in.; Width: 24 in.; Length: 25 in.; Est. C/C Weight: 191.8 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. I HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt 3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain 13.3 Gal(s) of Transformer Oil 1 15.25" Carbon STL Cover, 2 HV Bushing Holes 2 5 A7312W37ZZM1631 CustProduct-ID: 001-03 71 Overhead Distribution Transformer; S - Conventional 37.5 KVA No Load: 85 Watts at 85 degrees C; Load: 420 Watts at 85 degrees C; Total Loss: 505 Watts 7200/12470Y HV; 95 BIL; Copper HV Winding Matl With Taps at 7560, 7380, 7020, 6840 120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mad 60 1 Phase Transformer Weight: 466.99 lbs.; Height: 39 in.; Width: 22.00 in.; Depth: 27.00 in. Est. Shipping Dimensions: 487.99 lbs. Height: 43 in.; Width: 26 in.; Length: 26 in.; Est. C/C Weight: 262.35 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt 3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain 17.4 Gal(s) of Transformer Oil 1 17.5" Carbon STL Cover, 2 HV Bushing Holes A7312W50ZZM1631 CustProduct-ID: 001-0501 Overhead Distribution Transformer; S = Conventional 50 KVA No Load: 86 Watts at 85 degrees C; Load: 605 Watts at 85 degrees C; Total Loss: 691 Watts 7200/12470Y HV; 95'BIL; Copper HV Winding Matl With Taps at 7560, 7380, 7020, 6840 120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl 60 Hz 1 Phase / Transformer Weight: 592.85 lbs.; Height: 48 in.; Width: 22.00 in.; Depth: 27.00 in. Est. Shipping Dimensions: 613.85 lbs. Height: 52 in.; Width: 26 in.; Length: 26 in.; Est. C/C Weight: 306.44 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt I HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt 3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain 25.8 Gal(s) of Transformer Oil 1 17.5" Carbon STL Cover, 2 HV Bushing Holes 4 6 - A7312W75ZZM1631 CustProduct-ID: 001-0751 Overhead Distribution Transformer; S - Conventional 75 KVA No Load: 144 Watts &85 degrees C; Load: 779 Watts at 85 degrees C; Total Loss: 922 Watts 7200/12470Y HV; 95 BIL; Copper HV Winding Mad With Taps at 7560, 7380, 7020, 6840 120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mad 60 Hz 1 Phase w� Transformer Weight: 840.981bs.; Height: 52 in.; Width: 25.00 in.; Depth: 31.00 in. Est. Shipping Dimensions: 872.98 lbs. Height: 56 in.; Width: 32 in.; Length: 33 in.; Est. C/C Weight: 412.26 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt 3 LV Bushings, Eye Bolt for #1-500MCM, Porcelain 39 Gal(s) of Transformer Oil 1 20" Carbon STL Cover, 2 HV Bushing Holes A7352W25ZZM1631 CustProduct-ID: 001-0252 Overhead Distribution Transformer; S - Conventional 25 KVA No Load: 51 Watts at_Z degrees C; Load: 341 Watts at 85 degrees C; Total Loss: 392 Watts 7200/12470Y HV; 95 BIL; Aluminum HV Winding Mad With Taps at 7560, 7380, 7020, 6840 277/480Y LV; 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl 60 Hz I Phase Transformer Weight: 461.79 lbs.; Height: 39 in.; Width: 22.00 in.; Depth: 26.00 in. Est. Shipping Dimensions: 422.79 lbs. Height: 43 in.; Width: 26 in.; Length: 26 in.; Est. C/C Weight: 198.42 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt I HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt 2 LV Bushings, Eye Bolt for #6-4/0, Porcelain 17.8 Gal(s) of Transformer Oil 1 17.5" Carbon STL Cover, 2 HV Bushing Holes 6 6 A7352W50ZZM1631 CustProduct-ID: 001-0502 Overhead Distribution Transformer; S - Conventional 50 KVA No Load: 88 Watts 05 degrees C; Load: 557 Watts at 85 degrees C; Total Loss: 645 Watts 7200/12470Y HV; 95 B1L; Copper HV Winding Mad With Taps at 7560, 7380, 7020, 6840 277/480Y LV; 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mad 60 Hz 1 Phase Transformer Weight: 561.96 lbs.; Height: 44 in.; Width: 22.00 in.; Depth: 26.00 in. Est. Shipping Dimensions: 582.96 lbs. Height: 48 in.; Width: 26 in.; Length: 26 in.; Est. C/C Weight: 315.26 lbs. 65 Temp. Rise;. 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt 2 LV Bushings, Eye Bolt for #2-350MCM, Porcelain 21.4 Gal(s) of Transformer Oil 1 17.5" Carbon STL Cover, 2 HV Bushing Holes A7352W52ZZM1631 CustProduct-ID: 001-2502 Overhead Distribution Transformer; S - Conventional 250 KVA No Load: 299 Watt�,at 85 degrees C; Load: 1998 Watts at 85 degrees C; Total Loss: 2297 Watts 7200/12470Y HV; 95 BIL With Taps at 7560, 7380, 7020, 6840 277/480Y LV; 30 BIL; Non-LV Interlaced 60 Hz 1 Phase ,/ Transformer Weight: 1744.77 lbs.; Height: 57 in.; Width: 39.00 in.; Depth: 33.00 in. Est. Shipping Dimensions: 1817.77 lbs. Height: 61 in.; Width: 30 in.; Length: 30 in.; Est. C/C Weight: 919.3 lbs. 65 Temp. Rise; 1 HV Tap Chgr, ABB, Ext (lever) setscrew lockable handle, 5 Po 1 HV Line Bushing, 125kV BEL, 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 2 LV Bushings, 4 Hole "H" spade, Porcelain 1" STUD 65 Gal(s) of Transformer Oil 1 24" Carbon STL Cover, 2 HV Bushing Holes 12 A1612W25ZZM1631 CustProduct-ID: 002-0251 Overhead Distribution Transformer; S - Conventional 25 KVA No Load: 57 Watts at 85 degrees C; Load: 323 Watts at 85 degrees C; Total Loss: 380 Watts 16340 HV4 5 BIL; Aluminum HV Winding Mad tt ,, g With Taps`a 200, 16770, 15910, 15480 120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mad 60 Hz 1 Phase Transformer Weight: 404.9 lbs.; Height: 38 in.; Width: 22.00 in.; Depth: 27.00 in. Est. Shipping Dimensions: 425.9 lbs. Height: 42 in.; Width: 26 in.; Length: 26 in.; Est. C/C Weight: 202.83 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. I HV Line Bushing, 125kV BIL., 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain 17.6 Gal(s) of Transformer Oil 1 17.5" Carbon STL Cover, 2 HV Bushing.1joles 9 21 A1612W50ZZMKransformer; CustProduct-ID: Overhead DistribS - Conventional 50 KVA No Load: ; Load: 620 Watts at 85 degrees C; Total Loss: 706 Watts 16340 HV,95 Bnding Mad With Taps 17 , 16770, 15910, 15480 120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl 60 Hz I Phase Transformer Weight: 593.6 lbs.; Height: 48 in.; Width: 22.00 in.; Depth: 27.00 in. Est. Shipping Dimensions: 614.6 lbs. Height: 52 in.; Width: 26 in.; Length: 26 in.; Est. C/C Weight: 308.65 tbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. I HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, 125kV BIL., 17.75"Creep, 8-2 size eyebolt 3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain 25.6 Gal(s) of Transformer Oil 1 17.5" Carbon STL Cover, 2 HV Bushing Holes 10 3 A1612W67ZZM1631r CustProduct-ID: 002-1671 Overhead Distribution T_ raniformer; S -Conventional 167 KVA No Load: 2jW" at 85 degrees C; Load: 1616 Watts at 85 degrees C; Total Loss: 1841 Watts 16340 HV; B ;Aluminum HV Winding Matl With Taps 00, 16770, 15910, 15480 120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mad 60 Hz / I Phase Transformer Weight: 1379.86 lbs.; Height: 48 in.; Width: 39.00 in.; Depth: 37.00 in. Est. Shipping Dimensions: 1452.86 lbs. Height: 52 in.; Width: 38 in.; Length: 44 in.; Est. C/C Weight: 718.71 lbs. 65 Temp. Rise; I HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. I HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 4 LV Bushings, 4 Hole "H" spade, Porcelain V STUD 50 Gal(s) of Transformer Oil 1 24" Carbon STL Cover, 2 HV Bushing Holes 11 6 A1652WIOZZM1631 k CustProduct-ID: 002-0102 Overhead Distribution T er; S -Conventional 10 KVA No Load: 23 W at 85 degrees C; Load: 153 Watts at 85 degrees C; Total Loss: 176 Watts 16340 HVI 95 ; Copper HV Winding Mat] With Taps kt4 '200, 16770, 15910, 15480 277/480Y LV; 30 BIL; Non-LV Interlaced; Copper LV Winding Matl 60 Hz 1 Phase Transformer Weight: 257.22 lbs.; Height: 36 in.; Width: 18.00 in.; Depth: 22.00 in. Est. Shipping Dimensions: 268.22 lbs. Height: 40 in.; Width: 22 in.; Length: 23 in.; Est. C/C Weight:.138.89 lbs. 65 Temp. Rise; I HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 2 LV Bushings, Eye Bolt for #6-4/0, Porcelain 9.4 Gal(s) of Transformer Oil 1 13.25" Carbon STL Cover, 2 HV Bushing Holes 12 7 A1652W15ZZM1631 "> CustProduct-ID:002-0152 Overhead Distribution Transformer; S.- Conventional 15 KVA No Load: 3h'VP at 85 degrees C; Load: 186 Watts at 85 degrees C; Total Loss: 217 Watts 163407 6340 HV 95 With Taps a 00, 16770, 15910, 15480 277/480Y LV; 30 BIL; Non-LV Interlaced 60 Hz 1 Phase Transformer Weight: 344.28 lbs.; Height: 36 in.; Width: 20.00 in.; Depth: 24.00 in. Est. Shipping Dimensions: 358.28 lbs. Height: 40 in.; Width: 24 in.; Length: 25 in.; Est. C/C Weight: 194 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 2 LV Bushings, Eye Bolt for #64/0, Porcelain 12.3 Gal(s) of Transformer Oil 1 15.25" Carbon STL Cover, 2 HV Bushing Holes 13 12 A1652W37ZZM1631 , CustProduct-ID:002-0372 i Overhead Distribution Transformer; 'S - Conventional 37.5 KVA No Load: , "Watts at 85 degrees C; Load: 430 Watts at 85 degrees C; Total Loss: 513 Watts 16340 95 ; Copper HV Winding Matl With TapsNqW200, 16770, 15910, 15480 277/480Y LV; 30 BIL; Non-LV Interlaced-, Aluminum LV Winding Mad 60 Hz 1 Phase Transformer Weight: 464.63 lbs.; Height: 38 in.; Width: 22.00 in.; Depth: 26.00 in. Est. Shipping Dimensions: 485.63 lbs. Height: 42 in.; Width: 26 in.; Length: 26 in.; Est. C/C Weight: 260.15 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, 125kV BIL., 17.75"Creep, 8-2 size eyebolt I HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 2 LV Bushings, Eye Bolt for #2-350MCM, Porcelain 17.4 Gal(s) of Transformer Oil 1 17.5" Carbon STL Cover, 2 HV Bustling Holes 14 6 A1652W5072M1631 CustProdud-ID: 002-05 Overhead Distn ransformer; S - Conventional 50 KV No YY Watts at 85 degrees C; Load: 543 Watts at 85 degrees C; Total Loss: 638 Watts 1635 BIL; Copper HV Winding Matl Wit 17200, 16770, 15910, 15480 V; 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl 60 Hz 1 Phase Transformer Weight: 563.57 lbs.; Height: 44 in.; Width: 22.00 in.; Depth: 26.00 in. Est. Shipping Dimensions: 584.57 lbs. Height: 48 in.; Width: 26 in.; Length: 26 in.; Est. C/C Weight: 315.3 lbs. 65 Temp. Rise; I HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, 125kV BIL., 17.75"Creep, 8-2 size eyebolt 2 LV Bushings, Eye Bolt for #2-350MCM, Porcelain 21.6 Gal(s) of Transformer Oil 1 17.5" Carbon STL Cover, 2 HV Bushing Holes 15 11 A1652W997ZM1631 CustProduct-ID:002-1002 Overhead Distribution Tpsformer; S - Conventional 100 KVA No Load: 1 - . at 85 degrees C; Load: 818 Watts at 85 degrees C; Total Loss: 993 Watts 16340 HV 95 B , Copper HV Winding Matl With Taps 13M, 16770, 15910, 15480 277/480Y L , 0 BIL; Nan-LV Interlaced; Aluminum LV Winding Mat] 60 Hz 1 Phase Transformer Weight: 1088.11 lbs.; Height: 52 in.; Width: 27.00 in.; Depth: 33.00 in. Est. Shipping Dimensions: 1152.11 lbs. Height: 56 in.; Width: 36 in.; Length: 40 in.; Est. C/C Weight: 557.77 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 1 HV.Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 2 LV Bushings, Double Eye Bolt for 2/0-1000MCK Porcelain 48 Gal(s) of Transformer Oil 1 22" Carbon STL Cover, 2 HV Bushing Holes Item R X Imp Iexc RegPF* Reg Reg@ Reg@ EAU* Eff Eff@ Ewa .80 PF 1.0 PF 50%PU 100%PU 1 1.45 1.87 2.37 0.52 0.80 2.29 2.29 1.47 100.00 98.38 98.89 98.38 2 1.12 1.93 2.23 0.73 0.80 2.06 2.06 1.14 100.00 98.67 99.00 98.67 3 1.21 1.87 2.23 0.45 0.80 2.09 2.09 1.23 100.00 98.64 99.06 98.64 4 1.04 1.98 2.24 0.59 0.80 2.03 2.03 1.06 100.00 98.79 99.11 98.79 5 1.36 1.82 2.27 0.46 0.80 2.18 2.18 1.38 100.00 98.46 98.92 98.46 6 1.11 1.94 2.24 0.47 0.80 2.06 2.06 1.13 100.00 98.73 99.10 98.73 7 0.80 2.81 2.92 0.43 0.80 2.34 2.34 0.84 100.00 99.09 99.37 99.09 8 1.29 1.87 2.27 0.54 0.80 2.16 2.16 1.31 100.00 98.50 98.91 98.50 9 1.24 2.00 2.35 0.45 0.80 2.19 2.19 1.26 100.00 98.61 99.05 98.61 10 0.97 2.62 2.79 0.34 0.80 2.36 2.36 1.00 100.00 98.91 99.25 98.91 11 1.53 1.64 2.24 0.49 0.80 2.21 2.21 1.54 100.00 9827 98.79 98.27 12 1.24 1.85 2.23 0.43 0.80 2.11 2.11 1.26 100.00 98.57 98.98 98.57 13 1.15 1.92 2.24 0.67 0.80 2.08 2.08 1.17 100.00 98.65 98.99 98.65 14 1.09 1.95 2.23 0.56 0.80 2.04 2.04 1.10 100.00 98.74 99.09 98.74 15 0.82 2.09 2.24 0.60 0.80 1.91 1.91 0.94 100.00 99.02 99.25 99.02 (*)From Customer Specifications Item Eff@ Efl@ Eff@ EfI@ EM, Reg@ Reg@ Reg@ NL@ NL@ EXI@ EXI@ 25% 50% 75% 1000/9 125% .8PF 9PF LOPF 105% 110% 105% 110% 1 98.85 98.89 98.67 98.38 98.07 2.29 2.13 1.47 59.00 70.00 0.72 1.18 2 98.83 99.00 98.87 98.67 98.44 2.06 1.86 1.14 103.00 127.00 1.31 3.12 3 99.02 99.06 98.88 98.64 98.38 2.09 1.91 1.23 .101.00 121.00 0.65 1.09 4 98.98 99.11 98.98 98.79 98.57 2.03 1.81 1.06 174.00 214.00 1.03 2.39 5 98.86 98.92 98.72 98.46 98.17 2.18 2.02 1.38 58.00 67.00 0.56 0.72 6 99.03 99.10 98.94 98.73 98.49 2.06 1.86 1.13 104.00 125.00 0.68 1.19 7 99.33 99.37 99.25 99.09 98.92 2.34 1.97 0.84 365.00 453.00 0.80 2.20 8 98.78 98.91 98.74 98.50 98.23 2.16 1.98 1.31 66.00 77.00 0.70 1.02 9 99.01 99.05 98.85 98.61 98.34 2.19 1.99 1.26 101.00 121.00 0.65 1.09 10 99.23 99.25 99.10 98.91 98.70 2.36 2.03 1.00 264.00 314.00 0.47 0.77 11 98.71 98.79 98.57 98.27 97.95 2.21 2.09 1.54 26.00 28.00 0.56 0.64 12 98.88 98.98 98.81 98.57 98.31 2.11 1.93 1.26 34.00 38.00 0.50 0.60 13 98.84 98.99 98.86 98.65 98.42 2.08 1.88 1.17 100.00 122.00 1.12 2.46 14 98.98 99.09 98.94 98.74 98.51 2.04 1.83 1.10 114.00 139.00 0.90 1.80 15 99.10 99.25 99.16 99.02 98.85 1.91 1.66 0.84 213.00 265.00 1.15 3.03 EXCEPTIONS TAKEN TO CUSTOMER SPEC TR1-2003 Dated 11/19/2003 WE TAKE EXCEPTION TO PARA. 5.14 IN THAT WE FURNISH AN ANODIZED ALUMINUM NAMEPLATE INSTEAD OF A STAINLESS STEEL NAMEPLATE. NOTES PLEASE PUT DIVISION NEGOTIATION NUMBER, DIVISION NEGOTIATION ITEM NUMBER AND COMPLETE 10 TO 15 CHARACTER STYLE NUMBER ON THE ORDER AT THE TIME OF ORDER ENTRY. IF THIS INFORMATION IS NOT COMPLETE AND CORRECT, ORDER IS SUBJECT TO CANCELLATION. "MODIFICATIONS TO THE QUOTED BILL OF MATERIAL MUST BE REVIEWED WITH ATHENS SALES ENGINEER PRIOR TO ORDER ENTRY." OVERHEAD TRANSFORMER LEAD TIMES FOR ITEMS NOT IN STOCK OR PRODUCTION ARE PER THE CHART BELOW. THESE LEAD TIMES DO NOT INCLUDE THE TIME NECESSARY FOR THE DESIGN OR ACQUISITION OF SPECIAL OR BOUGHT -OUTSIDE PARTS. ALL LEAD TIMES ARE FROM DATE OF ORDER ENTRY AT ATHENS TO DATE OF SHIPMENT & ARE SUBJECT TO AVAILABLE PRODUCTION SPACE AT ORDER ENTRY. CONTACT DMSION SALES ENGINEER FOR AVAILABILITY AND PRICE ADJUSTMENT FOR SHORTER LEAD TIME. YOU MUST ENTER A COMPLETE 10 CHARACTER OR 15 CHARACTER STYLE NUMBER AT TIME OF ORDER ENTRY. KVA COREFORM 5 - 37.5 KVA SHELL FORM 5 - 75 KVA LARGE 100-1000 KVA JUMBOS 3 PHASE WEEKS 6 - 7 STYLES THAT BEGIN WITH K, L, M, & N 6 - 7 ALL OTHER STYLES 7-8 7-8 8 LEAD TIME SUBJECT TO AVAILABLE SPACE ARO. NO LOAD LOSSES QUOTED ARE GUARANTEED AVERAGES AT 85 DEGREES CENTIGRADE. OUR NAMEPLATE IS ENGRAVED AS FOLLOWS: "FILLED WITH MINERAL OIL THAT CONTAINED LESS THAN 1 P.P.M. P.C.B. AT TIME OF MANUFACTURE". GENERAL TERMS AND CONDITIONS OF SALE, PPIGTC073003 APPLY rn....us. tS Q Ar CORD,u CERTIFICATE OF LIABILITY INSURANCEPRODUCER ' 01107104 The HOH Grog. Inc. PNhG USX Toww, Suits 1100 600 Grant Street THIS CERTIFICATE IS ISSUED AS A MATTER OF INFO ATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. INSURERS AFFORDING COVERAGE NAIC III Pittsburgh, PA 152W2804 INSURED WESCO hrtemationa�, Inc. Four Station Square, Commerce CL N>e700 Pittsburgh, PA 15219 INSURER& Travelers i of UNn 25674 IISURERB: Tfal/Nefs Co. of COrN1eGiC 25682 *mxv R Q American Guarantee & Liability Ins. 26247 INSURER D: COVERAGES I SURER E: THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE LSSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES, AGGREGATE LIMITS SHOYMM MAY HAVE BEEN REDUCED BY PAID CLAIMS, TYPE OP I SURMICE POLICY NUMBER DATE LI MITO A GENERA. UABILITY �0OWJERCKLGENEIWUAWrY CLAMS MADE Q OCCUR TC2JGLSA466K204ATI O604103 OW04104 EACH OOCURREWW $3,000,N X TO MEDEXP — n i300 00O i1 000 — PERSONAL & AM WMY $1 000 000 GENERA, AGGREGATE KOOO.000 GENRL AGGREGATE UMiT APPLIES PEP-1PRODUCTS POLICY PRO LOC JECT - COMPIOP AGG 1201.0d�20 OOO 000 A B AUTOMOBILE U ASILITY ANYAUTO ALL OWNED AUTOS SCFiI�Ik ED AUTOS I# MMTOS NONOWEDAUTOS Phys. Dam TC2JCAP4661C2026 nL TC2ECAP466K2038TCT 06104103 OW04103 06104104 OW04104 LIAR $2.000.000 X BODILY INJURY (Pa P—) S X tPBODILYN Y j X X 1 _ Solt Insured C A A GARAGE LIABILITY ANYAARO O°C MOM' ► X occuR CLAIMS MADE ROEDUCTIBI E X RETENTION _AO woRma comes EIATKNN AND EMPLOYE LIABILITY ANY PROFAETORf EARTNERfaECUTI� OF�lMBdBER QICLUDE07 I drsab wider PROVLStDINS bskw OTNFJN UC374484303 TC2JUB466K197003 TRJUB46WI98M OW04l03 OW04103 061041*03 OW04104 06104104 OW04104 AUTO ONLY - EA ACCIDENT OTHER THAN EAAOC AUTO ONLY: AGO EAaHNOccuT:ReNce S i AGGREGATE Q00 X A oTN i E.LEACHACCEfENIT $10000,000 E.L DISEASE - EA EbW 0 100 1000 E,L DISEASE - POLICY LIMIT $1,0N.ON DESCRIPTION OF OPERATIONS i LOCATIONS I VEHICLES I E MUSKM ADDED BY ENDORSEMENT SPECIAL PROVISIONS WESCO Dlsf txdloo, Inc. a WESCO International, IM a any organization, other than a PwbwshlP or Joint venture, over Which WESCO maintains ownership or majofity interest on the effective date of the policy. At the time WESCO Is awarded the job for the City of Vernon, the City, its (See Attached Descriptions) CERTIMATF W N rWD City of Vernon (city) 4305 Santa Fe Avenue Los Angeles, CA 90058 ACORD 25 (2 IMS)1 of 3 OSS7168IM77065 LD ANY OF THE ABOVE DESCRIBED POLICES BE CANCELLED BEFORE THE EXPIRATION THEREOF, THE ISSUM INSURER WILL ENDEAVOR TO MAIL In DAYS WRITTEN ;E TO THE CERTIFICATE HOLDER NAMED TO THE LEFT. BUY FAILURE TO DO SO SHALL IE NO OBLIGATION OR LIASILM OF ANY KIPS UPON THE INSURER. ITS AGENTS OR LFO 0 ACORD IMPORTANT If the certificate holder Is an ADDITIONAL INSURED, the poky(ies) must be endorsed. A statement on this certificate does not confer ruts to the certificate holier In Neu of such endorsement(s). If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement, A statement on this MWlcate does not confer rights to the certificate holder In lieu of such endorsement(s). DISCLAIMER The Ce WK*te of Insurance on the reverse side of this form does not constitute a contract between the issuing insurer(s), authorized representative or producer, and the certificate holder, nor does it affirmatively or negatively amend, extend or alter the coverage afforded by the policies listed thereon. ACORD 25S r2 IMI •s ... SPECIFICATION NO. TR1-20.03 OVERHEAD DISTRIBUTION TRANSFORMERS CITY OF VERNON LIGHT AND POWER November 19, 2003 SPECIFICATION NO. TR1-2003 Approved Manufacturers/Suppliers I. Cooper Power c/o Mark Christensen Utility Products 44-909 Golf Center Pkwy, Suite #12 Indio, CA 92201 Phone: (760) 863-1660 2. ABB Inc. Attn: Jeff Vivian 2945 Harding Street, Suite 207 Carlsbad, CA 92008 Phone: (760) 720-3156 3. Howard Transformers c/o Young and Company 530 South Marengo Ave Pasadena, CA 91101 Phone: (626) 795-9955 4. General Electric Company c/o Southwest Power 9837 Pioneer Blvd. Santa Fe Springs, CA 90670 Phone: (562)801-4577 5. Central Moloney c/o Southcoast Utility Sales 8762 Luss Drive Huntington Beach, Ca 92646 (Phone): (714) 962-0841 Fax: 714-963-2487 6. Kuhlman Electric Corp. 101 Kuhlman Road Versailles, KY 40383 (Phone): (800) 395-6932 Fzxv- 52fZQ Q'77 ones Prepared by: Approved by rwililem ueuano, P.E. Director of Light and Power CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 1.0 SCOPE Supplier shall furnish all work for providing one -phase, 60 Hz, mineral oil filled, overhead type distribution transformers rated 500 kVA and below for use on the City of Vernon's overhead distribution system. The transformer sizes that the City requires are listed in Attachment A. This list does not preclude the possibility of ordering voltage and KVA ratings not listed under this specification. In comparing proposals or bids, consideration will not be confined to lowest ownership cost only. The successful bidder will be one whose product is judged to best serve the interests of the City of Vernon when first cost, lowest ownership cost, product, safety, quality, and delivery are considered. The City of Vernon reserves the right to reject any or all proposals or bids or any part thereof, and to waive any minor technicalities from the specifications. A contract will be awarded to the bidder submitting the lowest responsible bid meeting the requirements of this specification. 2.0 APPLICABLE STANDARDS A. The transformers shall conform to the applicable sections of the following standards to the extent referenced in this Specification, and as amended to the date of this Specification which, by reference, are included as part of this Specification. A. C57.12.00 IEEE Standard General Requirements for Liquid - Immersed Distribution, Power, and Regulating Transformers. B. C57./12.10 Requirements for Transformers 230,000 Volts and Below, 833/958 through 8,333/10,417 kVA single phase, and 750/862 through 60,000/80,0o0/100,000 kVA three phase without Load Tap Changing; and 3750/4687 through 60,00/80,000/100,000 kVA with Load Tap C. G57.12.20 Changing -Safety Requirements Overhead -Type Distribution Transformers, 500 kVA and Smaller. High Voltage, 34 500 Volts and Below; Low Voltage 7970/13800Y Volts and D. C57.12.90 Below IEEE Standard Test Code for Liquid -Immersed Distribution, Power, and Regulating Transformers and IEEE Guide for Short -Circuit Testing of Distribution and Power Transformers. E. C57.91 Guide for Loading Mineral -Oil -Immersed Overhead and Padmounted Transformers Rated 500 kVA and Less with 650C or 550C Average 3of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS Winding Rise. F. (:57.106 IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment. 6, In the event of conflict between the codes and standards and this Specification, Supplier shall notify City of Vernon Light and Power Department and secure a written clarification before proceeding with the work., 4of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 3.0 SERVICE CONDITIONS 3. 1. Environment A. The transformers shall perform in accordance with all provisions of the Specification while subject to the service conditions specified in y ANSI/IEEE C57.12.00. B. The transformer shall be suitable for 30 years of use on the City of Vernon's electric system when installed in accordance with the service conditions set forth in the latest edition of the ANSI/IEEE C57.12.00, Section 4.0, in its entirety. 3. 2. Seismic and Impact Loading A. Before and during installation, the transformers shall withstand, without damage, rough handling such as bouncing on a truck when filled with insulating medium and impacting against or upon rigid structures at speeds up to five feet per second, and being lifted by two bosses or lifting second, and being lifted by two bosses or lifting bolts at any angle. Following these conditions, the transformers shall be capable to being energized without a pre- operational test. B. After installation and during the 30-year life of transformer, transformer will be subject to occasional earthquake motions (0.2g horizontal and 0.13g vertical) along with significant vibrations from traffic and from adjacent equipment. 3.3 Pre -installation Inspection The City of Vernon will, at its discretion, provide a pre -installation inspection of each transformer. 3.4 O erating Duty A. For its 30-year life, each transformer shall be suitable for operation under short circuit conditions as stated in the latest editions of ANSI/IEEE C57.12.00 and C5712.90. Supplier shall supply verification that the design has passed the required short circuit criteria. 5of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 4.0 RATINGS 4.1 Sizes The transformers shall be sized as shown in Attachment A. 4.2 High Voltage Ratings Transformers shall be 60 Hz with BIL ratings and Insulation Class as shown in the gable below. Tr.a.a.�.. r..,.�_ ae �a_ a • "�^..• aaava 111 11 V Vlld G m--pon tonaracteristics Transformer High Insulation Class (KV) Insulation BIL (KV) Voltage KV 7.2/12.47Y 15 95 16.34 18 125 4.3 Low Voltage Ratinq Transformers shall be 60 Hz with BIL ratings and Insulation Class as shown in the table below. Tr --- f ...r..._ 1 ai_u _ - - --- Transformer High Voltage(Volts) •• • vain G 111'U1dl1Un l/naracteristics Insulation Class (KV) Insulation BIL (KV) 120/240 1.2 30 277 1.2 30 6of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 4.4. Impedances Transformer impedance shall not be less than those shown in the table below. All transformer testing to determine transformer impedance shall be based on the base kVA rating of the transformers 65 degree Celsuis temperature rise. The transformer impedances shall be shown on the transformer nameplate. Minimum Transformer Impedance VOLTAGE 240 KVA 10-75 %Z 2.0 240 100-167 2.5 240 250 3.0 277 15-100 2.0 277 167-333 2.5 277 500 3.0 5.0 CONSTRUCTION FEATURES 5.1 Coil and Core Construction A. The transformer core shall be of high efficiency rectangular wound core. . The core shall be made from one of two processes: single -turn laminations of high quality, grain oriented silicon core steel. Amorphous core (i.e metallic glasses metal) transformers are not acceptable. B. The transformer coils shall be designed to maintain their nameplate KVA rating throughout the normal temperature range of operation which shall be 65*C (80°C hot spot). All materials used shall be of the 65°C, 800C hot spot class. All materials shall be thoroughly tested for compatibility with all transformer components before being assembled. C. The primary coil shall be manufactured from heavy varnish or paper insulated aluminum or copper wire. The secondary coil shall be manufactured from full width aluminum strip whose edges are finished to prevent burrs and insulated with epoxy -diamond paper between layers of the conductor. D. All insulating paper used as layer insulation in transformer coil shall be bonded type, coated on both sides with a thermosetting adhesive and properly cured prior to impregnating with oil or the coils shall be wound with primary conductor containing a thermosetting adhesive that when properly cured will form an effective bond, both turn to turn and layer to layer. 7of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 5.2. Insul,ating Fluid A. The transformer insulating fluid shall be standard electrical grade mineral insulating oil. The insulating oil shall be tested and degassed to assure a chemically inert oil. The transformers shall be furnished with oil which meets the requirements specified in ASTM Standard D 3487 for mineral insulating oil, except that the DBPC content (% by weight) shall not be less than 0.15. The insulating oil in the equipment shall conform with ANSI C57.106. B. All transformer oil shall be tested for polychlorinated biphenyl's (PCBs) per ASTM D4059 and certified as having no detectable levels of PCB. All oil furnished by supplier shall not contain any detectable traces of Polychlorinated biphenyls. C. A sealed tank shall be provided on all transformers 5.3 Taps rind Changers A. The transformers shall be furnished with full capacity high -voltage taps. The tap changer shall be externally operated and clearly labeled to reflect that the transformer must be de -energized before operating the tap changer as required in Section 3.3 of ANSI C57.12.26. Padlocking provisions shall be available for lever or hotstick operable handles. Tap changer operating mechanisms shall be permanently identified to show "De -energized Operation Only". Decals and stencils are not acceptable. The unit shall have one of the following tap configurations: Two - 2%z% taps above and below rated voltage such as the following: VOLTAGE FULL CAPACITY TAPS 16,340 17,200/16,770/15,910/15,480 7,200 7,560/7,380/7,020/6,840 B. The tap changer position indicating nameplate shall have numerals or letters that are clearly legible and of permanent quality. Decals and stencils are not acceptable. 8of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 5.4 Pressure Withstand and Pressure Relief A. An assembly shall be provided that is designed for pressure relief. The assembly shall remain effectively sealed for overloads and external secondary short circuits of the duration and magnitude allowed by industry standards, but shall relieve pressure at a minimum of 8 PSIG. Design should meet the requirement of the latest edition of the ANSI C57.12.20 paragraph 6.27 for relief of excessive pressure. B. The valve shall be of the indicating type with weatherproof cover, and equipped with a pull -ring for hook -stick operation. It shall have 1/4 inch NPT threads and be located on the tank wall above the oil level in either segment 2 or 4 as designed in ANSI C57.12.20, Table S2. The valve shall meet the following minimum operating characteristics: 1. Cracking Pressure: 10 PSIG 2. Re -seal: 5 PSIG 3. Flow Rates: 50 SCFM at 15 PSIG 100 SCFM at 50 PSIG C. The valve body and various parts of the device shall be corrosion resistant. Only the following pressure relief devices are acceptable: 1. Circle Seal Model No. P60-383 2. Qualitrol Model No. 202-032-01 or 202-33-01 3. Beta Model Nos. 1712K-1, -5, -6, or Model No 1750K-5. D. The required electrical clearances between pressure relief valve and live parts shall be maintained. 5.5 Tank Pressure Withstand A. Tank withstand should meet the latest edition of NEMA TR1, Part 2. B. Tank (bottom shall have a rolled edge and tank wall base which is three layers thick. 5.6 Tank Finish A. Tank covers shall have a slope of 15 degrees for moisture run-off and 100 kVA and below, shall have an insulated coating on the cover capable of withstanding 15kV at a 2000 volt/sec rate of rise, or equal, tested per ASTM D149 using 1/4" diameter electrodes, or equal. The results of design test to confirm this capability shall be submitted for approval. 9 of 19 CITY OF VERNON LIG14T AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS B. The tank coat will be a finish which can withstand a direct blow of 160 inch -pounds per ASTM D-2794-69 for units 100 kVA and below and meets or exceeds the following as set forth in ANSI C57.12.28: 1. Salt spray for 1000 hours 2. Humidity Test, 3. Abrasion resistance 4. Crosshatch adhesion 5.Oil resistance. C. The paint on all transformer tanks shall be grayish in color and conform to Munsell 5BG 7.0/04 with the following tolerances: 1. Hue: +/-12 (3G and 713) 2. Value: +/-0.2 3. Chroms: +/-0.2 5.7 Tank and Covers A. Transformers shall have bolted covers for all size transformers. One spare bolt per each transformer shall be provided and included in the bid. 5.7 Internal Lead Identification A. Internal secondary leads shall be identified with appropriate markings permanently embossed in the lead that correspond with lead markings on the nameplate. 5.8 Extemal Features A. Transformers shall be provided with cover mounted high voltage porcelain bushings with eyebolt terminals, low voltage porcelain bushings with eyebolt terminals and ANSI single position support lugs (hanger brackets) with nameplate on lower bracket. For all transformers rated above 167 kVA, no support brackets are required. 5.9 Weight and Dimensions A. The maximum weight for transformers 100 kVA and below shall be 1,400 lbs. B. All 250, 333, and 500 kVA single phase transformers shall be 'light weight' transformers. The weights and dimensions of the "lightweight" transformers shall not exceed the weights and dimensions specified below. 10 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS Rating (kVA) Weight (Ibs) Height Inches Widtfi Inches Depth Inches 250 2,500 72 41 38 333 2,800 72 41 38 500 3,300 72 50 42 5.11 Ground Provisions A. All transformers shall have a tank grounding provision. 5.12 High Voltage Bushings A. Transformer rated 15 kVA through 167 kVA shall be furnished with two cover -mounted bushings. High Voltage bushing terminals shall be in accordance with the latest edition of the ANSI Standard C57.12.20, paragraph 6.1.2.2. B. The cover -mounted bushings shall be of the 15kV insulation class for 7kV transformers and 17kV insulation class for 16kV transformers. The creepage distance of the bushings shall not be less than 15 inches. C. When the distance between live parts of cover -mounted bushings is less than 12 inches, the bushings shall be equipped with approved bird guards. Bird guards that are approved for use on overhead transformers are: MANUFACTURER MODEL NUMBER C:oltec Industries 703803-53 Porcelain Products 65001 throw h 65019 _ RTE 0704119b01 Kuhlman Electric 6210209902 assembly 6210208804 assemblv t t of t9 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 5.13 Internal High -Voltage Connections A. Each internal high -voltage lead shall be equipped with either a ring - tongue or a hook -type connector. Each connector shall be terminated on a fixed threaded stud, a fixed threaded bolt, or a non -removable threaded bolt, each having two nuts for holding and locking purposes. 1. Ring -tongued type: The ring -tongue terminals shall have mechanical and electrical properties so as to contain the high - voltage leads, without breaking, even under short-circuit conditions. Bumdy type YAV are typical of the type desired. 2. Hook type: Hook terminals shall meet the same physical requirements as specified above for ring -tongue terminals. In addition to the above, both changing and locking nuts shall be held captive to prevent their complete removal. AMP, Inc. Style No. 3 "Hook" terminals are typical of the type desired. 5.14 Name fates A. A stainless steel nameplate shall be attached with non -corrosive hardware to the inside of the low voltage compartment door. The nameplate shall not be installed on the rear of the low voltage compartment area. Diagrams and numbers shall be of the size and quality such that they can be read from outside the compartment. In addition to the nameplate requirements shown in ANSI/IEE C57.12.00- 1987, for nameplate A with total weight including oil shall be indicated. 5.15 MSDS A. The supplier shall be required to provide all applicable Material Safety Data Sheets with all transformer orders. 6.0 TESTS 6.1 General A. Transformer tests shall be performed as specified in ANSI Standard C57.12.00. These test reports shall be provided to the City prior to shipping. The City will not receive any transformers without the required test reports. B. Units shall comply with routine test requirements of ANSI and certified test reports shall be furnished. The vendor shall provide with returned bids all applicable documentation of compliance with ANSI design 12 of 19 CITY OF VERNON LIGkT AND POWER ' OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS tests. C. The following data shall be submitted with each transformer order. a. Guaranteed maximum no load (excitation) loss at rated voltage and 110% voltage in Watts. p b. Guaranteed maximum load loss in Watts at rated voltage and 110% voltage. c. Guaranteed maximum total loss in Watts at rated voltage and 'I 10% voltage. d. Exciting Current in percent at rated voltage and 110% rated voltage. e. Percent impedance on base voltage and at the maximum temperature rise. f. Efficiencies shall be provided at loading levels of 100%, 75%, 50%, and 25%. g. Regulation at rated load @ 80% and 100% Power Factor. h�. Two sets of outline drawings showing dimensions, weight, gallons of oil, gauge of steel in tank walls, cover, bottom, and cooling radiators and description of accessories. After order is awarded, the vendor shall submit FINAL drawings. i. Verification that the transformer design has passed the required short circuit criteria per Section 3.4 of these specifications. 7.0 OPERATING PERFORMANCE 7.1 General The Apparatus shall perform in accordance with the conditions set forth in this Specification. 13 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 8.0 BID EVALUATION 8.1 Total Ownership Cost The purchase price of transformers shall be evaluated by lowest total ownership cost. The formula to evaluate Total Owning Cost (TOC): TOC = C + $4.53/W (PNL in Watts) + $1.11W (PLL in Watts) Where TOC is the total ownership cost in dollars, C is the initial cost in dollars, PNL is the guaranteed maximum no-load loss in watts, and Pu is the guaranteed maximum load loss in watts For the determination of the award for the transformer order(s), City will consider all bids within 5% of the lowest Present Value Cost of Transformer to be economically equivalent. The City of Vernon realizes it is impossible to accurately predict economic conditions over the evaluation period of 30 year s. Reference Section 1, SCOPE, second paragraph of these specifications. 8.2 Deliver A delivery date of 16 weeks ARO or less is required. Failure to quote a delivery schedule within this period may disqualify the bid. 9.0 DOCUMENTATION 9.1 For Bid Evaluation Bidders shall fumish the following in their bid proposals: 1. Transformer unit price, F.O. B. Soto Yard. 2. Guaranteed maximum no-load loss at rated voltage in watts. 3. Guaranteed maximum load loss in watts at rated voltage and kVA. 4. Percent impedance on rated voltage tap. 5. Two sets of dimension and outline drawings. 14 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 9.2 For Delivery Supplier shall furnish MSDS and certified test reports and drawings, as listed in Section 11.1 in this Specification one month before transformers are shipped. - These documents shall be submitted to: City of Vernon Utilities Department 4305 Santa Fe Avenue Vernon Ca, 90058 Phone: (323) 583-8811 Attention: Jose Lugo Electrical Engineer 10. CONTRACT A. The vendor may be required to execute a purchase contract with City of Vernon, and may be required to furnish proof of insurance pursuant'to Attachment B, Insurance Schedule. If required, the vendor shall provide a letter from its insurance company that certifies the amounts of the insurance policy. The letter from the insurance company will be in substantially the same form as the SAMPLE INSURANCE FORM LETTER, which is also included in Attachment B. 11. SHIPMENT A. Supplier's quote shall be F.O.B. City of Vernon, Soto Yard located at 2800 Soto ,Avenue, Vernon Ca 90058. B. Transformers will be delivered on a flatbed track for side unloading by forklift at ground level. C. Supplier shall notify City 48 hours prior to delivery. All delivery shall be Monday -Friday, 7:30 AM to 3:00 PM. Contact telephone is (323) 589- 9498 or (323) 585-5192. D. 15 days prior to shipment, supplier shall furnish certified test reports of the switch. E. 15 days prior to shipment, supplier shall fumish three (3) sets of Operations/Instruction Manuals. 15 of 19 CITY OF VERNON LIGHT1AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 12. WARRANTY Supplier shall provide warranty for a minimum of twelve (12) months after delivery. 16 of 19 CITY OF VERNON LIGI4T AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS ATTACHMENT A Transformer Rmt;.,r.� 11�^A t-, +t,,, ., ITEM QUANTITY RATED VOLTS (PRIMARY VOLTS RATED VOLTS (SECONDARY VOLTS RATING (KVA) MATERIAL CODE 1 2 3 4 5 6 7 0 3 5 0 6 0 0 7200/12470Y 7200112470Y 7200/12470Y 7200112470Y 7200/12470Y 7200/12470Y 7200112470Y 120/240 1201240 120/240 120/240 120/240 120/240 120/240 15 25 37.5 50 75 100 167 001-0151 001-0251 001-0371 001-0501 001-0751 001-1001 001-1671 8 9 10 11 12 13 14 15 16 17 0 8 0 0 0 0 0 0 0 0 7200/12470Y 7200/12470Y 7200/12470Y 7200/12470Y 7200/12470Y 7200/12470Y 7200/12470Y 7200112470Y 7200/12470Y 7200/12470Y 2771480Y 277/480Y 777/480Y 277/480Y 277/480Y 277/480Y 277/480Y 277/480Y, 277/480Y 277/480Y 15 25 37.5 50 75 100 167 250 333 500 001-0152 001-0252 001-0372 001-0502 001-0752 001-1002 001-1672 001-2502 001-3332 001-5002 8 19 20 21 22 23 24 0 12 0 15 0 0 0 16340 16340 16340 16340 16340 16340 16340 120/240 120/240 120/240 120/240 120/240 120/240 120/240 15 25 37.5 50 75 100 167 002-0151 002-0251 002-0371 002-0501 002-0751 002-1001 002-1671 25 26 27 28 29 30 31 32 33 34 35 6 7 0 12 0 0 11 0 0 0 0 16340 16340 16340 16340 16340 16340 16340 16340 16340 16340 16340 2771480Y 277/480Y 2771480Y 277/480Y 2771480Y 277/480Y 277/480Y 2771480Y 2771480Y 277/480Y 2771480Y 10 15 25 37.5 50 75 100 167 250 333 500 002-0102 002-0152 002-0252 002-0372 002-0502 002-0752 002-1002 002-1672 002-2502 002-3332 002-5002 17 of 19 CITY OF VERNON LIGHfi AND'POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS ATTACHMENT B INSURANCE SCHEDULE (Vendor) The Contractor shall provide proof of insurance, including a standard certificate of insurance, in at least the following amounts and coverage (combined single limit permitted): Coverage and Limits Bodily ury Property Damage Hazards Each Person Each Accident Each Accident Automobile Liability Owned Automobiles $500,000 $1,000,000 $500,000 Hired Automobiles $500,000 $1,000,000 $500,000 Non -Owned Automobiles $500,000 $1,000,000 $500,000 Workers' Compensation $ Statutory Employers' Liability $1,000,000 per em to er II. General Liability Premises Operations $1,000,000 $2,000,000 $1,000,000 Elevators (if applicable) $1,000,000 $2,000,000 $1,000,000 Independent Contractors $1,000,000 $2,000,000 $1,000,000 Products — Completed $1,000,000 $2,000,000 $1,000,000 Operations Contract Liability$1,000,000 $2,000,000 $1,000,000 Umbrella Liabilit $4,000,000 $1,000,000 $1,000,000 The general liability policy shall contain the following special endorsements which shall be noted on or attached to the standard certificate of insurance: An endorsement naming City, its officers, and employees as insureds under the policy. An endorsement providing City thirty (30) days notice of cancellation or material reduction of coverage. An endorsement providing coverage for all operations under City permit and specifying the activities covered. Such other endorsement as may be required by addendum hereto. In addition to the standard certificate of insurance, proof of general and umbrella liability coverage shall be furnished in the form checked below. Certification of the following proofs by the insurance agent or broker will not be accepted: For each policy, a notarized letter from the underwriter or carrier certifying that the coverage and statements in the standard certificate of insurance (attached thereto) are true and correct and that the signator is an officer authorized to so certify. A copy of each policy certified by an officer of the underwriter or carrier and notarized. 18 of 19 SUPPORTING DOCUMENTS �1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16, 17111 18'I 19 20'' 21 221', 23 24 25 26 27 28 EQUIPMENT PURCHASE CONTRACT THIS AGREEMENT is made, entered into and executed in duplicate originals, either copy of which may be considered and used as the original hereof for all purposes, as of this day of February, 2004, in the City of Vernon, County of Los Angeles, California BY AND BETWEEN AND RECITALS THE CITY OF VERNON (hereinafter referred to as the "City") 4305 Santa Fe Avenue Vernon, CA 90058 WESCO DISTRIBUTION, INC. (hereinafter referred to as "WESCO") 10020 Freeman Avenue Santa Fe Springs, CA 90670 WHEREAS, on December 11, 2003, the City requested proposals or bids for 115 various one -phase, 60 Hz, mineral oil filled, overhead type distribution transformers (the "Transformers") (Bid No. 1432) needed by the City's Light and Power Department; and WHEREAS, the City is permitted to accept or reject any or all quotations received on the bid items; and WHEREAS, on or about January 8, 2004, the City received various proposals for the sale of the Transformers identified in Bid No. 1432, with each of the 115 bid items quoted separately; and WHEREAS, on January 5, 2004, WESCO, submitted a bid; and WHEREAS, on January 8, 2004, the City opened the bid submitted by WESCO, as well as other bids for the items identified in Bid No. 1432; and WHEREAS, the City desires to purchase the following bid E 1 items from WESCO: three (3) 25 KVA, 7.2 KV 120/240V Transformers; five 2 (5) 37.5 KVA, 7.2 KV 120/240V Transformers; six (6) 50 KVA, 7.2 KV 3 120/240 V Transformers; six (6) 75 KVA, 7.2 KV 120/240V Transformers; 4 eight (8) 25 KVA, 7.2 KV 277/480 Transformers; six (6) 50 KVA, 7.2 KV 5 277/480 Transformers; and three (3) 250 KVA, 7.2 KV 277/480 6 Transformers for a total of thirty-seven (37) Transformers per City of 7 Vernon Specification No. TR1-2003. 8 NOW, THEREFORE, THE PARTIES HERETO DO MUTUALLY AGREE AS SET 9 FORTH HEREIN: 10 1. Purchase. WESCO agrees to sell and deliver to the 11 City a total of thirty-seven (37) Transformers referenced above 12 pursuant to City of Vernon Specification No. TR1-2003, as identified 13 in WESCO's January 5, 2004 bid and which meet the specifications 14 contained in City of Vernon Bid No. 1432, dated December 11, 2003 15 (collectively referred to as the "Bid Documents"). A copy of the Bid 16 Documents are attached hereto as Exhibit "A" and incorporated herein 17 by reference. 18 2. Time of Performance. WESCO's performance shall 19 commence upon the full execution of this Contract and delivery of the 20 transformers and shall be completed by WESCO within 16 weeks after 21 receipt of order. 22 3. Price. The City agrees to purchase thirty-seven (37) 23 Transformers from WESCO for the total sum of Thirty -One Thousand Seven 24 Hundred Forty -Six Dollars and No Cents ($31,746.00). This price 25 includes freight and excludes sales tax. 26 4. Delivery. Consistent with the Bid Documents, WESCO 27 agrees to deliver the thirty-seven (37) Transformers on a flatbed 28 truck for side unloading by forklift at ground level to the City. -2- r1 WESCO shall notify the City 48-hours prior to delivery at (323) 589- y 2 9498 to make arrangements for gates to be opened. Delivery shall be 3 scheduled for Monday through Friday between the hours of 7:30 a.m. and 4 3 p.m. Prior to shipment, WESCO shall furnish certified test results 5 of the switch and three (3) seas of Operations/Instruction Manuals. 6 5. Warranties. WESCO warrants title to the Transformers 7 purchased hereunder and any part thereof to be free of any claim or 8 any security interest, lien or encumbrance. WESCO also warrants that 9 the Transformers will be delivered new and shall be free from defects. 10 WESCO shall provide, at a minimum, a one (1) year labor and material 11 warranty to begin upon acceptance of the Transformers by the City. 12 All manufacturers'' warranties, any warranties typically provided by 13 WESCO and any other warranties made applicable by law shall apply to 14 the City's purchase of the Transformers. 15 6. Governing Law. The validity, interpretation and 16 Performance of this Contract shall be controlled and construed under 17 the laws of the State of California. 18 7. Forum Selection. Any action brought relating to this 19 Contract shall be brought and held exclusively in a State Court in the 20 County of Los Angeles, California. 21 8. Notices. Notices to the parties, unless otherwise 22 requested in writing, shall be sent to: 23 City: THE CITY OF VERNON ATTN: DOLORES FONSECA 24 PURCHASING ASSISTANT 4305 SANTA FE AVENUE 25 VERNON, CA 90058-0805 26 WESCO: WESCO DISTRIBUTION, INC. ATTN: LESLIE MCCOY 27 BRANCH OPERATIONS MANAGER 10020 FREEMAN AVENUE 28 SANTA FE SPRINGS, CA 90670 -3- Y 1 9. Risk of Loss. Title and risk of loss or damage shall 2 pass to the City and delivery shall be deemed to be complete upon 3 delivery FOB jobsite or upon moving into storage at the City's 4 request, whichever occurs first. 5 10. Attorneys' Fees. In the event that it becomes 6 necessary for either party to this Agreement to enforce any of the 7 provisions of this Agreement, the parties agree that a court of 8 competent jurisdiction may determine and fix reasonable attorney's 9 fees to be paid to the successful litigant. 10 IN WITNESS WHEREOF, the parties have caused this Agreement 11 to be executed by and through their authorized officers on the date, 12 month and year first written above. 13 CITY OF VERNON 14 15 By. EONIS C. MALBU �,Mayr 16 ATTEST: 17 GX j 18 BRUCE V. MALKENHORST, City Clerk 19 APPROVED AS TO FORM: 20 21 ERIC T. FRESCH, City Attorney 22 WESCO DISTRIBUTION, INC. 23 By: 24 Title: frc A ;n1�a,Cr- 25 26 BY: i 27 Title: S-ArS 1, r-c"Tor 28 -4- REQUEST FOR QUOTATIONS NOT A PURCHASE ORDER D16ECTALL INQUIRIES TO: CITY PURCHASING AGENT TELEPHONE (323) 583-8811 CITY OF VERNON, CALIFORNIA PURCHASING DEPARTMENT CITY HALL . 4305 Santa Fe Ave. - Vernon, California 90058 ABB TO: Mr. Greg Tagliaferri c/o Wesco Distribution, Inc., 10020 Freeman Avenue Santa -Fe Springs, CA 90670 FOR CITY USE ONLY QUOTATION NO. 1432 DATE MAILED 12 03 REC'D BY CITY-bl ®O r Please quote hereon the lowest net price you can furnish the articles or services specified below. Quote on each item separately. Bidder may qualify quotations as "all or none" by stating so on body of form. City reserves the right to accept or reject quotations received on any or all items. In order to maintain their name on City's Bidder File, Vendor should return this form whether a price is quoted or not. QUANTITY DESCRIPTION NET UNIT PRICE TOTAL Overhead type distribution transformers, as per City of Vernon Light & Power Specification No. TR1-2003 dated November 19, 2003. t-3 25 KVA, 7.2 KV 120/240V73 Overhead Transformer 1-5 37.5 KVA, 7.2 KV, 120/240 V Overhead Transformer �V 4��W6 50 KVA, 7.2 KV, 120/240 V Overhead Transformer 7�% 00 �% �2' 6 75 KVA, 7.2 KV, 120/240 V Overhead Transformer . -- 8 25 KVA, 7.2 KV, 277/480 Y Overhead Transformer /-700 00 4 7oltO � ra-6 50 KVA, 7.2 KV, 277/480 Y Overhead Transformer -7357 a° 4ygff -3 250 KVA, 7.2 KV, 277/480 Y Overhead Transformer �c -7'77 -----------PLEASE NOTE ---- ---- Bid number must be indicated on the outside of the envelope; otherwise, bid will not be accepted. IF INSUFFICIENT SPACE PROVIDED ABOVE FOR PROPOSAL, ATTACH RIDER OR SUPPLEMENT. CASH DISCOUNTS QUOTED FOR PERIODS OF LESS THAN 30 DAYS WILL NOT BE CONSIDERED WHEN ORDER IS AWARDED. BIDS RECEIVED IN RESPONSE TO THIS REQUEST FOR QUOTATION WILL BE OPENER CITY PURTA]�1 AGENTS G 8th January : � OFFICE ON THE DAYoF 20 AT V NOTE: Quote prices exclusive of Sales Tax and Excise T�fe . A. Indicate Sales Tax in this space $.....S?,.. 71..`...(.�.i......................................B. Indicate Excise Tax in this space $ ..................................................... B. Above quotations subject to Cash Discount qf...... ti. r �^ ..,.... . %, FO.B... �e'.1AV.�:�GJ... L{ ! ... ....i i +l�we:�e ilPXilo ................................................ C. To be delivered to CITY OF VERNON at....... r........................................... .......... ............................................................. r............ We (1) agree to furnish above in .........................................days from receipt of purchase order at prices specified ` FOR.............................. ., ....4�%P ................................... TFi Name j DATE ........... Y ............................ SIGN HERE ........ ' .-...`.J. .............!—c:x.4............. 4.G.I......... MAIL TO PURCHASING DEPT. 12/02 REQUEST FOR QUOTATIONS NOT A PURCHASE ORDER DIRECTALL INOUIRIESTO: CITY PURCHASING AGENT TELEPHONE (323) 583-8811 TO: CITY OF VERNON, CALIFORNIA PURCHASING DEPARTMENT CITY HALL 4305 Santa Fe Ave. - Vernon, California 90058 FOR CITY USE ONLY QUOTATION NO. DATE MAILED REC'D BY CITY OPENED BY Please quote hereon the lowest net price you can furnish the articles or services specified below. Quote on each item separately. Bidder may qualify quotations as "all or none" by stating so on body of form. City reserves the right to accept or reject quotations received on any or all items. In order to maintain their name on City's Bidder File, Vendor should return this form whether a price is quoted or not. QUANTITY DESCRIPTION NET UNIT PRICE TOTAL f 12 25 KVA 16.34 KV 1(JLJ CID 120/240 V Overhead Transformer 21 50 KVA, 16.34 V, 120/240 V Overhead Transformer " 3 167 KVA, 16.34 V, �a �p& 120/240 V Overhead Transformer 6 10 KVA, 16.34 KV,� 277/480 Y Overhead Transformer 4333 co7 15 KVA, 16.34 KV, I'p(q � 277/480 Y Overhead Transformer 12 37.5 KVA, 16.34 KV, on � 2 8� 277/480 Y Overhead Transformer 6 50 KVA, 16.34 KV �? 277/480 Y Overhead Transformer 11 100 KVA, 16.34 KV, l-� 7 /(o 277/480 Y Overhead Transformer ----PLEASE NOTE ---------- Bid number must be indicated on the outside of the envelope; otherwise, bid will not be accepted. IF INSUFFICIENT SPACE PROVIDED ABOVE FOR PROPOSAL, ATTACH RIDER OR SUPPLEMENT. CASH DISCOUNTS QUOTED FOR PERIODS OF LESS THAN 30 DAYS WILL NOT BE CONSIDERED WHEN ORDER IS AWARDED. BIDS RECEIVED IN RESPONSE TO THIS REQUEST FOR QUOTATION WILL BE OPENED IN CITY PURCHASING AGENTS OFFICE ON THE DAY OF 20 AT NOTE: Quote prices exclusive of Sales Tax and Excise Taxes. A. Indicate Sales Tax in this space $....................................................................B. Indicate Excise Tax in this space $ ..................................................... B. Above quotations subject to Cash Discount of .................................................%, F.O.B ................................................................................................. C. To be delivered to CITY OF VERNON at......................................................................................................................................................................... we (1) agree to fumish above in .........................................days from receipt of purchase order at, specified. FOR ................ S �? �D.-........................................ ........... Firma Name DATE............ SIGN HERE....................................................�cy ..................................................... .�D. i { LCs , re� ,ins ,vo2 MAIL TO PURCHASING DEPT. 9 r a� c �, o P J REQUEST FOR AUOTATIONS NOT A PURCHASE ORDER DIRECT ALL INQUIRIES TO: CITY PURCHASING AGENT TELEPHONE (323) 583-Ul l ro: CITY OF VERNON, CALIFORNIA PURCHASING DEPARTMENT CITY HALL 4305 Santa Fe Ave. - Vernon, California 90058 FOR crrY USE ONLY QUOTATION NO. DATE MAILED REC'D BY CITY OPENED BY Please quote hereon the lowest net price you can furnish the articles or services specified below. Quote on each item separately. Bidder may qualify quotations as "all or none" by stating so on body of form. City reserves the right to accept or reject quotations received on any or all items. In order to maintain their name on City's Bidder File, Vendor should return this form whether a price is quoted or not. QUANTITY DESCRIPTION NET UNIT PRICE TOTAL If you have any questions regarding the bid or the attached specifications, please call Jose Lugo (Electrical Engineer) at (323) 583-8811, ext. 276. ------------PLEASE NOTE ---------- Bid number must be indicated on the outside of the envelope; otherwise, bid Will not be accepted. IF INSUFFICIENT SPACE PROVIDED ABOVE FOR PROPOSAL, ATTACH RIDER OR SUPPLEMENT. CASH DISCOUNTS QUOTED FOR PERIODS OF LESS THAN 30 DAYS WILL NOT BE CONSIDERED WHEN ORDER IS AWARDED. BIDS RECEIVED IN RESPONSE TO THIS REQUEST FOR QUOTATION WILL BE OPENED IN CITY PURCHASING AGENTS OFFICE ON THE DAY OF 20 AT VOTE: Quote prices exclusive of Sales Tax and Excise Taxes. A. Indicate Sales Tax in this space$....................................................................B. Indicate Excise Tax in this space $ ..................................................... B. Above quotations subject to Cash Discount of .................................................%, F.O.B ................................................................................................. C. To be delivered to CITY OF VERNON at......................................................................................................................................................................... We (1) agree to furnish above in .........................................days from receipt of purchase order at pric T. s flied. FOR ..................... CSCi4?... 45TCt .tio^.... . C�.:......................I.............. Firm Name ` )ATE.........` ..`... .............................. SIGN HERE ..... ............. .y......... si.t �.s.....f fi. ................ MAIL TO PURCHASING DEFT. 10 r, Or ° � ��nr (� y 12-23-2003 i To: LISA GROVES WESCO SANTA FE SPRINGS ` LISA RE YOUR REQUEST FOR BELOW CUSTOMER DTD 12/12 ATHENS QUOTES AS FOLLOWS, PRICES FIRM IN TRUCKLOAD RELEASES THRU 12/31/04. REF ATHENS NEG NO: SF121631 City of Vernon Contract Effective Date: 12/23/2003 Contract Expiration Date: 12/31 /2004 PLS QUOTE: Shipment Period: 0 1/0 1/2001-06/30/2001 ITEM QTY PRODUCT ID 1 3 A7312W25ZZM1631 CustProduct-ID: 001-0251 Overhead Distribution Transformer; S - Conventional 25 KVA No Load: 50 Watts at 85 degrees C; Load: 362 Watts at 85 degrees C; Total Loss: 412 Watts 7200/12470Y HV; 95 BIL; Copper HV Winding Matl With Taps at 7560, 7380, 7020, 6840 120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mall 60 Hz 1 Phase Transformer Weight: 352.13 lbs.; Height: 39 in.; Width: 20.00 in.; Depth: 24.00 in. Est. Shipping Dimensions: 366.13 lbs. Height: 43 in.; Width: 24 in.; Length: 25 in.; Est. C/C Weight: 191.8 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt 3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain 13.3 Gal(s) of Transformer Oil 1 15.25" Carbon STL Cover, 2 HV Bushing Holes 2 5 A7312W37ZZM1631 CustProduct-ID: 001-03 71 Overhead Distribution Transformer; S - Conventional 37.5 KVA No Load: 85 Watts at 85 degrees C; Load: 420 Watts at 85 degrees C; Total Loss: 505 Watts 7200/12470Y HV; 95 BIL; Copper HV Winding Matl With Taps at 7560, 7380, 7020, 6840 120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl 60 Hz ha 1 Phase Transformer Weight: 466.99 lbs.; Height: 39 in.; Width: 22.00 in.; Depth: 27.00 in. Est. Shipping Dimensions: 487.99 lbs. Height: 43 in.; Width: 26 in.; Length: 26 in.; Est. C/C Weight: 262.35 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt 3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain 17.4 Gal(s) of Transformer Oil 1 17.5" Carbon STL Cover, 2 HV Bushing Holes ti 3 6 A7312W50Z2M1631 CustProduct-ID: 001-0501 Overhead Distribution Transformer; S - Conventional 50 KVA No Load: 86 Watts at 85 degrees C; Load: 605 Watts at 85 degrees C; Total Loss: 691 Watts 7200/12470Y HV; 9YBIL; Copper HV Winding Mad With Taps at 7560, 7380, 7020, 6840 120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl 60 Hz 1 Phase ,✓ Transformer Weight: 592.851bs.; Height: 48 in.; Width: 22.00 in.; Depth: 27.00 in. Est. Shipping Dimensions: 613.85 lbs. Height: 52 in.; Width: 26 in.; Length: 26 in.; Est. C/C Weight: 306.44 lbs. 65 Temp. Rise; I HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt 3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain 25.8 Gal(s) of Transformer Oil 1 17.5" Carbon STL Cover, 2 HV Bushing Holes 4 6 - A7312W75ZZM1631 CustProduct-ID: 001-0751 Overhead Distribution Transformer; S - Conventional 75 KVA No Load: 144 Watts W degrees C; Load: 778 Watts at 85 degrees C; Total Loss: 922 Watts 7200/12470Y HV; 95 BIL; Copper HV Winding Matl With Taps at 7560, 7380, 7020, 6840 120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl 60 Hz 1 Phase Transformer Weight: 840.98 lbs.; Height: 52 in.; Width: 25.00 in.; Depth: 31.00 in. Est. Shipping Dimensions: 872.98 lbs. Height: 56 in.; Width: 32 in.; Length: 33 in.; Est. C/C Weight: 412.261bs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt 3 LV Bushings, Eye Bolt for #I-500MCK Porcelain 39 Gal(s) of Transformer Oil 1 20" Carbon STL Cover, 2 HV Bushing Holes 8 A7352W25ZZM1631 CustProduct-ID: 001-0252 Overhead Distribution Transformer; S - Conventional 25 KVA No Load: 51 Watts at.Z degrees C; Load: 341 Watts at 85 degrees C; Total Loss: 392 Watts 7200/12470Y HV; 95 BIL; Aluminum HV Winding Mad With Taps at 7560, 7380, 7020, 6840 277/480Y LV; 30 BIL.; Non-LV Interlaced; Aluminum LV Winding Matl 60 Ih 1 Phase Transformer Weight: 401.791bs.; Height: 39 in.; Width: 22.00 in.; Depth: 26.00 in. Est. Shipping Dimensions: 422.79 lbs. Height: 43 in.; Width: 26 in.; Length: 26 in.; Est. C/C Weight: 198.42 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt 2 LV Bushings, Eye Bolt for #6-4/0, Porcelain 17.9 Gal(s) of Transformer Oil 1 17.5" Carbon STL Cover, 2 HV Bushing Holes 6 6 A7352W50ZZM1631 CustProduct-ID: 001-0502 Overhead Distribution Transformer; S - Conventional 50 KVA No Load: 88 Watts a85 degrees C; Load: 557 Watts at 85 degrees C; Total Loss: 645 Watts 7200/12470Y HV; 95 BIL; Copper HV Winding Mad With Taps at 7560, 7380, 7020, 6840 277/480Y LV; 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mad 60 Hz 1 Phase Transformer Weight: 561.96 lbs.; Height: 44 in.; Width: 22.00 in.; Depth: 26.00 in. Est. Shipping Dimensions: 582.96 lbs. Height: 48 in.; Width: 26 in.; Length: 26 in.; Est. C/C Weight: 315.26 lbs. 65 Temp. Rise;. 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, oversize 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, oversize 17.75"Creep, 8-2 size eyebolt 2 LV Bushings, Eye Bolt for #2-350MCM, Porcelain 21.4 Gal(s) of Transformer Oil 1 17.5" Carbon STL Cover, 2 HV Bushing Holes 7 3 A7352W52ZZM1631 CustProduct-ID: 001-2502 Overhead Distribution Transformer; S - Conventional 250 KVA No Load: 299 Wattkat 85 degrees C; Load: 1998 Watts at 85 degrees C; Total Loss: 2297 Watts 7200/12470Y HV; 95 BIL With Taps at 7560, 7380, 7020, 6840 277/480Y LV; 30 BIL; Non-LV Interlaced 60 Hz 1 Phase f Transformer Weight: 1744.77 lbs.; Height: 57 in.; Width: 39.00 in.; Depth: 33.00 in. Est. Shipping Dimensions: 1817.77 lbs. Height: 61 in.; Width: 30 in.; Length: 30 in.; Est. C/C Weight: 919.3 lbs. 65 Temp. Rise; I HV Tap Chgr, ABB, Ext (lever) setscrew lockable handle, 5 Po 1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt. 2 LV Bushings, 4 Hole "H" spade, Porcelain V STUD 65 Gal(s) of Transformer Oil 1 24" Carbon STL Cover, 2 HV Bushing Holes 12 A1612W25ZZM1631 CustProduet-ID: 002-0251 Overhead Distribution Transformer; S - Conventional 25 KVA No Load: 57 Watts at 85 degrees C; Load: 323 Watts at 85 degrees C; Total Loss: 380 Watts 16340 95 L; Aluminum HV Winding Mat] With Taps 200, 16770, 15910, 15480 120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl 60 Hz 1 Phase Transformer Weight: 404.9 lbs.; Height: 38 in.; Width: 22.00 in.; Depth: 27.00 in. Est. Shipping Dimensions: 425.9 lbs. Height: 42 in.; Width: 26 in.; Length: 26 in.; Est. C/C Weight: 202.83 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain 17.6 Gal(s) of Transformer Oil 1 17.5" Carbon STL Cover, 2 HV Bushing, oless 9 21 A1612WSOZZM1631 CustProduct-ID: 002-050 Overhead Distribute ransformer; S - Conventional 50 KVA No Load: �W at 85 degrees C; Load: 620 Watts at 85 degrees C; Total Loss: 706 Watts 16340 HV, 95 B ; Copper HV Winding Matl With Taps 17 , 16770, 15910, 15480 120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl 60 Hz 1 Phase Transformer Weight: 59N lbs.; Height: 48 in.; Width: 22.00 in.; Depth: 27.00 in. Est. Shipping Dimensions: 614.6 lbs. Height: 52 in.; Width: 26 in.; Length: 26 in.; Est. C/C Weight: 308.65 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 3 LV Bushings, Eye Bolt for #2-350MCM, Porcelain 25.6 Gal(s) of Transformer Oil 1 17.5" Carbon STL Cover, 2 HV Bushing Holes 10 3 A1612W67ZZM1631 CustProduct-ID:002-1671 Overhead Distribution Transformer; S - Conventional 167 KVA No Load: 2 Wittts at 85 degrees C; Load: 1616 Watts at 85 degrees C; Total Loss: 1841 Watts 16340 HV; 5 B ; Aluminum HV Winding Matl With Taps 41.7200, 16770, 15910, 15480 120/240 LV; 30 * 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mat] 60 Hz 1 Phase Transformer Weight: 1379.96 lbs.; Height: 48 in.; Width: 39.00 in.; Depth: 37.00 in. Est. Shipping Dimensions: 1452.86 lbs. Height: 52 in.; Width: 38 in.; Length: 44 in.; Est. C/C Weight: 718.71 lbs. 65 Temp. Rise; i HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 4 LV Bushings, 4 Hole "H" spade, Porcelain 1" STUD 50 Gal(s) of Transformer Oil 1 24" Carbon STL Cover, 2 HV Bushing Holes. 11 6 A1652WIOZZM1631 CustProduct-ID: 002-0102 Overhead Distribution Tr e; S - Conventional 10 KVA No Load: 23 W, at 85 degrees C; Load: 153 Watts at 85 degrees C; Total Loss: 176 Watts 16340 HVj495 L; Copper HV Winding Mad With Taps i{t 17200, 16770, 15910, 15480 277/480Y LV; 30 BIL; Non-LV Interlaced; Copper LV Winding Mad 60 Hz 1 Phase Transformer Weight: 257.22 lbs.; Height: 36 in.; Width: 18.00 in.; Depth: 22.00 in. Est. Shipping Dimensions: 268.22 lbs. Height: 40 in.; Width: 22 in.; Length: 23 in.; Est. C/C Weight:.138.89 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt I HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 2 LV Bushings, Eye Bolt for #64/0, Porcelain 9.4 Gal(s) of Transformer Oil 1 13.25" Carbon STL Cover, 2 HV Bushing Holes 12 7 A1652W15ZZM1631 CustProduct-ID:002-0152 Overhead Distribution Transformer; S.- Conventional 15 KVA , No Load: F f r, at 85 degrees C; Load: 186 Watts at 85 degrees C; Total Loss: 217 Watts 16340 HV With Taps0, 16770, 15910, 15480 277/480Y LV; 30 BIL; Non-LV Interlaced 60 Hz 1 Phase Transformer Weight: 344.28 lbs.; Height: 36 in.; Width: 20.00 in.; Depth: 24.00 in. Est. Shipping Dimensions: 358.281bs. Height: 40 in.; Width: 24 in.; Length: 25 in.; Est. C/C Weight: 194 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 2 LV Bushings, Eye Bolt for #64/0, Porcelain 12.3 Gal(s) of Transformer Oil 1 15.25" Carbon STL Cover, 2 HV Bushing Holes 13 12 A1652W37ZZM1631 CustProduct-ID:002-0372 Overhead Distribution Transformer; S - Conventional 37.5 KVA No Load: $3"Watts at 85 degrees C; Load: 430 Watts at 85 degrees C; Total Loss: 513 Watts 16340 95 ; Copper HV Winding Mad With Taps t 200, 16770, 15910, 15480 277/480Y LV; 30 BIL; Non-LV Interlaced; Aluminum LV Winding Mad 60 Hz 1 Phase Transformer Weight: 464.63 lbs.; Height: 38 in.; Width: 22.00 in.; Depth: 26.00 in. Est. Shipping Dimensions: 485.631bs. Height: 42 in.; Width: 26 in.; Length: 26 in.; 14 6 15 11 Est. C/C Weight: 260.15 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 2 LV Bushings, Eye Bolt for 42-350MCM, Porcelain 17.4 Gal(s) of Transformer Oil 1 17.5" Carbon STL Cover, 2 HV Bushing Holes A1652W50ZZM1631 CustProduct-ID:002-05 Overhead Distrib " ransformer; S - Conventional 50 KVA* No Load;,�Watts at 85 degrees C; Load: 543 Watts at 85 degrees C; Total Loss: 638 Watts 16340 HV 95 BIL; Copper HV Winding Matl With T at 17200, 16770,15910, 15480 Y LV; 30 BIL; Non-LV Interlaced; Aluminum LV Winding Matl 60 Hz 1 Phase Transformer Weight: 563.57 lbs.; Height: 44 in.; Width: 22.00 in.; Depth: 26.00 in. Est. Shipping Dimensions: 584.57 lbs. Height: 48 in.; Width: 26 in.; Length: 26 in.; Est. C/C Weight: 315.3 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 1 HV Neut Bushing, 125kV BEL, 17.75"Creep, 8-2 size eyebolt 2 LV Bushings, Eye Bolt for #2-350MCM, Porcelain 21.6 Gal(s) of Transformer Oil 1 17.5" Carbon STL Cover, 2 HV Bushing Holes A1652W99ZZM1631 CustProduct-ID:002-1002 F Overhead Distribution T*sformer; S - Conventional 100 KVA No Load: 17T at 85 degrees C; Load: 818 Watts at 85 degrees C; TotaI Loss: 993 Watts 16340 HV 95 B , Copper HV Winding Matl With Taps 17 , 16770, 15910, 15480 277/480Y L 0 BIL; Non-LV Interlaced, Aluminum LV Winding Mat] 60 Hz 1 Phase Transformer Weight: 1088.11 lbs.; Height: 52 in.; Width: 27.00 in.; Depth: 33.00 in. Est. Shipping Dimensions: 1152.11 lbs. Height: 56 in.; Width: 36 in.; Length: 40 in.; Est. C/C Weight: 557.77 lbs. 65 Temp. Rise; 1 HV TC, ABB, Ext (lever) setscrew lockable handle, 5 Pos, No. 1 HV Line Bushing, 125kV BIL, 17.75"Creep; 8-2 size eyebolt 1 HV Neut Bushing, 125kV BIL, 17.75"Creep, 8-2 size eyebolt 2 LV Bushings, Double Eye Bolt for 2/0-1000MCK Porcelain 48 Gal(s) of Transformer Oil 1 22" Carbon STL Cover, 2 HV Bushing Holes Item R X Imp Iexc RegPF* Reg 1 1.45 1.87 2.37 0.52 0.80 2.29 2 1.12 1.93 2.23 0.73 0.80 2.06 Reg@ Reg@ Effi'U* Eff Eff@ Eff@ .80 PF 1.0 PF 50%PU 100%PU 2.29 1.47 100.00 98.38 98.89 98.38 2.06 1.14 100.00 98.67 99.00 98.67 3 1.21 1.87 2.23 0.45 0.80 2.09 2.09 1.23 100.00 98.64 99.06 98.64 4 1.04 1.98 2.24 0.59 0.80 2.03 2.03 1.06 100.00 98.79 99.11 98.79 5 1.36 1.92 2.27 0.46 0.80 2.18 2.18 1.38 100.00 98.46 98.92 98.46 6 1.11 1.94 2.24 0.47 0.80 2.06 2.06 1.13 100.00 98.73 99.10 98.73 7 0.80 2.81 2.92 0.43 010 2.34 2.34 0.84 100.00 99.09 99.37 99.09 8 1.29 1.87 2.27 0.54 0.80 2.16 2.16 1.31 100.00 98.50 98.91 98.50 9 1.24 2.00 2.35 0.45 0.80 2.19 2.19 1.26 100.00 98.61 99.05 98.61 10 0.97 2.62 2.79 0.34 0.80 2.36 2.36 1.00 100.00 98.91 99.25 98.91 11 1.53 1.64 2.24 0.49 0.80 2.21 2.21 1.54 100.00 98.27 98.79 98.27 12 1.24 1.85 2.23 0.43 0.80 2.11 2.11 1.26 100.00 98.57 98.98 98.57 13 1.15 1.92 2.24 0.67 0.80 2.08 2.08 1.17 100.00 98.65 98.99 98.65 14 1.09 1.95 2.23 0.56 0.80 2.04 2.04 1.10 100.00 98.74 99.09 98.74 15 0.82 2.09 2.24 0.60 0.80 1.91 1.91 0.84 100.00 99.02 99.25 99.02 (*)From Customer Specifications Item Eff@ Eff@ Eff@ Eff@ Eff@ Reg@ Reg@ Reg@ NL@ NL@ EXI@ EXI@ 25% 50% 75% 100% 125% .8PF .9PF LOPF 105% 110% 105% 110% 1 98.85 98.89 98.67 98.38 98.07 2.29 2.13 1.47 59.00 70.00 0.72 1.18 2 98.83 99.00 98.87 98.67 98.44 2.06 1.86 1.14 103.00 127.00 1.31 3.12 3 99.02 99.06 98.88 98.64 98.38 2.09 1.91 1.23 101.00 121.00 0.65 1.09 4 98.98 99.11 98.98 98.79 98.57 2.03 1.81 1.06 174.00 214.00 1.03 2.39 5 98.86 98.92 98.72 98.46 98.17 2.18 2.02 1.38 58.00 67.00 0.56 0.72 6 99.03 99.10 98.94 98.73 98.49 2.06 1.86 1.13 104.00 125.00 0.68 1.19 7 99.33 99.37 99.25 99.09 98.92 2.34 1.97 0.84 365.00 453.00 0.80 2.20 8 98.78 98.91 98.74 98.50 98.23 2.16 1.98 1.31 66.00 77.00 0.70 1.02 9 99.01 99.05 98.85 98.61 98.34 2.19 1.99 1.26 101.00 121.00 0.65 1.09 10 99.23 99.25 99.10 98.91 98.70 2.36 2.03 1.00 264.00 314.00 0.47 0.77 11 98.71 98.79 98.57 98.27 97.95 2.21 2.09 1.54 26.00 28.00 0.56 0.64 12 98.88 98.98 98.81 98.57 98.31 2.11 1.93 1.26 34.00 38.00 0.50 0.60 13 98.84 98.99 98.86 98.65 98.42 2.08 1.88 1.17 100.00 122.00 1.12 2.46 14 98.98 99.09 98.94 98.74 98.51 2.04 1.83 1.10 114.00 139.00 0.90 1.80 15 99.10 99.25 99.16 99.02 98.85 1.91 1.66 0.84 213.00 265.00 1.15 3.03 EXCEPTIONS TAKEN TO CUSTOMER SPEC TR1-2003 Dated 11/19/2003 WE TAKE EXCEPTION TO PARA. 5.14 IN THAT WE FURNISH AN ANODIZED ALUMINUM NAMEPLATE INSTEAD OF A STAINLESS STEEL NAMEPLATE. NOTES PLEASE PUT DMSION NEGOTIATION NUMBER, DIVISION NEGOTIATION ITEM NUMBER AND COMPLETE 10 TO 15 CHARACTER STYLE NUMBER ON THE ORDER AT THE TIME OF ORDER ENTRY. IF THIS INFORMATION IS NOT COMPLETE AND CORRECT, ORDER IS SUBJECT TO CANCELLATION. "MODIFICATIONS TO THE QUOTED BILL OF MATERIAL MUST BE REVIEWED WITH ATHENS SALES ENGINEER PRIOR TO ORDER ENTRY." OVERHEAD TRANSFORMER LEAD TIMES FOR ITEMS NOT IN STOCK OR PRODUCTION ARE PER THE CHART BELOW. THESE LEAD T M ES DO NOT INCLUDE THE TIME NECESSARY FOR THE DESIGN OR ACQUISITION OF SPECIAL OR BOUGHT -OUTSIDE PARTS. ALL LEAD TIMES ARE FROM DATE OF ORDER ENTRY AT ATHENS TO DATE OF SHIPMENT & ARE SUBJECT TO AVAILABLE PRODUCTION SPACE AT ORDER ENTRY. CONTACT DIVISION SALES ENGINEER FOR AVAILABILITY AND PRICE ADJUSTMENT FOR SHORTER LEAD TIME. YOU MUST ENTER A COMPLETE 10 CHARACTER OR 15 CHARACTER STYLE NUMBER AT TIME OF ORDER ENTRY. KVA WEEKS COREFORM 5 - 37.5 KVA 6 - 7 STYLES THAT BEGIN WITH K, L, M, & N SHELL FORM 5 - 75 KVA 6 - 7 ALL OTHER STYLES LARGE 100-1000 KVA 7-8 JUMBOS 7-8 3 PHASE 8 LEAD TIME SUBJECT TO AVAILABLE SPACE ARO NO LOAD LOSSES QUOTED ARE GUARANTEED AVERAGES AT 85 DEGREES CENTIGRADE. OUR NAMEPLATE IS ENGRAVED AS FOLLOWS: "FILLED WITH MINERAL OIL THAT CONTAINED LESS THAN 1 P.P.M. P.C.B. AT TIME OF MANUFACTURE". GENERAL TERMS AND CONDITIONS OF SALE, PPIGTC073003 APPLY GBent& 19051 • v ACORD- CERTIFICATE OF LIABILITY INSURANCE Q;TE,MMIV ;°"""r' PRODUCER The HDH GrotgX Inc, P&C THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE USX Tower, Suite 1100 HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR 600 Grant Street ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. Pittsburgh, PA 15219-2804 INSURERS AFFORDING COVERAGE NAIC S INSaX:re WESCO Mtemational, Inc. XNSLIRERA: Travelers of NNn 25674 INSURER B: Travelers Co. of ConnscNc 25682 Few StMhSquare, Commeroe Ct #700 1uRER c: American GUaraMee & LhM!Ny Ins. M47 Pittsbtrglt, PA 15219 INSLm o INSURER e. vvV THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICES, AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. TYPE OF INSURANCE POLICY NUMBERmsom LIM" A ORAL LIAI MM CONRWRCIALGENERALUU3ILITY CLAIMS MADE nXX OCCUR TC2JGLSA466K204ATI 06104/03 06104104 EACH OCCURRENCE i 11mORE ED MED EXP ( *. Too t PERSONAL & ADV INJURY GENERALAGGREGATE AOOO.000 GEWL AGGREGATE LIMIT APPLIES PER: POLICY M j LOC PRODUCTS - COWIOP AM j&0oo 000 A B AUTOMOBILE UAGIVIT ANYAUTO ALL OWNED AUTOS SCHEDULED AUTOS W4m AUTOS Nc�rNowNEDAums MM Dam TC2JCAP466K2O26TIL TC2ECAP466K2038TCT 06104/03 06/04103 06104104 O6I04104 i S LIMIT $2,000.000 X tPorp-* Y $ X t BODILY INJURY $ X X t $ Self Mswed G GARk6B LMBILM ANYAUTO EXCE&$NNBRELLA LIA9LIrf OCCUR O❑ CLAIMS MADE OEDUCTISLE X RETENTION so AUC374484303 06IM3 OW04104 AUTO ONLY - EA ACCIDENT OTHER THAN EAAGC AUTOONLY% AGO EACH OCCURRENCE S '$ ,GATE A2m2m A A wommm coMPElmTm AND N3AM OVER ETORLTTY ANYPROPWETORIPARTNERlEXEC1JTME EXCLUDED? E!°M TC2JUB466K197003 TRJUB466K196203 06/04/O3 OW04003 11B104fO4 OWO4fO4 X AT1J E.L. EACH ACCIDENT S1000. 0� E.L. DISEASE - EA EMPLOY „L,� 1 tlOOL04Q EA DISE/15E - POLCY UhNT 1 000 OTHER DESCRIPTION OF OPERATX M J LOCATIONS f VEHICLES f EXCLUSIONS ADDED BY 040ORSENIENTI SPECMU. PROVISIONS WESCO Damon, MN:- S WESCO International, Inc. S any organization, other than a pwfimrship orlofnt venture, over which WESCO maintains ownership or majority Mutest on the effective date of Due Polley. At the tMw WESCO Is awarded the job for the City of Vernon. the City. Its (See Attached Descriptions) City of Vernon (City) 4305 Santa Fe Avenue Los Angeles, CA 90058 LO ANY OF IN G ABOVE DESCRIBED POLICIES BE "HELLO BEFORE THE EXMRATM TFEREOF, THE ISSUM INSISTER wu ENDEAVOR TO MAIL _.39 DAYS WRITTEN tE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, OUT FAILURE TO DO SO ft" M NO ORUeAMON OR LIANUTY OF ANY NNW UPON THE INSURER ITS AGENTS OR ^""^'""Kvugive) 7 Of 3 M71681M77065 LFO 6 ACORD CORPORATION IM IMPORTANT If the certificate holder is an ADDITIONAL INSURED, the poiicy(ies) must be endorsed. A statement on this certificate does not corder rights to the certificate holder in Neu of such endorsement(s). If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may retake an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). DISCLAIMER The Certitfcate of insurance on the reverse side of this form does not constitute a contract between the issuing insurer(s), authorized representative or producer, and the certificate hokler, nor does it affkmativefy or negatively amend, extend or alter the coverage afforded by the policies Rated thereon, cannon �c � nu.n..nw. SPECIFICATION NO. TR1-2003 OVERHEAD DISTRIBUTION TRANSFORMERS CITY OF VERNON LIGHT AND POWER November 19, 2003 SPECIFICATION NO. TR1-2003 Approved Manufacturers/Suppliers 1. Cooper Power c/o Mark Christensen Utility Products 44-909 Golf Center Pkwy, Suite #12 Indio, CA 92201 Phone: (760) 863-1660 2. ABB Inc. Attn: Jeff Vivian 2945 Harding Street, Suite 207 Carlsbad, CA 92008 Phone: (760) 720-3156 3. Howard Transformers c/o Young and Company 530 South Marengo Ave Pasadena, CA 91101 Phone: (626) 795-9955 4. General Electric Company c/o Southwest Power 9837 Pioneer Blvd. Santa Fe Springs, CA 90670 Phone: (562)801-4577 5. Central Moloney c/o Southcoast Utility Sales 8762 Luss Drive Huntington Beach, Ca 92646 (Phone): (714) 962-0841 Fax: 714-963-2487 6. Kuhlman Electric Corp. 101 Kuhlman Road Versailles, KY 40383 (Phone): (800) 395-6932 Fay- R-Q-R7q-Qn47 Prepared by; Approved by Kenneth DeDario, P.E. Director of Light and Power CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 1.0 SCOPE Supplier shall furnish all work for providing one -phase, 60 Hz, mineral oil filled, overhead type distribution transformers rated 500 kVA and below for use on the City of Vernon's overhead distribution system. The transformer sizes that the City requires are listed in Attachment A. This list does not preclude the possibility of ordering voltage and KVA ratings not listed under this specification. In comparing proposals or bids, consideration will not be confined to lowest ownership cost only. The successful bidder will be one whose product is judged to best serve the interests of the City of Vernon when first cost, lowest ownership cost, product, safety, quality, and delivery are considered. The City of Vernon reserves the right to reject any or all proposals or bids or any part thereof, and to waive any minor technicalities from the specifications. A contract will be awarded to the bidder submitting the lowest responsible bid meeting the requirements of this specification. 2.0 APPLICABLE STANDARDS A. The transformers shall conform to the applicable sections of the following standards to the extent referenced in this Specification, and as amended to the date of this Specification which, by reference, are included as part of this Specification. A. C57.12.00 IEEE Standard General .Requirements for Liquid - Immersed Distribution, Power, and Regulating Transformers. B. C57./12.10 Requirements for Transformers 230,000 Volts and Below, 833/958 through 8,333/10,417 kVA single phase, and 750/862 through 60,000/80,000/100,000 kVA three phase without Load Tap Changing; and 3750/4687 through 60,00/80,000/100,000 kVA with Load Tap Changing -Safety Requirements. C. C51.12.20 Overhead -Type Distribution Transformers, 500 kVA and Smaller. High Voltage, 34 500 Volts and Below; Low Voltage 7970/13800Y Volts and Below D. C57.12.90 IEEE Standard Test Code for Liquid -Immersed Distribution, Power, and Regulating Transformers and IEEE Guide for Short -Circuit Testing of Distribution and Power Transformers. E. C57.91 Guide for Loading Mineral -Oil -Immersed Overhead and Padmounted Transformers Rated 500 kVA and Less with 650C or 550C Average 3of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS Winding Rise. F. C57.106 IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment. o. ill tile event or concoct Detween the codes and standards and this Specification, Supplier shall notify City of Vernon Light and Power Department and secure a written clarification before proceeding with the work. 4of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 3.0 SERVICE CONDITIONS 3. 1. Environment A. The transformers shall perform in accordance with all provisions of the Specification while subject to the service conditions specified in ANSUIEEE C57.12.00. B. The transformer shall be suitable for 30 years of use on the City of Vernon's electric system when installed in accordance with the service conditions set forth in the latest edition of the ANSUIEEE C57.12.00, Section 4.0, in its entirety. 3. 2. Seismic and Impact Loading A. Before and during installation, the transformers shall withstand, without damage, rough handling such as bouncing on a truck when filled with insulating medium and impacting against or upon rigid structures at speeds up to five feet per second, and being lifted by two bosses or lifting second, and being lifted by two bosses or lifting bolts at any angle. Following these conditions, the transformers shall be capable to being energized without a pre- operational test. B. After installation and during the 30-year life of transformer, transformer will be subject to occasional earthquake motions (0.2g horizontal and 0.13g vertical) along with significant vibrations from traffic and from adjacent equipment. 3.3 Pre -installation Inspection The City of Vernon will, at its discretion, provide a pre -installation inspection of each transformer. 3.4 Operating Duty A. For its 30-year life, each transformer shall be suitable for operation under short circuit conditions as stated in the latest editions of ANSUIEEE C57.12.00 and C5712.90. Supplier shall supply verification that the design has passed the required short circuit criteria. 5of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 4.0 RATINGS 4.1 Sizes The transformers shall be sized as shown in Attachment A. 4.2 High Voltage Ratings Transformers shall be 60 Hz with BIL ratings and Insulation Class as shown in the table below. Transformer High Insulation Class (KV) Insulation BIL (KV) Voltage KV 7.2/12.47Y 15 95 16.34 18 125 4.3 Low Voltage Rating Transformers shall be 60 Hz with BIL ratings and Insulation Class as shown in the table below. Trancfnrmnr I —ar a/..Ia..,.,. 1•__..t_a:__ - - ----- Transformer High ---- �. w• v ...0 w.wa.vvqgN�G Insulation Class (KV) IJ LIIiJ Insulation BIL (KV) Voltage Volts 120/240 1.2 30 277 1.2 30 6of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 4.4. Impedances Transformer impedance shall not be less than those shown in the table below. All transformer testing to determine transformer impedance shall be based on the base kVA rating of the transformers 65 degree Celsuis temperature rise. The transformer impedances shall be shown on the transformer nameplate. Minimum Transformer Impedance VOLTAGE KVA %Z 240 10-75 2.0 240 100-167 2.5 240 250 3.0 277 15-100 2.0 277 167-333 2.5 277 500 3.0 5.0 CONSTRUCTION FEATURES 5.1 Coil and Core Construction A. The transformer core shall be of high efficiency rectangular wound core. . The core shall be made from one of two processes: single -turn laminations of high quality, grain oriented silicon core steel. Amorphous core (Le metallic glasses metal) transformers are not acceptable. B. The transformer coils shall be designed to maintain their nameplate KVA rating throughout the normal temperature range of operation which shall be 650C (80°C hot spot). All materials used shall be of the 65°C, 800C hot spot class. All materials shall be thoroughly tested for compatibility with all transformer components before being assembled. C. The primary coil shall be manufactured from heavy varnish or paper insulated aluminum or copper wire. The secondary coil shall be manufactured from full width aluminum strip whose edges are finished to prevent burrs and insulated with epoxy -diamond paper between layers of the conductor. D. All insulating paper used as layer insulation in transformer coil shall be bonded type, coated on both sides with a thermosetting adhesive and properly cured prior to impregnating with oil or the coils shall be wound with primary conductor containing a thermosetting adhesive that when properly cured will form an effective bond, both turn to turn and layer to layer. 7of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 5.2. Insulatina Fluid A. The transformer insulating fluid shall be standard electrical grade mineral insulating oil. The insulating oil shall be tested and degassed to assure a chemically inert oil. The transformers shall be furnished with oil which meets the requirements specified in ASTM Standard D 3487 for mineral insulating oil, except that the DBPC content (% by weight) shall not be less than 0.15. The insulating oil in the equipment shall conform with ANSI C57.106. B. All transformer oil shall be tested for polychlorinated biphenyl's (PCBs) per ASTM D4059 and certified as having no detectable levels of PCB. All oil furnished by supplier shall not contain any detectable traces of polychlorinated biphenyls. C. A sealed tank shall be provided on all transformers 5.3 Taps and Changers A. The transformers shall be furnished with full capacity high -voltage taps. The tap changer shall be externally operated and clearly labeled to reflect that the transformer must be de -energized before operating the tap changer as required in Section 3.3 of ANSI C57.12.26. Padlocking provisions shall be available for lever or hotstick operable handles. Tap changer operating mechanisms shall be permanently identified to show "De -energized Operation Only". Decals and stencils are not acceptable. The unit shall have one of the following tap configurations: Two - 2%% taps above and below rated voltage such as the following: VOLTAGE FULL CAPACITY TAPS 1 %340 17,200/16,770/15,910/15,480 7,200 7,56017,380/7,020/6,840 B. The tap changer position indicating nameplate shall have numerals or letters that are clearly legible and of permanent quality. Decals and stencils are not acceptable. 8of19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 5.4 Pressure Withstand and Pressure Relief A. An assembly shall be provided that is designed for pressure relief. The assembly shall remain effectively sealed for overloads and external secondary short circuits of the duration and magnitude allowed by industry standards, but shall relieve pressure at a minimum of 8 PSIG. Design should meet the requirement of the latest edition of the ANSI C57.12.20 paragraph 6.27 for relief of excessive pressure. B. The valve shall be of the indicating type with weatherproof cover, and equipped with a pull -ring for hook -stick operation. It shall have 1/4 inch NPT threads and be located on the tank wall above the oil level in either segment 2 or 4 as designed in ANSI C57.12.20, Table S2. The valve shall meet the following minimum operating characteristics: 1. Cracking Pressure: 10 PSIG 2. Re -seal: 5 PSIG 3. Flow Rates: 50 SCFM at 15 PSIG 100 SCFM at 50 PSIG C. The valve body and various parts of the device shall be corrosion resistant. Only the following pressure relief devices are acceptable: I. Circle Seal Model No. P60-383 2. Qualitrol Model No. 202-032-01 or 202-33-01 3. Beta Model Nos. 1712K-1, -5, -6, or Model No 1750K-5. D. The required electrical clearances between pressure relief valve and live parts shall be maintained. 5.5 Tank Pressure Withstand A. Tank withstand should meet the latest edition of NEMA TR1, Part 2. B. Tank bottom shall have a rolled edge and tank wall base which is three layers thick. 5.6 Tank Finish A. Tank covers shall have a slope of 15 degrees for moisture run-off and 100 kVA and below, shall have an insulated coating on the cover capable of withstanding 15kV at a 2000 volt/sec rate of rise, or equal, tested per ASTM D149 using 1/4" diameter electrodes, or equal. The results of design test to confirm this capability shall be submitted for approval. 9 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS B. The tank coat will be a finish which can withstand a direct blow of 160 inch -pounds per ASTM D-2794-69 for units 100 kVA and below and meets or exceeds the following as set forth in ANSI C57.12.28: 1. Salt spray for 1000 hours 2. Humidity Test, 3. Abrasion resistance 4. Crosshatch adhesion 5. Oil resistance. C. The paint on all transformer tanks shall be grayish in color and conform to Munsell 5BG 7.0/04 with the following tolerances: 1. Hue: +/-12 (3G and 713) 2. Value: +/-0.2 3. Chroms: +/-0.2 5.7 Tank and Covers A. Transformers shall have bolted covers for all size transformers. One spare bolt per each transformer shall be provided and included in the bid. 5.7 Internal Lead Identification A. Internal secondary leads shall be identified with appropriate markings permanently embossed in the lead that correspond with lead markings on the nameplate. 5.8 External Features A. Transformers shall be provided with cover mounted high voltage porcelain bushings with eyebolt terminals, low voltage porcelain bushings with eyebolt terminals and ANSI single position support lugs (hanger brackets) with nameplate on lower bracket. For all transformers rated above 167 kVA, no support brackets are required. 5.9 Weight and Dimensions A. The maximum weight for transformers 100 kVA and below shall be 1,400 lbs. B. All 250, 333, and 500 kVA single phase transformers shall be 'light weight" transformers. The weights and dimensions of the 'lightweight' transformers shall not exceed the weights and dimensions specified below. 10 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS Rating (kVA) Weight (Ibs) Height Inches Width Inches Depth Inches 250 2,50072 41 38 333 2,800 72 41 38 500 3,300 72 50 42 5.11 Ground Provisions A. All transformers shall have a tank grounding provision. 5.12 High Voltage Bushings A. Transformer rated 15 kVA through 167 kVA shall be furnished with two cover -mounted bushings. High Voltage bushing terminals shall be in accordance with the latest edition of the ANSI Standard C57.12.20, paragraph 6.1.2.2. B. The cover -mounted bushings shall be of the 15kV insulation class for 7kV transformers and 17kV insulation class for 16kV transformers. The creepage distance of the bushings shall not be less than 15 inches. C. When the distance between live parts of cover -mounted bushings is less than 12 inches, the bushings shall be equipped with approved bird guards. Bird guards that are approved for use on overhead transformers are: MANUFACTURER MODEL NUMBER Coltec Industries 703803-53 Porcelain Products 65001 through 65019 RTE 0704119b01 Kuhlman Electric 6210209902 assembly 6210208804 assembly 11 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 5.13 Internal High -Voltage Connections A. Each internal high -voltage lead shall be equipped with either a ring - tongue or a hook -type connector. Each connector shall be terminated on a fixed threaded stud, a fixed threaded bolt, or a non -removable threaded bolt, each having two nuts for holding and locking purposes. 1. Ring -tongued type: The ring -tongue terminals shall have mechanical and electrical properties so as to contain the high - voltage leads, without breaking, even under short-circuit conditions. Bumdy type YAV are typical of the type desired. 2. Hook type: Hook terminals shall meet the same physical requirements as specified above for ring -tongue terminals. In addition to the above, both changing and locking nuts shall be held captive to prevent their complete removal. AMP, Inc. Style No. 3 "Hook" terminals are typical of the type desired. 5.14 Nameplates A. A stainless steel nameplate shall be attached with non -corrosive hardware to the inside of the low voltage compartment door. The nameplate shall not be installed on the rear of the low voltage compartment area. Diagrams and numbers shall be of the size and quality such that they can be read from outside the compartment. In addition to the nameplate requirements shown in ANSI/IEE C57.12.00- 1987, for nameplate A with total weight including oil shall be indicated. 5.15 MSDS A. The supplier shall be required to provide all applicable Material Safety Data Sheets with all transformer orders. 6.0 TESTS 6.1 General A. Transformer tests shall be performed as specified in ANSI Standard C57.12.00. These test reports shall be provided to the City prior to shipping. The City will not receive any transformers without the required test reports. B. Units shall comply with routine test requirements of ANSI and certified test reports shall be furnished. The vendor shall provide with returned bids all applicable documentation of compliance with ANSI design 12 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS tests. C. The following data shall be submitted with each transformer order: a. Guaranteed maximum no load (excitation) loss at rated voltage and 110% voltage in Watts. Y b. Guaranteed maximum load loss in Watts at rated voltage and 110% voltage. c. Guaranteed maximum total loss in Watts at rated voltage and 110% voltage. d. Exciting Current in percent at rated voltage and 110% rated voltage. e. Percent impedance on base voltage and at the maximum temperature rise. f. Efficiencies shall be provided at loading levels of 100%, 75%, 50%, and 25%. g. Regulation at rated load @ 80% and 100% Power Factor. h. Two sets of outline drawings showing dimensions, weight, gallons of oil, gauge of steel in tank walls, cover, bottom, and cooling radiators and description of accessories. After order is awarded, the vendor shall submit FINAL drawings. i. Verification that the transformer design has passed the required short circuit criteria per Section 3.4 of these specifications. 7.0 OPERATING PERFORMANCE 7.1 General The Apparatus shall perform in accordance with the conditions set forth in this Specification. 13 of 19 CITY OF VERNON LIGkT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 8.0 BID EVALUATION 8.1 Total Ownership Cost The purchase price of transformers shall be evaluated by lowest total ownership cost. The formula to evaluate Total Owning Cost (TOC): TOC = C + $4.53/W (PNL in Watts) + $1.1/W (PLL in Watts) Where TOC is the total ownership cost in dollars, C is the initial cost in dollars, PNL is the guaranteed maximum no-load loss in watts, and PLL is the guaranteed maximum load loss in watts For the determination of the award for the transformer order(s), City will consider all bids within 5% of the lowest Present Value Cost of Transformer to be economically equivalent. The City of Vernon realizes it is impossible to accurately predict economic conditions over the evaluation period of 30 year s. Reference Section 1, SCOPE, second paragraph of these specifications. 8.2 Delivery A delivery date of 16 weeks ARO or less is required. Failure to quote a delivery schedule within this period may disqualify the bid. 9.0 DOCUMENTATION 9.1 For Bid Evaluation Bidders shall furnish the following in their bid proposals: 1. Transformer unit price, F.O. B. Soto Yard. 2. Guaranteed maximum no-load loss at rated voltage in watts. 3. Guaranteed maximum load loss in watts at rated voltage and kVA. 4. Percent impedance on rated voltage tap. 5. Two sets of dimension and outline drawings. 14 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 9.2 For Delivery Supplier shall furnish MSDS and certified test reports and drawings, as listed in Section 11.1 in this Specification one month before transformers are shipped. - These documents shall be submitted to: City of Vernon Utilities Department 4305 Santa Fe Avenue Vernon Ca, 90058 Phone: (323) 583-8811 Attention: Jose Lugo Electrical Engineer 10. CONTRACT A. The vendor may be required to execute a purchase contract with City of Vernon, and may be required to furnish proof of insurance pursuant'to Attachment B, Insurance Schedule. If required, the vendor shall provide a letter from its insurance company that certifies the amounts of the insurance policy. The letter from the insurance company will be in substantially the same form as the SAMPLE INSURANCE FORM LETTER, which is also included in Attachment B. 11. SHIPMENT A. Supplier's quote shall be F.O.B. City of Vernon, Soto Yard located at 2800 Soto Avenue, Vernon Ca 90058. B. Transformers will be delivered on a flatbed truck for side unloading by forklift at ground level. C. Supplier shall notify City 48 hours prior to delivery. All delivery shall be Monday -Friday, 7:30 AM to 3:00 PM. Contact telephone is (323) 589- 9498 or (323) 585-5192. D. 15 days prior to shipment, supplier shall furnish certified test reports of the switch. E. 15 days prior to shipment, supplier shall furnish three (3) sets of Operations/Instruction Manuals. 15 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS 12. WARRANTY Supplier shall provide warranty for a minimum of twelve (12) months after delivery. 16 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS ATTA 0%1 IR 2P&. . m 1 1 Hl.nivir-N I A I ranstormer Ratings Used by the City of Vernon ITEM QUANTITY RATED VOLTS (PRIMARY VOLTS) RATED VOLTS (SECONDARY VOLTS RATING (KVA) MATERIAL CODE 1 0 7200/12470Y 120/240 15 001-0151 2 3 7200/12470Y 120/240 25 001-0251 3 5 7200/12470Y 1201240 37.5 001-0371 4 0 7200/12470Y 120/240 50 001-0501 5 6 7200/12470Y 1201240 75 001-0751 6 0 7200/12470Y 120/240 100 001-1001 7 0 7200/12470Y 120/240 167 001-1671 8 0 7200/12470Y 2771480Y 15 001-0152 9 8 7200112470Y 277/480Y 25 001-0252 10 0 7200/12470Y 2771480Y 37.5 001-0372 11 0 2200/1 4470Y 277/480Y 50 001-0502 12 0 7200/12470Y 277/480Y 75 001-0752 13 0 7200112470Y 277/480Y 100 001-1002 14 0 7200/12470Y 277/480Y 167 001-1672 15 0 7200112470Y 277/480Y 250 001-2502 16 0 7200/12470Y 277/480Y 333 001-3332 17 0 7200112470Y 277/480Y 500 001-5002 18 0 16340 120/240 15 002-0151 19 12 16340 120/240 25 002-0251 20 0 16340 120/240 37.5 002-0371 21 15 16340 1201240 50 002-0501 22 0 16340 120/240 75 002-0751 23 0 16340 120/240 100 002-1001 24 016340 120/240 167 002-1671 25 6 16340 2771480Y 10 002-0102 26 7 16340 277/480Y 15 002-0152 27 0 16340 277/480Y 25 002-0252 28 12 16340 277/480Y 37.5 002-0372 29 0 16340 277/480Y 50 002-0502 30 0 16340 2771480Y 75 002-0752 31 11 16340 2771480Y 100 002-1002 32 0 16340 277/480Y 167 002-1672 33 0 16340 277/480Y 250 002-2502 34 0 16340 277/480Y 333 002-3332 35 1 0 16340 277/480Y 500 002-5002 17 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS ATTACHMENT B INSURANCE SCHEDULE (Vendor) The Contractor shall provide proof of insurance, including a standard certificate of insurance, in at least the following amounts and coverage (combined single limit permitted): The general liability policy shall contain the following special endorsements which shall be noted on or attached to the standard certificate of insurance: An endorsement naming City, its officers, and employees as insureds under the policy. An endorsement providing City thirty (30) days notice of cancellation or material reduction of coverage. An endorsement providing coverage for all operations under City permit and specifying the activities covered. Such other endorsement as may be required by addendum hereto. In addition to the standard certificate of insurance, proof of general and umbrella liability coverage shall be furnished in the form checked below. Certification of the following proofs by the insurance agent or broker will not be accepted: For each policy, a notarized letter from the underwriter or carrier certifying that the coverage and statements in the standard certificate of insurance (attached thereto) are true and correct and that the signator is an officer authorized to so certify. A copy of each policy certified by an officer of the underwriter or carrier and notarized. 18 of 19 CITY OF VERNON LIGHT AND POWER OVERHEAD TRANSFORMER TECHNICAL REQUIREMENTS SAMPLE INSURANCE FORM LETTER (To be issued on insurance carrier letterhead. This letter must be notarized). Date: City of Vernon ("City") 4305 Santa Fe Avenue Vernon, CA 90058 Attn: Risk Management Department Re: Insurance for City of Vernon (description of permit or contract) Policy Number(s) Named Insured: City Clerk: I hereby certify that the certificate of insurance attached hereto and made a part hereof by reference truly and accurately represents the above -cited insurance policies and the insurance coverage of each for the named insured issued by (insurance can-ier) The City of Vernon, its officers, and employees are included in said policies as additional insureds and the City of Vernon will be provided with thirty (30) days written notice of cancellation or material reduction of coverage. I certify that I am an officer of the insurance carrier named herein and that I am authorized to sign this certificate on behalf of said insurance carrier. Signature Title 03/03 19 of 19